• Title/Summary/Keyword: electrical facilities

Search Result 1,222, Processing Time 0.032 seconds

Comparison and Analysis of Cometic and Foreign Standard for electrical facilities installation of entertainment spaces (유흥장 전기설비 설치에 대한 국내.외 규정 비교 분석)

  • Bae, Seok-Myung;Bang, Sun-Bae;Yi, Geon-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.321-325
    • /
    • 2004
  • Electrical facilities of entertainment spaces become more complicate and bigger due to growing industry and economy. Therefore using only Technical standards for Electrical facilities of internal standard, we have some difficulty for management and installation of electrical facilities of entertainment spaces. So this paper gives a information which is applied to install the electrical facilities of entertainment space by analysing and comparing of internal and external standard.

  • PDF

A development on the inspection technologies for secondary electrical facilities in nuclear power plant (원전 2차측 전력설비 검사기술 개발)

  • Park, Hyun-Shin;Kim, Kern-Joong;Kim, Moon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.110-112
    • /
    • 2005
  • Recently, the reactor trip in nuclear power plants has mostly occurred by the failure of secondary electrical facilities. Some kinds of technical standards or acceptable criteria are required to regulate those facilities. Therefore, in this paper the failures of secondary electrical facilities which cause reactor trip are analyzed, and the inspection technologies including guidelines for secondary electrical facilities are developed.

  • PDF

Reasonable Operation Method for Electrical Safety Management Agency System (전기안전관리대행 제도의 합리적 운영 방안)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kim, Sun-Gu;Hwang, Kwang-Su;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.14-19
    • /
    • 2012
  • This study proposes to suggest a direction hereafter which is the most suitable operating system of electrical safety management agency for electrical facilities to enhance electrical safety considering our domestic conditions. It was designed to prevent electrical disasters which are increasing due to environmental changes in the electrical industry, and the diversification and complication of the electrical facilities. And the strategy of this research is based on conditions of safety management agency for the electrical facilities, with the analysis on conditions of electrical disasters, and with a questionnaire investigation for owner of electrical facilities, safety management agency. Results of this research are expected to be used to prevent electric fires and shocks effectively by reinforcing the electrical safety management agency of electrical facilities having danger of large-scaled accidents. It is expected to enhance the nation's competing power against foreign countries by reducing the human and physical loss, resulted from the development of reasonable operating system for electrical safety management agency.

Quantitative Analysis on the Electrical Fire Preventive Effect of Safety Inspection for Electrical Facilities for General Use (일반용 전기설비 안전점검의 전기화재 예방효과에 대한 정량적 분석)

  • Kim, Taek-Hee;Yoo, Jae-Geun;Jeon, Jeong-Chay
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.45-49
    • /
    • 2015
  • This paper presents a quantitative analysis method to quantitatively indicate a electrical fire preventive effect of safety inspection for electrical facilities for general use. Logic model was developed based on whether enforcement of safety inspection for electrical facilities, and then the developed analysis model was converted to hydraulic model by using mathematical logic. The electrical fire preventive effect of safety inspection for electrical facilities was quantitatively calculated by applying electrical safety inspection results and fire statistics for five years to the developed hydraulic model. The results show that electrical fire preventive effects of 5,542 cases on annual average for five years.

An Influence of Electrical facilities Due to the Dust and Analysis about Domestic Regulations (분진에 의한 전기설비의 영향과 국내규정 분석)

  • Shong, Kil-Mok;Kim, Young-Seok;Jung, Jong-Wook;Jung, Jin-Su
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.387-390
    • /
    • 2008
  • This study investigated the influence of electric facilities damaged by dusts and domestic regulations. Its contents included the around circumstance of electric facilities, regulations concerned with the dust, the actual conditions at the scene, the characteristics of dusts and so on. At the set-up the electric facilities, the around circumstances are bad in summer that highly temperature and many moisture. Besides, elements that are judged the corrosive vapours of the large quantity are detected at the sampled dusts. As the results, if dusts covered with electric facilities, It will be a cause for the electric accidents. From the analyzed data of the actual conditions and the sampled dusts, electric facilities maintenance for the viewpoint of the safety can be possible.

