Prognostic Value of Dynamic Contrast-Enhanced MRI-Derived Pharmacokinetic Variables in Glioblastoma Patients: Analysis of Contrast-Enhancing Lesions and Non-Enhancing T2 High-Signal Intensity Lesions

  • Yeonah Kang;Eun Kyoung Hong;Jung Hyo Rhim;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn;Sun-Won Park;Seung Hong Choi
    • Korean Journal of Radiology
    • /
    • 제21권6호
    • /
    • pp.707-716
    • /
    • 2020
  • Objective: To evaluate pharmacokinetic variables from contrast-enhancing lesions (CELs) and non-enhancing T2 high signal intensity lesions (NE-T2HSILs) on dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging for predicting progression-free survival (PFS) in glioblastoma (GBM) patients. Materials and Methods: Sixty-four GBM patients who had undergone preoperative DCE MR imaging and received standard treatment were retrospectively included. We analyzed the pharmacokinetic variables of the volume transfer constant (Ktrans) and volume fraction of extravascular extracellular space within the CEL and NE-T2HSIL of the entire tumor. Univariate and multivariate Cox regression analyses were performed using preoperative clinical characteristics, pharmacokinetic variables of DCE MR imaging, and postoperative molecular biomarkers to predict PFS. Results: The increased mean Ktrans of the CEL, increased 95th percentile Ktrans of the CELs, and absence of methylated O6-methylguanine-DNA methyltransferase promoter were relevant adverse variables for PFS in the univariate analysis (p = 0.041, p = 0.032, and p = 0.083, respectively). The Kaplan-Meier survival curves demonstrated that PFS was significantly shorter in patients with a mean Ktrans of the CEL > 0.068 and 95th percentile Ktrans of the CEL > 0.223 (log-rank p = 0.038 and p = 0.041, respectively). However, only mean Ktrans of the CEL was significantly associated with PFS (p = 0.024; hazard ratio, 553.08; 95% confidence interval, 2.27-134756.74) in the multivariate Cox proportional hazard analysis. None of the pharmacokinetic variables from NE-T2HSILs were significantly related to PFS. Conclusion: Among the pharmacokinetic variables extracted from CELs and NE-T2HSILs on preoperative DCE MR imaging, the mean Ktrans of CELs exhibits potential as a useful imaging predictor of PFS in GBM patients.

자기공명분석과 영상촬영을 위한 차폐된 고차경사자계코일의 설계 (Shielded High-Order Gradient Coil Design for Magnetic Resonance Spectroscopy and Imaging)

  • 오창현;;이윤;김민기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.45-48
    • /
    • 1993
  • High-order field gradients are useful for spatial localization of a volume of interest and dynamic range improvement of signal detection in NMR (Nuclear Magnetic Resonance) spectroscopy and imaging. This paper proposes a design method of shielded high-order gradient coils to reduce tile effect of eddy current on tile spectroscopy and imaging results. According to the experimental results, the shielded gradient coils produce less than 2 % eddy current compared to non-shielded coils. Two shielded $z^2$ gradient coils have been designed and constructed for 1.5 T whole-body and 3.0 T animal NMR imaging systems. Experimental results are in good agreement with the theoretically expected behavior and show the utility of the shielded high-order gradient coils.

  • PDF

Dynamic Susceptibility Contrast Magnetic Resonance Images를 이용한 뇌혈류량 지도 구성 (Cerebral Blood Volume Mapping from Dynamic Susceptibility Contrast Magnetic Resonance Images)

  • 김수정;이선규;김광기;김종효;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.281-282
    • /
    • 1998
  • Recently, there has been growing interest in the assessment of physiological parameters on brain perfusion that provide more information than pure morphologic diagnosis. Quantification of parameters that characterize cerebral micro-circulation with magnetic resonance imaging is of great relevance for clinical application. We determine the local tissue concentration by exponential relationship between the relative signal reduction S(t)/$S_0$ and local tissue concentration of contrast material $C_m(t)$ in dynamic susceptibility contrast enhanced MR imaging. And then we made relative regional blood volume map by calculating the area under the measured concentration-time curves $C_m(t)$ during first pass of paramagnetic contrast material as a preliminary step for perfusion map. These images make it possible to compare the rCBV in different brain regions in one individual at a time. We have it in contemplation to obtain arterial and brain signal time curves simultaneously to make absolute rCBV and perfusion (rCBF) map. These maps may provide the method of comparative investigations of different patients having strong variation in AIF.

