• 제목/요약/키워드: elastic analysis

검색결과 4,695건 처리시간 0.034초

Dynamic Electromyography Analysis of Shoulder Muscles for One-handed Manual Material Handling

  • Mo, Seung-Min;Jung, Myung-Chul
    • 대한인간공학회지
    • /
    • 제34권4호
    • /
    • pp.313-326
    • /
    • 2015
  • Objective: The objective of this research is to quantitatively analyze muscle activities of arm and shoulder, according to direction in various types of one-handed manual material handling, based on surface electromyography. Background: Workers in industrial sites frequently carry out one-handed manual material handling using arm and shoulder muscles. Therefore, chronic load and accumulated fatigue occur to arm and shoulder muscles, which becomes a main cause of upper arm and shoulder musculoskeletal disorders. The shoulder muscles have widely range of motion, and complex interactions take place among various muscles including rotator cuff muscles. In this regard, research on interactions among should muscles, according to such various dynamic motions, is required. Method: Ten male subjects in their 20s participated in this research. This research considered upward, downward, leftward, rightward, forward and backward directions and fourteen muscles around arm and shoulder (biceps brachii and trapezius, etc.) as independent variables. The mean muscle activity was set as the dependent variable. This research extracted $4^{th}{\sim}7^{th}$ repetition signals according to ten times of repetitive muscle contraction, and analyzed the muscle activity concerned using the envelope detection technique. Results: The mean muscle activity of upward direction was analyzed highly statistically significant. The reason is that the effect of gravity works to arm and shoulder muscles. Also, it is conjectured that deformation of coracoacromial ligament was caused, and its contact pressure increased, due mainly to the shoulder flexion, and therefore load was analyzed high. Muscle activity was analyzed significantly low, according to concentric ballistic motion used in the concentric contraction phase by storing elastic energy in the eccentric contraction phase with a motion to bring the weight to the front of subject's body as to downward, leftward and backward directions. Because, elbow joint's flexion-extension motions mainly occurred, biceps brachii was analyzed high muscle activity as the prime mover. Conclusion: The information on the quantitative load of muscles can be applied to ergonomic work design for one-handed manual material handling to minimize muscle load. Application: This research has effectively identified muscle activity according to dynamic contraction by applying an envelope detection technique. The results can be used for ergonomic work design to minimize muscle load during the one-handed manual material handling, according to each direction. The research results are expected to be used for musculoskeletal disorder prevention and physiotherapy in the rehabilitation medical field, based on the muscle load of arm and shoulder in various directions.

가토 대퇴정맥 미세정맥문합술 후 정맥 문합부 재생에 관한 미세조직학적 연구 (ULTRASTRUCTURAL STUDY FOR VEIN REGENERATION AFTER MICROVASCULAR ANASTOMOSIS IN RABBIT FEMORAL VEIN)

  • 노홍섭;김철환;김경욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권4호
    • /
    • pp.340-349
    • /
    • 2007
  • Free flap transplantation with microvascular anastomosis has been successfully performed by development of surgical technique, materials and postoperative monitoring equipments of flap. But success rate of microvascular anastomosis is influenced by various factors, and failure rate is about 5-10%. The most influential factor for success rate is surgical technique and other factors that influence failure of microvascular anastomosis are ischemic time of free flap, thrombus formation of anastomosis region and vascular spasm. In this study, vascular patency and thrombus formation in experimental micro-venous anastomosis, and endothelial repair were observed with histologic analysis, scanning electron microscopy, transmission electron microscopic examination. The results were obtained as follows: 1. In vascular patency test in 30 minute and 7 days after micro-venous anastomosis with heparin irrigation, all of 12 anastomosis site were good vascular patency. 2. In thrombus formation in 2 weeks group(Experimental I), 2 site of 6 cases were observed thrombus, and in 4 weeks group(Experimental II), 1 site of 6 cases were observed thrombus. 3. In histologic examination, normal vein(Control Group) showed continued internal elastic lamina, well formed thick smooth muscle layer and connective tissue. The group of 2 weeks after microvenous anastomosis(Experimental I) showd locally recovered internal lamina, discontinued internal lamina, disorganized smooth muscle cells and granulation tissue around suture silk. In the group of 4 weeks after micro-venous anastomosis(Experimental II), anastomosis site showed almostly continued internal lamina, disorganized smooth muscle cells and cicartrized tissue around suture silk. 4. In scanning electron microscope examination in 2 weeks(Experimental I) after micro-venous anastomosis, mesh fibrin formation showed near to endothelial cells, and in 4 weeks after micro-venous anastomosis(EXperimental II), numerous blood cells and fibrin mesh formation was seen associated with irregular endothelial cell arrangement. 5. In transmission electron microscope examination in 2 weeks after micro-venous anastomosis(Experimental I), irregular arrangement of smooth muscle cells was seen adjacent to collagenized tissue around suture silk. In 4 weeks after micro-venous anastomosis(Experimental II), denuded venous wall composed of relatively well arranged smooth muscle cells was covered by endothelial cells, but fibroblast cells and foreign body giant cells near to suture silk was remained. From the results obtained in this study, results of good vascular patiency and anti-thrombotic effect of heparin were obtained as a local irrigation solution, and repair of venous endothelial cell was observed in 2 weeks after micro-venous anastomosis.

