• Title/Summary/Keyword: efficiency test

Search Result 5,992, Processing Time 0.039 seconds

An Experimental Study About a Net-Type External Prestress Strengthening Method for Slab Bridges (네트형 외부 긴장재에 의한 슬래브교 보강 실험)

  • Han, Man Yop;Kang, Tae Heon;Choi, Sok Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.136-149
    • /
    • 2011
  • Large portion of the domestic bridges are slab bridges reflecting the geographical characteristic of the country, where exists lots of inclines and small winding brooks. Many of the slab bridges are damaged and superannuated as they become obsolete. Deterioration is accelerated when the traffic density becomes large and heavy vehicles pass frequently. A strengthening method for deteriorated slab bridges was studied in this work. The examined net-type strengthening method uses both longitudinal and transverse prestressing for strengthening. In this way, the deflection at the center of the slab can be better controlled, and consequently, the slab is more efficiently strengthened. Three slab specimens were fabricated for the experimental test and subjected to three different loading conditions, and the load bearing capacities and deflections of slabs were examined. Flexural stiffness of slabs increased by 30.7~107.3%, and deflection of slabs decreased by 27.6~52.2% after net-type strengthening. The net-type prestressing is efficient to the strengthening for the center of a slab, and its efficiency is also valid under eccentric loadings. Since extra prestress forces can be added in the future, if necessary, the net-type strengthening system is advantagous for the maintenance and repair of slab bridges.

Production of Extrudates Formulated from Pacific Sand Lance Sauce By-Product and Dried Biji (까나리 액젓 부산물과 건조 비지를 첨가한 압출성형물의 제조)

  • Han, Gyu-Hong;Kim, Byung-Yong;Lee, Jae-Kwon
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.186-193
    • /
    • 2002
  • This study was conducted to enhance the protein quality of wheat flour extrudates with the addition of fish sauce by-products and dried biji. The experimental design was used to determine the optimum ratio of each ingredient. The compositional and functional properties of test extrudate were measured, and these values were applied to the mathematical models. A canonical form and trace plot showed that the influence of each ingredient on the mixture final product. Protein content of extrudate was increased by the addition of the dried biji, and bending failure stress of extrudate became hardened due to interaction effects between dried biji and pacific sand lance sauce by-product. Also, the addition of dried biji decreased ash and salt contents. An optimum formulation was obtained as 15.83 : 44.17 : 40% with numerical and 15.74 : 44.26 : 26.40% with graphical method (pacific sand lance sauce by-product : dried biji : wheat flour). Based on the growth performance, feed conversion efficiency was slightly lower than control group, but the protein content in feed extrudate increased to a large extent compared to that mixed with wet biji.

A Study on Efficiency of the Combination of GPS and GLONASS (위성항법 측위에서 GLONASS가 미치는 영향에 대한 연구)

  • 조규전;공종덕;최일훈
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.4
    • /
    • pp.359-366
    • /
    • 2002
  • To survey satellites using only GPS can sometimes cause an impossible situation due to the many different geographical conditions as city cannon and obstacles. Although the GLONASS satellite system does not have the ability to survey itself accurately since it currently lacks of the number of usable satellites, it is able to bridge the gap when combined with GPS. This research used the GPS receiver to perform four analyzing methods to bring out the independent surveying method of GPS and combined surveying method of GPS and GLONASS(4 methods - number of satellites able to receive, precision of raw data, standard deviation from known point and RTK surveying). The result of test surveying satellites showed that 11 hours were possible to measure a minimum of 4 satellites when using an independent surveying method and 4 hours in unified surveying method in a month. Also, the precision of raw data using GPS and GLONASS surveying is 0.08~l.8m better than the GPS surveying in standard deviation. The deviation of known points by GPS and GLONASS also showed better accuracy by 3~l1mm. The RTK showed the range of differences in deviation of survey by leaning towards the GPS independent survey in Northing coordinate and leaned towards the Easting coordinate when GPS and GLONASS were combined. Nonetheless, it can't be said that the unified method is better, because it has limits to its capability.

Reinforcement and Arching Effect of Geogrid-reinforced and Pile-supported Embankments (지오그리드와 말뚝으로 보강된 성토지반의 보강 및 아칭효과 연구)

