• 제목/요약/키워드: early voltage

검색결과 169건 처리시간 0.03초

A Brief Introduction to the Transduction of Neural Activity into Fos Signal

  • Chung, Leeyup
    • 한국발생생물학회지:발생과생식
    • /
    • 제19권2호
    • /
    • pp.61-67
    • /
    • 2015
  • The immediate early gene c-fos has long been known as a molecular marker of neural activity. The neuron's activity is transformed into intracellular calcium influx through NMDA receptors and L-type voltage sensitive calcium channels. For the transcription of c-fos, neural activity should be strong enough to activate mitogen-activated protein kinase (MAPK) signaling pathway which shows low calcium sensitivity. Upon translation, the auto-inhibition by Fos protein regulates basal Fos expression. The pattern of external stimuli and the valence of the stimulus to the animal change Fos signal, thus the signal reflects learning and memory aspects. Understanding the features of multiple components regulating Fos signaling is necessary for the optimal generation and interpretation of Fos signal.

The performance and quality improvement of Lithium ion Batteries

  • Xiaoping Li
    • 한국전기화학회:학술대회논문집
    • /
    • 한국전기화학회 2004년도 전지기술심포지움
    • /
    • pp.75-108
    • /
    • 2004
  • The market, development and trend of Lithium ion Batteries in China are introduce briefly. Early, Chinese manufactories were busy to expand and many new battery factories have been built up. Now, the relatively large companies pay more attentions on comprehensive quality improvement, therefore the production processing and facilities have been also modified in some extent. The recent technology progresses focus on High capacity (energy density), High rate, High average voltage, High safety, High temperature properties, Long cycle life, Low temperature properties, Low self discharge, Low cost, Super-large, Super-small, Super-thin, Consistency, Customization, and Environment friendly processing, simply $H_5L_4S_3C_2E_1$. Lithium ion polymer batteries which all batteries packaged with soft lamination film are named as in China have a quick growth and emphasized here because of their advantages ins $H_5L_4S_3C_2E_1$ for which it is quite difficult to be realized at the same time. Some of research works such as listed above are introduced. The other contends related to application trend of Lithium ion batteries and projects carrying out are also included.

  • PDF

FDTD Analsysis of Lightning-Induced Voltages on Shielded Telecommunication Cable with Multipoint Grounding

  • Ju, Jae-Cheol;Lee, Hyun-Young;Park, Dong-Chul;Chung, Nak-Sam
    • Journal of electromagnetic engineering and science
    • /
    • 제1권1호
    • /
    • pp.88-94
    • /
    • 2001
  • In this paper, the lightning-induced voltages on shielded twisted-pair wires with multipoint grounding on cable sheath are calculated by using finite-difference time domain (FDTD) method. The equivalent single-wire line that represents a bundle of twisted-pair wires is adopted for computational efficiency. A finitely conducting ground is also taken into account in both lightning electromagnetic field calculations and surge propagation along the shielded cable for a practical simulation. It is found that multipoint additional grounding on cable sheath provides more shielding effectiveness especially in the early time response of the lightning-induced voltages. From this study, the requirements for lighting surge protection devices in a telecommunication subscriber cab1e can be established.

  • PDF

탄소강재 용접부의 온도분포에 관한 연구 (A Study on the Temperature Distribution of Welding Zone in Carbon Steel)

  • 남궁재관;홍재학
    • 한국안전학회지
    • /
    • 제5권3호
    • /
    • pp.33-38
    • /
    • 1990
  • In this study, the transient temperature distribution of welded zone was analyzed by Finite Element Method for the optimal design of weldment. This study was carried out for the steel plate 8mm thick, 100mm wide, 100mm long that butt weld. The weld was made with a heat input of 2,250 joule/cm(arc current : 180 amperes ; arc voltage :25 volts ; and arc travel steed : 0.28 cm/sec). In the analysis of temperature, cooling in the welded zone by the conduction between materal was almost completed at 600 sec when a unique temperature field was formed. after this, the material was gradually cooled by the heat transfer to the circumference. In the early phase the temperature in base metal zone is little changed. but after the rise in temperature the whole area is cooled gradually.