  • PDF

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교 (Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom)

  • 김성은;원희수;홍주완;장남준;정우현;최병돈
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.123-130
    • /
    • 2016
  • 목 적 : Computerized imaging reference systems 동적팬텀을이용한 cone-beamcomputed tomography(CBCT) 영상과 four-dimensionalcomputed tomography(4DCT) 영상의 체적을 비교분석 하고자 한다. 대상 및 방법 : 동적팬텀 내에 직경 1, 2, 3 cm 노드를 각각 삽입하고, CT simulator와 TruebeamSTx X-ray Imaging system을 이용하여 4DCT 영상과 CBCT 영상을 얻었다. 4DCT 영상은 maximum intensity projection(MIP), minimum intensity projection(MinIP), 그리고 average intensity projection(AVG)영상으로 재구성 하고 노드의 체적은 Eclipse system의 CT ranger tool로 CT number를 설정하여 측정하였다. 결 과 : CBCT를 기준으로 노드1, 2, 3 cm의 체적을 비교하였을 때 4DCT의 MIP는 0.54~2.33, 5.16~8.06, 9.03~20.11 ml, MinIP는 0.00~1.48, 0.00~8.47, 1.42~24.85 ml, AVG는 0.00~1.17, 0.00~2.19, 0.04~3.35 ml의 차이를 보였다. 결 론 : 노드의 체적을 비교한 결과 CBCT 영상은 4DCT의 AVG 영상과 유사한 것으로 확인되었다.

  • PDF

적응 템플릿 필터링에서 복셀의 부분 볼륨 효과로 인한 헤지 아티팩트의 제거 (Removal of Edge Artifact due to Pertial Volume Effect in the Adaptive Template Filtering)

  • 안창범;송영철
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권2호
    • /
    • pp.120-127
    • /
    • 2000
  • 최근에 해상도의 손실없이 신호대잡음비를 개선시킬 수 있는 적응 템플릿 필터링이 제안되었다. 적응 템플릿 필터링은 다중 템플릿들 중에서 현재 복셀의 주변 구조와 가장 잘 매칭이 되는 템플릿을 선택하여 적응필터 링을 적용하는 방법이다. 적응 템플릿 필터링을 자기공명영상에 적용할때 기존의 필터링 방법들에 비하여 향상된 결과를 얻을 수 있으나, $T_1$ 영상과 같이 비교적 작은 동적 범위를 가진 영상에서는 에지에서 계단모양의 artifact가 발견되곤 한다. 이것은 자기 공명영상에서 복셀의 부분적인 볼륨 효과에 기인하는 것으로 여러 조직의 성분을 포함하고 있는 경계면의 복셀들에 적응 템플릿 필터링이 적용될 경우 다중성분을 가진 복셀들의 그레이레벨이 인접한 단일성분의 그레이레벨 값에 가까워져 에지가 강조되기 때문이다 본 논문에서는 다중 성분을 갖는 복셀들을 선별하여 이들에 대해서는 가장 큰 크기의 템플릿을 할당함으로써 artifact를 제거하는 방법을 제안하였다. 제안한 방법을 $T_1$ 자기공명영상과 팬텀 영상에 적용한 결과 에지 artifact가 사라지는 것을 확인할 수 있었으며, 최대 신호대잡음비 면에서도 향상된 결과를 얻을 수 있었다.

  • PDF

Leak Sign on Dynamic-Susceptibility-Contrast Magnetic Resonance Imaging in Acute Intracerebral Hemorrhage

  • Park, Ji Kang;Hong, Dae Young;Jin, Sun Tak;Lee, Dong-Woo;Pyun, Hae Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.154-161
    • /
    • 2020
  • Purpose: A CT angiography spot sign (CTA-spot) is a significant predictor of the early expansion of an intracerebral hemorrhage (ICH-Ex). Dynamic-susceptibility-contrast magnetic resonance imaging (DSC-MRI) can track the real-time leaking of contrast agents. It may be able to indicate active bleeding, like a CTA-spot. Materials and Methods: From September 2014 to February 2017, we did non-contrast CT, CTA, and DSC-MRI examinations of seven patients with acute ICH. We investigated the time from symptom onset to the first contrast-enhanced imaging. We evaluated the time course of the contrast leak within the ICH at the source image of the DSC-MRI and the volume change of ICH between non-contrast CT and DSC-MRI. We compared the number of slices showing CTA-spots and DSC-MRI leaks. Results: The CTA-spot and DSC-MRI leak-sign were present in four patients, and two patients among those showed ICH-Ex. The time from the symptom onset to CTA or DSC-MRI was shorter for those with a DSC-MRI leak or CTA-spot than for three patients without either (70-130 minutes vs. 135-270 minutes). The leak-sign began earlier, lasted longer, and spread to more slices in the patients with ICH-Ex than in those without ICH-Ex. The number of slices of the DSC-MRI leak and the number of the CTA-spot were well correlated. Conclusion: DSC-MRI can demonstrate the leakage of GBCA within hyperacute ICH, showing the good contrast between hematoma and contrast. The DSC-MRI leakage sign could be related to the hematoma expansion in patients with ICH.