T300/924C 탄소섬유/에폭시 복합재 적층판의 이차원 압축 강도의 크기효과 및 좌굴방지장치의 영향 (Two Dimensional Size Effect on the Compressive Strength of T300/924C Carbon/Epoxy Composite Plates Considering Influence of an Anti-buckling Device)

  • 공창덕;방조혁;이정환
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.88-91
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section (length x width) was investigated on the compressive behavior of a T300/924 [45/-45/0/90]3s, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a 30$\times$30, 50$\times$50, 70$\times$70, and 90mm$\times$90mm gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

  • PDF

일리노이 록스타 해석환경을 활용한 충격파관 내 금속패널 변형의 유체·구조 연성 해석 (An FSI Simulation of the Metal Panel Deflection in a Shock Tube Using Illinois Rocstar Simulation Suite)

  • 신정훈;사정환;김한기;조금원
    • 대한기계학회논문집A
    • /
    • 제41권5호
    • /
    • pp.361-366
    • /
    • 2017
  • 컴퓨팅 아키텍처와 응용 소프트웨어 기술의 발달로 최근에는 근사가 아닌 실제 물리계 모사라는 컴퓨터 시뮬레이션의 궁극 목표가 현실 이슈로 대두되고 있다. 본 논문에서는 미국 정부 주도 슈퍼컴퓨팅 기반 다물리 시뮬레이션 사업의 결과물로 나온 일리노이 대학의 일리노이 록스타라는 유체-구조-연소 연성 해석툴을 활용하여 충격파관 내의 금속판의 미소 시간 운동을 전산모사하고 기존 실험, 해석들과 비교하는 연구를 수행하였다. 전산유동해석은 정렬격자를 기반으로 하였고 구조해석은 대변형 선형탄성을 가정하였다. 또한 강한 연계 시간적분법이 적용된 알고리즘의 고도화로 인해 충격파 내 금속패널에 관한 높은 수준의 실험-계산 상관성을 보였다. 본 연구의 제한적인 검증연구를 확장하여 해석환경 내 추가 모듈들의 검증작업들과 코드개선을 통해 오픈소스 기반 연구개발 도구로서 활용할 예정이다.

N2 Method를 이용한 RC 중간모멘트 연성골조의 반응수정계수 및 내진성능 평가 (Estimation of R-factor and Seismic Performance for RC IMRFs using N2 Method)

  • 윤정배;이철호;최정욱;송진규
    • 한국지진공학회논문집
    • /
    • 제6권6호
    • /
    • pp.33-39
    • /
    • 2002
  • 반응수정계수는 구조물의 비탄성 거동을 설계에 반영하고 설계지진력 산정시 설계강도를 탄성범위 이내로 저감시키기 위한 목적으로 사용하고 있다. 그러나 설계코드에서 채택하고 있는 반응수정계수는 과거의 지진피해로부터 관찰된 보편적 구조성능에 기인한 경험치이므로, 주기에 따른 동적성능과 구조 시스템의 구성에 따른 내진성능을 정확히 대변하지 못하고 있다. 본 연구에서는 중간모멘트 연성골조를 대상으로 N2 Method를 이용하여 반응수정계수와 내진성능을 평가하였으며, 그 결과를 미국의 IBC 2000 코드와 비교하여 이론적 타당성을 검증하였다. 해석결과 코드에 제시된 반응수정계수와 잘 부합되는 것으로 나타났으나, 동일한 구조시스템의 경우에도 주기에 따라 비교적 큰 차이를 보였다. 성능목표에 따른 사용성 기준을 설정하여 IDI를 평가한 결과, 설계지진에 대한 성능목표가 건물에 대한 내진성능을 대변하기는 어려우며 PBD(Performance Based Design)에 의거한 합리적인 접근이 필요한 것으로 판단된다.

