• Title/Summary/Keyword: e-matrix

Search Result 1,439, Processing Time 0.025 seconds

Germination Promotion of Watermelon Seeds Using Solid Matrix Priming(SMP) Treatment (SMP 처리에 의한 수박종자의 발아촉진)

  • Kim, Sung-Eun;Song, Ji-Eun;Jung, Hee;Lee, Jung-Myung
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.344-346
    • /
    • 1998
  • Early emergence of watermelon seeds was markedly enhanced by SMP treatment though the final emergence percentage was not significantly influenced. Mixing ratios of 10:1:5 and 10:1:6 (seed : Micro-Cel E : water by weight) were found to be most effective in promoting the early emergence of watermelon seeds primed for 72 hrs at $25^{\circ}C$. Even though the hypocotyl elongation was slightly promoted by SMP treatment, the hypocotyl diameter remained uninfluenced. Among the cultivars tested, 'House-Ilpum' and 'Surowang' showed the best response to the SMP treatment.

  • PDF

The Absorbed Energy Characteristics of Gr/E Composite Tubes under Axial Collapse Load (축 압궤하중을 받는 Gr/E 복합재 튜브의 에너지 흡수특성)

  • 양현수;김영남;최흥환
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.2
    • /
    • pp.189-197
    • /
    • 2002
  • Composites have wide applications in aerospace vehicles and automobiles because of the inherent flexibility in their design lot improved material properties. Composite tubes in particular, are potential candidates for their use as energy absorbing elements in crashworthiness applications due to their high specific energy absorbing capacity and the stroke efficiency. Their failure mechanism however is highly complicated and rather difficult to analyze. This includes fracture in fibers, in the matrix and in the fiber-matrix interface in tension, compression and shear. The purpose of this study is to investigate the energy absorption characteristics of Gr/E(Graphite/Epoxy) tubes on static and impact tests. The collapse characteristics and energy absorption of a variety of tubes have been examined. Changes in the lay-up which increased the modulus increased the energy absorption of the tubes. Based on the test results, the following remarks can be made: Among CA15, CA00 and CA90 curves the CA90 tube exhibits the highest crush load throughout the whole crush process, and max load increases as interlaminar number increase. Among all the tubes type CC90 has the largest specific crushing stress of 52.60 kJ/kg which is much larger than other tubes.

On Enhancing Test and Evaluation Process of Weapon Systems Development using DSM-Based Risk and Safety Management (DSM기법에 의한 위험 및 안전 관리를 통해 무기체계 시험평가 프로세스의 개선에 관한 연구)

  • Sim, Sang Hyun;Lee, Jae-Chon
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.89-96
    • /
    • 2015
  • The weapon systems development has some distinct characteristics in that a big size of government budget (derived from national tax) has been expended frequently and the completion of the development projects seems to take long. Thus, the impact of the potential changes in the required operational capability on the development activities can induce some type of project risks. As such, proper management of project risk has been one of crucial subjects in the weapon systems development. Although a variety of methods can be considered, an approach based on the test and evaluation (T&E) process has been selected in this paper in order to appropriately handle those potential risks. In the study of the underlying T&E process, the safety consideration (for instance, explosiveness) of weapon systems is also included. To achieve the objective of the paper, a step-by-step procedure is first presented in the analysis of the T&E process. Then, to pursue some enhancement on the process, a set of necessary and useful activities are added in terms of risk and safety management. The resultant process is further analyzed and tailored based on a design structure matrix method. The case study of a tank development is also discussed.

A Direct Method to Derive All Generators of Solutions era Matrix Equation in a Petri Net - Extended Fourier-Motzkin Method -

  • Takata, Maki;Matsumoto, Tadashi;Moro, Seiichiro
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.490-493
    • /
    • 2002
  • In this paper, the old Fourier-Motzkin method (abbreviated as the old FH method from now on) is first modified to the form which can derive all minimal vectors as well as all minimal support vectors of nonnegative integer homogeneous solutions (i.e., T-invariants) for a matrix equation $Ax=b=0^{m{\times}1}$, $A\epsilonZ^{m{\times}n}$ and $b\epsilonZ^{m{\times}1}$, of a given Petri net, where the old FM method is a well-known and direct method that can obtain at least all minimal support solutions for $Ax=0^{m{\times}1}$ from the incidence matrix . $A\epsilonZ^{m{\times}n}$, Secondly, for $Ax=b\ne0^{m{\times}n}$ a new extended FM method is given; i.e., all nonnegative integer minimal vectors which contain all minimal support vectors of not only homogeneous but also inhomogeneous solutions are systematically obtained by applying the above modified FH method to the augmented incidence matrix $\tilde{A}$ =〔A,-b〕$\epsilon$ $Z^{m{\times}(n+1)}$ s.t. $\tilde{A}\tilde{x}$ = 0^{m{\times}1}$ However, note that for this extended FM method we need some criteria to obtain a minimal vector as well as a minimal support vector from both of nonnegative integer homogeneous and inhomogeneous solutions for Ax=b. Then those criteria are also discussed and given in this paper.

