• 제목/요약/키워드: electric energy generation

검색결과 841건 처리시간 0.049초

유니몰프 압전소자를 이용한 발전 판넬의 출력특성에 관한 연구 (A Study of Output Characteristics for the Generation Panel using Unimorph Piezoelectric Element)

  • 김용혁
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.250-259
    • /
    • 2010
  • The ability for energy harvesting via the piezoelectric effect was studied for a unimorph element such as piezo buzzer. A simple equivalent circuit was proposed to predict the energy generated based on the internal stress. Unimorphs with a metal-cavity were used as a driving device of the generation panel. Both the AC open voltage and DC output voltage as a function of pressure period and number of element were measured. For the unimorph generation circuit, DC output voltage varies with pressure period, reaching a maximum value at $470{\mu}F$. The maximum output voltage a according to load resistance was measured at $1M{\Omega}$. Data analysis of the DC output voltage and time constant indicated that number of piezoelectric element of optimum was 60~80. It was found that piezoelectric unimorph has the possibility to be used as the driving element of the electric generation.

빌딩 마이크로그리드가 포함된 새로운 빌딩에너지 시스템 구축방향에 관한 연구 (The Novel Configuration for Building Energy System Including Build ins Microgrid)

  • 홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2008
  • The recent development of efficient thermal prime movers for distributed generation id changing the focus of the production of electricity from large centralized power plants to local generation units scattered over the territory. The scientific communality is addressing the analysis and planning of the distributed energy resources(der) with wide spread approaches, taking into account technical, environmental, economical and social issues. The coupling of cogeneration system to absorption/electric chillers or heat pumps as well as the interactions with renewable sources, allow for setting up multi-generation systems for building cooling heating and power(BCHP) systems of different energy vectors such as electricity, heat(at different enthalpy levels), cooling power, hydrogen, various chemical substances and so forth. Adoption of the composite multi-generation systems may lead to significant benefits in term of higher efficiency, reduced $CO_2$ emissions and enhanced economy. This paper outlines the main aspects of the BCHP system framework, illistrating its characteristics and summarizing the relevant distributed multi-generation structures.

  • PDF

안전성 확보를 위한 전기안전관리기준의 재설정에 관한 연구 (A Study on the Reconfiguration in the Regulation of Electric Safety Management for the Guarantee of Safety)

  • 정재희
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.45-49
    • /
    • 2009
  • This study is to prepare a reasonable basis for the improvement of the electrical safety management regulation. The standards in domestic and foreign countries for the application of new and renewable energy facilities and other devices are analyzed. Other regulations excluding the electrical safety fields and wide surveys are also carried out. Consequently, it is asked that the classification between normal and self electrical facilities should be clear and deregulation for small businesses has to be followed. This study is showed that standards investigates of receiving equipment below 600V above 75kW, eletrical safety manager employment of manufacturing industry and Mid-night electric power. And, it is showed that consignment permission and Consignment inspection periodic relaxation about wind development equipment below 1,000kW, consignment of Technical Development equipment for new and renewable energy below 250kW.

전력수급계획 및 운용해석 종합시스템 개발 (Development of the Integrated System for Power System Operational Planning an)

  • 박시우;윤용범;남재현;안양근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1042-1045
    • /
    • 1998
  • The main purpose of HITES(Highly Integrate Total Energy System) is to build and develop an integrated energy system for power system operational planning and analysis which consists of load forecast, economic generation schedule, stability analysis and relational database system. The integrated energy system can be utilized to supply a stable electric power and operate KEPCO power system facilities economically. This system will be put into operation in 1999. This paper describes the main feature of the HITES, system main functions, numerical methods adopted this system, and network configuration.

  • PDF

전력예비율과 전기요금, 신재생, 경제성장, 동·하계 동시피크 간 인과관계 연구 : OECD 패널 분석 (A Study on the Causality between Electric Reserve Margin, Electricity Tariff, Renewable Energy, Economic Growth, and Concurrent Peak in Winter and Summer: OECD Panel Analysis)

  • 이중호;박경민;박중구
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1415-1422
    • /
    • 2018
  • In Korea, prior to 2011, the electric reserve margin followed the probabilistic reliability view and the planning reserve margin had been operated at about 15% based on the assumption that power outage was permitted within 0.5 days a year. However, after experiencing the shortage of the electric generation capacity in Sept. 15, 2011, the planning reserve margin was selected as 22% to improve the reliability of the electric supply. In this paper, using panel data of 28 OECD countries over the period 2000-2014 we attempted to empirically examine the linkage between reserve margin, electricity tariffs, renewable energy share, GDP per capita, and summer / winter peak-to-peak ratios. As a result, all four independent variables have been significant for the electric reserve margin, and in particular, we found that countries with similar peaks in winter and summer have operated 4.3% higher reserve margin than countries experiencing only summer peak.

전력수급 종합시스템 현장적용 (Implementation of Highly Integrated Total Energy System)

  • 박시우;윤용범;남재현;추진부;최봉수;이효상;김준환;류성호;한승구;백웅기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1525-1525
    • /
    • 1999
  • The main purpose of HITES(Highly Integrated Total Energy System) is to build and develop an integrated energy system for power system operational planning and analysis which consists of load forecast, economic generation schedule, stability analysis and relational database system. The HITES can be utilized to supply a stable electric power and operate KEPCO's power system facilities economically. This system was put into operation in 1999. This paper describes the main feature of the HITES, main functions, numerical methods adopted in this system and network configuration.

  • PDF

대형상업건물의 열병합발전 부하조사 (A Survey on the Co-Generation Load for Large Commercial Buildings)

  • 한승호;권순우;정상원;정재혁
    • 에너지공학
    • /
    • 제7권2호
    • /
    • pp.223-230
    • /
    • 1998
  • 서울특별시 소재 대형 상업건물중 50개 에너지 다소비업체를 선정하여 에너지 사용실태를 조사하였다. 조사대상 건물은 병원, 호텔, 백화점/사무실 등 3개 집단으로 분류하여 시설현황, 에너지사용량, 부하분포특성 등을 분석하였다. 여름철 냉방전력 사용량이 열부하 피크 발생에 직접적인 영향을 미치는 것으로 나타났으며 이를 열병합발전-흡수식 냉동기 방식으로 대체할 경우 전기부하 분포가 연간 비교적 일정하게 변환시킬 수 있어 열부하추종운전방식에 적합함을 알 수 있었다. 그러나, 단일건물의 경우 연간열부하분포가 경제적 규모에 미달하여 단독으로 열병합발전 설비를 도입하기에는 미흡한 점이 있어 다수건물을 대상으로 하는 공동 열병합발전 방식이 보다 유리한 것으로 판단된다. 이를 추진하기에는 전기사업법, 액화천연가스 요금체계 등과 같은 법제도의 정비가 선결되어야 할 것이다.

  • PDF