점성을 고려한 공진주 실험의 이론적 모델링 (Theoretical Modeling of the Resonant Column Testing with the Viscosity of a Specimen Considered)

  • 조성호;황선근;권병성;강태호
    • 한국지반공학회논문집
    • /
    • 제19권4호
    • /
    • pp.145-153
    • /
    • 2003
  • 공진주 실험은 탄성파 이론을 이용하여 흙의 동적 물성, 즉 전단변형률의 크기에 따른 전단탄성계수와 재료감쇠비를 측정하는 실험이다. 공진주 실험에 의한 시료의 동적물성의 측정은 공진주 실험 시스템의 동적 거동에 대한 이해를 전제로 한다. 공진주 실험의 시료 및 실험장치의 구성은 고정단-자유단 경계조건을 가지고 있는 연속보로 단순화할 수 있어서, Richart, Hall and Woods는 공진주 실험 시스템에 대한 파동방정식을 유도하였으나, 시료를 단순히 탄성으로 가정하였고 시료의 점성을 고려하지는 않았다. 그리고, Hardin은 파동방정식의 유도에서 시료의 점탄성을 고려하였으나, 시료의 전단탄성계수를 결정하기 위하여 시료의 점탄성을 가정하여야 하는 문제점을 가지고 있었다. 본 연구에서는 기존의 연구자들이 시도했던 공진주 실험 시스템에 대한 파동방정식을 새로운 측면에서 유도하였으며, 새로이 유도된 파동방정식의 해법을 제안하였다. 한편, 일반적으로 시스템에 대한 동적 거동을 이해하는 방법으로, 시스템의 운동방정식을 이용하는 방법이 있으나, 공진주 실험 시스템에 대한 동적 거동의 해석방법으로 이와 같은 운동방정식을 이용하는 해석방법을 연구한 경우는 거의 없었다. 운동방정식에 의한 해법은 시스템의 동적 증폭계수와 동적 응답에 대한 위상각을 구할수 있기 때문에 파동방정식에 대한 해법보다 더 많은 정보를 활용할 수 있는 장점이 있다. 따라서, 본 연구에서는 공진주 실험 시스템에 대한 보다 기본적이고 많은 정보를 도출하기 위하여, 공진주 실험 시스템에 대한 운동방정식을 유도하였으며, 이를 이용하여 공진주 실험자료를 해석하는 새로운 해석기법의 제안을 위한 근간을 마련하였다. 그리고, 공진주 실험 시스템에 대한 유한요소 해석을 수행하여, 본 연구에서 제안한 공진주 실험시스템의 이론적 모델링의 타당성과 합리성을 검증하였다.

압착되어 회전하는 강체/변형 롤의 동적 특성에 관한 수치해석 연구 (A Numerical Study on Dynamic Characteristics of Counter-Rotating Rigid/Deformable Rolls in Press Contact)

  • 이문규;이상혁;허남건;서영진;김인철;이성진
    • 대한기계학회논문집A
    • /
    • 제35권8호
    • /
    • pp.869-876
    • /
    • 2011
  • 동적 특성에 영향을 받는 롤 코팅의 평형적인 두께 예측과 불안정성을 분석함은 중요하다. 본 연구에서는 강체/변형롤 사이에서 생성되는 마이크로 코팅액의 두께를 예측하기에 앞서 압착되어 회전하는 두 롤 사이에 발생하는 접촉 압력의 분포와 변형롤의 변형 형상을 예측하고자 한다. 또한 변형롤의 재료상수와 롤의 속도 및 마찰계수 그리고 압착 크기 등의 변수들에 대한 접촉압력분포를 수치적인 방법으로 측정하여 유효한 변수들의 영향을 분석하고자 한다. 수치해석 방법으로는 유한요소법을 사용하였고 두 롤을 모델링하여 변형롤에 고무물성치를 초탄성체 모델로 가정하여 일반적으로 사용되는 Mooney Rivlin 계수를 사용하였고 40~80rpm 사이의 속도로 회전할 때 접촉 형상 및 압력분포를 분석하였다. 접촉형상의 경우 압착정도에 따라 변하고 그외 변수들에는 영향을 받지 않고 접촉압력의 경우 변형롤의 물성치와 압착정도에 의해 주요한 영향을 받고 속도 및 마찰계수에는 영향을 받지 않음을 알 수 있다.

전위 소성과 크기 종속 파손을 고려한 SiCp/Al2124-T4 복합재의 계층적 유한요소 모델링 (Hierarchical Finite-Element Modeling of SiCp/Al2124-T4 Composites with Dislocation Plasticity and Size-Dependent Failure)

