• 제목/요약/키워드: dynamic CT

검색결과 152건 처리시간 0.023초

Effects of trunk control robot training on balance and gait abilities in persons with chronic stroke

  • Lim, Chae-gil
    • Physical Therapy Rehabilitation Science
    • /
    • 제9권2호
    • /
    • pp.105-112
    • /
    • 2020
  • Objective: To investigate the effects of training using a trunk control robot (TCR) system combined with conventional therapy (CT) on balance and gait abilities in persons with chronic stroke. Design: Two-group pretest-posttest design. Methods: Thirty-five subjects with chronic stroke were randomly assigned to either the TCR group (n=17) or the trunk extension-training (TET) group (n=18). Both groups performed CT for 30 minutes, after which the TCR group performed TCR training and the TET group performed trunk extension training for 20 minutes. Both groups performed the therapeutic interventions 3 days per week for 6 weeks. Balance ability was evaluated using the Berg Balance Scale (BBS), and the Timed Up-and-Go (TUG) test. Gait ability was measured using the 10 m Walk Test (10MWT) and the NeuroCom Smart Balance Master. Results: TCR group showed significant improvements in static balance (weight bearing) and dynamic balance (weight shifting speed, weight shifting direction, BBS, and TUG), 10MWT, gait speed, and step width (p<0.05); step length was not significant. The TET group showed a significant partial improvement of dynamic balance (weight shifting speed, weight shifting direction, BBS, and 10MWT (p<0.05), but the improvements in static balance, TUG, gait speed, and step width and step length was not significant. Additionally, significant differences in static balance, dynamic balance (weight shifting speed, weight shifting direction, BBS, and TUG), 10MWT, gait speed, and step width were detected between groups (p<0.05). Conclusions: TCR training combined with CT is effective in improving static and dynamic balance, as well as gait abilities in persons with chronic stroke.

Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom (호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교)

  • Kim, Seong-Eun;Won, Hui-Su;Hong, Joo-Wan;Chang, Nam-Jun;Jung, Woo-Hyun;Choi, Byeong-Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제28권2호
    • /
    • pp.123-130
    • /
    • 2016
  • Purpose : The aim of this study was to compare the differences between the volumes acquired with four-dimensional computed tomography (4DCT)images with a reconstruction image-filtering algorithm and cone-beam computed tomography (CBCT) images with dynamic phantom. Materials and Methods : The 4DCT images were obtained from the computerized imaging reference systems (CIRS) phantom using a computed tomography (CT) simulator. We analyzed the volumes for maximum intensity projection (MIP), minimum intensity projection (MinIP) and average intensity projection (AVG) of the images obtained with the 4DCT scanner against those acquired from CBCT images with CT ranger tools. Results : Difference in volume for node of 1, 2 and 3 cm between CBCT and 4DCT was 0.54~2.33, 5.16~8.06, 9.03~20.11 ml in MIP, respectively, 0.00~1.48, 0.00~8.47, 1.42~24.85 ml in MinIP, respectively and 0.00~1.17, 0.00~2.19, 0.04~3.35 ml in AVG, respectively. Conclusion : After a comparative analysis of the volumes for each nodal size, it was apparent that the CBCT images were similar to the AVG images acquired using 4DCT.

  • PDF

The Algorithm Improved the Speed for the 3-Dimensional CT Video Composition (3D CT 동영상 구성을 위한 속도 개선 알고리즘)

  • Jeong, Chan-Woong;Park, Jin-Woo;Jun, Kyu-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • 제28권2호
    • /
    • pp.141-147
    • /
    • 2009
  • This paper presents a new fast algorithm, rotation-based method (RBM), for the reconstruction of 3 dimensional image for cone beam computerized tomography (CB CT) system. The system used cone beam has less exposure time of radioactivity than fan beam. The Three-Pass Shear Matrices (TPSM) is applied, that has less transcendental functions than the one-pass shear method to decrease a time of calculations in the computer. To evaluate the quality of the 3-D images and the time for the reconstruction of the 3-D images, another 3-D images were reconstructed by the radon transform under the same condition. For the quality of the 3-D images, the images by radon transform was shown little good quality than REM. But for the time for the reconstruction of the 3-D images REM algorithm was 35 times faster than radon transform. This algorithm offered $4{\sim}5$ frames a second. It meant that it will be possible to reconstruct the 3-D dynamic images in real time.

