• Title/Summary/Keyword: electric meter

Search Result 206, Processing Time 0.03 seconds

DLMS SCADA System based on TETRA (TETRA 기반 DLMS 원방감시 시스템)

  • Song, Byung-Kwen;Lee, Suk-Hee
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.95-102
    • /
    • 2009
  • TETRA(TErrestrial Trunked RAdio) is wireless communication system generally adopted to public network and backbone network, as the technology of Trunked Radio System specified by ETSI(European Telecommunications Standards Institute) and currently adopted to the Electric Power IT Backbone Network in Korea. DLMS(Device Language Message Specification) is used in order to meter an electric measuring instrument value. In this paper, DLMS Server and Client simulator are used based on Window operating system. The multi-functional gateway, which transforms the communications based on RS-232C between DLMS Server Simulator and Client Simulator to the one based on TETRA PEI(Peripheral Equipment Interface), is developed such that DLMS SCADA(Supervisory Control And Data Acquisition) system is constructed based on TETRA.

  • PDF

Application of Full-Face Round by Sequential Blasting Machine in Tunnel Excavation (터널굴착에서 다단식 발파기에 의한 전단면 발파의 적용성 연구)

  • 조영동;이상은;임한욱
    • Explosives and Blasting
    • /
    • v.13 no.1
    • /
    • pp.20-31
    • /
    • 1995
  • Many methods and techniques to reduce ground vibrations are well known. Some of them are to adopt electric milisecond detonators with a sequential blasting machine or an initiating system with an adequate number of delay intervals. The types of electric detonators munufactured in Korea include instantaneous, decisecond and milisecond delays byt numbers of delay intervals are only limite from No.1 to No.20 respectively. It is not sufficient to control accurately milisecond time with these detonators in tunnel excavation. Sequential fire time refers to adding an external time delay to a detonators norminal firing time to obtain sequential initiation and it is determined by sequential timer setting. To reduce the vibration level, sequential blasting machine with decisecond detonatore was adopted. A total of 134 blasting was recorded at various sites. Blast-to-structure distances ranged from 20.3 to 42.0 meter, where charge weight varied from 0.25 to 0.75 kg per delay. The results can be summarized as follow : 1. The effects of sequential blasting machine on the vibration level are discussed. The vibration level by S.B.M. are decreased approximately 14.38~18.05 to compare to level of conventional blasting and cycle time per round can be saved. 2. The empirical equations of particle velocity were obtained in S,B.M. and conventional blastin. $V=K(D/W^{1/3})-n$. where the values for n and k are estimated to be 1.665 to 1.710 and 93.59 to 137 respectively. 3. The growth of cracks due to vibrations are found but the level fall to within allowable value.

  • PDF

Numerical and Experimental Analyses of a Hot-Wire Gas Flowmeter

  • Kim, Byoung-Chul;Joung, Ok-Jin;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1201-1206
    • /
    • 2003
  • A measurement device for gas flow rate using hot-wire module is developed for the utilization in low-accuracy industrial applications. The module has three wires of measuring and heating, and a bridge circuit is installed to detect electric current through the wire in the module. An amplification of the signal and conversion to digital output are conducted for the online measurement with a personal computer. In addition, temperature distribution in the module is numerically analyzed to examine the measured outcome from the module experiment. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. The experimental relation of measurement and flow agrees with the prediction from the numerical analysis. The outcome of the performance test indicates that the accuracy and reproducibility of the module is satisfactory for the purpose of industrial applications.

  • PDF

Development of Intelligent Trouble-Shooting System for Grinding Operation (인공지능형 연삭가공 트러블 인식.처리 시스템 개발)

  • Ha, M.K.;Kwak, J.S.;Park, J.W.;Yoon, M.C.;Koo, Y.
    • Journal of Power System Engineering
    • /
    • v.4 no.2
    • /
    • pp.25-30
    • /
    • 2000
  • The grinding process is very complex and relates many parameters to control the process. As this reason, a theoretical analysis and a quantitative estimation of the grinding process has not been well established. In this study, the in-process monitoring system was suggested by applying the neural network for monitoring and shooting the malfunction of cylindrical plunge grinding process. This system used the power signals from the electric power meter. This neural network was composed of processing elements [4-(5-5)-3] with 4 identified power parameters. Because sensitivity is blunted some minute vibration components, the simulation result of this system has appeared about 10% erroneous recognition in the uncertain pattern and the average success rate of the trouble recognition was about 90%. Consequently, the developed system, which applied to the power signals, can be recognize enough to monitor the grinding process as in-process.

