• Title/Summary/Keyword: dynamic compensation

Search Result 469, Processing Time 0.023 seconds

Comparison of Center of Pressure Displacement during Sit to Stand to Sit and Balance Ability of Subjects with and without Chronic Ankle Instability

  • Hyun-Sung Kim;Seung-Jun Oh
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.1
    • /
    • pp.13-20
    • /
    • 2023
  • Purpose : The purpose of this study is to compare the balance ability between subjects with chronic ankle instability and normal people and the center of pressure displacement during the sit to stand and stand to sit. Methods : The subjects of this study were 63 who met the inclusion criteria and were classified into normal group (n=33) and chronic ankle instability group (n=30). The displacement of the center of pressure during sit to stand and stand to sit was measured. And the limit of stability and Y-balance tests were performed to measure the balance ability. Independent t-test was conducted to compare center of pressure displacement and balance ability between groups, and pearson correlation was conducted to analyze the correlation between the center of pressure displacement and balance ability. Results : In the case of the center of pressure displacement, there was a significant difference between the two groups during sit to stand and stand to sit. In the case of balance, both limit of stability and Y-balance test showed significant differences between the two groups. At the time of sit to stand, the center of pressure displacement showed a significant correlation with balance abilities, and at the time of stand to sit, the center of pressure displacement showed a significant correlation with Y-balance test. Conclusion : Chronic ankle instability shows that there is a lot of sway in the body due to compensation to replace the decrease in ankle joint range of motion when performing sit to stand and stand to sit due to sensory input damage such as decrease in ankle range of motion and decrease in ankle proprioception. Chronic ankle instability is expected to have a negative effect on our daily lives in life. The results of this study will serve as the basis for the dynamic approach to objective evaluation, treatment, and prevention of chronic ankle instability.

Developing a Portable Intelligent Projection System (휴대형 지능형 프로젝션 시스템 개발)

  • Park, Han-Hoon;Seo, Byung-Kuk;Jin, Yoon-Jong;Oh, Ji-Hyun;Park, Jong-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.26-34
    • /
    • 2007
  • Intelligent projection system indicates a system that displays desired images on an arbitrary screen in an arbitrary environment using projector without noticeable image distortion. In recent years, projectors have become widespread and ubiquitous due to their increasing capabilities and declining cost. Moreover, the size of projectors is getting smaller and handhold projectors are emerging. Thanks to these advances, the demand for intelligent projection system has been significantly increased and the demand has led to remarkable progress of the related techniques or technologies to intelligent projection system However, there are still some environments (or conditions, mainly dynamic ones) that intelligent projections systems cannot handle and they have limited the application area of intelligent projection systems. This paper exemplifies such environments (e.g. specular screen, dynamic screen) and propose effective solutions (i.e. multiple overlapping projectors, complementary pattern embedding) for thor And the usefulness of the solutions is verified through experimental results and user evaluation. Notice that the environments are considered not simultaneously but independently because it is impossible to consider them simultaneously by simply combining the solutions for each. Acually, a totally different solution would be necessary to consider them simultaneously. Therefore, we expect that the proposed methods would largely extend the application area of intelligent projection systems except for severely arbitrary environment.

A 0.31pJ/conv-step 13b 100MS/s 0.13um CMOS ADC for 3G Communication Systems (3G 통신 시스템 응용을 위한 0.31pJ/conv-step의 13비트 100MS/s 0.13um CMOS A/D 변환기)

  • Lee, Dong-Suk;Lee, Myung-Hwan;Kwon, Yi-Gi;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.75-85
    • /
    • 2009
  • This work proposes a 13b 100MS/s 0.13um CMOS ADC for 3G communication systems such as two-carrier W-CDMA applications simultaneously requiring high resolution, low power, and small size at high speed. The proposed ADC employs a four-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. Area-efficient high-speed high-resolution gate-bootstrapping circuits are implemented at the sampling switches of the input SHA to maintain signal linearity over the Nyquist rate even at a 1.0V supply operation. The cascode compensation technique on a low-impedance path implemented in the two-stage amplifiers of the SHA and MDAC simultaneously achieves the required operation speed and phase margin with more reduced power consumption than the Miller compensation technique. Low-glitch dynamic latches in sub-ranging flash ADCs reduce kickback-noise referred to the differential input stage of the comparator by isolating the input stage from output nodes to improve system accuracy. The proposed low-noise current and voltage references based on triple negative T.C. circuits are employed on chip with optional off-chip reference voltages. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.70LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 64.5dB and a maximum SFDR of 78.0dB at 100MS/s, respectively. The ABC with an active die area of $1.22mm^2$ consumes 42.0mW at 100MS/s and a 1.2V supply, corresponding to a FOM of 0.31pJ/conv-step.

