• 제목/요약/키워드: early voltage

검색결과 169건 처리시간 0.036초

만성 교약성 심낭염의 외과적 치료 (Surgical Treatment of Chronic Constrictive Pericarditis)

  • 강면식
    • Journal of Chest Surgery
    • /
    • 제22권1호
    • /
    • pp.67-73
    • /
    • 1989
  • Forty two patients with chronic constrictive pericarditis, who were admitted to the Yonsei University College of medicine over a period of 18 years from January, 1970 to August, 1988, were analyzed retrospectively. Mean age of the patient was 33.5 year ranging from 6.8 to 60 years old. Male to female ratio was 1.3 to 1. Twenty-one cases [50%] were tuberculous origin [based on either associated pulmonary tuberculosis and/or caseous necrosis in thickened pericardial specimen] and 17 cases [40.5%] were idiopathic [non specific chronic inflammatory change was considered to be idiopathic]. Dyspnea on exertion was evident in 30 cases [71.4%] and abdominal distention in 21 cases [50%]. On physical examination, hepatomegaly [83.3%], neck vein distention [54.8%], distant heart sound [47.6%] and ascites were found. Thirty-nine patients showed low voltage of QRS and/or T wave flattening or inversion on EKG. Thirty-one cases had undergone cardiac catheterization which showed data compatible with chronic constrictive pericarditis. Midsternostomy group [n=15] had shown the most remarkable CVP decline [12.20 mmHg] as compared with bilateral submammary incision group [n=25, 8.96 mmHg] and left thoracotomy group [n=2, 7.75 mmHg] but difference was not significant statistically There was four early death among 42 patients [9.5%] including 3 cases of left ventricular failure and one cardiac tamponade. Main postoperative complications were wound infection [6 cases] and arrhythmia [3 cases]. Follow-up of 24 patients [mean; 55.3 months, ranging from 2 months to 155 months] revealed good functional status.

  • PDF

Investigation of Degradative Signals on Outdoor Solid Insulators Using Continuous Wavelet Transform

  • Uzunoglu, Cengiz Polat
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.683-689
    • /
    • 2016
  • Most outdoor solid insulators may suffer from surface degradations due to non-stationary currents that flow on the insulator surface. These currents may be classified as leakage, discharge and tracking currents due to their disturbing potencies respectively. The magnitude of these currents depends on the degree of the contamination of surface. The leakage signals are followed by discharge signals and tracking signals which are capable of forming carbonized tracking paths on the surface between high voltage and earth contacts (surface tracking). Surface tracking is one of the most breakdown mechanisms observed on the solid insulators, especially polymers which may cause severely reduced lifetime. In this study the degradations observed on polyester resin based insulators are investigated according to the IEC 587 Inclined Plane Test Standard. The signals are monitored and recorded during tests until surface tracking initiated. In order to prevent total breakdown of an insulator, early detection of tracking signals is vital. Continuous Wavelet Transform (CWT) is proposed for classification of signals and their energy levels observed on the surface. The application of CWT for processing and classification of the surface signals which are prone to display high frequency oscillations can facilitate real time monitoring of the system for diagnosis.

Isolation and characterization of two phototropins in the freshwater green alga, Spirogyra varians (Streptophyta, Zygnematales)

  • Lee, Ji Woong;Kim, Gwang Hoon
    • ALGAE
    • /
    • 제32권3호
    • /
    • pp.235-244
    • /
    • 2017
  • Freshwater algae living in shallow waters have evolved various photomovement to stay in the optimum light condition for survival. Previous action-spectra investigations showed that Spirogyra filaments have phototropic movement in blue light. To decipher the genetic control of phototropic movement, two phototropin homologues were isolated from Spirogyra varians, and named SvphotA and SvphotB. Both phototropins have similar molecular structure consisted of two light-oxygen-voltage domains (LOV1, LOV2) and a serine / threonine kinase domain. SvphotA and SvphotB had 48.7% sequence identity. Phylogenetic analysis showed SvphotA and SvphotB belong to different clades suggesting early divergence, possibly before the divergence of land plants from the Zygnematales. Quantitative PCR and northern blot analysis showed that SvphotA and SvphotB responded differently to red and blue light. SvphotA was consistently expressed in the dark and in blue light, while SvphotB was expressed only when the plants were exposed to light. When the filaments were exposed to red light, SvphotA was significantly downregulated whereas SvphotB was highly upregulated. These results suggest that the two phototropins may have different roles in the photoresponse in S. varians.

