• Title/Summary/Keyword: electric tree

Search Result 143, Processing Time 0.034 seconds

Electrical Fire Hazards Analysis of Electric Iron and Heater Using Fault Tree Analysis

  • Hong, Sung-Ho
    • International Journal of Safety
    • /
    • v.7 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • The primary goal of this study is to analyze fire hazards of electric home appliances such as electric iron and electric heater using fault tree analysis(FTA). A fault tree(FT) is constructed and used to analyze fire hazards in electric home appliances. The fault tree is built from events that may occur in electric home appliances. The failure rate of basic events are derived from the value of experimental results and reference. And an algorithm analyzing fire in electric home appliances is suggested. We show how fault tree analysis, carried out by means of failure rate, is able to diagnose fire hazards of electric home appliances in a precise manner. We present numerical results such as fire probability of electric home appliances, importance measure, fire cause, etc. It can be helpful in preventing the fire hazards in electric home appliances.

The Study on Vigor and External Factors of Tree in Damaged Pine Stands by Thecodiplosis japonensis Uchida et Inouye (솔잎혹파리 피해임지내 수목의 외형적 인자와 관련한 수세변동과정 해석)

  • Lee, Chan-Yong;Kim, Joung-Kuk;Chae, Hee-Mun;Lee, Sang-Bae;Won, Dae-Sung
    • Journal of Forest and Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • This paper investigated external factors (height. crown width. diameter breath height, clear length) of tree and electric resistance ($k{\Omega}$) in damaged forest by Thecodiplosis japonensis Uchida et Inouye. The height. crown width and diameter breath height of tree external factors have high a coefficient of correlation. but clear length has not a coefficient of correlation. In relationship of electric resistance and external factor. big tree that height. crown width. diameter breath height has lower electric resistance value than that of small tree. (low electric resistance value is high tree vigor, high electric resistance value is low tree vigor)) Dead tree have smaller diameter breath height. crown width. higher clear length than survival tree in damaged forest by Thecodiplosis japonensis Uchida et Inouye. To investigation of relationship external factors according to electric resistance value. electric resistance value was divided three class (< $l4k{\Omega}$, possible of survival. $14{\sim}20k{\Omega}$, > $20k{\Omega}$, possible of dead). In lower class(< $l4k{\Omega}$), external factors have bigger which was height. crown width. diameter breath height and lower which was clear length than them of higher class ($14{\sim}20k{\Omega}$, > $20k{\Omega}$). Linear regression solutions of electric resistance and external factors were Y = -0.572 ${\times}$ Height - 1.163 ${\times}$ crown width - 0.242 ${\times}$ diameter breath height + 0.757 ${\times}$ clear length + 25.765. Regression solutions were significant in 5%.

  • PDF

The Study on Tree Vigor of Damaged Forest by Thecodiplosis japonensis Uchida et Inouye (솔잎혹파리 피해임지의 수세변동에 관한 연구)

  • Lee, Chan-Yong;Chae, Hee-Mun;Kim, Jong-Kuk
    • Journal of Forest and Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.34-41
    • /
    • 2000
  • This study investigated tree vigor of damaged forest by Thecodiplosis japonensis Uchida et Inouye. In damaged forest by pine gall midge, the investigation result of damaged rate section (severe, moderate, light) indicated that severe stand showed higher value of electric resistance ($k{\Omega}$) than that of light stand, the investigation result of tree density section(crowed, middle, little) indicated that crowed stand showed higher value of electric resistance than that of little stand (the value of electric resistance at which low reading show high vigor tree and high reading low vigor tree). The crown width and DBH (diameter of breast height) of external factors showed lower value of electric resistance than that of small size. The results of comparative between Crown area and value of electric resistance in each stand were $13.4m^2$ in severe stand, $10.9m^2$ in moderate stand and $7.9m^2$ in light stand. Therefore, the tree which have big crown showed low value of electric resistance (below $15k{\Omega}$)that has high possible of survial.

  • PDF

Electrical Treeing Phenomena at the Interface of Conductor and Insulator (도전체와 절연체 계면에서의 전기트링 현상)

  • 조영신;심미자;김상욱
    • Journal of the Korean institute of surface engineering
    • /
    • v.28 no.4
    • /
    • pp.236-242
    • /
    • 1995
  • This paper describes a study of electrical tree growth in DGEBA/MDA/SN system subjected to ac high electric field. The dielectric breakdown process, which consists of tree initiation, tree propagation and the complete puncture of the system was investigated. Dielectric breakdown always initiated from the needle tip where the electric field reinforcement is the highest. Higher temperature and voltage accelerated the tree growth and reduced the time to breakdown.

  • PDF

Effect of electrolyte on Bow-tie Water tree (Electrolyte 가 Bow-tie 형 수트리에 미치는 영향)

  • Kang, T.O.;Yang, W.Y.;Kim, K.S.;Chun, C.O.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1550-1552
    • /
    • 1994
  • In order to investigate the effect of electrolyte solutions on the activities of bow-tie water trees in XLPE insulated power cable, we have tried to observe the characteristics on water treeing ( bow-tie type ) using several electrolyte solutions such as $CH_3COOH$, $MgCl_2$,HCl and NaCl solution and tap water. Bow-tie tree density in $CH_3COOH$ and $MgCl_2$ solution was higher than in any other solution, and the growth of tree was stimulated in NaCl and $CH_3COOH$ solution, and diffusion of bow-tie trees into insulation in $MgCl_2$, HCl and NaCl solutions was faster than in $CH_3COOH$ solution and water. Also, although the increase of applied voltage caused bow-tie tree density to be high, it didn't affect the growth of tree maximum length noticeably.