Atlantoaxial Rotatory Fixation - Report of 3 Cases - (Atlantoaxial Rotatory Fixation - 3 례 보 고 -)

  • Sohn, Moon Jun;Rhim, Seung Chul;Roh, Sung Woo;Park, Hyung Chun
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권4호
    • /
    • pp.580-585
    • /
    • 2000
  • The atlantoaxial rotatory fixation is a uncommon disease of deformity, occuring much more frequently in children than in adults. Despite of its benign clinical course, delayed recognition or improper management may cause persistent deformity or recurrence. We report three cases of typical atlantoaxial rotatory fixation. Successful reduction was achieved with posterior atlantoaxial fusion in one case and nonoperative treatment in others. We emphasize that it is necessary to perform dynamic CT scan to obtain correct diagnosis and to plan proper treatment for this disease entity.

  • PDF

A Study on the Usefulness of 3D Imaging in Micro-CT for Observing the Microstructure of Mice (흰쥐 미세구조 관찰을 위한 Micro-CT 3D 영상의 유용성에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Lim, Cheong-Hwan;Jung, Hong-Ryang;Chai, Kyu-Yun;Han, Beom-Hee;Han, Sang-Hyun;Hong, Dong-Hee;Han, Tae-Jong;Park, Sung-Hoon;Mo, Eun-Hee;Jun, Hong-Young
    • Journal of Digital Convergence
    • /
    • 제12권3호
    • /
    • pp.367-375
    • /
    • 2014
  • In this thesis we observe microvascular structure in mice by using micro-computed tomography (CT), which is high-resolution X-ray imaging equipment that can acquire Real-time dynamic image, and it aims to investigate the usefulness of micro-CT developed by Institute for Radiological Imaging Science Wonkwang University School of Medicine. After acquiring the systemic images of rats, contrast-enhanced 3D images of vascular structures could be acquired by using Maximum Intensity Projection (MIP) and Volume Rending Technique (VRT), This was divided into each vascular system of head, abdomen and heart and systemic vascular system.

Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT (13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제18권1호
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate changes of quantitative and semi-quantitative myocardial perfusion indices and image quality by image reconstruction methods in $^{13}N$-ammonia ($^{13}N-NH_3$) myocardial perfusion PET/CT. Materials and Methods: Data of 14 (8 men, 6 women) patients underwent rest and adenosine stress $^{13}N-NH_3$ PET/CT (Biograph TruePoint 40 with TrueV, Siemens) were collected. Listmode scans were acquired for 10 minutes by injecting 370MBq of $^{13}N-NH_3$. Dynamic and static reconstruction was performed by use of FBP, iterative2D (2D), iterative3D (3D) and iterative TrueX (TrueX) algorithm. Coronary flow reserve (CFR) of dynamic reconstruction data, extent(%) and total perfusion deficit (TPD) (%) measured in sum of 4-10 minutes scan were evaluated by comparing with 2D method which was recommended by vendor. The image quality of each reconstructed data was compared and evaluated by five nuclear medicine physicians through a blind test. Results: CFR were lower in TrueX 18.68% (P=0.0002), FBP 4.35% (P=0.1243) and higher in 3D 7.91% (P<0.0001). As semi-quantitative values, extent and TPD of stress were higher in 3D 3.07%p (P=0.001), 2.36%p (P=0.0002), FBP 1.93%p (P=0.4275), 1.57%p (P=0.4595), TrueX 5.43%p (P=0.0003), 3.93%p (P<0.0001). Extent and TPD of rest were lower in FBP 0.86%p (P=0.1953), 0.57%p (P=0.2053) and higher in 3D 3.21%p (P=0.0006), 2.57%p (P=0.0001) and TrueX 5.36%p (P<0.0001), 4.36%p (P<0.0001). Based on the results of the blind test for image resolution and noise from the snapshot, 3D obtained the highest score, followed by 2D, TrueX and FBP. Conclusion: We found that quantitative and semi-quantitative myocardial perfusion values could be under- or over-estimated according to the reconstruction algorithm in $^{13}N-NH_3$ PET/CT. Therefore, proper dynamic and static reconstruction method should be established to provide accurate myocardial perfusion value.

