• Title/Summary/Keyword: dynamic interval

Search Result 335, Processing Time 0.019 seconds

Effects of Leisure Time-Use and Occupational Performance according to the Participation of a Rehabilitation Sports Program for Intellectual Disabilities Residing in a Residential Care Facility (시설 거주 지적장애인들의 재활체육 프로그램 참여에 따른 여가시간 사용과 여가활동 수행에 미치는 영향)

  • Son, Sung-Min;Lee, Kyeong-Lark;Jeon, Byoung-Jin
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.6 no.2
    • /
    • pp.51-59
    • /
    • 2016
  • Objective : The purpose of study is to provide basic information about the effects of leisure time use and leisure activity performance for intellectual disabilities residing in a residential care facility by participating a regular rehabilitation sports program. Methods : Participants were recruited 8 individual with intellectual disability in a residential care facility in Yong-in city and the study period lasted 12 weeks, from september 1 to November 30 in 2015. As a program, participants participated a muscle strengthening exercise using a Gym-ball and a elastic band. In order to analyze leisure time-use, time questionnaire was used every month to analyze total time and exercise frequency. Also, analyze the effects of leisure activity performance, Canadian Occupational Performance Measure(COPM) was used to performance and satisfaction of dynamic leisure activity. Collected data was encoded by item and analyzed with SPSS ver18.0. Descriptive statistics were used for the participants' general information. A non-parametric test (the Friedman test) was used to analyze leisure time-use. A non-parametric test (the Wilcoxon's signed ranked test) was used to analyze to the effects of leisure activity performance. Statistical significance was accepted outside the 95% confidence interval. Results : The results of the total time and the exercise frequency showed significant increase. Also, the results of the performance and the satisfaction showed significant increase. Conclusion : Thus, the participation of the rehabilitation sports program is a vital element to lead to change leisure time use and leisure activity performance for intellectual disabilities residing in a residential care facility. Also, through the providing and the developing a regular rehabilitation sports program systematically, intellectual disabilities residing in a residential care facility have a higher quality of life and satisfaction of the daily routine and life in a residential care facility.

The Impact of monsoon Rainfall (Changma) on the Changes of Water Quality in the Lower Nakdong River (Mulgeum) (장마기의 강우가 낙동강 하류 (물금) 수질에 미치는 영향)

  • Park, Sung-Bae;Lee, Sang-Kyun;Chang, Kwang-Hyeon;Jeong, Kwang-Suek;Joo, Gea-Jae
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.3 s.99
    • /
    • pp.160-171
    • /
    • 2002
  • The impact of summer monsoon on water quality of the lower Nakdong River was evaluated during the summer (June-August) in 1997. Several limnological variables were measured in the interval of $1{\sim}3$ day using an automatic monitoring system (Hydrolab $Recorder^{TM}$) to detect water quality changes caused by rainfall on onehour basis. During the monsoon period (from late June to mid July), 5 times of major rainfall events of >50 mm were recorded in the river basin. Dynamic changes of water quality were observed during the monsoon, and the first rainfall event (June$25{\sim}27$) had a significant influence on the water quality at the lower part of the river. All Parameters were largely changed due to the first rain event, and the changed level was maintained until the end of monsoon period. Nutrient concentrations and turbidity increased and values of the other parameters were declined as a result of water dilution. This rainfall event, Changma, is a meteorological phenomenon caused by the East-Asian monsoon climate. The magnitude and frequency of the rainfall during the early monsoon play an important role in change of water quality and ecosystem characteristics of large river systems.

A study of the cause of metal failure in treatment of femur shaft fracture - Fractographical and clinical analysis of metal failure- (대퇴골 간부 골절시 사용한 금속물의 금속부전(Metal failure)의 기전에 대한 연구)

  • Jeon, Chun-Bae;Seo, Jae-Sung;Ahn, Jong-Chul;Ahn, Myun-Whan;Ihn, Joo-Chyl
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.81-93
    • /
    • 1990
  • The author fractographically analyized the cause of metal failure(the first time this procedure has been used for this metal failure)and also analyized it clinically. In this study, I selected eight cases which have been analyized fractographically. In all these cases, the analysis was done after treatment of metal failure of implants internally fixed to femur shaft fractures at the Department of Orthopedic Surgery, Yeung-Nam University Hospital during the six year period from May 1983 to September 1989. 1. Metal failure occured in five dynamic-compression plates, one Jewett nail, one screw in Rowe plate, and one interlocking nail. 2. The clinical cause of metal failure was deficiency of medial butress in five cases, incorrect position of implant in one case, and incorrect selection of implant in two cases. 3. The time interval between internal fixation and metal failure was four months in one case, between five months to twelve months in six cases, three years in one case. 4. The fractographically analytical cause of metal failure was ; first, impact failure, one case, second, fatigue failure, six cases, machining mark(stress liser), four cases type : low consistent cyclic fatigue failure irregular cyclic fatigue failure third, stress corrosion crack, one case. 5. 316L Stainless Steel has good resistance to corrosion. However, when its peculiar surface film is destroyed by fretting, it shows pitting corrosion. This is, perhaps, the main cause of metal failure. 6. It is possible that mechanical injury occured in implants during the manufacturing of implants or that making a screw hole is the main cause of metal failure.

  • PDF

LI-RADS Treatment Response versus Modified RECIST for Diagnosing Viable Hepatocellular Carcinoma after Locoregional Therapy: A Systematic Review and Meta-Analysis of Comparative Studies (국소 치료 후 잔존 간세포암의 진단을 위한 LI-RADS 치료 반응 알고리즘과 Modified RECIST 기준 간 비교: 비교 연구를 대상으로 한 체계적 문헌고찰과 메타분석)

  • Dong Hwan Kim;Bohyun Kim;Joon-Il Choi;Soon Nam Oh;Sung Eun Rha
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.331-343
    • /
    • 2022
  • Purpose To systematically compare the performance of liver imaging reporting and data system treatment response (LR-TR) with the modified Response Evaluation Criteria in Solid Tumors (mRECIST) for diagnosing viable hepatocellular carcinoma (HCC) treated with locoregional therapy (LRT). Materials and Methods Original studies of intra-individual comparisons between the diagnostic performance of LR-TR and mRECIST using dynamic contrast-enhanced CT or MRI were searched in MEDLINE and EMBASE, up to August 25, 2021. The reference standard for tumor viability was surgical pathology. The meta-analytic pooled sensitivity and specificity of the viable category using each criterion were calculated using a bivariate random-effects model and compared using bivariate meta-regression. Results For five eligible studies (430 patients with 631 treated observations), the pooled per-lesion sensitivities and specificities were 58% (95% confidence interval [CI], 45%-70%) and 93% (95% CI, 88%-96%) for the LR-TR viable category and 56% (95% CI, 42%-69%) and 86% (95% CI, 72%-94%) for the mRECIST viable category, respectively. The LR-TR viable category provided significantly higher pooled specificity (p < 0.01) than the mRECIST but comparable pooled sensitivity (p = 0.53). Conclusion The LR-TR algorithm demonstrated better specificity than mRECIST, without a significant difference in sensitivity for the diagnosis of pathologically viable HCC after LRT.

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.