  • PDF

Cost Reduction through Shortest Path Connection of Electric Power Line (전선의 최단거리 루트 선정을 통한 공사비용 절감 방안)

  • Lee, Sang-Joong;Yoon, Jun-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.34-38
    • /
    • 2011
  • The shorter the electric power line is, the less its cost becomes. In this paper, the Steiner tree is applied to find the shortest path of the electric power line to obtain resultant cost reduction. Up to 18.3[%] of length reduction can be expected compared to conventional method when the lines are connected through the Steiner points, which also can result in appreciable cost reduction.

Verifying the Possibility of Investigating Tree Ages Using Resistograph (레지스토그래피를 이용한 수령조사 가능성 검토)

  • Oh, Jung-ae;Seo, Jeong-Wook;Kim, Byung-Ro
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.90-100
    • /
    • 2019
  • This study aims to determine the ideal feed speed of a resistograph to evaluate the number of tree rings in several tree species. The needle speed was fixed at 1,500 r/min. Herein, various tree species, such as Pseudotsuga menziesii, Pinus koraiensis, Abies holophylla, and Zelkova serrata, were considered for experiments. Results showed that the most proper feed speed for Zelkova serrata, Larix kaempferi, Pseudotsuga menziesii, Abies holophylla, and Pinus koraiensis was 75, 100, 100, 150, and 175 cm/min, respectively. However, in all the cases, the electric resistance values of tree ring narrower than 1 mm were not suitable for determining tree-ring boundaries. Upon comparing the inter-annual time series of ring widths and electric resistance values of resistograph, a meaningful synchronization was verified. If resistograph would be improved to the extent that it can measure tree rings narrower than 1 mm, it can replace the conventional method used for counting the number of tree rings in the increment cores. Additionally, it can also be used to investigate the tree growth.

An efficient search of binary tree for huffman decoding based on numeric interpretation of codewords

  • Kim, Byeong-Il;Chang, Tae-Gyu;Jeong, Jong-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.133-136
    • /
    • 2002
  • This paper presents a new method of Huffman decoding which gives a significant improvement of processing efficiency based on the reconstruction of an efficient one-dimensional array data structure incorporating the numeric interpretation of the accrued codewords in the binary tree. In the Proposed search method, the branching address is directly obtained by the arithematic operation with the incoming digit value eliminating the compare instruction needed in the binary tree search. The proposed search method gives 30% of improved Processing efficiency and the memory space of the reconstructed Huffman table is reduced to one third compared to the ordinary ‘compare and jump’ based binary tree. The experimental result with the six MPEG-2 AAC test files also shows about 198% of performance improvement compared to those of the widely used conventional sequential search method.

  • PDF

Effects of Strong Wind and Ozone on Localized Tree Decline in the Tanzawa Mountains of Japan

  • Suto, Hitoshi;Hattori, Yasuo;Tanaka, Nobukazu;Kohno, Yoshihisa
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.81-89
    • /
    • 2008
  • The numerical simulation of wind and ozone ($O_3$) transport in mountainous regions was performed with a computational fluid dynamics technique. A dry deposition model for $O_3$ was designed to estimate $O_3$ deposition in complex terrain, and the qualitative validity of the predicted $O_3$ concentration field was confirmed by comparison with observed data collected with passive samplers. The simulation revealed that wind velocity increases around ridge lines and peaks of mountains. The areas with strong wind corresponded well with the sites of tree decline at high altitudes, suggesting that it is an important factor in the localization of tree/forest decline. On the other hand, there is no direct relationship between forest decline and $O_3$ concentration. The $O_3$ concentration, however, tends to increase as wind velocity becomes higher, thus the $O_3$ concentration itself may be a potential secondary factor in the localized decline phenomena. While the diffusion flux of $O_3$ is not related to localized tree decline, the pattern of advection flux is related to those of high wind velocity and localized tree decline. These results suggest that strong wind with large advection flux of $O_3$ may play a key role in the promotion of tree/forest decline at high mountain ridges and peaks.

Merits of all-electric subsea production control system

  • Oh, Jin-Seok;Kang, Se-Ra
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.162-168
    • /
    • 2014
  • Recently, researches on all-electric subsea system have been in progress. This paper describes a subsea tree using a lot of electrical signal and subsea control system. The way of subsea control is classified as all-electric systems or electro hydraulic systems. One of that has more merits in terms of cost, weight, power consumption, etc. because it uses electric signal instead of hydraulic signal. This paper describes the difference of each system's power consumption and simulation. As the result, if each system applies the same number of sensors, actuators, etc. The power consumption of all-electric system's load is less than at least 400kWh/day compared to the electro hydraulic system load.