  • PDF

복합 스트레스에 의한 비정질 실리콘 박막 트랜지스터에서의 가속열화 현상 연구 (A Study of the Acclerated Degradation Phenomena on th Amorphous Silicon Thin Film Transistors with Multiple Stress)

  • 이성규;오창호;김용상;박진석;한민구
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1121-1127
    • /
    • 1994
  • The accelerated degradation phenomena in amorphous silicon thin film transistors due to both electrical stress and visible light illumination under the elevated temperature have been investigated systematically as a function of gate bias, light intensity, and stress time. It has been found that, in case of electrical stress, the thrshold voltage shifts of a-Si:H TFT's may be attributed to the defect creation process at the early stage, while the charge trapping phenomena may be dominant when the stressing periods exceed about 2 hours. It has been also observed that the degradation in the device characteristics of a-Si:H TFT's is accelerated due to multiple stress effects, where the defect creation mechanism may be more responsible for the degradation rather than the charge trapping mechanism.

가스분석을 이용한 변압기의 이상진단 알고리즘 연구 (A Study of the Preventive Diagnostic Algorithm of Gas in Oil for Power Transformer)

  • 최인혁;권동진;정길조;유연표;선종호;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1903-1905
    • /
    • 2000
  • Power transformers have a tendency of ultra-high voltage capacity as power demand increases day after day KEPCO also will have plan to supply transmission power from 345KV to 765KV in the early of 2000. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important in power transformers because of economic loss and its spreading effect. This study presents the algorithm for transformer oil analysis used KEPCO code, IEC code, gas pattern method and Dornenburg & Roger Ratio method. We also describe the MMI display of expert system programmed by Element Expert Tool(Neuron Data Inc.).

  • PDF

마더 웨이브렛에 따른 RMS값 계산의 정확도 검토에 관한 연구 (A study on the Precision of RMS value calculation using Mother Wavelet)

  • 오경섭;김철환;박남옥;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.265-267
    • /
    • 2003
  • The wavelet transform(WT) has been extensively applied in solving many problems in applied science and engineering following its introduction in early 1980's. The WT analyzes a signal in a changeable frequency range by employing a moving window whereby along time window is used to obtain low frequency information and short time window is used to obtain high frequency information. In this paper, after various fault types in 154 KV transmission system was simulated by using EMTP, and the RMS values by changing Mother wavelet was calculated by applying wavelet transform to the simulated voltage and current signal.

  • PDF

과천 송전선로 전자계 측정 (Measurement of Magnetic and Electric Field from Kwachun Power Transmission Lines)

  • 김덕원;유창용
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.353-356
    • /
    • 1996
  • Early this year the construction of new high voltage power lines have been forced to stop due to the demonstration of residents in Kwa-chun. According to mutual agreement between the residents and Korea Electric Power Corporation, electromagnetic field(EMF) from present power lines was measured and EMF after completion of new power lines was estimated. The results show that EMF near power lines Is relatively low, and EMFnear electric substation is quite high due to the short distance between the power lines and ground. For 4 conduction 345kV line, magnetic field decreases to 3mG at the distance of 50m from the power line.

  • PDF

대형변압기 절연상태 평가 (Assessment of Insulation Condition in Large Transformers)

  • 김희동;공태식;이영준;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.499-502
    • /
    • 2004
  • In order to detect of insulation problems an early, transformer has to be performed the several tests. The ac current and tan6 of transformer winding insulation were investigated by Schering bridge. Partial discharge(PD) tests are used to evaluate the insulation condition of transformer. The moisture content measurement was conducted using RVM(recovery voltage meter). The RVM test can show that the problem is affecting the paper insulation of transformer. The value of moisture content was 2.3% in main transformer. The insulations of four transformers were judged to be in good condition.

  • PDF

Ag(100) 기판위에 증착된 Nb Cluster에 관한 STM연구

  • 윤홍식;유미애;한권환;이준희;양경득;여인환
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.140-140
    • /
    • 2000
  • The initial growth mode of Nb on Ag(11) in sub-monolayer regime and the influence of subsequent 520K annealing are studied using UHV Scanning Tunneling Microscopy. E-beam evaporated Nb is deposited onto the substrate at RT, and STM measurements are carried out at RT and 78 K. With Nb being immiscible in bulk Ag, 3D islands formation begins at early stage and no particular ordered structure is found. After annealing to 520K, most of islands are disappeared from terrace. There exist 2 possibilities. : (1) Diffusion of Nb into the 2nd or 3rd layer of Ag substrate or (2) agglomeration of Nb on Ag at higher temperature. A model will be given to explain the evidence. In addition, we investigated the change of STM image according to bias voltage depending on island size. Possible physical mechanism responsible for such behavior together with interaction between Nb islands and reactive gases will be also discussed.

  • PDF