나비 펌프의 구조와 동적 거동의 in vivo 가시화 (In vivo visualization of liquid-feeding phenomena of a butterfly)

  • 이승철;김보흠;이상준
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.69-73
    • /
    • 2011
  • Butterflies have been known to suck viscous liquids through a long, cylindrical proboscis using the large pressure difference formulated by the cyclic expansion and contraction of a muscular pump located inside their head. However, there are few studies on the liquid-feeding phenomena in a live butterfly, because it is hard to observe the internal morphological structures under in vivo condition. In this study, the dynamic motion of the pump system in a butterfly was in vivo visualized using synchrotron X-ray micro-imaging technique to analyze the liquid-feeding mechanism. The period of the liquid-feeding process is about 0.3sec. The expansion stage is about two times larger than the contraction stage in one cycle. The cyclic variation of pump volume generate large negative suction pressure and the pressure difference inside the long proboscis of a butterfly is estimated to be larger than 1atm.

Basic Performance Evaluation of the First Model of 4-Dimensional CT-Scanner

  • Mori, Shinichiro;Endo, Masahiro;Tsunoo, Takanori;Kandatsu, Susumu;Tanada, Shuzi;Aradate, Hiroshi;Saito, Yasuo;Miyazaki, Hiroaki;Satoh, Kazumasa;Matsusita, Satoshi;Kusakabe, Masahiro
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.376-378
    • /
    • 2002
  • This work was carried out to evaluate the basic performances for 4D CT, which employed continuously rotating conebeam. The performances were evaluated with the same method as the conventional CT, because the standard method of evaluating 4D CT has not yet been established, and we think this result was helpful to establish it. 4D CT can give dynamic volume imaging data continuously and with high-speed. The results were isotropic except for the evaluation of distortion in which small distortions gradually appeared as coming off the center of phantom in longitudinal direction.

  • PDF

합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : I. 구형파 송신 방법 (Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: I. Spherical Wave Transmission Approach)

  • 김강식;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권5호
    • /
    • pp.391-401
    • /
    • 2004
  • 이차원 위상 어레이 변환자를 이용하는 실시간 3차원 영상 시스템은 많은 수의 채널 수를 가지기 때문에 고 비용의 매우 복잡한 빔집속부를 사용하여야 한다. 또한 각 주사선에 대해 초음파를 매번 송수신해야 하므로 볼륨 레이트 또한 낮게 된다. 이를 해결하기 위해 기존에 제안된 교차어레이를 이용한 3차원 영상화 기법은 실시간 3차원 영상을 위한 고속 주사가 가능하고 측방향으로는 동적집속이 가능하지만, 고도방향으로는 송신집속깊이를 제외하고는 고도방향의 해상도가 저하된다는 문제점이 있다. 이러한 문제점을 극복하기 위해 본 논문에서는 합성구경 기반의 교차 어레이를 사용한 3차원 영상화 기법을 제안한다. 제안한 방법에서는 고도방향으로 놓인 일차원 송신어레이의 각 변환소자를 한번에 하나씩 순차적으로 송신하고, 반사된 신호들을 측방향으로 놓인 일차원 수신어레이의 모든 변환소자를 이용하여 수신하게 된다. 수신시 측방향으로는 동적집속, 고도방향으로는 합성구경 기법을 이용하여 빔을 집속함으로써 모든 영상 점에 대해 측방향과 고도방향 모두 동적집속된 효과를 얻을 수 있다. 또한, 제안한 방법은 고도방향으로 합성구경 기법을 이용함으로써 송신어레이 변화소자 개수만큼의 초음파 송수신 과정을 통해 관심 영역의 입제영상을 임의의 요구되는 단면영상 수를 이용하여 구성할 수 있다. 제안한 방법을 통해 기존의 고정집속 기반의 교차어레이를 이용한 3차원 영상화 기법과 비교하여 측방향으로는 동일하고 고도방향으로는 훨씬 우수한 해상도의 영상을 획득할 수 있음을 컴퓨터 모사실험을 통해 점증하였다. 또한 동반논문에서는 제안한 방법에 비해 송신전력과 고도방향 해상도를 더욱 향상시킬 수 있는 선형파면 기반의 합성구경 기법을 제안한다.