• 제목/요약/키워드: earthquake sequence

검색결과 39건 처리시간 0.022초

경주 지진 여진의 진원 깊이 연구 (Hypocentral Depth Determination of Gyeongju Earthquake Aftershock Sequence)

  • 정태웅;모하메드 자파르
    • 지구물리와물리탐사
    • /
    • 제20권1호
    • /
    • pp.49-55
    • /
    • 2017
  • 2016년 9월 12일 경주지진(규모 5.8)의 103개 여진의 진원 깊이를 HYPO71과 HYPOINVERSE를 이용한 진원 재결정을 통하여 역산하였다. 한반도에서 지역에 따라 변화하는 속도를 나타내는 7개 모델을 비교한 분석에서 전구간 선형가중치를 둔 HYPO71이 HYPOINVERSE에 비해 진앙 부근 모델이 잔차가 더 적은, 바람직한 결과를 얻었다. 규모가 큰 지진과 S파 진앙거리가 짧은 지진자료는 진원깊이 불확실성이 비교적 작게 관찰되었다.

Elasto-plastic time history analysis of a 117-story high structure

  • Wu, Xiaohan;Li, Yimiao;Zhang, Yunlei
    • Computers and Concrete
    • /
    • 제19권1호
    • /
    • pp.7-17
    • /
    • 2017
  • In Chinese Design Codes, for super high-rise buildings with complex structural distribution, which are regarded as code-exceeding buildings, elasto-plastic time history analysis is needed to validate the requirement of "no collapse under rare earthquake". In this paper, a 117-story super high-rise building is discussed. It has a height of 597 m and a height-width ratio of 9.5, which have both exceeded the limitations stipulated by the Chinese Design Codes. Mega columns adopted in this structure have cross section area of about $45m^2$ at the bottom, which is infrequent in practical projects. NosaCAD and Perform-3D, both widely used in nonlinear analyses, were chosen in this study, with which two model were established and analyzed, respectively. Elasto-plastic time history analysis was conducted to look into its seismic behavior, emphasizing on the stress state and deformation abilities under intensive seismic excitation.From the comparisons on the results under rare earthquake obtained from NosaCAD and Perform-3D, the overall responses such as roof displacement, inter story drift, base shear and damage pattern of the whole structure from each software show agreement to an extent. Besides, the deformation of the structure is below the limitation of the Chinese Codes, the time sequence and distribution of damages on core tubes are reasonable, and can dissipate certain inputted energy, which indicates that the structure can meet the requirement of "no collapse under rare earthquake".

Comparison of seismic progressive collapse distribution in low and mid rise RC buildings due to corner and edge columns removal

  • Karimiyan, Somayyeh
    • Earthquakes and Structures
    • /
    • 제18권5호
    • /
    • pp.649-665
    • /
    • 2020
  • One of the most important issues in structural systems is evaluation of the margin of safety in low and mid-rise buildings against the progressive collapse mechanism due to the earthquake loads. In this paper, modeling of collapse propagation in structural elements of RC frame buildings is evaluated by tracing down the collapse points in beam and column structural elements, one after another, under earthquake loads and the influence of column removal is investigated on how the collapse expansion in beam and column structural members. For this reason, progressive collapse phenomenon is studied in 3-story and 5-story intermediate moment resisting frame buildings due to the corner and edge column removal in presence of the earthquake loads. In this way, distribution and propagation of the collapse in progressive collapse mechanism is studied, from the first element of the structure to the collapse of a large part of the building with investigating and comparing the results of nonlinear time history analyses (NLTHA) in presence of two-component accelograms proposed by FEMA_P695. Evaluation of the results, including the statistical survey of the number and sequence of the collapsed points in process of the collapse distribution in structural system, show that the progressive collapse distribution are special and similar in low-rise and mid-rise RC buildings due to the simultaneous effects of the column removal and the earthquake loads and various patterns of the progressive collapse distribution are proposed and presented to predict the collapse propagation in structural elements of similar buildings. So, the results of collapse distribution patterns and comparing the values of collapse can be utilized to provide practical methods in codes and guidelines to enhance the structural resistance against the progressive collapse mechanism and eventually, the value of damage can be controlled and minimized in similar buildings.

영구지반변형이 매설된 하수도관로 성능에 미치는 영향 (Permanent Ground Deformation Effects on Underground Wastewater Pipeline Performance)

  • 전상수
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.284-289
    • /
    • 2016
  • 최근 주요 사회기반시설물로 이루어진 뉴질랜드 Christchurch 지역에 상당히 큰 지반운동을 유발하고 짧은 기간에 연속적으로 발생한 지진충격의 전례 없는 사례가 발생하였으며 특히 액상화 지역에서 발생된 영구지반변형과 하수도관 손상에 관한 방대하고 정확한 자료가 수집되었다. 본 연구에서는 이 지역의 2011년 2월 22일 지진규모($M_w$) 6.2 지진발생 후 얻어진 하수도관 길이 및 손상갯수와 영구지반변형지역에서 지진발생 전후에 얻어진 높은 해상도의 라이다데이터로부터 계산된 지반 각변형과 횡방향 지반변형률의 자료를 바탕으로 지리정보체계(GIS) 모델링과 선형회귀분석을 수행하여 도기와 콘크리트 하수도관의 손상율(손상갯수/1km)을 산정하였다. 연구 결과 두 매설관 모두 지반 각변형과 횡방향 지반변형률에 따라 유사한 경향으로 손상됨을 알 수 있으며 강성이 더 큰 콘크리트 하수도관의 손상이 더 작게 나타남을 알 수 있으며 이러한 선형회귀분석 결과는 추후 지진 시 발생할 수 있는 영구지반변형으로 인한 도기와 콘크리트 하수도관 손상율 예측에 유용하게 사용될 수 있다.

