• Title/Summary/Keyword: dynamic tests

Search Result 2,298, Processing Time 0.029 seconds

Assessment of End Condition of Drilled Shafts Socketed into Rock by Impact Echo Test (충격반향기법을 이용한 암반근입 현장타설말뚝의 선단조건 평가)

  • 김형우;김동수;김원철
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.21-32
    • /
    • 2002
  • Small and full scale model tests were performed to obtain the transient responses of shafts subjected to elastic impact by impact-echo test. Four end conditions of drilled shafts were considered: (1) free, (2) fixed, (3) rock-socketed, and (4) soft bottom. In small scale model tests, mock-up shafts were fabricated to simulate these four drilled shafts using poly-urethane and plastic material. Additionally, skin frictions between shaft and rock were changed to find out the effect of side contact on dynamic responses. All impact responses were tested in the air. Subsequently, full scale model tests were also carried out on concrete shafts that were in free and rock-socketed condition. The end conditions of the drilled shafts could be identified with good reliability by the waveforms from both small and full scale model tests. The results obtained in this study will provide an improved understanding of the impact responses for end conditions, especially for rock-socketed drilled shafts that are frequently designed and built in Korea.

Aircraft Load Monitoring System Development & Application to Ground Tests Using Optical Fiber Sensors (광섬유 센서를 사용한 항공기용 하중 모니터링 시스템 개발과 지상시험 적용)

  • Park, Chan Yik;Ha, Jae Seok;Kim, Sang Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.8
    • /
    • pp.639-646
    • /
    • 2017
  • In this paper, a new load monitoring system for military aircraft is introduced. This system consists of sensors, an onboard device and an ground analysis equipment. The sensors and onboard device are mounted on the aircraft and the ground analysis equipment is operated on the ground. Through this system, structural static load can be estimated with flight parameters and structural responses can be measured by sensors due to static load, dynamic load and unexpected events. Especially, optical fiber sensors with mutiplexing capability are utilized. The onboard device was specially designed for complying the requirements of relevant military specifications and was verified through a series of the environment tests. This system was used and evaluated through ground structural tests before flight tests. In the near future, this system will be applied to military aircraft as a structural load monitoring system after flight test evaluation.

The Effect of Bearing Capacity Increasement for Driven Pile in Silt (실트지반에 타입된 말뚝의 지지력 증가효과)

  • Yeo, Byung Chul;Oh, Se Wook;Bae, Woo Seok;Ahn, Byung Chul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.3
    • /
    • pp.19-26
    • /
    • 2003
  • Recently, for the design of pile foundations on the soft ground condition, it is recognized that set-up effects are another important factor which influence the characteristics of bearing capacity of pile. In this paper, the thirteen dynamic pile loading tests were performed at the two different construction sites and the end of initial driving(EOID) were also performed and then restrike tests were performed after certain time lag. The H-pile, pipe pile, PHC pile are installed by driving into the loose silty soil and then restrike tests were performed. Nine days after pile driving, the bearing capacity of H and pipe pile were increased whereas there is not bearing capacity increasement with PHC pile. When the dense silty soil, the restrike test results showed that the bearing capacity of H and pipe pile increased up to 1.17 times. The 1-st and 2-nd restrike tests performed after 6 and 12 day, respectively. The results showed that the bearing capacity of PHC pile was decreased but the bearing capacity of piles were increased up to 1.38 times after 13 days with the third restrike test.

  • PDF

Development of the similitude law considering the intensity-dependent variation of natural frequency of pile foundation system (말뚝 기초 고유진동수의 가속도 크기 의존성을 고려한 상사법칙 개발)

  • Choi, Jung-In;Yoo, Min-Teak;Kim, Sung-Yul;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.905-912
    • /
    • 2009
  • 1-g shaking table test is conducted to evaluate the dynamic behavior of a soil-structure system under seismic loading condition. A consistent similitude law between the model and prototype is needed to predict the behavior of the prototype structure, quantitatively. The natural frequency of geomaterial decreases with the increase of shaking intensity because of the non-linear property of the geomaterial. This phenomenon affects the applicability of similitude laws in 1-g shaking table tests. In this study, a simple method is suggested to determine the frequency of the input motions in 1-g tests in order to enhance the applicability of similitude laws. Modified input frequency is calculated using the frequency ratio with consideration of the variation of the natural frequency according to the intensity of input ground acceleration. To verify the applicability of the suggested method, a series of 1-g shaking table tests were performed for three different sizes of model piles having an overburden mass on their heads by varying the acceleration and the frequency of input motion. The acceleration amplification ratio on the overburden mass, the lateral displacement at the pile head and the maximum bending moment along the pile depth were measured. The projected behaviors of the virtual prototype based on the measured values of the model tests, where the input frequencies were calculated by the new method, showed good consistency, verifying the applicability of the suggested method.