  • Oh Young-In;Shin Eun-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.10
    • /
    • pp.5-16
    • /
    • 2005
  • Geosynthetic-reinforced and pile-supported embankments have been increasingly used and researched around the world. The inclusion of one or multiple geosynthetic reinforcements over the pile is intended to enhance the efficiency of load transfer from soft ground to piles, to reduce total and differential settlement and increase global or local stability. In this paper, the reinforcement effectiveness and arching effect of the geogrid-reinforced and pile-supported embankments have been studied in terms of field model tests and numerical analysis with varying the space between piles and reinforcement. 2-dimensional numerical analysis has been conducted using the FLAC (Fast Lagrangian Analysis of Continua) program. And load transfer mechanisms between soil-piles-geogrid were investigated. The mechanisms of load transfer can be considered as a combination of embankment soil arching, tension geogrid, and stress concentration due to the stiffness difference between pile and soft ground. Based on the field model test and numerical analysis results, it was found that the geosynthetic reinforcement slightly interferes with soil arching, and helps reduce differential settlement of the soft ground. Also. at the D/b=3 (D: spacing of pile cap, b: diameter of pile), the total settlement is reduced by about $40\%$ compared to that without reinforcement. For $D/b{\ge}6$, the effectiveness of geogrid reinforcement in reducing settlement is negligible.

Development of the Measurement Method of Extremely Low Level Activity with Imaging Plate (Imaging Plate를 이용한 극저준위 방사능 측정에 관한 연구)

  • Kwak, Ji-Yeon;Lee, K.B.;Lee, Jong-Man;Park, Tae-Soon;Oh, Pil-Jae;Lee, Min-Kie;Seo, Ji-Suk;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.231-236
    • /
    • 2004
  • An imaging plate(IP) detector, a two-dimensional digital radiation detector that can acquire image of radioactivity distribution in a sample, has been applied in many fields; for industrial radiography, medical diagnosis, X-ray diffraction test, etc. In this study, the possibility of IP detector to be used lot measuring radioactivity of sample is explored using its high sensitivity, higher spatial resolution, wider dynamic range and screen uniformity for several kinds radiations. First, the IP detector is applied to measure the surface uniformity for area source. Surface uniformity is measured rapidly and nondestructively by measuring the radioactivity distribution of common standard area source$(^{241}Am)$. Next, the IP is employed to study the possibility of measuring an extremely low-level activity of environmental sample. For this study the screen uniformity, shield effect of background radiation, linear dynamic range and fading effect of the IP detector is investigated. The potato, banana, radish and carrot samples are chosen to measure ultra low-level activity of $^{40}K$ isotope. The efficiency calibration of IP detector is carried out using the standard source.

The Review of Exposure Index in Digital Radiography and Image Quality (디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구)

  • Yang, Sook;Han, Jae Bok;Choi, Nam Gil;Lee, Seong Gil
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The aim of this study was to determine the correlation between exposure index (EI) and dose factors related to radiation dose optimization in digital radiography (DR) system. Two phantoms with built-in regional test object for quantitative assessment of images were used to produce image signals that acquired in chest radiography background. EI and entrane surface dose (ESD) increased proportionally with rise of radiation dose (kVp, mAs) in both DR and CR systems. Especially, DR detector was effective to form good contrast and hence, reached easily to improvement of image quality with minimal dose changes. It made operators possible to expect the accuracy of EI values deeply related to absorbed dose of the detector. The evaluation of images was obtained specially employed calculation of noise to signal ratio (NSR) and contrast to noise ratio (CNR). These measurements were performed for how exposure factors affect image quality. NSR was inversely proportional to kVp and mAs and low NSR represented high signal detection efficiency. Consequently, EI values was the measure of the amount of exposure received by the image receptor and it was proportional to exposure factors. Therefore the EI in a recommended range from manufacturer can offer optimal image quality. Also, continuous monitoring of EI values in the digital radiography can reduce the unnecessary patient dose and help the quality control of the system.

A Study on the Cell Structure for Capacitive Deionization System (축전식 탈염 시스템을 위한 셀 구조에 관한 연구)

  • Lee, Ju-Young;Seo, Seok-Jun;Park, Jung-Woo;Moon, Seung-Hyeon
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.791-794
    • /
    • 2010
  • This study presents channel design of a CDI stack to achieve high removal efficiency in a large scale by applying parallel flow structure with a concentrated stream. The flow pattern in the stack was simulated by COMSOL Multiphysics program. To prove the salt removal performance, a unit cell and 20 cell stacks were tested at a flow rate condition of 18 ml/min and 360 ml/min, respectively. The removal efficiencies of the unit cell and the 20 cell stacks were obtained as 70.8 % and 75.6 %, respectively, with 100 mg/L sodium chloride solution. During the operation of cell test, water pressures of unit cell and 20 cell pair stack maintained in the ranges of 1.1 psi and 1.3~1.5 psi, respectively. It was demonstrated that the parallel cell structure with two concentrated streams can be employed in a large scale CDI for salt removal.

