• Title/Summary/Keyword: electrical charge and discharge

Search Result 574, Processing Time 0.031 seconds

Charge/Discharge characteristics of Li ion battery according to weight ratio of cathode to anode (리튬이온전지의 정.부극 중량비에 따른 전지의 충방전특성)

  • Eom, S.W.;Doh, C.H.;Hyung, Y.U.;Moon, S.I.;Yeom, D.H.;Yun, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1412-1413
    • /
    • 1996
  • Li ion battery have many advantages such as high energy density, high voltage and low self discharge, so it will replace conventional Ni/Cd battery. But, charge-discharge characterization of Li battery is controlled by weight ratio of electrodes (Cathode/Anode). So, we performed a study on relation between charge/discharge characterization and weight ratio (cathode/anode).

  • PDF

The effects of discharge gases in the voltage transfer curve of ac-PDP (ac-PDP의 전압전달특성에 미치는 방전가스의 영향)

  • Son, J.B.;Lee, S.H.;Kim, D.H.;Kim, Y.D.;Cho, J.S.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2233-2235
    • /
    • 1999
  • The ac plasma display panel(PDP) is a flat light-emitting gas discharge device. Discharge gases directly take effects to the discharge phenomena of ac PDP. Therefore it is necessary to understand the characteristics of the discharge gases. In this paper, we have studied the effects of discharge gases by voltage transfer curves which show the discharge characteristics of ac PDP and the change of the effective wall capacitance during a discharge which depends on lateral spreading of charge distribution and the strength of discharge. As gas pressure increases, memory margins increases. and the firing voltage of a mixed gas is lower than that of a single gas such as He gas. The minimum sustain voltage and the maximum sustain voltage or firing voltage increases with decrease in the frequency. The effective wall capacitance increases as the discharge strength that is, the gap voltage between discharge electrodes increases.

  • PDF

Properties of Polyacene Anode Derived from Phenolic Resin (페놀 수지로부터 유도된 Polyacene계 부극의 특성)

  • Oh, Won-Chun;Kim, Bum-Soo;Hwang, In-Soo;Lee, Young-Hoon;Lee, Byung-Eui
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.504-508
    • /
    • 1999
  • We have studied structural charecterization, electrical charge and discharge, and impedence properties for polyacene anode material derived from phenolic resin of novolak type. From the X-ray diffraction results, diffraction patterns for compounds of the three kinds of P-700, P-850, P-1000 were observed for semiirregular structural transition. A electrical charge and discharge data showed that the properties of p-850 was much better than any other samples. From the impedence properties for finding the effect of ions and electron transfer of battery, P-1000 and P-850 of high frequency of real number showed good electrical impedence properties.

  • PDF

A Control Design of Energy Storage System for Electric Railway Vehicle Using Supercapacitor (슈퍼커패시터를 이용한 전동차량용 에너지저장시스템의 제어기 설계)

  • Noh, Se-Jin;Lee, Jin-Mok;Son, Kyoung-Min;Choi, Eun-Jin;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.994-995
    • /
    • 2008
  • It is possible to suppress voltage drops, power loading fluctuations and regeneration power lapses for DC railway systems by applying an energy storage system. A electric double layer capacitor (EDLC) of the rapid charge/discharge type has been developed and used in wide ranges. It has a long life, high efficiency and maintenance free/low pollution features as a new energy storage element. In this paper, an efficient charge and discharge control method of a bidirectional DC-DC converter using the supercapacitor is proposed.

  • PDF

Measurement of Tree Growth Characteristics and Acoustics Emission Signals by Partial Discharge in XLPE (XLPE의 부분방전에 의한 트리진전 특성과 음향방출신호 측정)

  • Kim, Seung-Gyu;Lee, Sang-Woo;Lee, Kwang-Sik;Kim, Yeong-Hun;Kim, Geum-Yong;Kim, In-Sik;Kim, Lee-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1954-1956
    • /
    • 2000
  • In this paper, when void of XLPE was existed, electrical tree was growth in branch-type, and it was growth in bush-type when void of XLPE was not existed. Moreover, charge magnitude of partial discharge by deterioration time of XLPE sample was about proportion to output voltage of AE signals. When void was existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased with increasing deterioration time. However, when void were not existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased in fast deterioration time, but it were decreasing at after in middle deterioration time. Frequency spectrum response of AE signal was about 100-250[kHz].

