• Title/Summary/Keyword: electric resistance values

Search Result 93, Processing Time 0.028 seconds

Effects of Melting Condition and Alloying Elements on Localized Corrosion Resistance of High Cr and N Bearing Stainless Steels

  • Yoo, Y.R.;Jang, S.G.;Cho, H.H.;Chang, H.Y.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.181-188
    • /
    • 2006
  • In this study, the characteristics of the experimentally produced high N-high Cr bearing stainless steels are discussed as a part of applications of materials for FGD (Fuel Gas Desulfurization) system of thermal power plants or for power plants using seawater as coolant. Corrosion resistance of developed alloys is especially investigated in detail. Corrosion characteristics of vacuum melted cast are shown to be superior to that of air melted one. From the viewpoint of CPT, It is estimated that the differences of corrosion resistance are $21.8^{\circ}C{\sim}24.6^{\circ}C$ at PRE 40 and $8^{\circ}C{\sim}12.4^{\circ}C$ at PRE 50, and the gaps becomes bigger as the PRE values are lower. In the evaluation of corrosion resistance in alloy A2501, Z3101, and A3301 according to Cr concentration, alloy A3301 shows a deviation from the general tendency in chloride solutions. It has relatively high PRE value as 48.6, but it has relatively poor pitting resistance. It is, however, difficult to observe a specific phase except ferrite in microstructure analysis and neither detects special phase such as sigma phase.

Detection Algorithm and Extract of Deviation Parameters for Battery Pack Based on Internal Resistance Aging (저항 열화 기반의 배터리 팩 편차 파라미터 추출 방안 및 검출 알고리즘)

  • Song, Jung-Yong;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.7
    • /
    • pp.515-520
    • /
    • 2018
  • A large number of lithium-ion batteries are arranged in series and parallel in battery packs, such as those in electric vehicles or energy storage systems. As battery packs age, their output power and energy density drop because of voltage deviation, constant and non-uniform exposure to abnormal environments, and increased contact resistance between batteries; this reduces application system efficiency. Despite the balancing circuit and logic of the battery management system, the output of the battery pack is concentrated in the most severely aged unit cell and the output is frequently limited by power derating. In this study, we implemented a cell imbalance detection algorithm and selected parameters to detect a sudden decrease in battery pack output. In addition, we propose a method to increase efficiency by applying the measured testing values considering the operating conditions and abnormal conditions of the battery pack.

Simulation of Cardiovascular System for an Optimal Sodium Profiling in Hemodialysis

  • Lim, K.M.;Min, B.G.;Shim, E.B.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.2
    • /
    • pp.16-26
    • /
    • 2004
  • The object of this study is to develop a mathematical model of the hemodialysis system including the mechanism of solute kinetics, water exchange and also cardiovascular dynamics. The cardiovascular system model used in this study simulates the short-term transient and steady-state hemodynamic responses such as hypotension and disequilibrium syndrome (which are main complications to hemodialysis patients) during hemodialysis. It consists of a 12 lumped-parameter representation of the cardiovascular circulation connected to set-point models of the arterial baroreflexes, a kinetic model (hemodialysis system model) with 3 compartmental body fluids and 2 compartmental solutes. We formulate mathematically this model in terms of an electric analog model. All resistors and most capacitors are assumed to be linear. The control mechanisms are mediated by the information detected from arterial pressoreceptors, and they work on systemic arterial resistance, heart rate, and systemic venous unstressed volume. The hemodialysis model includes the dynamics of urea, creatinine, sodium and potassium in the intracellular and extracellular pools as well as fluid balance equations for the intracellular, interstitial, and plasma volumes. Model parameters are largely based on literature values. We have presented the results on the simulations performed by changing some model parameters with respect to their basal values. In each case, the percentage changes of each compartmental pressure, heart rate (HR), total systemic resistance (TSR), ventricular compliance, zero pressure filling volume and solute concentration profiles are represented during hemodialysis.

  • PDF

Electric Characteristics and Modeling of Asymmetric n-MOSFETs for Improving Packing Density (집적도 향상을 위한 비대칭 n-MOSFET의 전기적 특성 및 모델링)

  • Gong, Dong-Uk;Lee, Jae-Seong;Nam, Gi-Hong;Lee, Yong-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.7
    • /
    • pp.464-472
    • /
    • 2001
  • Asymmetric n-MOSFET's for improving packing density have been fabricated with 0.35 ${\mu}{\textrm}{m}$ CMOS process. Electrical characteristics of asymmetric n-MOSFET show a lower saturation drain current and a higher linear resistance compared to those of symmetric devices. Substrate current of asymmetric MOSFET is lower than that of symmetric devices. Asymmetric n-MOSFET's have been modeled using a parasitic resistance associated with abnormally structured drain or source and a conventional n-MOSFET model. MEDICI simulation has been done for accuracy of this modeling. Simulated values of reverse as we11 as forward saturation drain current show good agreement with measured values for asymmetric device.

