• Title/Summary/Keyword: effective earthquake forces

Search Result 49, Processing Time 0.022 seconds

Resonance Phenomenon according to the relationship between Span Length of the Bridge and Effective Beating Interval of High-Speed Train (교량의 지간장과 고속전철하중 유효타격간격 사이의 관계에 따른 공진현상)

  • 김성일;곽종원;장승필
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.67-76
    • /
    • 1999
  • Resonance of the bridge can be occurred with the coincidence between a natural frequency of the bridge and a crossing frequency of moving loads which is determined from the speed and effective beating interval of the vehicle. In case of the railway bridge, the effective beating interval of the vehicle is fixed under the passage of specific trains. In the present study, resonance and cancellation of the bridge subjected to moving high-speed train are analyzed with the variations of span length. A steel-concrete composite railway bridge is idealized by the combinations of plate elements and space frame elements. High-speed train is idealized with moving constant forces and a 3-dimensional full modelling. From analyzing dynamic responses of D.M.F of vertical displacement, maximum vertical acceleration of the slab, and end rotation according to the variations of span length of the bridge, design criteria of span length of the bridge which satisfies dynamic safety is discussed.

  • PDF

Automated Finite Element Mesh Generation for Integrated Structural Systems (통합 구조 시스템의 유한요소망 형성의 자동화)

  • Yoon, Chongyul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.77-82
    • /
    • 2023
  • The structural analysis module is an essential part of any integrated structural system. Diverse integrated systems today require, from the analysis module, efficient real-time responses to real-time input such as earthquake signals, extreme weather-related forces, and man-made accidents. An integrated system may also be for the entire life span of a civil structure conceived during the initial conception, developed throughout various design stages, effectively used in construction, and utilized during usage and maintenance. All these integrated systems' essential part is the structural analysis module, which must be automated and computationally efficient so that responses may be almost immediate. The finite element method is often used for structural analysis, and for automation, many effective finite element meshes must be automatically generated for a given analysis. A computationally efficient finite element mesh generation scheme based on the r-h method of mesh refinement using strain deviations from the values at the Gauss points as error estimates from the previous mesh is described. Shape factors are used to sort out overly distorted elements. A standard cantilever beam analyzed by four-node plane stress elements is used as an example to show the effectiveness of the automated algorithm for a time-domain dynamic analysis. Although recent developments in computer hardware and software have made many new applications in integrated structural systems possible, structural analysis still needs to be executed efficiently in real-time. The algorithm applies to diverse integrated systems, including nonlinear analyses and general dynamic problems in earthquake engineering.

A Simplified Procedure for Performance-Based Design

  • Zareian, Farzin;Krawinkler, Helmut
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.13-23
    • /
    • 2007
  • This paper focuses on providing a practical approach for decision making in Performance-Based Design (PBD). Satisfactory performance is defined by several performance objectives that place limits on direct (monetary) loss and on a tolerable probability of collapse. No specific limits are placed on conventional engineering parameters such as forces or deformations, although it is assumed that sound capacity design principles are followed in the design process. The proposed design procedure incorporates different performance objectives up front, before the structural system is created, and assists engineers in making informed decisions on the choice of an effective structural system and its stiffness (period), base shear strength, and other important global structural parameters. The tools needed to implement this design process are (1) hazard curves for a specific ground motion intensity measure, (2) mean loss curves for structural and nonstructural subsystems, (3) structural response curves that relate, for different structural systems, a ground motion intensity measure to the engineering demand parameter (e.g., interstory drift or floor acceleration) on which the subsystem loss depends, and (4) collapse fragility curves. Since the proposed procedure facilitates decision making in the conceptual design process, it is referred to as a Design Decision Support System, DDSS. Implementation of the DDSS is illustrated in an example to demonstrate its practicality.