  • 서영성;김용배
    • 대한기계학회논문집A
    • /
    • 제36권2호
    • /
    • pp.187-194
    • /
    • 2012
  • 일반적으로 복합재의 강도에 대한 크기 효과는 입자강화 알루미늄 복합재 제조시, 입자와 기지재를 압밀한 후 냉각할 때 입자와 기지재 사이의 열팽창계수 차에 의하여 기지재에 펀칭되는 기하적 필수 전위와, 변형 중 입자와 기지재사이의 탄소성 강성도 차로 인해 발생하는 변형률 구배 소성으로 인한 기하적 필수 전위가 주로 영향을 미치는 것으로 알려져 있다. 본 논문에서는 이러한 두 종류의 기하적 필수 전위를 전위 소성 이론에 입각하여 강도로 환산한 후 계층적으로 입자 주위 유한요소 영역에 할당하여 동일한 체적비에서 입자의 크기에 따라 변화하는 복합재의 파손 거동을 효과적으로 예측하였다. 이 방법을 적용함으로써 구형입자의 경우 간단한 축대칭 유한요소 모델링과 실험데이터를 연계하여 입자강화 복합재의 입자 크기 의존 강도 및 파손 효과를 수월하게 예측할 수 있음을 보였다. 또한 서로 다른 입자의 체적비 및 크기에 대하여SiC강화 알루미늄 2124-T4 복합재의 강도와 파손 거동이 분명한 차이가 있음을 보인다.

Q-응력을 이용한 휜 광폭평판 균열부 구속상태 변화 평가 (Investigation into Crack-Tip Constraint of Curved Wide-Plate using Q-Stress)

  • 이휘승;허남수;김기석;심상훈;조우연
    • 대한기계학회논문집A
    • /
    • 제38권12호
    • /
    • pp.1441-1446
    • /
    • 2014
  • 본 논문에서는 휜 광폭평판의 두께와 폭, 균열길이 그리고 가공경화지수의 변화가 휜 광폭평판의 균열부 구속상태에 미치는 영향을 평가하였다. 이를 위해 5가지의 휜 광폭평판 두께, 3가지의 균열길이, 3가지의 휜 광폭평판 폭 그리고 3가지의 가공경화지수를 고려한 3차원 탄소성 유한요소해석을 수행하였다. Ramberg-Osgood 관계식을 만족하는 비선형 재료로 가정하였으며 균열부 구속상태를 정량화하기 위해서 Q-응력을 이용하였다. 3차원 유한요소해석 결과를 바탕으로 기하학적 형상 및 재료특성에 따른 휜 광폭평판의 Q-응력 변화를 평가하였다. 평가 결과 면외 구속조건에 의한 영향은 면내 구속조건과 밀접한 관계가 있었으며, 면외 구속조건이 면내 구속조건 보다 균열부 구속상태에 더 큰 영향을 미쳤다.

Experimental investigation of the mechanical behaviors of grouted crushed coal rocks under uniaxial compression

  • Jin, Yuhao;Han, Lijun;Meng, Qingbin;Ma, Dan;Wen, Shengyong;Wang, Shuai
    • Geomechanics and Engineering
    • /
    • 제16권3호
    • /
    • pp.273-284
    • /
    • 2018
  • A detailed understanding of the mechanical behaviors for crushed coal rocks after grouting is a key for construction in the broken zones of mining engineering. In this research, experiments of grouting into the crushed coal rock using independently developed test equipment for solving the problem of sampling of crushed coal rocks have been carried out. The application of uniaxial compression was used to approximately simulate the ground stress in real engineering. In combination with the analysis of crack evolution and failure modes for the grouted specimens, the influences of different crushed degrees of coal rock (CDCR) and solidified grout strength (SGS) on the mechanical behavior of grouted specimens under uniaxial compression were investigated. The research demonstrated that first, the UCS of grouted specimens decreased with the decrease in the CDCR at constant SGS (except for the SGS of 12.3 MPa). However, the UCS of grouted specimens for constant CDCR increased when the SGS increased; optimum solidification strengths for grouts between 19.3 and 23.0 MPa were obtained. The elastic moduli of the grouted specimens with different CDCR generally increased with increasing SGS, and the peak axial strain showed a slightly nonlinear decrease with increasing SGS. The supporting effect of the skeleton structure produced by the solidified grouts was increasingly obvious with increasing CDCR and SGS. The possible evolution of internal cracks for the grouted specimens was classified into three stages: (1) cracks initiating along the interfaces between the coal blocks and solidified grouts; (2) cracks initiating and propagating in coal blocks; and (3) cracks continually propagating successively in the interfaces, the coal blocks, and the solidified grouts near the coal blocks. Finally, after the propagation and coalescence of internal cracks through the entire specimens, there were two main failure modes for the failed grouted specimens. These modes included the inclined shear failure occurring in the more crushed coal rock and the splitting failure occurring in the less crushed coal rock. Both modes were different from the single failure mode along the fissure for the fractured coal rock after grouting solidification. However, compared to the brittle failure of intact coal rock, grouting into the different crushed degree coal rocks resulted in ductile deformation after the peak strength for the grouted specimens was attained.