• 제목/요약/키워드: electric field effects

검색결과 512건 처리시간 0.023초

전계효과에 의한 칼코게나이드 박막에서의 광유기 복굴절 특성 (The Properties of Photoinduced Birefringence in Chalcogenide Thin Films by the Electric Field Effects)

  • 장선주;박종화;여철호;정홍배
    • 한국전기전자재료학회논문지
    • /
    • 제14권1호
    • /
    • pp.58-63
    • /
    • 2001
  • We have investigated the photoinduced birefrinence by the electric field effects in chalcogenide thin films. The electric field effects have investigated the various applied bias voltages(forward and reverse) in chalcogenide thin films. A pumping (inducing) and a probing bean were using a linearly polarized He-Ne laser light (633nm) and semiconductor laser light (780nm), respectively. The result was shown that the birefringence had a higher value in DC +2V than the others, Also, we obtained the birefringence in the electric field effects by various voltages. In addition, we have discussed the anisotropy property of chalcogenide thin films by the electric field effects.

  • PDF

칼코게나이드 박막에서 전계효과에 의한 편광 홀로그래피 회절효율 특성 (The properties of diffraction efficiency in polarization holography using the chalcogenide thin films by the electric field effects.)

  • 장선주;여철호;박정일;정홍배
    • 한국전기전자재료학회논문지
    • /
    • 제13권9호
    • /
    • pp.791-795
    • /
    • 2000
  • Amorphous chalcogenide glasses have a wide variety of light-induced effects. In this study, we have investigated the diffraction efficiency of chalcogenide. As$_{40}$ Ge$_{10}$ Se$_{15}$ S$_{35}$ thin films by the various applied electric fields. The holographic grating in these thin films has been formed using a linearly polarized He-Ne laser light (633nm). The diffraction efficiency was investigated the two method of applied electric field in the perpendicular and parallel to the direction of inducing beam. We obtained that properties of diffraction efficiency in the two methods of applied electric field. The result is shown that the diffraction efficiency of parallel electric field is 285% increase, η=1.1$\times$10$^{-3}$ and the diffraction efficiency of perpendicular electric field is 80% decrease, η=9.83$\times$10$^{-5}$ . Also, we have investigated the anisotropy property on chalcogenide thin films by the electric field effects.

  • PDF

Experiment on the Anomalous Animal Behaviors by Electric Field Effects for Detecting Earthquake Precursors

  • Kyung, Jai-Bok;Yoon, Jang-Keun
    • 한국지구과학회지
    • /
    • 제23권1호
    • /
    • pp.112-118
    • /
    • 2002
  • The anomalous behaviour of animals prior to a large earthquake has been frequently reported from many places throughout the world since ancient times. This study is to experimentally testify what relations exist between the anomalous animal behavior and electric field effect, which is reported due to the piezo-electric effects in a basement rock before earthquake occurrences. We investigated the electric field effects on behaviors of two kinds of rats and birds. Rats show more sensitive anomalous behavior than birds. Even though the current applied to the experimental birds and rats is just a few ${\mu}$A, they show various abnormal behaviors. The anomalous animal behaviors under the small ground electric field may have some relations to the actual phenomena before great earthquake.

핵비등에서 기포의 동특성에 대한 전기장의 효과 (Effects of an Electric Field on the Dynamic Characteristics of Bubbles in Nucleate Boiling)

  • 권영철;장근선;권정태;김무환
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.963-971
    • /
    • 2000
  • In order to investigate the effects of an electric field on EHD(Electro-hydrodynamic) nucleate boiling hat transfer characteristics in a nonuniform electric field under saturated pool boiling, the basic study has been performed experimentally. In the present study, the working fluid is R-113 and the plate-wire electrode system is used to generate a steep electric field gradient. Boiling parameters are investigated by using a high speed camera. The electric field distribution around a wire is obtained to understand the effect of an electric field on bubble departure/movement. The experimental results show EHD effects are much more considerable when the applied voltage increases. Bubbles depart away from the heated wire in radial direction. It is confirmed that the mechanisms of EHD nucleate boiling are closely connected with the dynamic behavior of bubbles. The boiling parameters are significantly changed by the electric field strength. With increasing applied voltages, the bubble size decreases and the nucleation site density, bubble velocity and bubble frequency increase.