  • PDF

A Numerical Investigation for Prediction of Shock Deceleration of Conical Impactor in Gas-Gun Tests (가스건 시험에서 원추형 충격자의 충격 감가속도 예측에 관한 전산해석적 연구)

  • Yoon, Hee;Oh, Jong Soo;Jung, Myung-Suk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.5
    • /
    • pp.279-286
    • /
    • 2019
  • In this study, a numerical investigation is conducted for the shock deceleration prediction of a conical impactor in gas-gun tests. With the development of weapon systems, gas-gun tests are required to validate the survivability and structural reliability of devices under test (DUT) in high-G shock environments, such as those over ten thousand Gs or more. As shock endurance is highly influenced by various bird parameters, such as mass, velocity, and pressure, it is important to determine the appropriate test conditions to generate a high-G shock environment. However, experimental repetitive studies are inefficient to validate test conditions in terms of economic aspects. Therefore, a numerical technique is required to replace experimental gas-gun tests. Here, a numerical investigation is conducted with ANSYS AUTODYN using explicit code. Through this investigation, the dynamic behavior of DUT is presented. In addition, the results of numerical studies are verified through a comparison with the experimental results of a gas-gun test.

Experimental evaluation of crack effects on the dynamic characteristics of a prototype arch dam using ambient vibration tests

  • Sevim, Baris;Altunisik, Ahmet Can;Bayraktar, Alemdar
    • Computers and Concrete
    • /
    • v.10 no.3
    • /
    • pp.277-294
    • /
    • 2012
  • The aim of the study is to determine the modal parameters of a prototype damaged arch dam by operational modal analysis (OMA) method for some damage scenarios. For this purpose, a prototype arch dam-reservoir-foundation model is constructed under laboratory conditions. Ambient vibration tests on the arch dam model are performed to identify the modal parameters such as natural frequency, mode shape and damping ratio. The tests are conducted for four test-case scenarios: an undamaged dam with empty reservoir, two different damaged dams with empty reservoirs, and a damaged dam with full reservoir. Loading simulating random impact effects is applied on the dam to crack. Cracks and fractures occurred at the middle of the upper part of the dams and distributed through the abutments. Sensitivity accelerometers are placed on the dams' crests to collect signals for measurements. Operational modal analysis software processes the signals collected from the ambient vibration tests, and enhanced frequency domain decomposition and stochastic subspace identification techniques are used to estimate modal parameters of the dams. The modal parameters are obtained to establish a basis for comparison of the results of two techniques for each damage case. Results show that approximately 35-40% difference exists between the natural frequencies obtained from Case 1 and Case 4. The natural frequencies of the dam considerably decrease with increasing cracks. However, observation shows that the filled reservoir slightly affected modal parameters of the dam after severe cracking. The mode shapes obtained are symmetrical and anti-symmetrical. Apparently, mode shapes in Case 1 represent the probable responses of arch dams more accurately. Also, damping ratio show an increase when cracking increases.

Experimental study on models of cylindrical steel tanks under mining tremors and moderate earthquakes

  • Burkacki, Daniel;Jankowski, Robert
    • Earthquakes and Structures
    • /
    • v.17 no.2
    • /
    • pp.175-189
    • /
    • 2019
  • The aim of the study is to show the results of complex shaking table experimental investigation focused on the response of two models of cylindrical steel tanks under mining tremors and moderate earthquakes, including the aspects of diagnosis of structural damage. Firstly, the impact and the sweep-sine tests have been carried out, so as to determine the dynamic properties of models filled with different levels of liquid. Then, the models have been subjected to seismic and paraseismic excitations. Finally, one fully filled structure has been tested after introducing two different types of damages, so as to verify the method of damage diagnosis. The results of the impact and the sweep-sine tests show that filling the models with liquid leads to substantial reduction in natural frequencies, due to gradually increasing overall mass. Moreover, the results of sweep-sine tests clearly indicate that the increase in the liquid level results in significant increase in the damping structural ratio, which is the effect of damping properties of liquid due to its sloshing. The results of seismic and paraseismic tests indicate that filling the tank with liquid leads initially to considerable reduction in values of acceleration (damping effect of liquid sloshing); however, beyond a certain level of water filling, this regularity is inverted and acceleration values increase (effect of increasing total mass of the structure). Moreover, comparison of the responses under mining tremors and moderate earthquakes indicate that the power amplification factor of the mining tremors may be larger than the seismic power amplification factor. Finally, the results of damage diagnosis of fully filled steel tank model indicate that the forms of the Fourier spectra, together with the frequency and power spectral density values, can be directly related to the specific type of structural damage. They show a decrease in the natural frequencies for the model with unscrewed support bolts (global type of damage), while cutting the welds (local type of damage) has resulted in significant increase in values of the power spectral density for higher vibration modes.

