• 제목/요약/키워드: electrical breakdown

검색결과 1,944건 처리시간 0.025초

나노 실리카 충진함량 변화에 따른 EMNC의 특성 연구 (2) -기계적, 전기적 특성 중심으로- (Properties of EMNC According to Addition Contents Variation for Nanosilica (2) -For Mechanical, Electrical Properties)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제25권11호
    • /
    • pp.886-894
    • /
    • 2012
  • In order to develop electrical insulation materials, epoxy-nanosilica-microsilica mixture composites (ENMC) was synthesized, and mechanical properties such as their tensile and flexural strength, and AC insulation breakdown strength were investigated. Properties of mechanical strength and AC insulation breakdown strength are analyzed as scale and shape parameter with respect to weibull plot. Their tensile and flexural strength, AC insulation breakdown strength were compared original epoxy or EMC to ENMC. The 4 phr nano-silica addition and the 65 wt% micron-silica mixture composite (ENMC) was found to have the highest tensile and flexural strength. In the tensile strength was improved 29%, and flexural strength was improved 60.9% higher than those of the original epoxy. In the insulation breakdown strength, ENMC_4 phr was improved 17% and ENMC_5 phr was improved 15.8% higher than those of the EMC.

트리잉 파괴에 따른 전기 및 AE신호의 분석 (Analysis of Electrical and AE Signals by Treeing Breakdown)

  • 이상우;김성규;김인식;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2335-2337
    • /
    • 1999
  • In this paper, using AE (Acoustic Emission) sensor the electrical and emitted-sound signals are measured by treeing breakdown in the epoxy resin, and the corresponding frequency spectrum of the AE signals are analyzed. We also examined the relationship between partial discharge magnitude and pulse number of AE signals to diagnose the deterioration of the electrical insulation due to treeing breakdown. From these results, a frequency band of AE signals through treeing breakdown was set to about 230 [kHz], and it appeared that pulse number of AE signal was proportional to partial discharge magnitude.

  • PDF

고온초전도 케이블의 응용을 위한 PPLP의 절연파괴 특성연구 (Study on the Breakdown Performance of Synthetic Polypropylene Laminated Paper for Application of a HTS Cable)

  • 곽동순;김영석;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.65-68
    • /
    • 2003
  • In this paper, we researched breakdown characteristics of paper/liquid nitrogen composite insulation system for application of a high temperature superconducting cable. And, we have studied the AC breakdown performance of paper/ice composite insulating system immersed in liquid nitrogen. The electric strength in this paper/ice composite system is higher than that of paper/liquid nitrogen system. Furthermore this system shows a self-healing type breakdown behavior. Among the many kinds of liquid to be immersed and frozen to the ice, deionized water gives the highest electric breakdown strength. The paper/ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

절연 파괴 데이터를 이용한 에폭시 복합체의 절연 신뢰도 평가 (Evaluation of Insulating Reliability in Epoxy Composites using Dielectric Breakdown Data)

  • 박건호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.114-118
    • /
    • 2005
  • In this study, the DC dielectric breakdown of epoxy composites used for molding material was experimented and then its data were simulated by Weibull distribution equation. From the analysis of Weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5[kV/mm].

  • PDF

모의 GIS 내에서 파티클의 재질에 따른 절연파괴 특성 (The Breakdown Characteristics due to Particles in GIS Chamber)

  • 이재걸;곽희로;이강수;김경화;조국희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1997년도 추계학술발표회논문집
    • /
    • pp.67-69
    • /
    • 1997
  • Abstract - In this paper, the behaviour and effect of various particles made of conducting wires( Fe, Cu, Al ) in a SF6 insulated electrode system, are presented. It is shown that the ac breakdown voltage of compressed SF6 is influenced by different conducting particles. The breakdown voltage due to the particle is dependent of a class of particle. The breakdown voltage due to Cu particle was the highest and the breakdown voltage due to Al particle was the lowest.