Shipboard Active Phased Array Antenna System for Satellite Communications (위성 통신용 선박 탑재 능동 위상배열 안테나 시스템)

  • 전순익;채종석;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1089-1097
    • /
    • 2002
  • In this paper, the novel shipboard Active Phased Array Antenna(APAA) system for maritime mobile satellite communications is introduced. The antenna uses novel technologies like wide range hybrid tracking, single antenna elements with both of Rx and Tx, asymmetrical array structure, interference isolation between Rx and Tx, and error correction method from frequency scan effect. The antenna has single aperture for both of Rx and Tx with 32 $\times$ 4 two-dimensional array. The antenna has two beams. Its frequencies are 7.25 ~ 7.75 GHz for Rx and 7.9 ~ 8.4 GHz for Tx. The antenna gains are 35.4 dBi for Rx and 35.7 dBi for Tx, those are 54 % of efficiency. The electrically steering ranges are $\pm$35$^{\circ}$ of elevation direction and $\pm$4$^{\circ}$ of azimuth direction. The mechanical control ranges at hybrid tracking capability are continuous 360$^{\circ}$ of azimuth direction and $\pm$10$^{\circ}$ of elevation direction. The antenna has 2.2$^{\circ}$ of 3 dB beamwidth, -14 dB of sidelobe level, and 21 dB of cross-pol suppression. The antenna performance was measured by near field measurement set. Its system performance was tested on the ship motion simulator and with the satellite transponder simulator. The test result showed that its tracking error was within -3 dB from its peak gain under motion condition. The antenna system was tested by real modulated Direct Broadcasting Satellite(DBS) signals to check its communication processing function.

Implementation of Sonar Bearing Accuracy Measurement Equipment with Parallax Error and Time Delay Error Correction (관측위치오차와 시간지연오차를 보정하는 소나방위정확도 측정 장비 구현)

  • Kim, Sung-Duk;Kim, Do-Young;Park, Gyu-Tae;Shin, Kee-Cheol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2019
  • Sonar bearing accuracy is the correspondence between the target orientation predicted by sonar and actual target orientation, and is obtained from measurements. However, when measuring sonar bearing accuracy, many errors are included in the results because they are made at sea, where complex and diverse environmental factors are applied. In particular, parallax error caused by the difference between the position of the GPS receiver and the sonar sensor, and the time delay error generated between the speed of underwater sound waves and the speed of electromagnetic waves in the air have a great influence on the accuracy. Correcting these parallax errors and time delay errors without an automated tool is a laborious task. Therefore, in this study, we propose a sonar bearing accuracy measurement equipment with parallax error and time delay error correction. The tests were carried out through simulation data and real data. As a result of the test it was confirmed that the parallax error and time delay error were systematically corrected so that 51.7% for simulation data and more than 18.5% for real data. The proposed method is expected to improve the efficiency and accuracy of sonar system detection performance verification in the future.

Efficacy of rifampin and streptomycin in Sprague-Dawley ratsinfected with Brucella abortus (Brucella abortus 감염 흰쥐에서의 rifaampin과 streptomycin의 치료효과)

  • Baek, Byeong-Kirl;Choi, Chun-ki;Lim, Chae-woong;Lee, John-hwa;Kim, Byeong-Soo;Lee, Sung-il;Hur, Jin;Ibulaimu, Kakoma
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.3
    • /
    • pp.433-439
    • /
    • 2004
  • This study was carried out to investigate the efficacy of rifampin with or without streptomycin in male Sprague-Dawley (SD) rats experimentally inoculated with Brucella abortus. Thirty rats were intraperitoneally inoculated with $1.0{\times}10^9$colony-forming units of B. abortus. They were divided into 3 groups by treatment with antibiotic. 10 rats in Group A were orally administrated with rifampin, 10 rats in Group B with rifampin orally and with streptomycin intramuscularly over 12 weeks starting at 1 week post infection (PI). A placebo recipient in Group C was inoculated with sterile saline without antibiotics. All animals were monitored by tube agglutination test (TAT) and AMOS-PCR to evaluate the efficiency of the antibiotics to B. abortus infection. The antibody titers in Groups A, B and C were 1:400, 1:400 and 1:800 as measured by TAT at the first week PI, respectively. The antibody titer in Group A decreased to 1:100 by the 13th week PI. That in the control group was observed as high antibody titer until 13th weeks PI, but the antibody response in Group B was low(1:50) from the 5th week to the 13th week PI. AMOS-PCR there was evidence of relapse of B. abortus in group A in liver and spleen specimens at the 13th week PI. B. abortus DNA was detected in Group C in liver and spleen specimens from the 1st week to 13th week PI by AMOS-PCR. However AMOS-PCR could not detect any organism in Group B from the 3rd week PI until the end of the study. This study demonstrated that administration of a combination of rifampin and streptomycin was more efficacious than administration of rifampin alone. A significant reduction in antibody titer was observed when a combination of 15 mg/kg/day of rifampin per os and 15 mg/kg/day streptomycin intramuscularly was used in comparison with the antibody of control group.