• Title/Summary/Keyword: dynamic fatigue

Search Result 611, Processing Time 0.029 seconds

Ultrasonic Fatigue Test for a High Strength Steel Plate (고장력 강판의 초음파 피로시험)

  • Yeom, Hyunho;Jung, Yongchan;Kim, Chayeong;Kang, Ki-Young;Lee, Moon Gu;Hong, Min-Sung;Jeon, Yongho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.6
    • /
    • pp.589-593
    • /
    • 2015
  • The demand of high cycle fatigue behavior on plate material is increasing because of its various applications. However, the high-cycle fatigue life data of the plate material is very rare compared to the rod material. Thus, in this study, a plate specimen is designed for the ultrasonic fatigue test because it is time efficient as compared to the conventional fatigue test. To apply the ultrasonic fatigue test, the specimen design is required to resonate at 20 kHz. Therefore, the dynamic elastic modulus was determined by measuring the resonance frequency with a piezoelectric element and laser doppler vibrometer (LDV). As a result, the plate specimen is designed and demonstrated using the ultrasonic fatigue testing machine. The ultrasonic fatigue test results were compared with the hydraulic fatigue test results.

Fatigue experiments on steel cold-formed panels under a dynamic load protocol

  • Garcia-Palencia, Antonio J.;Godoy, Luis A.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.3
    • /
    • pp.387-402
    • /
    • 2013
  • A dynamic load protocol has been used to experimentally simulate fatigue behavior in cold-formed metal panels with screwed connections under wind loading. The specific protocol adopted is an adaptation of SIDGERS, originally developed for non-metallic membranes, which is composed of levels each under increasing load values. A total of 19 tests were performed on 3.35 m long by 0.91 m wide panels, identified as Type B-wide rib and Type E, both with screw connections at the edge and at the center, thus conforming two-span specimens. In some configurations the panels were fixed at the valleys, whereas crest-fixed connections were also investigated. Reinforcing the connections by means of washers was also investigated to evaluate their efficiency in improving fatigue capacity. The experimental results show maximum load capacities in improved connections with washers of approximately twice of those with classical connections.

Material Characteristics of Dental Implant System with In-Vitro Mastication Loading

  • Jeong, Tae-Gon;Jeong, Yong-Hun;Lee, Su-Won;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Gang, Gwan-Su
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.72-72
    • /
    • 2018
  • A dynamic fatigue characteristic of dental implant system has been evaluated with applying single axial compressive shear loading based on the ISO 14801 standard. For the advanced dynamic fatigue test, multi-directional force and motion needed to be accompanied for more information of mechanical properties as based on mastication in oral environment. In this study, we have prepared loading and motion protocol for the multi-directional fatigue test of dental implant system with single (Apical/Occlusal; AO), and additional mastication motion (Lingual/Facial; LF, Mesial/Distal; MD). As following the prepared protocol (with modification of ISO 14801), fatigue test was conducted to verify the worst case results for the development of highly stabilized dental implant system. Mechanical testing was performed using an universal testing machine (MTS Bionix 858, MN, USA) for static compression and single directional loading fatigue, while the multi-directional loading was performed with joint simulator (ADL-Force 5, MA, USA) under load control. Basically, all mechanical test was performed according to the ISO 14801:2016 standard. Static compression test was performed to identify the maximum fracture force with loading speed of 1.0 mm/min. A dynamic fatigue test was performed with 40 % value of maximum fracture force and 5 Hz loading frequency. A single directional fatigue test was performed with only apical/occlusal (AO) force application, while multi directional fatigue tests were applied $2^{\circ}$ of facial/lingual (FL) or mesial/distal (MD) movement. Fatigue failure cycles were entirely different between applying single-directional loading and multi-directional loading. As a comparison of these loading factor, the failure cycle was around 5 times lower than single-directional loading while applied multi-directional loading. Also, the displacement change with accumulated multi-directional fatigue cycles was higher than that of single directional cycles.

