Journal of rehabilitation welfare engineering & assistive technology
/
v.8
no.1
/
pp.9-17
/
2014
Electrical compound action potential (ECAP) can be recorded on cochlear implant. This study will investigate stimulation and recording to enhance the efficacy of ECAP. 34 articles was used. We analyzed pulse and stimulating condition, artifact suppression, recording condition. The cathod-leading biphasic pulse was used with as short as possible pulse width and inter phase gap for the efficacy of neural firing, stable threshold and preventing neural degeneration. Around C-level was stimulated to apical, middle and basal turn of cochlea. Artifact was eliminated by forward-masking, template-subtraction technique. For clearer waveform, we need to change distance between stimulating and recording electrode, the gain of amplification, number of average.
Purpose: In recent years, there has been increasing interest in using blood flow-restricted exercise (BFRE) or KAATSU training. The KAATSU training method, which partially restricts arterial inflow and fully restricts venous outflow in the working musculature during exercise at reduced exercise intensities, has been proven to result in substantial increases in both muscle hypertrophy and strength. The purpose of this study was to investigate the proper level of pressure for KAATSU training using compound muscle action potential (CMAP) analysis. Methods: Twenty-two healthy adults voluntarily participated in this study. CMAP was conducted by measuring the terminal latency and amplitude using a motor nerve conduction velocity test. For reference-line, supramaximal electrical stimulation was applied to the median nerves of the participants to obtain CMAP for the abductor pollicis brevis. For baseline, the intensity of the electrical stimulation was decreased to a level at which the CMAP amplitude was about a third of the CMAP amplitude obtained by the supramaximal electrical stimulation. The pressure levels for the KAATSU were set as a systolic blood pressure (strong pressure), the median values of systolic and diastolic blood pressure (intermediate pressure), and diastolic blood pressure (weak pressure). In the KAATSU condition, CMAP was performed under the same conditions as baseline after low-intensity thumb abduction exercises were performed at the subjects' own pace for one minute. Results: As the pressure increased, the CMAP amplitude was significantly increased, signifying that more muscle fibers were recruited. Conclusion: This study found that KAATSU training recruited more muscle fibers than low-intensity exercise without the restriction of blood flow.
Journal of the Institute of Electronics and Information Engineers
/
v.50
no.6
/
pp.287-293
/
2013
Cochlear implant (CI) is an auditory prosthesis that delivers electrical stimulation via inserted electrodes into a cochlea. To evaluate CI performance, it is important to understand how auditory nerves are responded to electrical stimulations. In clinic, electrically evoked compound action potential (ECAP) is measured. In this study, we developed 3D finite element (FE) cochlear model to simulate ECAP in response to electrical stimulation. The model prododuced ECAP similar to that measured in animal experiments and clinics. This 3D FE cochlear model could be used in electrical stimulus method study to improve CI by analyzing neural responses to electrical stimulations.
Journal of the Institute of Electronics Engineers of Korea SC
/
v.48
no.5
/
pp.81-92
/
2011
In this paper, a new method to estimate the number of MU (motor unit) related to the widths and distribution of end plate in NMJ (neuromuscular junction) of biceps brachii is proposed by varying muscle parameter statistically in EMG model. This work is done by designing MU-simulator and EPZ-simulator. The proposed method was compared with the results of previous researchers. The proposed MU-simulator generates SMUAP (single motor unit action potential) and CMAP (compound muscle action potential) signal similar to detected SMUAP and CMAP signal obtained from muscle. The EPZ-simulator estimate the numbers of MU by varying the widths and distribution of end plate in neuromuscular junction of muscle. The results shows that the numbers of MU was estimated about 450 ea. and muscle fibers was about 340 ea., end plate widths was about 6 mm, and end plate was randomly distributed. The proposed method may be comparable with the method of anatomical studies.
Kim, Sung-Hwan;Lee, Ho-Yong;Son, Dong-Il;Jung, Chul-Ki;Ko, Do-Young
The Transactions of The Korean Institute of Electrical Engineers
/
v.56
no.11
/
pp.2040-2050
/
2007
In this study, we present a novel method for estimating the information of MU(motor unit) which is the basic element of human muscle by using surface EMG. Some of the method developed in this field could only estimate the numbers of MU that is activated. However, in our study the MU-simulator based on the line source model was designed to estimate the MU information including the numbers of MU and muscle fiber, conduction velocity, MU diameter, fiber diameter, and end plate position. The SMUAP(single motor unit action potential) detector was designed and CMAP(compound muscle action potential) by electrical stimulus was recorded. With these data, the MU-simulator can estimate the MU information by varying muscle paramater settings through MSE(mean square error) method. Our results shows that the proposed method can be comparable with the method of anatomical studies. Moreover, our system can be utilized to build a tool for diagnosis and treatment assessment of neuromuscular patients.