Comparison of seismic progressive collapse distribution in low and mid rise RC buildings due to corner and edge columns removal

  • Karimiyan, Somayyeh
    • Earthquakes and Structures
    • /
    • 제18권6호
    • /
    • pp.691-707
    • /
    • 2020
  • One of the most important issues in structural systems is evaluation of the margin of safety in low and mid-rise buildings against the progressive collapse mechanism due to the earthquake loads. In this paper, modeling of collapse propagation in structural elements of RC frame buildings is evaluated by tracing down the collapse points in beam and column structural elements, one after another, under earthquake loads and the influence of column removal is investigated on how the collapse expansion in beam and column structural members. For this reason, progressive collapse phenomenon is studied in 3-story and 5-story intermediate moment resisting frame buildings due to the corner and edge column removal in presence of the earthquake loads. In this way, distribution and propagation of the collapse in progressive collapse mechanism is studied, from the first element of the structure to the collapse of a large part of the building with investigating and comparing the results of nonlinear time history analyses (NLTHA) in presence of two-component accelograms proposed by FEMA_P695. Evaluation of the results, including the statistical survey of the number and sequence of the collapsed points in process of the collapse distribution in structural system, show that the progressive collapse distribution are special and similar in low-rise and mid-rise RC buildings due to the simultaneous effects of the column removal and the earthquake loads and various patterns of the progressive collapse distribution are proposed and presented to predict the collapse propagation in structural elements of similar buildings. So, the results of collapse distribution patterns and comparing the values of collapse can be utilized to provide practical methods in codes and guidelines to enhance the structural resistance against the progressive collapse mechanism and eventually, the value of damage can be controlled and minimized in similar buildings.

Shear performance and design recommendations of single embedded nut bolted shear connectors in prefabricated steel-UHPC composite beams

  • Zhuangcheng Fang;Jinpeng Wu;Bingxiong Xian;Guifeng Zhao;Shu Fang;Yuhong Ma;Haibo Jiang
    • Steel and Composite Structures
    • /
    • 제50권3호
    • /
    • pp.319-336
    • /
    • 2024
  • Ultra-high-performance concrete (UHPC) has attracted increasing attention in prefabricated steel-concrete composite beams as achieving the onsite construction time savings and structural performance improvement. The inferior replacement and removal efficiency of conventional prefabricated steel-UHPC composite beams (PSUCBs) has thwarted its sustainable applications because of the widely used welded-connectors. Single embedded nut bolted shear connectors (SENBs) have recently introduced as an attempt to enhance demountability of PSUCBs. An in-depth exploration of the mechanical behavior of SENBs in UHPC is necessary to evidence feasibilities of corresponding PSUCBs. However, existing research has been limited to SENB arrangement impacts and lacked considerations on SENB geometric configuration counterparts. To this end, this paper performed twenty push-out tests and theoretical analyses on the shear performance and design recommendation of SENBs. Key test parameters comprised the diameter and grade of SENBs, degree and sequence of pretension, concrete casting method and connector type. Test results indicated that both diameters and grades of bolts exerted remarkable impacts on the SENB shear performance with respect to the shear and frictional responses. Also, there was limited influence of the bolt preload degrees on the shear capacity and ductility of SENBs, but non-negligible contributions to their corresponding frictional resistance and initial shear stiffness. Moreover, inverse pretension sequences or monolithic cast slabs presented slight improvements in the ultimate shear and slip capacity. Finally, design-oriented models with higher accuracy were introduced for predictions of the ultimate shear resistance and load-slip relationship of SENBs in PSUCBs.

Collapse failure mechanism of subway station under mainshock-aftershocks in the soft area

  • Zhen-Dong Cui;Wen-Xiang Yan;Su-Yang Wang
    • Geomechanics and Engineering
    • /
    • 제36권3호
    • /
    • pp.303-316
    • /
    • 2024
  • Seismic records are composed of mainshock and a series of aftershocks which often result in the incremental damage to underground structures and bring great challenges to the rescue of post-disaster and the repair of post-earthquake. In this paper, the repetition method was used to construct the mainshock-aftershocks sequence which was used as the input ground motion for the analysis of dynamic time history. Based on the Daikai station, the two-dimensional finite element model of soil-station was established to explore the failure process of station under different seismic precautionary intensities, and the concept of incremental damage of station was introduced to quantitatively analyze the damage condition of structure under the action of mainshock and two aftershocks. An arc rubber bearing was proposed for the shock absorption. With the arc rubber bearing, the mode of the traditional column end connection was changed from "fixed connection" to "hinged joint", and the ductility of the structure was significantly improved. The results show that the damage condition of the subway station is closely related to the magnitude of the mainshock. When the magnitude of the mainshock is low, the incremental damage to the structure caused by the subsequent aftershocks is little. When the magnitude of the mainshock is high, the subsequent aftershocks will cause serious incremental damage to the structure, and may even lead to the collapse of the station. The arc rubber bearing can reduce the damage to the station. The results can offer a reference for the seismic design of subway stations under the action of mainshock-aftershocks.