A Study on Robust and Precise Position Control of PMSM under Disturbance Variation (외란의 변화가 있는 PMSM의 강인하고 정밀한 위치 제어에 대한 연구)

  • Lee, Ik-Sun;Yeo, Won-Seok;Jung, Sung-Chul;Park, Keon-Ho;Ko, Jong-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1423-1433
    • /
    • 2018
  • Recently, a permanent magnet synchronous motor of middle and small-capacity has high torque, high precision control and acceleration / deceleration characteristics. But existing control has several problems that include unpredictable disturbances and parameter changes in the high accuracy and rigidity control industry or nonlinear dynamic characteristics not considered in the driving part. In addition, in the drive method for the control of low-vibration and high-precision, the process of connecting the permanent magnet synchronous motor and the load may cause the response characteristic of the system to become very unstable, to cause vibration, and to overload the system. In order to solve these problems, various studies such as adaptive control, optimal control, robust control and artificial neural network have been actively conducted. In this paper, an incremental encoder of the permanent magnet synchronous motor is used to detect the position of the rotor. And the position of the detected rotor is used for low vibration and high precision position control. As the controller, we propose augmented state feedback control with a speed observer and first order deadbeat disturbance observer. The augmented state feedback controller performs control that the position of the rotor reaches the reference position quickly and precisely. The addition of the speed observer to this augmented state feedback controller compensates for the drop in speed response characteristics by using the previously calculated speed value for the control. The first order deadbeat disturbance observer performs control to reduce the vibration of the motor by compensating for the vibrating component or disturbance that the mechanism has. Since the deadbeat disturbance observer has a characteristic of being vulnerable to noise, it is supplemented by moving average filter method to reduce the influence of the noise. Thus, the new controller with the first order deadbeat disturbance observer can perform more robustness and precise the position control for the influence of large inertial load and natural frequency. The simulation stability and efficiency has been obtained through C language and Matlab Simulink. In addition, the experiment of actual 2.5[kW] permanent magnet synchronous motor was verified.

Optimal Payment Contracts in Agent-Owner Relationship (대리인-선주간의 최적보상계약에 관한 연구)

  • 육근효
    • The Journal of Fisheries Business Administration
    • /
    • v.18 no.1
    • /
    • pp.37-57
    • /
    • 1987
  • This article discussed the characteristics of several Pareto-optimal incentive contracts between owner and labor, more specifically, four situations: reporting output jointly observable by labor ana owner; reporting both output and effort; incorporating other endogenous elements (like capital) that affect the production process and Pareto-optimal fee schedules; and ascertaining the effects of private pre-decision information private- decision information, and per-contact informational asymmetries. Also presented were several extensions of the basic contractual model, and the different components of agency costs associated with labor-owner contractual relations. In a single-period model, the agency problem exists because the uncertainty prevents the owner from using the cash flow to determine unambiguously the labor's action. Holmstrom(1979) suggests that "when the same situation repeats itself over time, the effects of uncertainty tend to be reduced and dystunctional behavior is more accurately revealed, thus alleviating the problem of moral hazard. " Under these conditions, if the labor selects the first-best level of effect in each period, the cash flow will be independent and identically distributed over time. As the number of periods increases, the variance of the labows average output, if he selects the first-best level of effort in each period, gets smaller. Note that for this diversification effect to occur, it is necessary that the owner evaluate the labor's effort over the entire history of his employment, rather than evaluate each period's performance separately. Radner(1980) and Rubinstein and Yaari(1980) consider the extreme case in which there are an infinite number of observations. They show that the owner can eventually detect and systematic shirking on the part of the labor by comparing the labor's average output with what would be expected if the labor had been selecting the first-best level of effort in each period. In a dynamic model with incentive problems we have demonstrated that the labor's second-period compensation will depend on his first-period performance. This allows the owner to diversify away some of the uncertainty surrounding the labor's actions. In addition, this allows the owner to smooth the labor's income over time by spreading the risk of the first-period outcome over both periods. At least some unexplored avenves in this area invite future accounting research: situations where owner has different incompatible objectives and negotiates a contract with labor; circumstances in which owner deals with multiple objectives and negotiates contracts with several labors simultaneously; the value of costly accounting information systems and communication in establishing, Pareto-optimal incentive contracts, and the value and effects of inside information, Thorough theoretical or empirical research on each of these topics not only would increase our knowledge about the role and significance of accounting information but could also provide explanations of the inherent differences among various organizations and in their economic behavior. behavior.