  • PDF

A Basic Study on Electrification Phenomena of Synthetic Polymer Material (합성고분자재료의 대전현상에 관한 기초연구)

  • 이덕출;한상옥
    • 전기의세계
    • /
    • v.28 no.10
    • /
    • pp.48-54
    • /
    • 1979
  • The electrification phenomena of polymerized materials is governed by the competitive processes of the charge generation and the charge dissipation. In this paper, The charged particles were supplied on the naked upper surface of the polyethylene film from a point corona discharge with a screen electrode which controls the potential difference across the film. The charging current with the corona charging was found to be larger than that obtained with the electric charging on the MIM structure and the discharge current was found to flow in the same direction as that of the charging current. these results can suggest that the charge injection occurs from the interface between the polethylene surface and the accumulated charge layer, the injected charge are trapped and the space charge is established.

  • PDF

The dependence of the electrical characteristics of MgO on temperature in an AC PDP

  • Ha, Chang-Hoon;Jeong, Dong-Chul;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.714-716
    • /
    • 2005
  • We studied the dependence of the electrical characteristics of MgO protecting layer on temperature in an AC PDP cell. Careful measurements of the surface resistance of MgO were performed for the temperature range from room temperature to $100^{\circ}C$ with and without the VUV illumination. Experimental results show that the resistivity is affected by not only the temperature but also VUV irradiation. The measurement of wall charge distribution and the address discharge delay time as to the temperature show that the resistivity change of MgO may affect the wall voltage and consequently the discharge delay time.

  • PDF

A Study on the Design and Implementation of Charge and Discharge-Tester for Capacitors (콘덴서 양부판정용 충·방전 시험기 설계와 구현에 관한 연구)

  • Moon, Jong-Hyun;Kim, Geum-Soo;Park, Jae-Wook;Seo, Chul-Sik;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.71-78
    • /
    • 2010
  • The existing capacitor-testers could only judge the condition of capacitor is normal or abnormal, and could not inform the real characteristics of the tested capacitors. In this research, it has designed the real-time observation of the new capacitor in charge and discharge tester for showing capacitor conditions and classification through wide voltages by regular cycle-tests. And proposed the quality classification algorithm of capacitors for more simple and practical, and approve them by test.

A Study on the Algorithm of Battery SOH Estimation for Battery Management System(BMS) (배터리관리시스템(BMS)을 이용한 배터리 잔존수명(SOH) 추정 알고리즘에 관한 연구)

  • Seo, Cheol-Sik;Moon, Jong-Hyun;Park, Jae-Wook;Kim, Geum-Soo;Kim, Dong-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.317-320
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system controls the over and under currents of battery for protecting and it was applied algorithm for optimum conditions to estimate the State Of Charge(SOC) and State Of Health(SOH) in charge or discharge mode. It approved the performance and the algorithm for the estimation of SOH, through the experiments which using the charge and discharge tester and the field tests.

  • PDF

The Measurement and Analysis The Electromagnetic Wave by Discharge in Air for Insulation Diagnosis (절연진단을 위한 기중방전에서의 방사전자파 측정과 분석)

  • 이상훈;이현동;이춘하;윤영대;김기채;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.141-144
    • /
    • 1999
  • This paper offer fundamental ones about insulation diagnosis with electromagnetic wave, when discharges occurred. To simulate Partial-Discharge(PD), It is used needle-plane electrode in air. As the voltages applied, measure the electromagnetic wave with monopole antenna and analysis its fundamental characteristics, then, acquired data were operated. The results presented as the form of graph, and the magnitude of charge when occurred PD simultaneously. In conclusion, when the magnitude of charge over 100[pC], the electric field strength changed, and then the magnitude of charge and the electric field strength increased samely.

  • PDF