  • PDF

Problems and Improvement Method of Safety Management of Electrical Facilities for General Use (일반용 전기설비 안전관리의 문제점과 개선방안)

  • Jeon, Jeong-Chay;Jeon, Hyun-Jae;Lee, Sang-lck;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.488-495
    • /
    • 2007
  • In spite of regular electrical safety inspection and improvement management of incongruent facilities, over 80 percent of electrical fires were generated in electrical facilities for general use, and the prevention of electrical safety accidents gets more difficult because of incomprehension on electrical safety inspection system, the increasement of non-inspection electrical facilities user, un-installation of residual current protective devices and leaving unsuitable equipments alone. This paper analyzed electrical safety inspection system of electrical facilities for general use and results of safety inspection and electrical fire statistics, and deducted the related problems. Also, improvement method of safety management of electrical facilities for general use was proposed in view of electrical safety inspection system, inspection implementation method, electrical fire statistics establishment, electrical safety consciousness and remote electrical safety inspection system.

  • PDF

Human Hazard by Outdoor Electrical Facilities in Submerged Area (옥외 전기시설물 침수시 누설전류에 의한 인체영향)

  • 하태현;이현구;배정효;김대경
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.602-607
    • /
    • 2003
  • We show three-dimensional distribution of voltages resulted from the leakage current originated from outdoor electrical facilities in a submerged area. In case these facilities are grounded by the neutral line multiple grounding method, the existence of ungrounded electrical facilities can cause a disastrous effect on near-by passengers. In order to investigate this situation, we installed a real-scale test field for the experiment type I (for the leakage current path between a enclosure grounded electrical facility and another enclosure grounded one), and that for the experiment type II (for the leakage current path between a enclosure grounded electrical facility and another ungrounded one). For both cases, we carried out three-dimensional monitoring of the voltage distribution while varying additional conditions such as the exposure of the underground cables and the finishing of cable connection part. The result shows that a disastrous effect on human safety can arise from the leakage current without a pertinent measure for the construction and maintenance of outdoor electrical facilities.

An investigation on the actual condition of electrical facilities in domestic fountains (분수대 전기설비의 국내 적용실태분석)

  • Kim, H.S.;Kim, C.M.;Hwang, K.S.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.44-46
    • /
    • 2005
  • An Electrical facilities of fountain is one of the vulnerable facilities because it is exposed to water. Especially, some children enter the fountain and play in the water in the hot season. For example, death from electrical shock in fountain was reported in domestic and foreign papers. In this paper, we analyzed the riskiness of electrical shock on the basis of a fact-finding survey and comparing the domestic and international standard of electrical facilities in fountains.

  • PDF

A Study on Program Development for Preventive Maintenance of Electrical Facilities (전기수용설비 예방보전을 위한 보수지원용 프로그램 개발)

  • Kim, Se-Dong;Choi, Do-Hyuk;Ryu, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.232-234
    • /
    • 1996
  • As a building is getting large-scale, composition and intelligence, it is required the stability of building electrical facilities. And it is very difficult of rapidly repair on a breakdown of building electrical facilities. Therefore high-reliability and efficiency of building safety is required. And thus, this study presents the repair-maintenance support program for preventive maintenance on a builing electrical facilities. This program makes offer some functions, facilities history input mode, checking and result mode. User can be made offer the cause and effect information of facilities-faults by this preventive maintenance program.

  • PDF

A Study on Improvement of Safety Management of Low Voltage Electrical Equiment (일반용 저압전기설비의 안전등급제 도입에 관한 연구)

  • Jae-Phil Han;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.598-602
    • /
    • 2023
  • With the purpose of instilling an awareness of the safety of users of electrical equipment and inducing voluntary facility improvement through the safety rating system for general low voltage electrical equipment, simulation and field application of the safety rating of general low voltage electrical equipment were conducted. For the introduction and application of the safety rating system for general low-voltage electrical equipment, data related to domestic safety was investigated and analyzed, cases of introduction in other fields were reviewed, and for design, the 4M risk assessment method of the Korea Occupational Safety and Health Agency and the cases of safety index development in Korea were analyzed and standardized. Safety rating system simulations were conducted for general low-voltage electrical equipment, and problem improvement measures were prepared by analyzing the results through on-site verification and simulation applied to the initial design. Design standards for the introduction of the safety rating system for general low-voltage electrical equipment were prepared, and 394 youth training facilities were applied to the field to see if the design standards were practically applicable to the field. With the application of the safety rating system for low-voltage electrical equipment for general use, youth training facilities that had been classified as 'appropriate' were able to induce an upgrade to a higher level through voluntary facility improvement according to the application of grades (A to E). As a result of inducing voluntary repair projects based on the results of the 1st and 2nd inspection of youth training facilities, it was confirmed that 86 facilities received grade A, 225 facilities received grade B, and only 311 facilities received grade A to B out of a total of 394 facilities, and there was no grade E.