• Title/Summary/Keyword: eccentric

Search Result 893, Processing Time 0.023 seconds

Comparison of Muscle Strength between Dominant and Non-dominant Sides of College Students in Their 20s according to Contraction Type (수축 형태에 따른 20대 대학생의 우세 측과 비우세 측의 근력비교)

  • Jong-Hyup Lee;Seung-Kyu Lee;Young-Sun Na;Jeong-Woo Jeon;Jae-Ho Yu;Ji-Heon Hong;Jin-Seop Kim;Dong-Yeop Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.47-53
    • /
    • 2024
  • Purpose : This study investigated the effects of concentric and eccentric contractions on muscle strength using an isokinetic dynamometer (ID) in college students in their 20s. It aimed to understand the impact of differences between the dominant and non-dominant sides on strength asymmetry and to elucidate the clinical implications of these differences to establish an appropriate posture and environment for patients. Methods : The experiment was conducted with 30 healthy adult participants. Prior to the experiment, participants underwent a warm-up targeting the shoulders, and efforts were made to eliminate factors that could potentially influence the measurement results. Subsequently, the maximum safe range of motion of shoulder joint abduction, extension, and flexion was measured using an isokinetic muscle function testing device. Muscle strength was assessed using concentric and eccentric contractions alternating between the dominant and non-dominant sides, and paired sample t-tests were used for the analysis. Results : There was no significant difference between bilateral peak torques for eccentric contraction in shoulder joint abduction, extension, and flexion (p>0.05). There was also no significant difference between bilateral peak torques for concentric contraction in shoulder joint abduction, extension and flexion (p>0.05). Conclusion : This study found no statistically significant difference in muscle strength between the dominant and non-dominant sides during concentric and eccentric contractions. However, previous studies have shown significant differences between the dominant and non-dominant sides during eccentric and concentric contractions during internal shoulder rotation in the general population, as well as significant differences in the upper trapezius muscle. Therefore, further research is needed to support the application of different intensities for bilateral muscle strengthening exercises in clinical practice.

Shear Behavior of Steel Eccentric Link Subject to Seismic Loads (철골 보 접합부재의 지진전단거동에 관한 연구)

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.3
    • /
    • pp.35-39
    • /
    • 1991
  • Concentrically braced frames are limited in their ability to absorb energy during an earthquake However by placing the bracing members eccentric to the beam column joints, an energy absorbing link unit is produced. The energy is absorbed by the link and / or columns deforming inelastically. Three models of a multistorey structure were analyzed using DRAIN-2D computer program .Three link lengths were used in the analyses, 7, 11 and 15 inches. The yield patterns are produced. However it is interesting to note the relative valuses of force and moment obtained.

  • PDF

THE HYDROMAGNETIC FLOW BETWEEN ECCENTRIC CYLINDERS WITH VELOCITY SLIP AT THE CYLINDER WALLS

  • Meena, S.;Kandaswamy, P.
    • Journal of applied mathematics & informatics
    • /
    • v.6 no.2
    • /
    • pp.487-502
    • /
    • 1999
  • The hydrodynamic flow between two eccentric cylinders is examined for small values of modified Reynolds number porosity parameter and the non-dimensional slip velocity parameter in the presence of a radial magnetic field. The stream function and the pres-sure distribution are calculated and the results are presented graph-ically.

Bifurcation Criterion in Eccentrically Compressed Rectangular Tubes (편심압축하중을 받는 사각튜브의 분기세장비)

  • 김천욱;한병기;정창현;김치균
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.6
    • /
    • pp.270-278
    • /
    • 1999
  • This paper describes the collapse characteristics of the rectangular tube under eccentric compressive load. Overall buckling stress and bifurcation criterion (slenderness ration)are investigated. modified secant formula(MSF) is proposed to decide overall buckling stress. The bifurcation criterion which can distinguish between the local and overall buckling mode shapes is suggest by equating the local and overall buckling stresses. Additionally the effect of initial imperfection on bifurcation criterion is investigated.

  • PDF

A Study on the eccentric machining of roller gear cam (롤러기어캠 편심 가공에 관한 연구)

  • 권병두;조승래;이춘만;정원지
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.251-254
    • /
    • 2000
  • In this paper, we developed an automated program for the modeling and manufacturing of three-dimensional roller gear cams. A computer program employing the theory of gearing and coordinate transformation is developed for synthesizing and animating cam mechanisms. A method using wire frame modeling and shading by triangular element is presented, and effectively used for modeling of example with reduced computation time. Then a module for generation NC program for a five-axis CMC machine to manufacture roller gear cam is established.

