• Title/Summary/Keyword: electric apparatus

Search Result 321, Processing Time 0.032 seconds

Reliability test design for Electric and movement apparatus of recliner sofa for home use (가정용 리클라이너 소파의 전기 및 기구부에 대한 신뢰성시험 설계)

  • Jang, In-Hyeok;Hyung, Jae-pil;Lim, Hong-Woo;Choi, Youn-Ok
    • Journal of Advanced Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.259-265
    • /
    • 2018
  • In this paper, we propose a test method to evaluate the reliability of the recliner sofa in the early stage of production. In order to develop the test method, we analyzed the failure mechanism occurring in the field and designed the performance test, environmental test, accelerated life test methods based on the analysis of failure mechanism. The failure mechanism is reproduced by applying the designed test. The reliability of the recliner sofa can be verified at the production stage through the proposed test method.

Development of a New-type Apparatus Decomposing Volatile Organic Compounds using a Combination System of an Electrical Exothermic SiC Honeycomb and a Catalytic Filter

  • Nishikawa, Harumitsu;Takahara, Yasumitsu;Takagi, Osamu;Tsuneyoshi, Koji;Kato, Katsuyoshi;Ihara, Tadayoshi;Wakai, Kazunori
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • A new-type apparatus decomposing volatile organic compounds (VOCs) using a combination system of an electrical exothermic SiC honeycomb and a catalytic filter was developed. This linear combination system is very useful to the catalytic decomposition of VOCs, because the gas involving VOCs is well heated in the SiC honeycomb and then flows into the catalytic filter. In the proposed apparatus, the outlet gas temperatures of SiC honeycomb maintained at ca. $300^{\circ}C$ after 5 min from the starting of applying electric current, and sufficient for the catalytic degradation of VOC components, i.e. toluene, isopropanol, methyl ethyl ketone and ethyl acetate. The average decomposition rate of total VOCs exhausted from a printing factory was 85% using pt catalyst at SV=19,000 in this system.

A Study on the Protection of Electric Shock, in Low Voltage (저전압에서의 감전보호에 관한 연구)

  • 이재인
    • Journal of the Korean Society of Safety
    • /
    • v.4 no.1
    • /
    • pp.83-90
    • /
    • 1989
  • Recently, due to the increase of 220V distribution lines and equipments preventive measures to cope with several kinds of electric accidents is revealed as an urgent problem. This study investigates the following matters; the cause and present condition of e1ectric shock accident, the influence of electric shock on human body, the safety limit of electric shock, the method of distribution voltage, the insulation of electrical load apparatus, the teachnics of electric shock prevention and foreign materials concerned with this subject etc. This paper present the fundamental cause of electric shock and syntbetic preventive counter measure of electric shock, too.

  • PDF

Development of Response Time Measuring Apparatus for Fencing (펜싱 훈련용 반응시간 측정장치 개발)

  • Gil, Se-gi;Lee, Sang Cheol;Hwang, Jong-Hak;Kim, Tae-Wan;Jung, Jin-Uk;Lee, Hyo-Geun;Han, Yeong-Hwan
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.315-320
    • /
    • 2016
  • In this study, we developed a response time measuring apparatus for fencing which can use fencing athlete's own electric sword and connectors. The measuring apparatus designed to be connected to upper back of dummy body and it's position can be changed by spinning itself. And it operates like a closed circuit composed of dummy helmet, the apparatus, reel signal connection, connector and electric sword of athlete. This measuring apparatus can provide response time to athlete immediately which response time is measured from the time of indicating random signal of light and sound to the time of attacking dummy by athlete. we carried out pilot test for couch and athlete of national fencing team and could validate availability of this system.

Analysis of the Rotational Magnetic Field using the FEM and the 2-Dimensional Permeability Tensor (유한 요소법과 이차원 텐서를 이용한 회전자계의 특성 해석)

  • Lee, Chang-Hwan;Kim, Hong-Kyu;Jung, Hyun-Kyo;Hong, Sun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.169-171
    • /
    • 1996
  • Recently, the finite element analysis(FEM) using two dimensional magnetic permeability tensor was introduced to calculate the magnetic field considering the rotational hysteresis. We obtain the tensor matrix from the measured data using two-dimensional magnetic measuring apparatus. We calculate the induced magnetic flux density and the rotational hysteresis loss under the model with the same condition with the measuring apparatus. Therefore we show that FEM with tensor can be used to calculate the magnetic flux density and the rotational hysteresis loss in the arbitrary rotational magnetic field.

  • PDF

A Simulation Technique for the Characterization of the Low-bit-rate Household AC Power Line Communication Channel (저 비트율 전력선 모뎀에 대한 저압 댁내망의 채널 특성 시뮬레이션 기법에 관한 연구)

  • An, Nam-Ho;Jeong, Tae-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.5
    • /
    • pp.197-202
    • /
    • 2002
  • In this paper, the characteristics of the household AC power line network is analyzed for the low bit rate powerline communication (PLC) in the frequency range from 10㎑ to 450㎑ The PLC channel transfer characteristics including its characteristic impedance are derived based on the network topology which is constructed with the household power lines loaded with the various types of electric apparatus. Both the distributed circuit analysis and the lumped circuit model based analysis are applied for the characterization of the PLC channel and the results are compared by the computer simulations. The analysis illustrates very well the adverse effects caused by the loading of electric apparatus and as well those casued by the reflection of wavers in the household AC Power line communication network.

Flow Characteristics of Dispersive ER Fluid Clearance between ER-Valve (ER-Valve 간극내에서 분산계 ER유체의 유동특성)

  • 장성철;염만오;이종두;장성수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1123-1126
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-Valve are measured by varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. The pressure drop according to the strength of electric field by differential pressure gauge in the present ER-Valve was used. This test reviewed experiment for the special changes of ER fluids in the steady flow condition.

  • PDF

A study on present status and improvement of protection relay system in subway station for stable power supply (지하철 역사의 안정적 전원공급을 위한 보호시스템 검토)

  • Na, Jong-Woo;Jo, Won-Kang;Park, Dong-Seon;Yoo, Yeon-Seong;Moon, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

A research on the actual condition fire dangerousness for electric installation of stables (축사 전기설비 화재위험성 실태조사)

  • Lee, Young-Soo;Kim, Myeong-Soo;Kim, Man-Keon;Kim, Hyeog-Soo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.9 no.1
    • /
    • pp.65-77
    • /
    • 2006
  • There is not high level to fire number in stables, but if it were fire, there would be happened many property damage in a national or personal. We grasp safety awareness of a safety supervisor enforcing question survey of electric installation for national stables, and investigate use the actual condition of electric installment with a heating apparatus, a ventilating system, a distributing board, a wiring apparatus etc high fire dangerousness among electric installment using a stables I hope to make use of data to protect a electric fire submitted thesis.

  • PDF