Pushover Analysis of Reinforced Concrete Shear Wall Subjected to High Axial Load Using Fiber Slices and Inelastic Shear Spring (섬유(Fiber)요소와 비선형 전단스프링을 적용한 고축력을 받는 철근콘크리트 전단벽의 비선형거동 분석)

  • Jun, Dae Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.239-246
    • /
    • 2015
  • Reinforced concrete shear walls are effective for resisting lateral loads imposed by wind or earthquakes. Observed damages of the shear wall in recent earthquakes in Chile(2010) and New Zealand(2011) exceeded expectations. Various analytical models have been proposed in order to incorporate such response features in predicting the inelastic response of RC shear walls. However, the model has not been implemented into widely available computer programs, and has not been sufficiently calibrated with and validated against extensive experimental data at both local and global response levels. In this study, reinforced concrete shear walls were modeled with fiber slices, where cross section and reinforcement details of shear walls can be arranged freely. Nonlinear analysis was performed by adding nonlinear shear spring elements that can represent shear deformation. This analysis result will be compared with the existing experiment results. To investigate the nonlinear behavior of reinforced concrete shear walls, reinforced concrete single shear walls with rectangular wall cross section were selected. The analysis results showed that the yield strength of the shear wall was approximately the same value as the experimental results. However, the yielding displacement of the shear wall was still higher in the experiment than the analysis. The analytical model used in this study is available for the analysis of shear wall subjected to high axial forces.

Fragility assessment of shear walls coupled with buckling restrained braces subjected to near-field earthquakes

  • Beiraghi, Hamid
    • Steel and Composite Structures
    • /
    • v.33 no.3
    • /
    • pp.389-402
    • /
    • 2019
  • Reinforced concrete walls and buckling restrained braces are effective structural elements that are used to resist seismic loads. In this paper, the behavior of the reinforced concrete walls coupled with buckling restrained braces is investigated. In such a system, there is not any conventional reinforced concrete coupling beam. The coupling action is provided only by buckling restrained braces that dissipate energy and also cause coupling forces in the wall piers. The studied structures are 10-, 20- and 30-story ones designed according to the ASCE, ACI-318 and AISC codes. Wall nonlinear model is then prepared using the fiber elements in PERFORM-3D software. The responses of the systems subjected to the forward directivity near-fault (NF) and ordinary far-fault (FF) ground motions at maximum considered earthquake (MCE) level are studied. The seismic responses of the structures corresponding to the inter-story drift demand, curvature ductility of wall piers, and coupling ratio of the walls are compared. On average, the results show that the inter-story drift ratio for the examined systems subjected to the far-fault events at MCE level is less than allowable value of 3%. Besides, incremental dynamic analysis is used to examine the considered systems. Results of studied systems show that, the taller the structures, the higher the probability of their collapse. Also, for a certain peak ground acceleration of 1 g, the probability of collapse under NF records is more than twice this probability under FF records.

Case Study of Seismic Evaluation of Low-Rise Masonry Buildings (저층 조적건물의 내진성능평가 사례 연구)

  • Eom, Tae Sung;Kim, Chan Ho;Lee, Seung Jae;Kim, Jin Woo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • In this study, the seismic performance of a two-story unreinforced masonry (URM) building was assessed following the linear and nonlinear static procedures specified in the seismic evaluation guideline of existing buildings. First, the provisions to assess failure modes and shear strengths of URM walls and wall piers were reviewed. Then, a two-story URM building was assessed by the linear static procedure using m-factors. The results showed that the walls and wall piers with aspect ratios he // (i.e., effective height-to-length ratio) > 1.5 were unsafe due to rocking or toe crushing, whereas the walls with he // ≤ 1.5 and governed by bed-joint sliding mainly were safe. Axial stresses and shear forces acted upon individual masonry walls, and wall piers differed depending on whether the openings were modeled. The masonry building was reevaluated according to the nonlinear static procedure for a more refined assessment. Based on the linear and nonlinear assessment results, considerations of seismic evaluation for low-rise masonry buildings were given with a focus on the effects of openings.