  • PDF

Estimation of Fatigue Strength in Resistance Spot Weldment of the Vehicle Body (차체 저항 점 용접부 피로수명 예측)

  • 손광재;양영수;조성규;장상균
    • Journal of Welding and Joining
    • /
    • v.20 no.2
    • /
    • pp.59-64
    • /
    • 2002
  • When the vehicle travels in an actual road, resistance spot weldments of the vehicle structure are exposed to complex loading state. Since the fatigue strength in resistance spot weldment of vehicle body can be determined by effect of residual stresses and loading state of driving, estimating actual loading state and considering residual stress effect are needed. In this study, Fatigue stress-fatigue life relation concerned residual stress effect was obtained by thermo elastic plastic finite element analysis. And applied loading in resistance spot weldments of vehicle body was calculated by dynamic analysis. Presumption of fatigue life was performed using proposed method

Fatigue Life Evaluation of Diesel Locomotive Car body Considering Camber Effect (캠버를 고려한 디젤기관차 차체 피로수명평가)

  • Jun, Hyun-Kyu;Lee, Dong-Hyung;Kim, Jae-Chul;Lee, Chan-Woo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.372-377
    • /
    • 2008
  • Camber with positive deflection is one of the very important design parameters in the manufacture of railway coach. Positive camber is defined as concave shape such as an arch and it increases the strength of structure remarkably. But during the operation of a structure, the positive camber turns into negative camber and it loses the strength of structure. Therefore we should consider the camber effect when we evaluate the fatigue strength of negative cambered structure. For this purpose, we made a model of negative cambered locomotive car body and performed structural analysis and also we measured the dynamic loads at critical points during commercial line operation. Fatigue strength of locomotive was calculated by applying Miner's damage accumulation rule. Fatigue strength of the two locomotives which have different camber were compared to find out the effect of camber on dynamic load amplitude. We found that the more negative camber a locomotive had, the shorter fatigue strength obtained.

  • PDF

Vibration Analysis and Durability Evaluation of a Sign Frame on a Bridge (교량부속구조물에 대한 진동해석과 피로내구성평가)

  • Lee, Sang-Hun;Endo, Takao;Ishikawa, Masami;Han, Yeon-Hee
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.317-320
    • /
    • 2008
  • Between traffic-induced vibration of a bridge and fatigue damage of its attached structures are very closely related. But any evaluation and design method considering the fatigue damage is not established yet. As an experimental method of evaluation of the fatigue durability, a method based on cumulative damage using a stress range histogram has been often used. However, to use the method, the fatigue durability of unmeasured points could not be evaluated. Then, in this paper, dynamic analysis of a sign frame on a bridge is carried out based on the vibration data of the bridge. And model optimization was performed for good agreement between measured responses and computed responses. As a result, we could get stress range histograms and calculate fatigue durability of unmeasured points.

  • PDF

Influence of Shoe Heel Height and Muscle Fatigue on Static and Dynamic Balance in Healthy Young Women (신발 굽 높이와 근피로가 젊은 여성의 정적 및 동적 균형에 미치는 영향)

  • Kim, Yu-Jin;Koo, Jung-Wan;Oh, Duck-Won
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.36-44
    • /
    • 2013
  • This study aimed to investigate the influence of shoe heel height and muscle fatigue on static and dynamic balance in young women. Thirty women who were used to wearing high heels volunteered to participate in this study. The shoe heel heights were 0 cm and 7 cm. And ankle plantar flexor fatigue was experimentally induced. Static and dynamic balance were measured using the one leg standing test (OLST) and the star excursion balance test (SEBT) in anterior, posteromedial, and posterolateral directions, respectively. Values in the OLST (shoe heel height 0 cm, $28.83{\pm}3.24$ sec to $26.12{\pm}6.13$ sec; and 7 cm, $24.75{\pm}7.09$ sec to $16.86{\pm}9.32$ sec) and the SEBT in anterior (shoe heel height 0 cm, $71.02{\pm}4.57%$ to $69.50{\pm}3.66%$; and 7 cm, $64.17{\pm}3.53%$ to $59.61{\pm}4.06%$) and posteromedial (shoe heel height 0 cm, $92.01{\pm}5.61%$ to $90.38{\pm}7.10%$; and 7 cm, $83.09{\pm}7.29%$ to $76.83{\pm}9.28%$) directions were significantly reduced when fatigue-inducing exercise was performed (p<.05). Furthermore, within these parameters, there were significant interaction effects between shoe heel height and fatigue condition (p<.05). These findings suggest that shoe heel height and muscle fatigue contribute to some changes in static and dynamic balance in young women, probably leading to negative effects on physical function during a variety of activities of daily living.

