• Title/Summary/Keyword: electric pulse

Search Result 639, Processing Time 0.027 seconds

On the Analysis of Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant with State-space Model and Impulse Testing (상태공간 모델과 임펄스 시험에 의한 발전소 배관지지용 유압완충기의 동특성 해석)

  • Lee, Jae-Cheon;Hwang, Tae-Yeong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.89-99
    • /
    • 2001
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state-space model of 14th order to describe the dynamics of the snubber was established by Simulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absolvers against the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which temporarily lock the control valves up, however maintain same steady-state pressures of all internal chambers in the long run. Two case studies for the analysis of the snubber are addressed. Practical pulse testing method was also proposed to identify the frequency response of the snubber.

  • PDF

Effect of $\textrm{Ca}^{2+}$ Concentration on Electric Activation of In Vitro Matured Oocytes of Korean Native Cattle ($\textrm{Ca}^{2+}$ 씨오투 농도가 체외성숙 유래 한우 난자의 전기적 활성화에 미치는 영향)

  • 송길영;이은송;이병천;황우석
    • Journal of Embryo Transfer
    • /
    • v.11 no.3
    • /
    • pp.259-269
    • /
    • 1996
  • The present study was undertaken to examine the critical effect of $Ca^2$+ concentration on electrostimulation and post-electrostimulation media for electric activation of in vitro matured oocytes of Korean Native Cattle. Oocytes collected from slaughterhouse ovaries were matured in TCM 199 containing FSH, estradiol-17$\beta$ and FBS with granulosa cell monolayer for 24 hours and denuded with hyaluronidase. And then cumulus-free oocytes were submitted to a DC field of 1.0 kV/cm for 60 $\mu$sec in electroporation media(0.28 M mannito' and PBS) with different $Ca^2$+ concentations (0.00, 0.05, 0.10 and 0.15 mM). Stimulated oocytes were stained and examined for pronuclear formation after incuhation in SOF for 12 hours. The rates of pronuclear formation in hovine oocytes electrically stimulated in 0.28 M mannitol with 0.05, 0.10 and 0.15 mM $Ca^2$+(60.3, 82.2 and 75.0%) were significantly higher than without $Ca^2$+(6.3%) at 12 hours after an electric pulse(p<0.005). The activation rates of Korean Native Cattle oocytes stimulated in PBS supplemented with 0.05, 0.10 and 0.15 mM $Ca^2$+(71.0, 75.8 and 75.4%) were significantly higher than without $Ca^2$+(23.5%) after post-stimulation incubation(p<0.005). After incubation of oocytes in SOF with and without $Ca^2$+ following electric stimulation in 0.28 M mannitol with 0.10 mM $Ca^2$+, the rates of pronuclear formation of bovine oocytes in $Ca^2$+-free SOF(85.7%) was significantly higher than in SOF with 1.71 mM $Ca^2$+(62.5%, p<0.05). When oocytes were stimulated in two electrostimulation media supplemented with $Ca^2$+ and incubated in $Ca^2$+-free SOF, there were no significant differences in the rates of pronuclear formation hetween 0.28 M mannitol and PBS. These results indicate that a single electric pulse could induce activation of Korea Native Cattle oocytes in 0.28 M mannitol and PBS supplemented with $Ca^2$+. Furthermore, to improve the activation rates, it was hetter that stimulated oocytes were incubated in $Ca^2$+-free SOF after electric stimulation than in SOF with $Ca^2$+.

  • PDF

EMTP Simulation of Bipolar HVDC System (바이폴 HVDC 시스템의 EMTP 시뮬레이션)

  • Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1053-1055
    • /
    • 1998
  • Using EMTP model which describes bipolar HVDC system, switching level simulation results are presented in this paper. Voltage synchronization at point of common coupling, gate pulse generation and current control loops are represented in TACS module. The system consists of 100 km submarine cable rated 300 MW and 12 pulse rectifier and inverter stations which are connected to equivalent three-phase sources and loads through the 154 kV AC lines, respectively. In convertor stations, harmonic filters and capacitor banks are equipped to cancel out the harmonics generated by converters and to supply the required reactive power.