  • PDF

A Study on Measuring Electrical Capacitance to Access the Volumetric Water Content of Simulated Soil

  • Rial, W.S.;Han, Y.J.
    • Agricultural and Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.30-37
    • /
    • 2000
  • Wet porous media representing agronomic soil that contains variable water content with variable electrolyte concentration was measured to study the shape of the curves of the electric double layer capacitance versus frequency (from 10 KHz to 10 MHz. This was done in an attempt to find the lowest practical operating frequency for developing low cost dielectric constant soil moisture probes. Cellulose sponge was used as the porous media. A high frequency electronic bridge circuit was developed for measuring the equivalent network parallel resistance and capacitance of porous media. It appears that the effects of the electric double layer component of the total parallel network capacitance essentially disappear at operating frequencies greater than approximately 25 MHz at low electrolyte concentrations but are still important at 50 MHz at higher concentrations. At these frequencies, the double layer capacitance masks the diffusion region capacitance where true water content capacitance values reside. The general shape of the curve of volumetric water content versus porous media dielectric constant is presented, with an empirical equation representing data for this type of curve. It was concluded that the lowest frequency where dielectric constant values which represent true water content information will most likely be found is between 30 and 50 MHz at low electrolyte concentrations but may be above 50 MHz when the total electrolyte concentration is near the upper level required for most mesophyte plant nutrition.

  • PDF

Study of Freeze-thaw Resistance of Concrete using Fly-ash (플리이애쉬를 사용한 콘크리트의 동결융해 저항성에 관한 연구)

  • 최세규;임정호;김생빈;이석홍
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.123-128
    • /
    • 1998
  • Currently the study on the effective use of the fly ash is concentrated as construction materials, which is by product of electric power generating plants. Fly ash, therefore, can be used as concrete admixture for the purpose of not only increasing the concrete quality but also of utilizing materials. Within the country it is not easy to use fly ash for the construction purpose because the properties of fly ash are varied due to the use of different raw ores in the various power plants. And little previous construction experiments and the basic experiments about the formation of bubbles are performed. In this study the water-cement ratio is varied in 3 different values and compressive strength is measured and freeze-thaw experiments are preformed to establish the relationships between water-cement ratios and the durability. And also for each batch of different water-cement ratio fly ash is substituted 10%, 20% and 30% of cement and concrete mixture the admixture and the formation of bubbles and also freeze-thaw resistance.

  • PDF

Study on the Heat Generation Characteristics of the Carbon Heating Source with High Temperature (고온 카본발열체의 발열특성에 관한 연구)

  • Bae, K.Y.;Lee, K.S.;Shin, J.H.;Jeong, H.M.;Chung, H.S.;Chun, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.106-111
    • /
    • 2001
  • This paper is a study on the heat generation characteristics of the carbon heating source with high temperature. The main variables of this study are the input current and the amount of carbon heating source. As the results of the experiment in the waste rate of carbon heating source. The case of carbon heating source 300g was large than 500g. As the input current and the temperature are increased, the resistance values of carbon heating source were large. The Joule heat was represented the large value as the amount of heating source decrease with the input current. Finally, the heating source was represented the electrical steady state as the input current is increase.

  • PDF

CNTs Electric Field Enhancement of CIGS Solar Cells

  • Han, Seong-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.67-67
    • /
    • 2011
  • Compound semiconductor/CNTs composites have shown considerably improved efficiency improvement in photovoltaic devices, which is often attributed to two different factors. One is the formation of efficient electronic energy cascade structures. The other effect of CNTs on the performance of photovoltaic devices is the decrement of interfacial resistance. The interfacial resistances at n-type/ p-type materials and/or n-type materials/TCO electrode are reduced by an outstanding electrical property of CNTs. In addition to the effects of CNTs, we report the third reason for increment of efficiency in photovoltaic devices by CNT's well-known electrical field enhancement effects. The improved ${\beta}$ values in reverse-FE currents of CIGS electrode with SWNTs layers indicate the enhancement of electrical field in photovoltaic devices, which implies the acceleration of the electron transfer rate in the cell. Due to the formation of an efficient electronic energy cascade structure and the decrease of the interfacial resistance as well as the improvement of the electrical field in the photovoltaic devices, the power conversion efficiency of electrochemically deposited superstrate-type CIGS solar cells was increased 24.3% in the presence of SWNTs and showed 10.40% conversion efficiency.

  • PDF

Analysis of the International Safety Criteria of IEEE Std 80 and IEC 479-1 (배전용 접지전극 안전성 분석을 위한 국제기준 검토)

  • Kang, Moon-Ho;Park, Jae-Duck;Lee, Heung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.214-217
    • /
    • 2005
  • To improve the safety of facilities and human beings when the ground fault occurs, public power utility prescribes the reasonable ground resistances, measures and controls the ground resistance of all the ground electrodes biennially. Concerning the safety of human, there are two safety criteria widely accepted, i.e. the IEEE Std 80-2000 and the IEC 479-1:1994. The IEEE Std 80-2000 is based on a simplified electric shock model usually translated into permissible touch and step voltages. The IEC 479-1:1994 is less specific than IEEE Std 80-2000 for analysis purpose. The IEC 479-1:1994 provides values of permissible body current against electric shock duration. This paper provides a technical study of these two standards to analyze the safety of human beings of ground electrodes developed recently for distribution power system.

  • PDF

Initial Characteristics of Generator Stator Insulations (발전기 고정자 권선 절연재료의 초기특성)

  • Lee, Young-Jun;Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2110-2113
    • /
    • 1999
  • This paper describes the initial characteristics of turbine generators at the Taean thermal power plant #4 and Wolsong nuclear power plant #2. The turbine generators had been in service for two years. The insulation diagnostic tests included measurements of insulation resistance, polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharges (PD). The values of ac current and tan a were measured by Schering bridge. PD measurements were conducted using digital PD detector. The variation of $tan{\delta}$ and PD was confirmed in two generator stator insulations.

  • PDF