• Title/Summary/Keyword: dynamic measurement

Search Result 1,893, Processing Time 0.029 seconds

Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction

  • Zhang, Ye;Zheng, Yang
    • Current Optics and Photonics
    • /
    • v.4 no.6
    • /
    • pp.500-508
    • /
    • 2020
  • The rifling angle of artillery is an important parameter, and its determination plays a key role in the stability, hit rate, accuracy and service life of artillery. In this study, we propose an optical measurement method for the rifling angle based on angle error correction. The method is based on the principle of geometrical optics imaging, where the rifling on the inner wall of the artillery barrel is imaged on a CCD camera target surface by an optical system. When the measurement system moves in the barrel, the rifling image rotates accordingly. According to the relationship between the rotation angle of the rifling image and the travel distance of the measurement system, different types of rifling equations are established. Solving equations of the rifling angle are deduced according to the definition of the rifling angle. Furthermore, we added an angle error correction function to the method that is based on the theory of dynamic optics. This function can measure and correct the angle error caused by the posture change of the measurement system. Thus, the rifling angle measurement accuracy is effectively improved. Finally, we simulated and analyzed the influence of parameter changes of the measurement system on rifling angle measurement accuracy. The simulation results show that the rifling angle measurement method has high measurement accuracy, and the method can be applied to different types of rifling angle measurements. The method provides the theoretical basis for the development of a high-precision rifling measurement system in the future.

Application of Vision-based Measurement System for Estimation of Dynamic Characteristics on Hanger Cables (행어케이블의 동특성 추정을 위한 영상계측시스템 적용)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1A
    • /
    • pp.1-10
    • /
    • 2012
  • Along with the development of coasts, islands and mountains, the demand of long-span bridges increases which, in turn, brings forth the construction of cable-supported bridges like suspension and cable-stayed bridges. There are various types of statically indeterminate structures widely applied that supported the main girder with stay cables, main cables, hanger cables with aesthetic structural appearance. As to the cable-supported bridges, the health monitoring of a bridge can be identified by measuring tension force on cable repeatedly. The tension force on cable is measured either by direct measurement of stress of cable using load cell or hydraulic jack, or by vibration method estimating tension force using cable shape and measured dynamic characteristics. In this study, a method to estimate dynamic characteristics of hanger cables by using a digital image processing is suggested. Digital images are acquired by a portable digital camcorder, which is the sensor to remotely measure dynamic responses considering convenient and economical aspects for use. A digital image correlation(DIC) technique is applied for digital image processing, and an image transform function(ITF) to correct the geometric distortion induced from the deformed images is used to estimate subpixel. And, the correction of motion of vision-based measurement system using a fixed object in an image without installing additional sensor can be enhanced the resolution of dynamic responses and modal frequencies of hanger cables.

An Operating Frequency Independent Energy Measurement Technique for High Speed Microprocessors

  • Thongnoo, Krerkchai;Changtong, Kusumal
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.2051-2054
    • /
    • 2004
  • This paper proposes a more accurate task level energy measurement technique for high speed microprocessors. The technique is based on the relationship of the amount of current consumed by the microprocessor and the pulse width of the power supply controller chip, employed in the synchronous buck DC-DC converter in the microprocessor's power supply. The accuracy of the measurement is accomplished by measuring variation in pulse width in each power supply cycle. The major advantage of this technique is that its accuracy does not depend on the operating frequency of the microprocessor. To prove the proposed technique, we implemented the measurement unit of the microprocessor energy meter using an FPGA chip operating at 50 MHz. Both static and dynamic load measurement are tested in order to obtain some behaviours. Moreover, various commercially available mainboards which employ synchronous buck regulators at 200 KHz switching frequency, were measured. The results agree with previous works with better accuracy at higher operating frequency.

  • PDF

Design of Measurement System and Thrust Force Analysis Method for HB-Type Linear Pulse Motor (HB형 선형 펄스모터의 추력 계산법의 비교 및 측정장치 설계)

  • Bae D.K.;Kim K.H.;Park H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.141-145
    • /
    • 2003
  • The linear motor available for linear transition motion, because of its advantages, the motor design and its application have gradually increased, but the quantitative measurement system of thrust force has not been generalized. So, this paper proposes the modeling, computation method, and measurement system of linear thrust force in HB-type linear pulse motor. As the computation method of thrust force in linear motor is presented and the measurement system is designed, and manufactured, it would be verified that reliability of measurement method and measurement system, considering on and comparing the results of mathematical modeling with measured values of static thrust force and dynamic one.

  • PDF

Non-invasive Methods for Determination of Cellular Growth in Podophyllum hexandrum Suspension Cultures

  • Chattopadhyay, Saurabh;Bisaria, V.S.;Scheper, T.;Srivastava, A.K.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.6
    • /
    • pp.331-334
    • /
    • 2002
  • Culture conductivity and on-line NADH fluorescence were used to measure cellular growth in plant cell suspension cultures of Podophyllum hexandrum. An inverse correlation between dry cell weight and medium conductivity was observed during shake flask cultivation. A linear relationship between dry cell weight and culture NADH fluorescence was obtained during the exponential phase of batch cultivation In a bioreactor under the pH stat (pH 6) conditions. It was observed that conductivity measurement were suitable for biomass characterisation under highly dynamic uncontrolled shake flask cultivation conditions. However, if the acid/alkali feeding is done for pH control the conductivity measurement could not be applied. On the other hand the NADH fluorescence measurement allowed online-in situ biomass monitoring of rather heterogenous plant cell suspension cultures in bioreactor even under the most desirable pH stat conditions.