  • PDF

지진전조현상 파악을 위한 전기장 효과에 의한 동물 이상 행동 실험 (Experiment on the Anomalous Animal Behaviors by Electric Field Effects for detecting Earthquake Precursors)

  • 경재복;윤장근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.57-64
    • /
    • 2001
  • There are some previous reports that some animals such as rats and birds move in a large group and act abnormally to avoid the large earthquake. This study is to experimentally testify what relations exist between the anomalous animal behavior and electric field effect, which is reported due to the piezoelectric effects in a basement rock before earthquake occurrences. When electric field is applied to the whole bottom of the cage, they show nervous behaviors such as grooming, washing their faces, standing on legs or running around in panic to avoid the electric field. When more strong electric field is applied, they jump with shrieking and mount on the electric line. The rat shows more sensitive anomalous behavior than the bird. Even though the current to the experimental birds and rats is just a few $\mu$A, they react in various ways. The anomalous animal behaviors under the small ground electric field may have some relations to the actual phenomena before great earthquake. This kind of study is quite worthy for the understanding of earthquake precursors.

  • PDF

LDD MOSFET 채널 전계의 특성해석 (Characterization of Channel Electric Field in LDD MOSFET)

  • 박민형;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.363-367
    • /
    • 1988
  • A simple analytical model for the lateral channel electric field in gate - offset structured Lightly Doped Drain MOSFET has been developed. The model's results agree well with two dimensional device simulations. Due to its simplicity, our model gives a better understanding of the mechanisms involved in reducing the electric field in the LDD MOSFET. The model shows clearly the dependencies of the lateral channel electric field as function of drain and gate bias conditions and process, design parameters. Advantages of analytical model over costly 2-D device simulations is to identify the effects of various parameters, such as oxide thickness, junction depth, gate / drain bias, the length and doping concentration of the lightly doped region, on the peak electric field that causes hot - electron phenomena, individually. We are able to find the optimum doping concentration of LDD minimizing the peak electric field and hot - electron effects.

  • PDF

LDD MOSFET채널 전계의 특성 해석 (Characterization of Channel Electric Field in LDD MOSFET)

  • 한민구;박민형
    • 대한전기학회논문지
    • /
    • 제38권6호
    • /
    • pp.401-415
    • /
    • 1989
  • A simple but accurate analytical model for the lateral channel electric field in gate-offset structured Lightly Doped Drain MOSFET has been developed. Our model assumes Gaussian doping profile, rather than simple uniform doping, for the lightly doped region and our model can be applied to LDD structures where the junction depth of LDD is not identical to the heavily doped drain. The validity of our model has been proved by comparing our analytical results with two dimensional device simulations. Due to its simplicity, our model gives a better understanding of the mechanisms involved in reducing the electric field in the LDD MOSFET. The model shows clearly the dependencies of the lateral channel electric field on the drain and gate bias conditions and process, design parameters. Advantages of our analytical model over costly 2-D device simulations is to identify the effects of various parameters, such as oxide thickness, junction depth, gate/drain bias, the length and doping concentration of the lightly doped region, on the peak electric field that causes hot-electron pohenomena, individually. Our model can also find the optimum doping concentration of LDD which minimizes the peak electric field and hot-electron effects.

  • PDF

고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구 (A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment)

  • 이민규;정근식;감상규
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

Calculation on the Ion Flow Field under HVDC Transmission Lines Considering Wind Effects

  • Wu, Jing;Gao, Sheng;Liu, Yuxiao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2077-2082
    • /
    • 2015
  • Based on Deutsch assumption, a calculation method on the electric field over the ground surface under HVDC transmission lines in the wind is proposed. Analyzing the wind effects on the electric field and the space charge density the existing method based on Deutsch assumption is improved through adding the wind speed to the ion flow field equations. The programming details are illustrated. The calculation results at zero wind speed are compared with available data to validate the code program. Then the ionized fields which resulted from corona of ±800kV HVDC lines are analyzed. Both the electric field and the current density on the ground level are computed under different wind direction and speed. The computation results are in good agreement with measurements. The presented method and code program can be used to rapidly predict and evaluate the wind effects in HVDC transmission engineering.

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.