  • PDF

Studies for the Audiences' Welfare Effects from the Real Time Retransmission of Terrestrial TV Channels through the PayTV Networks (유료방송 매체를 통한 지상파채널 재전송의 후생효과 연구)

  • Byun, Sang-Kyu
    • Korean journal of communication and information
    • /
    • v.48
    • /
    • pp.63-89
    • /
    • 2009
  • The contents provided by the terrestrial broadcasters have governed the market based on their excellent quality in Korea. In spite of the launching of various pay TV services focusing on multi-channel, it is not yet easy to find out the substitutionary pay TV channels for the terrestrial. Therefore, the real time retransmission of the terrestrial channels brings about the crucial effects on the pay TV's competency, especially on the new media as the invisible barrier. So it is frequently proposed to change the aim of the retransmission policy from the universal access to the promotion of media industries. The retransmission can be divided into two types as the must carry and retransmission consent. In Korean situation, keeping or reducing the must carry channel would be appropriate rather than expanding them. However, periodic investigation into the public effects of the must carry is necessary, instead of it. Moreover, the rational and fair monetary compensation for the commercial channels(MBC, SBS, KBS2) is arising as the bottle neck in the retransmission agreements between the broadcasters. The conjoint analysis was carried out to estimate the welfare growth from the retransmission, based on the stated preference from the audiences' point of view. For must carry channels, it was certified as the 'win-win' strategy for both sides and audiences. For the commercial channels, it is revealed to be beneficial to the audiences. Thereafter, the standards for the rational price were suggested to promote the retransmission. This can contribute for inspiring the dynamic vitality to the media industry by reinforcing the contents competencies and for establishing the long term growth strategies.

  • PDF

Differences in Static Lower Extremity Alignment according to the History of Lateral Ankle Sprain: Efficacy and Limitation of Static Lower Limb Alignment Measurement as a Predictor of Lateral Ankle Sprain (외측 발목 염좌 병력에 따른 정적 하지 정렬 차이: 외측 발목 염좌의 예측인자로서 정적 하지 정렬 검사의 효용성과 한계점)

  • Jeon, Hyung Gyu;Ha, Sunghe;Lee, Inje;Kang, Tae Kyu;Kim, Eun Sung;Lee, Sae Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.1-15
    • /
    • 2021
  • Objective: The aim of this study was to investigate 1) the difference in static lower extremity alignment (SLEA) according to a history of lateral ankle sprain (LAS), 2) to identify SLEA factors affecting LAS, and 3) to present the cut-off value and 4) the usefulness and limitations of the SLEA measurement. Method: This case-control study recruited 88 men (age: 27.78±4.69 yrs) and 39 women (age: 24.62±4.20 yrs) subjects with and without LAS. SLEA measurement protocol included Q angle, tibiofemoral angle, genu recurvatum, rear foot (RF) angle, tibal varum and torsion, navicular drop, ankle dorsiflexion range of motion (DF ROM). Independent t-test, logistic regression and receiver operating characteristic (ROC) curve were used for statistical analysis. Results: Men with a history of LAS had significantly smaller Q angles both in standing and in supine position, while women with a history of LAS had significantly greater DF ROM in non-weight bearing (NWB; p < 0.05). Logistic regression model suggests tibial varum (OR = 0.779, p = 0.021) and WB DF ROM (OR = 1.067, p = 0.045) were associated with LAS in men. In case of women, there were no significant SLEA factors for LAS, however, ROC curve analysis revealed standing RF angle (AUC = 0.647, p = 0.028) and NWB DF ROM (AUC = 0.648, p = 0.026) could be affecting factors for LAS. Conclusion: There are differences in SLEA according to the history of LAS, furthermore, the identified items were different by sex. In case of men, tibial varum and WB DF ROM affect LAS occurrence. Standing RF angle and NWB DF ROM of women could be a predictor for LAS. However, since the sensitivity and specificity in most of the SLEA measurements are low, kinematic in dynamic tasks should be considered together for a more accurate evaluation of LAS risk.