The purpose of this study was to evaluate inter-rater reliability of the amplitude and first knee extension angles in deep tendon reflex test by using an electrical hammer. Twenty-five healthy adults participated in the study. Compound muscle action potential is elicited by tapping the knee tendon with an electrical hammer in deep tendon reflex tests. The amplitude and knee extension angle were simultaneously measured. The mean value of the amplitude and the knee extension angles through three time trials for each tester, are used for determining the inter-rater and Intra-class Correlation Coefficients (ICCs) reliabilities. According to the results, the ICCs of the amplitude is .280 and that of the knee extension angle is .789. Pearson correlation coefficients of the amplitude of the action potential and the knee extension angles are .685, showing significant statistically moderate correlation. Inter-rater reliability in the amplitude was not significant. More objective and quantitative deep tendon reflex tests should be done to obtain higher reliability in further studies.
Experiments were conducted in ischemic decerebrate cats to study the effects of electroacupuncture and electrical stimulation of peripheral nerve on pain reaction. Flexion reflex was used as an index of pain. The reflex was elicited by stimulating the sural nerve(20 V, 0.5 msec duration) and recorded as a compound action potential from the nerve innervated to the semitendinosus muscle. Electroacupuncture was performed, using a 23-gauge hyperdermic needle, on the tsusanli point in the lateral upper tibia of the ipsilateral hindlimb. The common peroneal nerve was selected as a peripheral nerve which may be associated with electroacupuncture action, as it runs through the tissue portion under the tsusanli point. Both for electroacupuncture and the stimulation of common peroneal nerve a stimulus of 20 V-intensity, 2 msec-duration and 2 Hz-frequency was applied for 60 min. The results are summerized as follows: 1) The electroacupuncture markedly depressed the flexion reflex; this effect was eliminated by systemic application of naloxone $(0.02{\sim}0.12\;mg/kg)$, a specific narcotic antagonist. 2) Similarly, the electrical stimulation of the common peroneal nerve significantly depressed the flexion reflex, the effect being reversed by naloxone. 3) When most of the afferent nerves excluding sural nerve in the ipsilateral hindlimb were cut, the effect of electroacupuncture on the flexion reflex was not observed. Whereas direct stimulation of the common peroneal nerve at the proximal end from the cut resulted in a significant reduction of the flexion reflex, again the effect was reversible by naloxone application. 4) Transection of the spinal cord at the thoracic 12 did not eliminate the effect of peripheral nerve stimulation on the flexion reflex and its reversal by naloxone, although the effect was significantly less than that in the animal with spinal cord intact. These results suggest that: 1) the analgesic effect of an electroacupuncture is directly mediated by the nervous system and involves morphine-like substances in CNS, 2) the site of analgesic action of electroacupuncture resides mainly in the brainstem and in part in the spinal cord.
Kim, Won-Ho;Park, Eun-Young;Chang, Ki-Yeon;Lee, Young-Jung
Physical Therapy Korea
/
v.9
no.3
/
pp.101-111
/
2002
The purpose of this study was to determine EMG biofeedback training effect on the muscle activities in 3 unilateral facial palsy patients along with multiple baseline design across subjects. The auditory feedback about facial muscles (orbicularis oris, orbicularis oculi, frontalis) was provided with each patient during facial exercise training. Electromyographic (EMG) activity during maximal voluntary contraction and maximal compound muscle action potential (CMAP) amplitude elected by supramaximal electrical stimulation on facial nerve of facial muscles were measured pre- and post- EMG biofeedback training to evaluate motor learning. EMG activity during maximal voluntary contraction was increased after EMG biofeedback training and CMAP amplitude elected by supramaximal electrical stimulation was not changed in all subjects. The results indicate that EMG biofeedback training is useful method to improve motor learning of facial excercise training in unilateral facial palsy patients.
Previously, we had reported that the electrical stimulation of peripheral nerve with stimlatory parameters of 20 V strength and 2 Hz frequency for 60 min resulted in reducing the pain reaction. The present study was performed to evaluate if the pain reaction was affected by the peripheral nerve stimulation with different stimulatory parameters in the decerebrated cat. The flexion reflex was used as an index of the pain reaction. The reflex was elicited by stimulating the sural nerve (stimulus strength of 20 $V\;\times\;0.5$msec) and recorded as a compound action potential from the motor nerve innervated to the posterior biceps femoris muscle. The common perneal nerve was selected as a peripheral nerve on which the electrical stimulation of various intensities and frequencies was applied. The results are summarized as follows : 1) The peripheral nerve stimulation with 100 mV strength, regardless of frequencies, did not affect the pain reaction induced by the sural nerve stimulation. 2) When the stimulus of 1V intensity and slow frequency (2 Hz) was applied to the peripheral nerve for 30 min or 60 min, the pain reaction was significantly reduced comparing to the control. However, this reduced pain reaction by the peripheral nerve stimulation was not reversed by the injection of naloxone (0.02 mg/kg) 3) High frequency stimulus (60 Hz) of 1V intensity for 30 or 60 min did not show any effects of affecting the pain reaction. These results suggest that the stimulus of relatively high intensity (at least 1V) and low frequency (2 Hz) is needed to elicite the analgesic effect by the peripheral nerve stimulation. By the 1V stimulus, $A\delta$ nerve fiber is activated. Therefore, an $A\delta$ or smaller nerve fibers must be activated for showing analgesia by the peripheral nerve stimulation. However, the mechanism of analgesia by the $A\delta$ nerve activation alone was not related to the endogeneous morphine system since the reduced pain reaction by the $A\delta$ fiber activation alone was not reversed by the treatment of naloxone.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.