INFRASTRUCTURE RISK MANAGEMENT IN PREPAREDNESS OF EXTREME EVENTS

  • Eun Ho Oh;Abhijeet Deshmukh;Makarand Hastak
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.83-90
    • /
    • 2009
  • Natural disasters, such as the recent floods in the Midwest, Hurricane Ike in the Gulf coast region (U.S.), and the earthquake in Sichuan (China), cause severe damage to the infrastructure as well as the associated industries and communities that rely on the infrastructure. The estimated damages due to Hurricane Ike in 2008 were a staggering $27 billion, the third worst in U.S. history. In addition, the worst earthquake in three decades in Sichuan resulted in about 90,000 people dead or missing and $20 billion of the estimated loss. A common observation in the analyses of these natural disaster events is the inadequacy of critical infrastructure to withstand the forces of natural calamities and the lack of mitigation strategies when they occur on the part of emergency-related organizations, industries, and communities. If the emergency-related agencies could identify and fortify the vulnerable critical infrastructure in the preparedness stage, the damage and impacts can be significantly reduced. Therefore, it is important to develop a decision support system (DSS) for identifying region-specific mitigation strategies based on the inter-relationships between the infrastructure and associated industries and communities in the affected region. To establish effective mitigation strategies, relevant data were collected from the affected areas with respect to the technical, social, and economic impact levels. The data analysis facilitated identifying the major factors, such as vulnerability, criticality, and severity, for developing a DSS. Customized mitigation strategies that will help agencies prepare, respond, and recover according to the disaster response were suggested.

  • PDF

Seismic control of concrete rectangular tanks subjected to bi-directional excitation using base isolation, considering fluid-structure-soil interaction

  • Mohammad Hossein Aghashiri;Shamsedin Hashemi;Mohammad Reza Kianoush
    • Structural Engineering and Mechanics
    • /
    • v.92 no.1
    • /
    • pp.25-52
    • /
    • 2024
  • In the current paper, the various responses of concrete rectangular liquid storage containers under seismic load, each isolated by a lead-rubber bearing subjected to bi-directional earthquake forces are investigated. A parametric study is conducted to investigate the effects of isolation period, yield strength of the isolator and the effects of soil-foundation interaction for non-isolated and base-isolated tanks located on different soil types. In most cases, the value of base shear, base moment, wall displacement and hydrodynamic pressure is reduced by the effect of the isolators whose effective frequency is within the appropriate range. The sloshing displacement is amplified due to seismic isolation of the tanks for both tall and shallow tank configurations. Also, it is found that the seismic isolation technique is more efficient for the more flexible tank. Studying various soil types indicates that, unlike the responses of non-isolated tanks which change drastically for different soil types, the responses of base-isolated structures are less affected. Finally, it is observed that the variation in structural responses is not only related to the superstructure configuration and bearings properties but also depends on the earthquake specifications.

Capacity design by developed pole placement structural control

  • Amini, Fereidoun;Karami, Kaveh
    • Structural Engineering and Mechanics
    • /
    • v.39 no.1
    • /
    • pp.147-168
    • /
    • 2011
  • To ensure safety and long term performance, structural control has rapidly matured over the past decade into a viable means of limiting structural responses to strong winds and earthquakes. Nonlinear response history analysis requires rigorous procedure to compute seismic demands. Therefore the simplified nonlinear analysis procedures are useful to determine performance of the structure. In this investigation, application of improved capacity demand diagram method in the control of structural system is presented for the first time. Developed pole assignment method (DPAM) in structural systems control is introduced. Genetic algorithm (GA) is employed as an optimization tool for minimizing a target function that defines values of coefficient matrices providing the placement of actuators and optimal control forces. The ground acceleration is modified under induced control forces. Due to this, performance of structure based on improved nonlinear demand diagram is selected to threshold of nonlinear behavior of structure. With small energy consumption characteristics, semi-active devices are especially attractive solutions for limiting earthquake effects. To illustrate the efficiency of DPAM, a 30-story steel moment frame structure employing the semi-active control devices is applied. In comparison to the widely used linear quadratic regulation (LQR), the DPAM controller was shown to be just as effective and better in the reduction of structural responses during large earthquakes.

Seismic Response Analysis of Rectangular Tank with Base-Isolation System (구형 면진유체저장조의 지진시 거동해석)

  • 전영선;최인길;황신일;김진웅
    • Computational Structural Engineering
    • /
    • v.8 no.1
    • /
    • pp.107-113
    • /
    • 1995
  • Spent fuel storage pool should maintain its structural integrity and the safety of stored spent fuels against design earthquake load. In this study, the seismic response analysis of the pool with LRB isolation system is performed for two different earthquakes. To investigate the seismic response of the base isolated pool, the analysis results are compared with the responses of conventional type. In conclusion, the base-isolation system is effective to reduce the seismic forces transmitted to the superstructure and the responses, and to secure the safety of the storage pool and stored spent fuel.

  • PDF