The Effect of Noise and Background Music on the Trunk Muscle Fatigue during Dynamic Lifting and Lowering Tasks (들기/내리기 작업 시 소음과 배경음악이 몸통근육 피로도에 미치는 영향)

  • Kim, Jung-Yong;Shin, Hyun-Joo;Lee, In-Jae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.15-22
    • /
    • 2008
  • The purpose of this study was to define the effects of noise and background music on the trunk muscle fatigue during dynamic lifting and lowering tasks. Six healthy male subjects with no prior history of low back disorders participated in this study. The participants were exposed to two levels of background noise such as 40dB noise and 90dB noise and three levels of background music such as no music, slow music, and fast music. Six different combinations of background noise and background music were played while the participants were performing the lifting task at 15% level of Maximum Voluntary Contraction. Electromyography signals from six muscles were collected and fatigue levels were analyzed quantitatively. In results, the 90dB noise increased trunk muscle fatigue and slowed down the recovery. The trunk muscle fatigue was the lowest when the fast music was played for as background. After recovery, the 90dB noise increased trunk muscle fatigue. The trunk muscle fatigue was the lowest when the slow music was played for as background. The results can be useful to manage the cumulative fatigue of trunk muscles due to background noise and music during repetitive lifting and lowering tasks in industry.

An Evaluation of Notch Shpae for Estimation of Available $K_{1d}$ by Instrumented Charpy Impact Test (유효 $K_{1d}$ 산정을 위한 샬피 충격시험편의 노치형상에 관한 연구)

  • 우창기;강동명;이하성
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.6
    • /
    • pp.135-143
    • /
    • 1999
  • This investigation evaluates effects of notch depth, fatigue precrack length and side groove in impact specimen for estimation of a valid K1d by instrumented Charpy impact test. Specimen material is 6005-T6. for notch depth 2.0mm and 2.5mm specimens or within about 2mm fatigue precrack length with notch depth 2.0mm and 2.5mm specimens or within about 2mm fatigue precrack length with notch depth 2.0mm , dynamic fracture toughness [$K_{1d,(1)}$] obtained by crack initiation load($P_m$) should be used. Dynamic fracture toughness of side grooved specimens are overestimated to that of standard impact specimen about 15 %-20%. It is confirmed that the formula of dynamic fracture toughness obtained by impact absorbed energy is inappropriate for ductile materials.

  • PDF

Fatigue Reliability Evaluation of Steel-Composite High-Speed Railway Bridge with Tuned Mass Damper (동조질량감쇠기를 장착한 강합성형 고속철도교의 피로신뢰성 평가)

  • Kang, Soo-Chang;Seo, Jeong-Kwan;Koh, Hyun-Moo;Park, Kwan-Soon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.1-10
    • /
    • 2005
  • This study proposes a fatigue reliability evaluation procedure for steel-composite high-speed railway bridge based on dynamic analysis and investigates the effectiveness of Tuned Mass Damper(TMD) in terms of the extension of fatigue life of the bridge. For the fatigue reliability evaluation, the limit state is determined using S-N curve and linear fatigue-damage accumulation. Dynamic analyses are peformed repeatedly to consider the uncertainties of train-velocity and damping ratio of the bridge. The distribution of random variables related to fatigue damage for the intended service life is then statistically estimated from analytical results. Finally, the fatigue reliability indices are obtained by means of the Advanced First-Order Second-Moment (AFOSM) method. Through numerical simulation of a steel-composite bridge of 40m span, the effectiveness of TMD on fatigue life of the bridge is examined and the results are presented.