  • PDF

Measurement Of The Engine Oil Relative Dielectric Constant With Respect To Capacitive Prove Dimension (정전용량 프로브 크기에 대한 엔진오일 상대 유전율 측정)

  • Kim, Ki-Hoon;Kim, Young-Ju
    • Tribology and Lubricants
    • /
    • v.27 no.4
    • /
    • pp.209-212
    • /
    • 2011
  • The capacitive application(prove) can be used to measure the complex permittivity of dielectric material of various thickness and cross section. This paper presents that we designed the analysis system of engine oil permittivity to know the relation between the engine oil deterioration and the prove dimension. Each of the dimension of capacitive prove is changed and then electric capacity is measured by LCR {Inductance(L), Capacitance (C), and Resistance (R)} meter. The engine oil permittivity has extracted in the prove measurement. As the additional research, this paper suggest the best of the prove dimension for the permittivity measurement.

Design and Test of Communication Between Data Concentrator Units for Efficient AMI(Advanced Metering Infrastructure) System (효율적 원격검침시스템 구축을 위한 집중장치간 연계통신 방법 설계 및 성능 테스트)

  • Im, Eun-Hye;Park, Byung-Seok;Kim, Young-Hyun;Choi, In-Ji;Myoung, No-Gil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2337-2343
    • /
    • 2010
  • AMR(Automatic Meter Reading)/AMI(Advanced Metering Infrastructure) is actively deployed all over the world. efficient, economical, stable and reliable system need to push forward the AMR/AMI business, so various researchs are in progress. In electric power system of domestic, a transformer is connected average twenty to thirty households and PLC is possible to communication within household connected same transformer. So if server and data concentrator unit(DCU) share circuit line through communication between transformers, communication network is able to efficient. Therefore we design new communication method between DCUs and test it and demonstrate the performance.

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

A Study on the Improvement of Measurement Accuracy of Laser Interferometer using the Kalman filter (칼만 필터를 이용한 레이저 간섭계의 측정 정밀도 향상에 관한 연구)

  • Lee, Jea-Ho;Park, Tea-Dong;Jung, Joon-Hong;Park, Ki-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1783-1784
    • /
    • 2006
  • A laser interferometer is the unique measurement device that can measure the range up to a few meters with sub-nano resolution and this characteristic makes it as the important sensing device for the emerging nano-mechatronics technologies. The laser interferometer, however, is very sensitive to the environments such as temperature, humidity, sound noises, vibrations and air turbulences and these factors result in a few hundred nano meter errors. There have been many efforts to reduce these environmental errors. The output of the laser interferometer is assumed to be the sum of a real displacement and a Markov process noise. The purpose of this paper is to develop Kalman filter algorithms to reduce the laser interferometer measurement errors by exploiting the information of displacements in position-servo systems.

  • PDF

Thermal and Electrical Properties of Conductive Polymer and PMMA, Eccogel Blend (도전성 고분자와 PMMA 및 Eccogel Blend의 열적 성질 및 전기적 특성에 관한 연구)

  • Park, Seong-Ja;Kim, Byung-Chul;Kim, Dong-Keun;Seul, Soo-Duk
    • Elastomers and Composites
    • /
    • v.24 no.3
    • /
    • pp.185-192
    • /
    • 1989
  • The thermal degradation of the homopolymer poly(methyl methacrylate)(PMMA)/tetra cyano quino dimethane(TCNQ) blend and Eccogel/TCNQ blend were carried out using the thermogravimetric method in the stream of nitrogen gas with 60ml/min at various heating rate from 1 to $20^{\circ}C/min$. Friedman and Ozawa mathermatical methods were used to obtain the value of activation energy. Produced electrical properties and activation energy by electric conductivity method that used LCR meter.

  • PDF

Modeling and prediction of rapid pollution of insulators in substations based on weather information

  • Nanayakkara, Nishantha;Nakamura, Masatoshi;Goto, Satoru;Taniguchi, Takashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.202-206
    • /
    • 1994
  • Mathematical model of the pollution rate of substation insulators is constructed, taking the model parameters as wind speed, wind direction, typhoon conditions and rainfall in an hourly basis. The main feature of model construction is to distinguish the effect of each parameter by separately analyzing the positive and negative pollution causing factors. Model parameters for the insulators of Karatsu substation, Saga, Japan were estimated and model validation was done using the actual data, in which the pollution deposits on the insulators were measured using pilot insulator and 'salt meter'. The proposed model of the pollution rate [mg/cm$^{2}$/hr] enables the identification of the effective parameters and prediction of the pollution rate so that it helps for the automatic decision making for insulator cleaning or the model can be used as a tool for the substation engineers to make precautionary measures.

  • PDF