2016년 9월 경주지진 소고(小考) (Discussions on the September 2016 Gyeongju Earthquakes)

  • 이기화
    • 지구물리와물리탐사
    • /
    • 제20권3호
    • /
    • pp.185-192
    • /
    • 2017
  • 2016년 9월 12일 규모 5.8의 본진을 포함한 일련의 지진들이 경주에서 발생했다. 본진은 1905년 한반도에서 지진관측을 시작한 이래 반도 남부에서 발생한 최대의 지진으로서 양산단층이 명백한 활성단층임을 입증하였다. 콘래드 불연속면이 없는 단층의 한반도 지각 모델에 의한 경주지진들의 전진, 본진, 여진들의 평균깊이는 12.9 km로 콘래드 불연속면이 있는 2층 구조의 IASP91 모델에 의한 평균깊이보다 2.8 km 낮다. 경주지역에서 발생한 역사지진 및 계기지진들의 진앙분포는 주 단층인 양산단층과 부속 단층을 포함하는 양산단층계가 광범위한 파쇄대임을 시사한다. 규모 5.8의 경주지진에 수반한 지진들의 진앙분포는 양산단층계의 몇 단층들이 응력에너지의 방출에 관여하였음을 지시한다. 경주지진들의 주요 지진들이 지표가 아닌 10 km 이하에서 발생한 것은 양산단층계의 심부 활성단층들의 분포를 연구할 필요성을 제기한다. 경주지역의 지진자료에 근거하여 추정한 이 일대의 최대지진의 규모는 7.3이다. 한반도의 가장 완전한 1978년 이후의 지진자료를 이용하여 추정한 경주지역의 규모 5.0, 6.0, 7.0을 초과하는 지진들의 재현간격은 각기 80년, 670년, 그리고 5,900년이다. 2016년 9월 경주지진들은 본질적으로 판내부지진활동의 범주에 속하며 2011년 3월 11일 일본해구에서 발생한 판경계지진횔동인 동일본대지진과는 무관하다.

구조물 손상 탐지를 위한 경 방향 모드 압전 오실레이터 센서 개발 (Development of a Lateral Mode Piezoelectric Oscillator Sensor to Detect Damages in a Structure)

  • 노용래;김동영
    • 한국지진공학회논문집
    • /
    • 제10권6호
    • /
    • pp.125-132
    • /
    • 2006
  • 본 논문에서는 사회기반시설의 손상탐지를 위한 경 방향모드 압전 오실레이터의 가능성을 연구하였다. 경 방향 모드 오실레이터 센서는 구조물의 주요부에 부착된 경 방향 모드 압전소자와 피드백 오실레이터 회로로 구성되어있다. 구조물의 손상은 구조물의 임피던스를 변화를 야기 시키며, 그 결과로 구조물의 공진 주파수가 변화하게 된다. 오실레이터 센서는 간단한 방법으로 이 공진 주파수 변화를 연속적으로 관측할 수 있다. 본 연구에서는 알루미늄 시편에 크랙의 크기와 개수를 인위적으로 변화 시키면서, FEM해석과 실험을 통해 경 방향 모드 압전 오실레이터 센서의 적용 가능성을 증명 하였다.

Optimum control system for earthquake-excited building structures with minimal number of actuators and sensors

  • He, Jia;Xu, You-Lin;Zhang, Chao-Dong;Zhang, Xiao-Hua
    • Smart Structures and Systems
    • /
    • 제16권6호
    • /
    • pp.981-1002
    • /
    • 2015
  • For vibration control of civil structures, especially large civil structures, one of the important issues is how to place a minimal number of actuators and sensors at their respective optimal locations to achieve the predetermined control performance. In this paper, a methodology is presented for the determination of the minimal number and optimal location of actuators and sensors for vibration control of building structures under earthquake excitation. In the proposed methodology, the number and location of the actuators are first determined in terms of the sequence of performance index increments and the predetermined control performance. A multi-scale response reconstruction method is then extended to the controlled building structure for the determination of the minimal number and optimal placement of sensors with the objective that the reconstructed structural responses can be used as feedbacks for the vibration control while the predetermined control performance can be maintained. The feasibility and accuracy of the proposed methodology are finally investigated numerically through a 20-story shear building structure under the El-Centro ground excitation and the Kobe ground excitation. The numerical results show that with the limited number of sensors and actuators at their optimal locations, the predetermined control performance of the building structure can be achieved.