The Role of Enzyme Replacement Therapy in Fabry Disease in Cardiology Perspective

  • Hongo, Kenichi
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • 제4권1호
    • /
    • pp.21-25
    • /
    • 2018
  • Fabry disease is a hereditary lysosomal storage disorder caused by the reduction or absence of lysosomal enzyme alpha-galactosidase A and the accumulation of glycosphingolipids, such as globotriaosylceramide (Gb3), in various organs, including the heart. The prevention of cardiac involvement in Fabry disease can only be achieved by enzyme replacement therapy (ERT), and the method of assessing the efficacy of ERT should be confirmed. Changes in the electrocardiogram, such as the shortening of PQ interval, prolongation of QTc and repolarization abnormalities as well as left ventricular hypertrophy in voltage criteria, can be used to identify Fabry disease patients; however, the usefulness of electrocardiograms for evaluating the efficacy of ERT is limited. The assessment of left ventricular hypertrophy using echocardiography has been established to evaluate the efficacy of ERT during long-term period. A new technique involving speckled tracking method might be useful for detecting early cardiac dysfunction and identifying the effect of ERT for a relatively short period. The estimation of left ventricular hypertrophy using cardiac magnetic resonance (CMR) is also useful for assessing the efficacy of ERT. Identifying late gadolinium enhancement in CMR may affect the effectiveness of ERT, and the new technique of T1 mapping might be useful for monitoring the accumulation of Gb3 during ERT. Histopathology in cardiac biopsy specimens is another potentially useful method for identifying the accumulation of GB3; however, the use of histopathology to evaluate of the efficacy of ERT is limited because of the invasive nature of an endomyocardial biopsy.

펄스 Nd:YAG 레이저를 이용한 모터용 스테이터 적층코어의 용접특성 [ I ] - 레이저 용접성에 미치는 가공변수의 영향 - (The Weldability of Laminated Stator Core for Motor by Pulsed Nd:YAG Laser [ I ] - The Effect of Processing Parameter on Weldability of Laser -)

  • 김종도;유승조;김장수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.629-635
    • /
    • 2006
  • Manufacture of motor by laser has been studying realization that was demands on market for lightening and miniaturization. Moreover. early in the 1980s. manufacture of parts for automobiles by laser welding was already successfully introduced. The purpose of this study was to develop production technology of the high quality laminated stator core for motor by pulsed Nd:YAG laser heat source. In the event of adjusting defocus and voltage to control humping in laser welding of the laminated core. sound bead could be obtained. but deep penetration was not. Therefore. explosive evaporating plasma was controlled by adjustment of peak power on pulse width. Particularly, because explosive evaporating plasma induced high peak power, made molten metal in keyhole scatter. a suitable adjustment of peak power was required to obtain sound bead. As a results of experiment. sound bead and deep penetration could be obtained.

초고압 XLPE 케이블용 조립형 직선 접속함을 모의한 계면질서의 부분방전 패턴 연구 (A Study of Partial Discharge Patterns On the Simulated Interface of Prefabricated Joint for Ultra Power Cable)

  • 백주흠;김정년;신두성;이창영;김충식;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1102-1104
    • /
    • 1999
  • It is very essential to find out defects and remove them in the insulation at the early stage because the defects in the insulation induce PD which deteriorates the material, resulting in the breakdown. In the real application of high voltage, the interface of the different insulation is the weakest place for both electrical and mechanical aspects. In this paper, characteristics of PD caused by the artificial defects, such as metallic particles, voids and moist fibers, at the interfaces of the cable joint (PJB) were investigated using the specially designed electrode system.