  • PDF

Inhibition of matrix metalloproteinases: a troubleshooting for dentin adhesion

  • de Moraes, Izadora Quintela Souza;do Nascimento, Ticiano Gomes;da Silva, Antonio Thomas;de Lira, Lilian Maria Santos Silva;Parolia, Abhishek;de Moraes Porto, Isabel Cristina Celerino
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.31.1-31.20
    • /
    • 2020
  • Matrix metalloproteinases (MMPs) are enzymes that can degrade collagen in hybrid layer and reduce the longevity of adhesive restorations. As scientific understanding of the MMPs has advanced, useful strategies focusing on preventing these enzymes' actions by MMP inhibitors have quickly developed in many medical fields. However, in restorative dentistry, it is still not well established. This paper is an overview of the strategies to inhibit MMPs that can achieve a long-lasting material-tooth adhesion. Literature search was performed comprehensively using the electronic databases: PubMed, ScienceDirect and Scopus including articles from May 2007 to December 2019 and the main search terms were "matrix metalloproteinases", "collagen", and "dentin" and "hybrid layer". MMPs typical structure consists of several distinct domains. MMP inhibitors can be divided into 2 main groups: synthetic (synthetic-peptides, non-peptide molecules and compounds, tetracyclines, metallic ions, and others) and natural bioactive inhibitors mainly flavonoids. Selective inhibitors of MMPs promise to be the future for specific targeting of preventing dentin proteolysis. The knowledge about MMPs functionality should be considered to synthesize drugs capable to efficiently and selectively block MMPs chemical routes targeting their inactivation in order to overcome the current limitations of the therapeutic use of MMPs inhibitors, i.e., easy clinical application and long-lasting effect.

Knockdown of lncRNA PVT1 Inhibits Vascular Smooth Muscle Cell Apoptosis and Extracellular Matrix Disruption in a Murine Abdominal Aortic Aneurysm Model

  • Zhang, Zhidong;Zou, Gangqiang;Chen, Xiaosan;Lu, Wei;Liu, Jianyang;Zhai, Shuiting;Qiao, Gang
    • Molecules and Cells
    • /
    • v.42 no.3
    • /
    • pp.218-227
    • /
    • 2019
  • This study was designed to determine the effects of the long non-coding RNA (lncRNA) plasmacytoma variant translocation 1 (PVT1) on vascular smooth muscle cell (VSMC) apoptosis and extracellular matrix (ECM) disruption in a murine abdominal aortic aneurysm (AAA) model. After injection of PVT1-silencing lentiviruses, AAA was induced in Apolipoprotein E-deficient ($ApoE^{-/-}$) male mice by angiotensin II (Ang II) infusion for four weeks. After Ang II infusion, mouse serum levels of pro-inflammatory cytokines were analysed, and aortic tissues were isolated for histological, RNA, and protein analysis. Our results also showed that PVT1 expression was significantly upregulated in abdominal aortic tissues from AAA patients compared with that in controls. Additionally, Ang II treatment significantly increased PVT1 expression, both in cultured mouse VSMCs and in AAA murine abdominal aortic tissues. Of note, the effects of Ang II in facilitating cell apoptosis, increasing matrix metalloproteinase (MMP)-2 and MMP-9, reducing tissue inhibitor of MMP (TIMP)-1, and promoting switching from the contractile to synthetic phenotype in cultured VSMCs were enhanced by overexpression of PVT1 but attenuated by knockdown of PVT1. Furthermore, knockdown of PVT1 reversed Ang II-induced AAA-associated alterations in mice, as evidenced by attenuation of aortic diameter dilation, marked adventitial thickening, loss of elastin in the aorta, enhanced aortic cell apoptosis, elevated MMP-2 and MMP-9, reduced TIMP-1, and increased pro-inflammatory cytokines. In conclusion, our findings demonstrate that knockdown of lncRNA PVT1 suppresses VSMC apoptosis, ECM disruption, and serum pro-inflammatory cytokines in a murine Ang II-induced AAA model.

A performance analysis of LDPC decoder for IEEE 802.16e WiMAX System (IEEE 802.16e WiMAX용 LDPC 복호기의 성능분석)

  • Kim, Eun-Suk;Kim, Hae-Ju;Shin, Kyung-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.722-725
    • /
    • 2010
  • In this paper, BER performance and error convergence speed of layered LDPC(Low Density Parity Check) decoder which supports IEEE 802.16e WiMAX standard is analyzed, and optimal design conditions for hardware implementation are derived. A LDPC decoder is modeled and simulated at AWGN channel with QPSK modulation by Matlab. The parity check matrix(PCM) for IEEE 802.16e standard which has block lengths of 576, 1440, 2304 and code rates of 1/2, 2/3A, 2/3B, 3/4A, 3/4B, 5/6 are used. Fixed-point simulation results show that fixed-point bit-width should be more than 8 bits for acceptable decoding performance.

