• Title/Summary/Keyword: dynamic analysis method

Search Result 5,934, Processing Time 0.037 seconds

Closed-form and numerical solution of the static and dynamic analysis of coupled shear walls by the continuous method and the modified transfer matrix method

  • Mao C. Pinto
    • Structural Engineering and Mechanics
    • /
    • v.86 no.1
    • /
    • pp.49-68
    • /
    • 2023
  • This study investigates the static and dynamic structural analysis of symmetrical and asymmetrical coupled shear walls using the continuous and modified transfer matrix methods by idealizing the coupled shear wall as a three-field CTB-type replacement beam. The coupled shear wall is modeled as a continuous structure consisting of the parallel coupling of a Timoshenko beam in tension (with axial extensibility in the shear walls) and a shear beam (replacing the beam coupling effect between the shear walls). The variational method using the Hamilton principle is used to obtain the coupled differential equations and the boundary conditions associated with the model. Using the continuous method, closed-form analytical solutions to the differential equation for the coupled shear wall with uniform properties along the height are derived and a numerical solution using the modified transfer matrix is proposed to overcome the difficulty of coupled shear walls with non-uniform properties along height. The computational advantage of the modified transfer matrix method compared to the classical method is shown. The results of the numerical examples and the parametric analysis show that the proposed analytical and numerical model and method is accurate, reliable and involves reduced processing time for generalized static and dynamic structural analysis of coupled shear walls at a preliminary stage and can used as a verification method in the final stage of the project.

Evaluation of Seismic Performance for Bridge Structure Using Capacity Spectrum Method (역량스펙트럼법을 이용한 교량의 내진성능평가)

  • 이창수;김승익;김현겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.75-80
    • /
    • 2000
  • Evaluation method of seismic performance has mainly used elastic spectrum analysis. This method has simplicity of analysis but deficiency of accuracy. And evaluation method of seismic performance using inelastic dynamic analysis reflects accurately inelasticity of material but hardly reflects site effects. This study suggested evaluation scheme of seismic performance for bridge structure using capacity spectrum method applied inelastic static analysis and standard design response spectrum of Korea Standard Specification for Highway Bridge. Two results, capacity spectrum method and inelastic dynamic analysis method, are very similar. As a result, this study appropriately supply both simplicity of analysis and accuracy of result.

  • PDF

The Comparision of Analysis Methods in dynamic Design of Dam based on Shaking Table tests (진동대시험에 근거한 댐의 내진설계시 해석 방법의 비교)

  • Hwang, Seong-Choon;Oh, Byung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.732-737
    • /
    • 2005
  • This paper performed pseudo static analysis and dynamic analysis for CFRD and evaluated reliability with the results of Shaking Table Test. The Seismic coefficient method, modified seismic coefficient method, Newmark method of Pseudo static analysis and frequency domain response analysis, time domain history analysis of dynamic analysis were used. The analysis results were differ between analysis method, but the trends of acceleration and displacement were good agreement with the results of shaking table test.

  • PDF

Investigation on the Determination Method of Rayleigh Damping Coefficients for Dynamic Time History Elastic-Plastic Seismic Analysis (동적 시간이력 탄소성 지진 해석을 위한 레일레이 감쇠계수 결정방법 고찰)

  • Kim, Jong Sung;Lee, Seok Hyun;Kweon, Hyeong Do;Oh, Chang-Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.2
    • /
    • pp.38-43
    • /
    • 2017
  • This paper investigates how to determine the Rayleigh damping coefficients for dynamic time history seismic analysis of piping systems. Three methods are applied. The first one is a conventional method to use the natural frequencies of the mode 1 and 2, derived from dynamic analysis. The second method is to determine the Rayleigh damping coefficients based on frequency range of the acceleration histories. The last one is a iterative transient response analysis method using the transient analysis results without and with damping. It is found that the conventional method and the iterative transient response method yield the same results whereas the acceleration frequency-basis method provides more conservative result than the other methods. In addition, it is concluded that the iterative transient response method is recommended.

Numerical study of dynamic buckling for plate and shell structures

  • Liu, Z.S.;Lee, H.P.;Lu, C.
    • Structural Engineering and Mechanics
    • /
    • v.20 no.2
    • /
    • pp.241-257
    • /
    • 2005
  • A numerical approach combining the finite element method with two different stability criteria namely the Budiansky and the phase-plane buckling criteria is used to study the dynamic buckling phenomena of plate and shell structures subjected to sudden applied loading. In the finite element analysis an explicit time integration scheme is used and the two criteria are implemented in the Finite Element analysis. The dynamic responses of the plate and shell structures have been investigated for different values of the plate and shell imperfection factors. The results indicate that the dynamic buckling time, which is normally considered in predicting elasto-plastic buckling behavior, should be taken into consideration with the buckling criteria for elastic buckling analysis of plate and shell structures. By selecting proper control variables and incorporating them with two dynamic buckling criteria, the unique dynamic buckling load can be obtained and the problems of ambiguity and contradiction of dynamic buckling load of plate and shell structure can be resolved.