Simultaneous Temperature and Velocity Fields Measurements near the Boiling Point

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Koo, Bon-Young;Kim, Seok-Ro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.531-542
    • /
    • 2007
  • Simultaneous measurement technique for temperature and velocity fields near a heated solid body has been constructed. The measurement system consists of a 3-late CCD color camera, a color image grabber, a 1ighting system, a host computer and a software for the whole quantification process. Thermo Chromic Liquid Crystals (TCLC) was used as temperature sensors. A neural network was used to get a calibration curve between the temperature and the color change of the TCLC in order to enhance the dynamic range of temperature measurement. The velocity field measurement was attained by the use of the fray-level images taken for the flow field, and by introducing the cross-correlation technique. The temperature and the velocity fields of the forced and the natural convective flows neat the surface of a cartridge heater were measured simultaneously with the constructed measurement system.

A Experimental Study on Application of KS F 2456 using Shear Wave (급속 동결 융해에 대한 콘크리트의 저항 시험방법(KS F 2456)에 전단파 적용을 위한 실험적 연구)

  • An, Ji-Hwan;Jeon, Sung-Il;Kwon, Soo-Ahn
    • International Journal of Highway Engineering
    • /
    • v.14 no.5
    • /
    • pp.57-65
    • /
    • 2012
  • PURPOSES: It is important to consider the long-term performance of concrete pavement, because concrete pavement is more exposed to the various environmental conditions than any other concrete structures. One of the several methods to evaluate the long-term performance of concrete during winter is KS F 2456. Relative dynamic modulus of elasticity shows the resistance to freezing and thawing. METHODS: To measure relative dynamic modulus of elasticity, ultra sonic is generally used. But in this study, to measure the relative dynamic modulus of elasticity, both ultra sonic and shear wave were used and then compared each other. RESULTS: The results from the measurement by ultrasonic wave and shear wave were divided into three types. Type 1 : Specimens are good and relative dynamic modulus of elasticity did not decrease until 300 cycle. Type 2 : The relative dynamic modulus of elasticity decreased from the late cycle.(about 150 cycle later) Type 3 : The relative dynamic modulus of elasticity consistently decreased from the beginning. As a result of ANOVA, there is no difference according to measuring method, in type 2 and 3. But there is a difference according to measuring method, in type 1's relative dynamic modulus of elasticity. CONCLUSIONS: It is proved that shear wave can be used to understand the damage tendency of relative freezing and thawing and to measure the relative dynamic modulus of elasticity.

An Experimental Study for the Development of Epoxy Adhesives for Optical Top (광학정반용 에폭시 접착제 개발을 위한 실험적 연구)

  • Gil, Hyeong-Gyeun;Youn, Seok-Weon;Kim, Kwang-San
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.8
    • /
    • pp.727-733
    • /
    • 2010
  • Optical tables provide a platform for the establishment and test of measurement systems which use Laser. Therefore, not only static characteristics such as surface flatness, static stiffness and etc. but dynamic response characteristics is very important design parameter. The dynamic stiffness is generally estimated through the modal test, and compliance is used as a representative performance standard. Recently there is an example of defining the dynamic deflection coefficient and using it as a new performance standard of the dynamic stiffness, but it is not generalized yet in industry. In this study, we verify the validity of existing DDC calculus by making an experiment on granite. And for improvement in damping performance of optical tables, we are going to evaluate the effect of fillers on the compliance, then develop an epoxy adhesive based on the result of this experiment.

A Measurement Study of a Dynamic Insulator Thermal Performance (동적 단열재의 열성능 측정에 관한 연구)

  • Ko, Seon-Mi;Kang, Eun-Chul;Lee, Euy-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.361-368
    • /
    • 2010
  • Due to the insulation and the air-tightness requirement in modern buildings have resulted NBS(New Building Syndrome) and SBS(Sick Building Syndrome) of IAQ problems. Therefore, energy efficient way of solving such IAQ issues are of major concern in these days and building industries. This paper introduces a method to improve thermal performance with a DI(Dynamic Insulation) concept. The characteristic of the dynamic insulation is that the lower U-value as the higher air velocity through the DI in a micro level. A thermal performance monitoring study has been conducted to show the energy impact of porous DI over the static insulation material. The results show that up to 45% could be improved in the case with DI compared to the conventional insulation.

A Study on the Characteristics of Internal Dynamic Pressure of Vane Pump (베인 펌프의 내부 비정상 압력특성에 관한 연구)

  • 정석훈;정재연
    • Tribology and Lubricants
    • /
    • v.14 no.1
    • /
    • pp.79-84
    • /
    • 1998
  • This paper presents the experimental study of the dynamic internal pressure within a vane pump. The measurement of the dynamic internal pressure acting on the line contact between the vane and the camring in a vane pump with intravanes have been investigated. The variations of the radial acting force of a vane are calculated from previously measured results of dynamic internal pressure in four chambers surrounding a vane, and the variations of the film thickness are estimated in both the rotational speed ranges from 600 to 1200 rpm and the delivery pressure ranges from 1 to 14 MPa. The experimental technic has been established to obtain the data for performance analysis, such as reaction forces between vane and camring, friction wear at the contact regions, leakage characteristics and net forces upon the pump shaft in case of the unsteady load which is forced to the intravane pressure balance type vane pump.