  • PDF

Toughened 에폭시와 실리콘고무 계면의 교류 절연파괴 현상에 관한 연구 (Study on the AC Interfacial Breakdown Properties in the Interface between toughened Epoxy and Silicone Rubber)

  • 박우현;이기식
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1079-1084
    • /
    • 2002
  • Because complex insulation method is used in EHV(extra high voltage) insulation systems, macro Interfaces between two different bulk materials which affect the stability of insulation system exist inevitably. Interface between toughened epoxy and silicone rubber was selected as a interface in EHV insulation systems and tested AC interfacial breakdown properties with variation of many conditions to influence on electrical Properties, such as interfacial pressure, roughness and oil. Specimen was designed to reduce the effect of charge transport from electrode in the process of breakdown and to have the tangential electrical potential with the direction of the interface between epoxy and silicone rubber by using FEM(finite elements method). It could control the interfacial pressure, roughness and viscosity of oil. From the result of this study, it was shown that the interfacial breakdown voltage is improved by increasing interfacial Pressure and oil. In particular, the dielectric strength saturates at certain interracial Pressure level. The decreasing ratio of the interfacial breakdown voltage in non-oiled specimen was increased by the temperature rising, while oiled specimen was not affected by temperature.

XLPE/VLDPE 블렌드의 전기적 성질 (Electrical Properties of XLPE/VLDPE B1ends)

  • 고정우;서광석;김종은;강형식;김덕주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.215-218
    • /
    • 1998
  • XLPE/VLDPE (Crosslinked polyethylene/very low density polyethylene) blends were prepared by a twin screw extruder and their electrical properties such as water tree and breakdown characteristic were measured. it was found that both water tree and breakdown characteristics of XLPE were improved by the addition of VLDPE to polyethylene. It was also found that the extent of improvement of electrical properties by the addition of VLDPE to polyethylene depends on the type and concentration of VLDPE.

  • PDF

Electrical Breakdown Properties of Oil-paper Insulation under Pulsating Voltage Influenced by Temperature

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1735-1743
    • /
    • 2016
  • Insulation of valve-side windings in converter transformer withstands pulsating voltages, which will produce more serious insulation problems. In this paper, the electric breakdown experiments of oil-paper insulation specimens were executed at pulsating voltages and different temperatures. Experiment and analysis results showed that the breakdown voltage decreased with increasing temperature under pulsating voltage. The influence of temperature proves to be more significant once the temperature exceeds a limitation threshold. A fitting formula between breakdown voltage and the temperature was reported. Finally, in order to clearly understand the breakdown properties under pulsating voltage, the electric field distribution and space charge behavior under pulsating voltage at different temperature were discussed.

부분 방전 전하와 음향 방출 펄스의 동시 측정에 의한 트리잉 파괴 진단 (The Diagnosis of Treeing Breakdown Using Simultaneous Detection of Electrical Charge and Acoustic Emission Pulse of Partial Discharge)

  • 김성홍;박재준;김재환
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권3호
    • /
    • pp.247-254
    • /
    • 1997
  • Internal voids in insulators give rise to partial discharge, which causes a local breakdown and even entire insulation breakdown. Recently, the necessity of establishing the way to diagnose the aging of insulation materials and to predict of insulation breakdown become important. The purpose of our work are to investigate the treeing phenomena with an artificial needle shaped void by the charge of discharge and acoustic emission pulse in each phase angle area at the same time. We analyzed the .PHI.-QA-t pattern and .PHI.-AEA-t pattern using statistic operators such as pulse magnitude, pulse number, skewness, kurtosis. Therefore, the relation between the charge of discharge and acoustic emission pulse will be helpful to predict the breakdown just before the breakdown occur.

  • PDF

설계 및 공정 파라미터에 따른 3.3 kV급 Super Junction FS-IGBT에 관한 연구 (Study on 3.3 kV Super Junction Field Stop IGBT According to Design and Process Parameters)

  • 강이구
    • 한국전기전자재료학회논문지
    • /
    • 제30권4호
    • /
    • pp.210-213
    • /
    • 2017
  • In this paper, we analyzed the structural design and electrical characteristics of a 3.3 kV super junction FS IGBT as a next generation power device. The device parameters were extracted by design and process simulation. To obtain optimal breakdown voltage, we researched the breakdown characteristics. Initially, we confirmed that the breakdown voltage decreased as trench depth increased. We analyzed the breakdown voltage according to p pillar dose. As a result of the experiment, we confirmed that the breakdown voltage increased as p pillar dose increased. To obtain more than 3.3 kV, the p pillar dose was $5{\times}10^{13}cm^{-2}$, and the epi layer resistance was $140{\Omega}$. We extracted design and process parameters considering the on state voltage drop.