Intra- and Inter-rater Reliability of BioRescue (BioRescue의 측정자내와 측정자간 신뢰도)

  • Kim, Jin-hong;Choi, Bo-ram
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.348-352
    • /
    • 2018
  • BioRescue ($RMIng{\acute{e}}nierie$, Marseille, France) is able to assess dynamic and static balance when a test subject stands or sits over the platform. Although previous studies have examined the reliability of other balance measurement methods, little research has been conducted on the reliability of equipment such as BioRescue. This study examined the intra-rater and inter-rater reliability of BioRescue during balance assessment. Thirty-four healthy adults participated as subjects and two physical therapists participated as examiners to determine intra- and inter-rater reliability. BioRescue was used to conduct measurements during footprint (area and pressure), Romberg, and limit of stability tests. The footprint area and limit of stability tests yielded intra- and inter-rater reliability ICC values above 0.60 in all directions. However, the footprint pressure and Romberg tests yielded values below 0.60 in all directions. BioRescue showed good inter-rater and intra-rater reliability in measurements during footprint area and limit of stability tests. However, because the values of limits of stability show the difference between experienced and unskilled, skill is required for the accuracy of the equipment.

Multiscale Wavelet-Galerkin Method in General Two-Dimensional Problems (일반 형상의 2차원 영역에서의 멀티스케일 웨이블렛-갤러킨 기법)

  • Kim, Yun-Yeong;Jang, Gang-Won;Kim, Jae-Eun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.939-951
    • /
    • 2002
  • We propose a new multiscale Galerkin method based on interpolation wavelets for two-dimensional Poisson's and plane elasticity problems. The major contributions of the present work are: 1) full multiresolution numerical analysis is carried out, 2) general boundaries are handled by a fictitious domain method without using a penalty term or the Lagrange multiplier, 3) no special integration rule is necessary unlike in the (bi-)orthogonal wavelet-based methods, and 4) an efficient adaptive scheme is easy to incorporate. Several benchmark-type problems are considered to show the effectiveness and the potentials of the present approach. is 1-2m/s and impact deformation of the electrode depends on the strain rate at that velocity, the dynamic behavior of the sinter-forged Cu-Cr is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain rate is obtained from the split Hopkinson pressure bar test using disc-type specimens. Experimental results from both quasi-static and dynamic compressive tests are Interpolated to construct the Johnson-Cook model as the constitutive relation that should be applied to simulation of the dynamic behavior of the electrodes. The impact characteristics of a vacuum interrupter are investigated with computer simulations by changing the value of five parameters such as the initial velocity of a movable electrode, the added mass of a movable electrode, the wipe spring constant, initial offset of a wipe spring and the virtual fixed spring constant.

The Effects of Core Stability Exercise on the Ability of Postural Control in Patients With Hemiplegia

  • Kim, Young-Dong;Hwang, Byoung-Yong
    • Physical Therapy Korea
    • /
    • v.16 no.4
    • /
    • pp.23-30
    • /
    • 2009
  • Core stability exercises for patients with hemiplegia have become increasingly important and a variety of exercises have been developed over the years to give the hemiplegic patients more stable postural control. This study examined the therapeutic effects of the core stability exercises on the ability of static and dynamic postural control. Fifteen hemiplegic patients (7 males, 8 females, age ranging from 46 to 76 years) hospitalized in a Daejoen rehabilitation hospital were enrolled in this study. Nine and 6 patients had a cerebral infarction and cerebral hemorrhage, respectively. The subjects participated in a core stability exercise program consisting of a total of 12 sessions 3 times each week over a 4-week period with each exercise lasting approximately 15 minutes. The ability of static and dynamic postural control by Berg Balance Scale (BBS) and Timed Up and Go (TUG), respectively, were measured before and after the core stability exercise. A Wilcoxon signed ranks test was used to compare the effects of the ability of static and dynamic postural control before and after core stability exercise in patients with hemiplegia. The ${\alpha}$=.05 level of significance was used for the statistical tests. Core stability exercises were effective in improving the ability of static postural control; BBS (p<.05). Core stability exercises were also effective in improving the ability of dynamic postural control; TUG (p<.05). Overall, core stability exercise is believed to be an important therapeutic method in rehabilitation programs for hemiplegic patients.

  • PDF