Study on the durability assessment based on CAE analysis (CAE 해석 기반 내구도 평가 방법에 대한 연구)

  • 주병현;남기원;이병채
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.844-848
    • /
    • 2004
  • We evaluate the durability of vehicle chassis component under dynamic loadings. Since the fatigue analysis of vehicle component is based on the dynamic load history it must be done by dynamic analysis. But in case the vehicle component has natural frequencies much larger than reversing frequencies of load history, we can get small analysis errors by applying quasi-static analysis. So it is inefficient that we apply to the dynamic analysis for all the vehicle components. In this research, we discuss the quasi-static analysis method which is appropriate for the fatigue analysis. And in case we can only perform the fatigue analysis based on dynamic analysis, we introduce more efficient method in the analysis time and hard disk storage.

  • PDF

Stability behavior of the transmission line system under incremental dynamic wind load

  • Sarmasti, Hadi;Abedi, Karim;Chenaghlou, Mohammad Reza
    • Wind and Structures
    • /
    • v.31 no.6
    • /
    • pp.509-522
    • /
    • 2020
  • Wind load is the principal cause for a large number of the collapse of transmission lines around the world. The transmission line is traditionally designed for wind load according to a linear equivalent method, in which dynamic effects of wind are not appropriately included. Therefore, in the present study, incremental dynamic analysis is utilized to investigate the stability behavior of a 400 kV transmission line under wind load. In that case, the effects of vibration of cables and aerodynamic damping of cables were considered on the stability behavior of the transmission line. Superposition of the harmonic waves method was used to calculate the wind load. The corresponding wind speed to the beginning of the transmission line collapse was determined by incremental dynamic analysis. Also, the effect of the yawed wind was studied to determine the critical attack angle by the incremental dynamic method. The results show the collapse mechanisms of the transmission line and the maximum supportable wind speed, which is predicted 6m/s less than the design wind speed of the studied transmission line. Based on the numerical modeling results, a retrofitting method has been proposed to prevent failure of the tower members under design wind speed.

Optimization of a vehicle component under dynamic fatigue (동적 피로를 고려한 자동차 부품의 최적설계)

  • 이정준;주병현;이병채
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.898-901
    • /
    • 2004
  • Generally, in case the natural frequency of vehicle components is larger than the reversing frequency of load history, we can obtain the analysis results with small errors. But in case of having the low natural frequency, we must avoidably carry out the dynamic analysis, and it requires much time and storage. Specially executing the fatigue analysis for vehicle components requires more time. To this end, it is not easy that we accomplish the optimization considering fatigue for the vehicle component based on the dynamic analysis. In this research we introduce an efficient method which performs the fatigue analysis based on the dynamic analysis. Finally as making the response surface we optimize the vehicle component under dynamic fatigue.

  • PDF

Structural Optimization under Equivalent Static Loads Transformed from Dynamic Loads Based on Displacement (변위에 기초한 동하중에서 변환된 등가정하중하에서의 구조최적설계)

  • Gang, Byeong-Su;Choe, U-Seok;Park, Gyeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.8 s.179
    • /
    • pp.1949-1957
    • /
    • 2000
  • All the loads in the real world act dynamically on structures. Since dynamic loads are extremely difficult to handle in analysis and design, static loads are utilized with dynamic factors. The dyna mic factors are generally determined based on experiences. Therefore, the static loads can cause problems in precise analysis and design. An analytical method based on modal analysis has been proposed for the transformation of dynamic loads into equivalent static load sets. Equivalent static load sets are calculated to generate an identical displacement field in a structure with that from dynamic loads at a certain time. The process is derived and evaluated mathematically. The method is verified through numerical tests. Various characteristics are identified to match the dynamic and the static behaviors. For example, the opposite direction of a dynamic load should be considered due to the vibration response. A dynamic bad is transformed to multiple equivalent static loads according to the number of the critical times. The places of the equivalent static load can be different from those of the dynamic load. An optimization method is defined to use the equivalent static loads. The developed optimization process has the same effect as the dynamic optimization which uses the dynamic loads directly. Standard examples are solved and the results are discussed

Dynamic Analysis of Structures by Component Mode Method using Ritz-Lanczos Algorithm (Ritz-Lanczos알고리즘을 이용한 Component mode Method에 의한 구조물의 동적 해석)

  • 심재수
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.151-158
    • /
    • 1997
  • The main concern of numerical dynamic analysis of large structures is to find an acceptable solution with fewer mode shapes and less computational efforts. component mode method utilizes substructure technique to reduce the degrss of freedom but have a disadvantage to not consider the dynamic characteristics of loads. Ritz Vector method consider the load characteristics but requires many integrations and errors are accumulated. In this study, to prove the effectiveness of component mode method, Lanczos algorithm are introduced. To prove the effectiveness of this method, example structures areanalyzed and the results are compared with SAP90.

  • PDF