  • PDF

A Study on the Design of Branch Conductor in the Magnetic Pulse Generator (자기 펄스 발생기의 연결 도체 설계에 관한 연구)

  • SUH, JUBA
    • Journal of Industrial Technology
    • /
    • v.9
    • /
    • pp.101-107
    • /
    • 1989
  • The magnetic forming system must be able to store very important electric energy, several tens kilojoules, and flow this energy through the forming coil within some hundreds microseconds. So several hundreds kiloamperes of current can flow through the branch conductor. For the good performance of this type of machine, internal impedance must be minimized. By the computation of distribution of current inside the conductors using integral equation method, we can obtain the inductance and resistance of some dispositions of branch conductors and by comparison obtain some principles for the design of branch conductors in the high power magnetic pulse generator.

  • PDF

Stabilization Analysis of Piezo-electric Converter for PFM and PWM Control (압전 변압기의 제어 방식에 따른 모델링 및 안정화분석)

  • Yun, Seok-Teak;Park, Seong-Woo;Won, Young-Jin;Lee, Jin-Ho;Kim, Jin-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.401-401
    • /
    • 2009
  • Recently, demands for the development of compact, lightweight power supplies with higher power density and higher efficiency have been increased. Since Piezoelectric Transformer (PT) was emerged in device and material industry, it has been suggested as a viable alternative to the magnetic transformer in some applications. PT has some advantages such as low profile and mechanical energy transfer with little electromagnetic interface (EMI). Also, PT can provide high voltage stepping ratio with good isolation and requires no copper windings saving copper usage especially for large voltage conversion differences. Conventional control of PT converter has mainly two-way. One is the pulse frequency modulation (PFM) control method and the other is the pulse width modulation (PWM) control with frequency fixed method. It is known that the maximum PT efficiency can be obtained when it operates near the resonant frequency of the PT. And, also PT's resonant frequency moves according to the load condition. Therefore, selection of PT converter control method is very difficult. This paper analyzes general piezo-electric converter modeling and proposes a guide-line to selection of control method and stabilization control.

  • PDF

Developmental Rate of Rabbit Parthenogenetic Embryos Derived Using Different Activating Protocols

  • Chrenek, P.;Makarevich, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.5
    • /
    • pp.617-620
    • /
    • 2004
  • The present study compares development of rabbit embryos generated using different oocyte activation protocols and reconstructed with embryonic or cumulus cells as nuclear donor. In vivo matured oocytes were collected from New Zealand White rabbits at 16 h after ovulation treatment and were activated at18 h of post-ovulation treatment. The following schemes of oocytes activation were tested: 1) single electric pulse (EP, 3.2 kV/cm, 3${\times}$20 $\mu$s, 0.3 M mannitol)+5 min culture in the presence of 5 mM Ionomycin, 2) single electric pulse (EP, 3.2 kV/cm, (${\times}$20 $\mu$s, 0.3 M mannitol)+1 h culture in the presence of 2 mM 6-DMAP, and 3) three electric pulses 30 min apart. Cleavage rate, percentage of expanded and hatched blastocysts as well as total cell number of blastomeres of parthenogenetic embryos were significantly higher using either EP+6-DMAP or 3${\times}$EP schemes, comparing with EP+Ionomycin. Development rate up to hatched blastocyst stage of cloned rabbit embryos using the EP+6-DMAP for activation of nuclei were 19% for embryonic cell nuclei and 36% for cumulus cell nuclei. The best activation protocol optimalized in this study was the combined treatment "P+6-DMAP" which may be potentially used for nuclear transfer protocol.

Pulse Density Modulated ZVS High Frequency Inverter with Reverse Blocking Single Switch for Dielectric Barrier Discharge Lamp Dimming

  • Sugimura Hisayuki;Yasui Kenji;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.206-209
    • /
    • 2006
  • At present, the cold cathode fluorescent lamp (CCFL) using mercury lamp has been generally used far liquid crystal backlight source of personal computer and car navigation and so on. This kind of lamp is more excellent on luminance performance and cost. However, the requirements of liquid crystal backlight due to a light source without mercury have been strongly increased from a viewpoint of the actual influence on environmental preservation and environmental recycling. As fluorescent lamp without mercury, Dielectric Barrier Discharge based rare gas fluorescent lamp (DBD-FL) using xenon (Xe) gas has been studied so far. This DBD lamp has no influence on the human body and environmental recycle. Its operating life is long because electrode is out. In this paper, the simulation and experimental results of soft switching high frequency inverter with reverse blocking single switch as a high frequency power supply circuit for DBD-FL using Xe gas are comparatively evaluated and discussed from a practical point of view.

  • PDF