  • PDF

Clinical Implication of Aortic Wall Biopsy in Aortic Valve Disease with Bicuspid Valve Pathology

  • Kim, Yong Han;Kim, Ji Seong;Choi, Jae-Woong;Chang, Hyoung Woo;Na, Kwon Joong;Kim, Jun Sung;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.49 no.6
    • /
    • pp.443-450
    • /
    • 2016
  • Background: Although unique aortic pathology related to bicuspid aortic valve (BAV) has been previously reported, clinical implications of BAV to aortopathy risk have yet to be investigated. We looked for potential differences in matrix protein expressions in the aortic wall in BAV patients. Methods: Aorta specimens were obtained from 31 patients: BAV group (n=27), tricuspid aortic valve (TAV) group (n=4). The BAV group was categorized into three subgroups: left coronary sinus-right coronary sinus (R+L group; n=13, 42%), right coronary sinus-non-coronary sinus (R+N group; n=8, 26%), and anteroposterior (AP group; n=6, 19%). We analyzed the expression of endothelial nitric oxide synthase (eNOS), matrix metalloproteinase (MMP)-9, and tissue inhibitor of matrix metalloproteinase (TIMP)-2. Results: Based on the mean value of the control group, BAV group showed decreased expression of eNOS in 72.7% of patients, increased MMP-9 in 82.3%, and decreased TIMP in 79.2%. There was a higher tendency for aortopathy in the BAV group: eNOS $(BAV:TAV)=53%{\pm}7%:57%{\pm}11%$, MMP-9 $(BAV:TAV)=48%{\pm}10%:38%{\pm}1%$. The AP group showed lower expression of eNOS than the fusion (R+L, R+N) group did; $48%{\pm}5%$ vs. $55%{\pm}7%$ (p=0.081). Conclusion: Not all patients with BAV had expression of aortopathy; however, for patients who had a suspicious form of bicuspid valve, aortic wall biopsy could be valuable to signify the presence of aortopathy.

An Improvement of the Extended Jones Matrix Expression for Analyzing Polarization Transmission Characteristics of a Uniaxial Medium (이방성 매질의 편광투과특성 분석을 위한 확장된 존스 행렬식의 개선)

  • Ryu, Jang-Wi;Shin, You-Sik;Kim, Sang-Youl;An, Sung-Hyuck;Kim, Yong-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.150-158
    • /
    • 2008
  • The exact transmission coefficients at the interface between a uniaxial anisotropic medium and an isotropic medium at? oblique incidence are derived by applying the extended Jones matrix method. When the birefringence of the uniaxial anisotropic medium is small ($|n_e-n_o|\;{\ll}\;n_o,\;n_e$), the exact transmission coefficients are compared with those by the conventional extended Jones matrix method by Yeh et al. They showed an excellent agreement with each other. In addition, using the exact transmission coefficients, we calculated the polarization characteristics of a light through a uniaxial medium to an incident light with arbitrary polarization state at? oblique incidence. We compared the transmittances of an unpolarized light through a pair of crossed o-type polarizers by two different methods and calculated the transmittance as the variation of the optical constants of the polarizers to evaluate of the extinction ratio. The polarization analysis method using the exact transmission coefficients can be applied to polarization characteristics of a light through a uniaxial medium with large birefringence as well as to liquid crystals and to optical anisotropic material.

Architecture Description Model for Common IT Resource Identification in e-Government Systems (공동활용자원식별을 위한 전자정부 시스템 아키텍처 서술 방안)

  • Shin, Soo-Jeong;Choi, Young-Jin;Jung, Suk-Chun;Seo, Yong-Won
    • The KIPS Transactions:PartD
    • /
    • v.16D no.4
    • /
    • pp.631-642
    • /
    • 2009
  • Although the Korean government is making great effort to prevent the redundancy in IT investment and efficiently allocate the IT budget, actual achievements are quite limited because of the variety of IT resources and different architecture description among organizations and projects. Thus, a standardized description model of the system architecture is strongly needed to identify the common resources and improve the efficiency of IT investment. Therefore, in this paper, we have developed the function-network matrix model which can be used as the basic template for a standard for architecture description of e-Government systems. The function-network matrix model integrates the function tiers and the network areas into a single unified framework, which enables the functionality of each component and the flow of information clearly visible. Moreover, we described the architectures of Korean e-government’s citizen service systems using our model, resulting in clear demonstration of the similarities and differences between different systems, and easy identification of the common resources. Using the architecture description model developed in this research, the consolidation of national IT resources can be promoted, and non-expert IT users can easily recognize the architecture of their systems. In addition, more efficient and systematic IT resource management can be achieved using our model.