  • PDF

Modal analysis of eccentric shells with fluid-filled annulus

  • Jhung, Myung Jo;Jeong, Kyeong Hoon;Hwang, Won Gul
    • Structural Engineering and Mechanics
    • /
    • v.14 no.1
    • /
    • pp.1-20
    • /
    • 2002
  • Investigated in this study are the modal characteristics of the eccentric cylindrical shells with fluid-filled annulus. Theoretical method is developed to find the natural frequencies of the shell using the finite Fourier expansion, and their results are compared with those of finite element method to verify the validation of the method developed. The effect of eccentricity on the modal characteristics of the shells is investigated using a finite element modeling.

Performance analysis of scroll compressor considering eccentric mass of orbiting scroll (선회스크롤의 편심질량을 고려한 스크롤압축기의 성능해석)

  • 박승철;이진갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.605-614
    • /
    • 1999
  • Orbiting scroll mass center is different from the basic circle's for the normal involute profile. As for the orbiting scroll balanced conditions, the dynamic modeling are set up. The influences on sealing, reaction forces between the moving elements and forces from the moving elements to the compressor frame are analyzed in this paper. The simulation and experiment results are presented.

  • PDF

The Comparison of Effect of MC Intensity in Pain and ROM in Delayed Onset Muscle Soreness (미세전류 자극 강도에 따른 지연성 근육통의 통증과 관절가동범위에 미치는 영향)

  • Kim, Seun-Deuck;Park, Hye-Mi;Jung, Hwa-Su
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Purpose : We investigated the effects of microcurrent(MC) electrical stimulation on each intensity($100{\mu}A,\;200{\mu}A,\;500{\mu}A$ - 30pps frequency was same) on delayed onset muscle soreness(DOMS). Methods : Subjects were assigned randomly divided into three groups of eight for three different treatment protocoals($100{\mu}A,\;200{\mu}A,\;500{\mu}A$-experimental groups). Twenty-four healthy males and females subjects were participated in this study. All subjects performed eccentric exercise of elbow flexor(biceps brachii) until exhausted. The measured items of elbow flexor muscle strength were Nicholas Manual Muscle Taster(NMMT). The measured items of elbow joint range of motion ROM) were Goniometer. The measured items of elbow flexor muscle pain were visual analogue scale(VAS). Treatment were applied at 30 minute exercise after and again at 24 hours and at 48 hours and at 72 hours after. Measurements were taken after treatment. Analysis of Results using repeated measures analysis of variance(ANOVA) and post hoc tests were as follows: two-way ANOVA with repeated measurement for muscle strength, flexion ROM, extension ROM and VAS. Results : This results showed eccentric exercise casused DOMS, DOMS response to eccentric exercise were reduces by microcurrent therapy. DOMS was significant decreased at $100{\mu}A,\;200{\mu}A,\;500{\mu}A$. Muscle strength was significant difference at all intensity. Elbow flexion ROM was significant difference at all intensity but elbow extension ROM was insignificant difference at all intensity. VAS score was significant difference at $100{\mu}A$ and $500{\mu}A$ but insignificant difference at $200{\mu}A$. All experimental groups showed insignificant difference with all intensity MENS. Conclusion : These findings indicate that microcurrent therapy is had effect on recovery from exercise induced muscle damage. In our's suggestion, microcurrent therapy is particularly more appropriate therapeutic modality.

The effect of eccentricity between gear and housing in involute gear pump (인벌류트 기어펌프의 기어 편심에 따른 유동특성)

  • Kim, Sung-Hoon;Son, Hye-Min;Lee, Jae-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.631-637
    • /
    • 2013
  • The characteristics of involute gear pump with eccentric gap between gear tip and housing have been studied in terms of volumetric flow rate and/or flow efficiency. The analysis has been done with FLUENT/R-13 employing with k-e model for the turbulent flow under the given conditions of rotational velocity, gap distance and outlet pressure. The effect of parameters continues to be shown for the eccentric gear as same as for the concentric gear such that the volumetric flow rate (volumetric efficiency) increases as the increases of rotational velocity and decrease of gap distance and of outlet pressure. In the meantime, the shape of pressure build-up appears to be exponentially increase as gap distance decreases at upstream position. The pressure is rapidly developing in the upstream and remains almost constant thereafter in the downstream of circumferential flow path. This typical characteristics becomes more profound as eccentricity increases. The pump performance for the eccentric gear pump with minimum gap distance shows better than its concentric counterpart. However, it shows not for the concentric pump with minimum gap distance. Therefore, the gap reduction due to eccentricity may be positive for pump performance.