Respiratory air flow transducer calibration technique for forced vital capacity test (노력성 폐활량검사시 호흡기류센서의 보정기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Jang, Jong-Chan;Kim, Seong-Sik;Lee, Su-Ok;Jung, Jae-Kwan;Park, Kyung-Soon;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1082-1090
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is a very important diagnostic parameter obtained from the forced vital capacity(FVC) test. The expiratory flow rate increases during the short initial time period and may cause measurement error in PEF particularly due to non-ideal dynamic characteristic of the transducer. The present study evaluated the initial rise slope($S_r$) on the flow rate signal to compensate the transducer output data. The 26 standard signals recommended by the American Thoracic Society(ATS) were generated and flown through the velocity-type respiratory air flow transducer with simultaneously acquiring the transducer output signal. Most PEF and the corresponding output($N_{PEF}$) were well fitted into a quadratic equation with a high enough correlation coefficient of 0.9997. But only two(ATS#2 and 26) signals resulted significant deviation of $N_{PEF}$ with relative errors>10%. The relationship between the relative error in $N_{PEF}$ and $S_r$ was found to be linear, based on which $N_{PEF}$ data were compensated. As a result, the 99% confidence interval of PEF error was turned out to be approximately 2.5%, which was less than a quarter of the upper limit of 10% recommended by ATS. Therefore, the present compensation technique was proved to be very accurate, complying the international standards of ATS, which would be useful to calibrate respiratory air flow transducers.

Utility Evaluation on Application of Geometric Mean Depending on Depth of Kidney in Split Renal Function Test Using 99mTc-MAG3 (99mTc-MAG3를 이용한 상대적 신장 기능 평가 시 신장 깊이에 따른 기하평균 적용의 유용성 평가)

  • Lee, Eun-Byeul;Lee, Wang-Hui;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.199-208
    • /
    • 2016
  • $^{99}mTc-MAG_3$ Renal scan is a method that acquires dynamic renal scan image by using $^{99}mTc-MAG_3$ and dynamically visualizes process of radioactive agent being absorbed to kidney and excreted continuously. Once the test starts, ratio in both kidneys in 1~2.5 minutes was measured to obtain split renal function and split renal function can be expressed in ratio based on overall renal function. This study is based on compares split renal function obtained from data acquired from posterior detector, which is a conventional renal function test method, with split renal function acquired from the geometric mean of values obtained from anterior and posterior detectors, and studies utility of attenuation compensation depending on difference in geometric mean kidney depth. From July, 2015 to February 2016, 33 patients who undertook $^{99}mTc-MAG_3$ Renal scan(13 male, 20 female, average age of 44.66 with range of 5~70, average height of 160.40cm, average weight of 55.40kg) were selected as subjects. Depth of kidney was shown to be 65.82 mm at average for left and 71.62 mm at average for right. In supine position, 30 out of 33 patients showed higher ratio of deep-situated kidney and lower ratio of shallow-situated kidney. Such result is deemed to be due to correction by attenuation between deep-situated kidney and detector and in case where there is difference between the depth of both kidneys such as, lesions in or around kidney, spine malformation, and ectopic kidney, ratio of deep-situated kidney must be compensated for more accurate calculation of split renal function, when compared to the conventional test method (posterior detector counting).