  • PDF

초초고압 CV Cable용(用) 조립형 직선 접속함에서의 Stress Relief Cone 계면압력 최적화에 관한 연구 (A Study on the Optimization of Interfacial Pressure for the Stress Relief Cone in the Ultra-High Voltage Level Prefabricated Type Joint Box)

  • 백주흠;백승엽;이수길;허근도;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1614-1616
    • /
    • 1998
  • Insulation performance of major components of prefabricated joint such as epoxy insulation unit and premolded rubber cone are guaranteed by material selection design and proper manufacturing. On the other hand insulation performance of the interfaces between the premolded rubber cone and the epoxy insulation unit and the cable insulation is maintained by keeping the premolded rubber cone to close contact with such insulation by spring. Electric characteristics of a interface depend on the contact pressure, but the required characteristics are assured so far as a proper contact pressure is maintained. In this report, the interfacial pressure by pressure sensors both in the early stage and after heating cycle were measured and the simulation by FEM program were presented. The comparison of these two results show that interfacial pressure could be controlled optimally by changing the spring length and lubricant state of the interface.

  • PDF

Nanofabrication of Microbial Polyester by Electrospinning Promotes Cell Attachment

  • Lee, Ik-Sang;Kwon, Oh-Hyeong;Wan Meng;Kang, Inn-Kyu;Yoshihiro Ito
    • Macromolecular Research
    • /
    • 제12권4호
    • /
    • pp.374-378
    • /
    • 2004
  • The biodegradable and biocompatible poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV), a copolymer of microbial polyester, was fabricated as nanofibrous mats by electrospinning. Image analysis of the electrospun nanofibers fabricated from a 2 wt% 2,2,2-trifluoroethanol solution revealed a unimodal distribution pattern of fiber diameters with an observed average diameter of ca. 185 nm. The fiber diameter of electrospun fabrics could be controlled by adjusting the electro spinning parameters, including the solvent composition, concentration, applied voltage, and tip-to-collector distance. Chondrocytes derived from rabbit ear were cultured on a PHBV cast film and an electrospun PHBV nano-fibrous mat. After incubation for 2 h, the percentages of attached chondrocytes on the surfaces of the flat PHBV film and the PHBV nanofibrous mat were 19.0 and 30.1 %, respectively. On the surface of the electrospun PHBV fabric, more chondrocytes were attached and appeared to have a much greater spreaded morphology than did that of the flat PHBV cast film in the early culture stage. The electro spun PHBV nanofabric provides an attractive structure for the attachment and growth of chondrocytes as cell culture surfaces for tissue engineering.

노화효과를 고려한 저전력 셀프 튜닝 디지털 시스템의 설계 (Design of a Low Power Self-tuning Digital System Considering Aging Effects)

  • 이진경;김경기
    • 대한임베디드공학회논문지
    • /
    • 제13권3호
    • /
    • pp.143-149
    • /
    • 2018
  • It has become ever harder to design reliable circuits with each nanometer technology node; under normal operation conditions, a transistor device can be affected by various aging effects resulting in performance degradation and eventually design failure. The reliability (aging) effect has traditionally been the area of process engineers. However, in the future, even the smallest of variations can slow down a transistor's switching speed, and an aging device may not perform adequately at a very low voltage. Therefore, circuit designers need to consider these reliability effects in the early stages of design to make sure there are enough margins for circuits to function correctly over their entire lifetime. However, such an approach excessively increases the size and power dissipation of a system. As the impact of reliability, new techniques in designing aging-resilient circuits are necessary to reduce the impact of the aging stresses on performance, power, and yield or to predict the failure of a system. Therefore, in this paper, a novel low power on-chip self-tuning circuit considering the aging effects has been proposed.

컨베이어벨트의 비접촉식 스틸코드파선 검사장치 개발 (Development of Non-contact Detector for Broken Cords of Steel-Cord Conveyor Belt)

  • 유재상;손봉호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2535-2537
    • /
    • 2000
  • In order to detect and monitor the broken cords of steel-cord belt from being damaged by impact of large lump of materials and the corrosion of steel cord, we developed a non-contact magnetic coil detection system. This measures the deterioration of reinforcing cables in steel cord conveyor belt which transport the ores in raw material plant. In this research, magnetic coil sensor of broken-cord detection system has exciting part and sensing part. The broken-cord detection system is operated by supplying a transmitter coil with electric power to generate magnetic field, and then the change of induced voltage is detected in each receiver coils due to resultant magnetic flux effected by the broken steel cords at the inside of the conveyor belt. By the informations such as the position and size of the broken steel cords obtained by SCBMS(Steel Cord Belt Monitoring System), it is expected that not only the span of belt life will be lengthened, but also this system can enable operators to plan scheduled maintenance and prevent the enlargement of damaged parts in steel cord belt at an early stage

  • PDF