  • PDF

Comparison between Computer Tomography and Magnetic Resonance Imaging in the Diagnosis of Small Hepatocellular Carcinoma

  • Lertpipopmetha, Korn;Tubtawee, Teeravut;Piratvisuth, Teerha;Chamroonkul, Naichaya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권11호
    • /
    • pp.4805-4811
    • /
    • 2016
  • Background: Hepatocellular carcinomas (HCCs) less than 2 cm in diameter generally demonstrate a good outcome after curative therapy. However, the diagnosis of small HCC can be problematic and requires one or more dynamic imaging modalities. This study aimed to compare the sensitivity and agreement between CT and MRI for the diagnosis of small HCCs. Methods: CT and/or MRI scans of HCCs (1-2 cm) diagnosed by histopathology or typical vascular pattern according to the 2005 AASLD criteria were blindly reviewed by an abdominal radiologist. The reports were defined as conclusive/typical when arterial enhancement and washout during the portal/delayed phases were observed and as inconclusive when typical vascular patterns were not observed. The sensitivity and Cohen's kappa (k) for agreement were calculated. Results: In 27 patients, 27 HCC nodules (1-2 cm) were included. Diagnosis with a single-imaging modality (CT or MRI) was 81 % versus 48 % (p = 0.01). The CT sensitivity was significantly higher than MRI (78 % versus 52 %, p = 0.04). Among 27 nodules that underwent both CT and MRI, a discordance in typical enhancement patterns was found (k = 0.319, p = 0.05). In cases with inconclusive CT results, MRI gave only an additional 3.7 % sensitivity to reach a diagnosis. In contrast, further CT imaging following inconclusive MRI results gave an additional 29.6 % sensitivity.Conclusions: A single typical imaging modality is sufficient to diagnose small HCCs. Compared with MRI, multiphasic CT has a higher sensitivity. The limitations of MRI could be explained by the greater need for patient cooperation and the types of MRI contrast agent.

Submandibular sialolithiasis with CT and scintigraphy: CT values and salivary gland excretion in the submandibular glands

  • Ogura, Ichiro;Hayama, Kazuhide;Sue, Mikiko;Oda, Takaaki;Sasaki, Yoshihiko
    • Imaging Science in Dentistry
    • /
    • 제47권4호
    • /
    • pp.227-231
    • /
    • 2017
  • Purpose: Sialolithiasis is one of the most prevalent large obstructive disorders of the submandibular glands. The aim of this study was to investigate submandibular sialolithiasis with computed tomography (CT) and scintigraphy, with a particular focus on the relationship between CT values of the submandibular glands and their excretion rate. Materials and Methods: Fifteen patients with submandibular sialolithiasis who underwent CT and salivary gland scintigraphy were included in this study. The relationship between the CT values of submandibular glands with and without sialoliths and salivary gland excretion measured using salivary gland scintigraphy was statistically analyzed. Dynamic images were recorded on the computer at 1 frame per 20 seconds. The salivary gland excretion fraction was defined as A (before stimulation test [counts/frame]) / B (after stimulation test [counts/frame]) using time-activity curves. Results: The CT values in the submandibular glands with and without sialoliths was $9.9{\pm}44.9$ Hounsfield units(HU) and $34.2{\pm}21.8HU$, respectively (P=.233). Regarding the salivary gland excretion fraction using scintigraphy, the A/B value in the submandibular glands with sialoliths ($1.09{\pm}0.23$) was significantly lower than in the submandibular glands without sialoliths($1.99{\pm}0.57$, P=.000). Conclusion: Assessments of the CT values and the salivary gland excretion fraction using scintigraphy in the submandibular glands seem to be useful tools evaluating submandibular sialolithiasis.

A Study on Optimum Design for Railway Alignment in Curve (곡선부 최적 선형 설계기법에 관한 연구)

  • Um, Ju-Hwan;Yang, Sin-Chu;Kim, Eun-Kyum
    • Journal of the Korean Society for Railway
    • /
    • 제12권4호
    • /
    • pp.597-603
    • /
    • 2009
  • In this study, Based on the optimization developed in Um et al. (2009), optimum design method of the alignment when building new lines and renewing existing ones is presented. The object function used for optimization is passenger comfort ($P_{CT}$) which was proposed in BSI (2006). Other aspects of track/vehicle interaction will be treated in boundary conditions. And track/vehicle interaction analysis is peformed using KTX-II model. From the analysis results, it was found that the optimum alignments are affected by the angle (I) between adjacent straight lines and $R-L_t$ combinations. Also the dynamic analysis confirms well the results from the simplified analysis. However, In the most cases, the $P_{CT}$ values in the dynamic analysis are higher than the simplified $P_{CT}$ values. If both methods are used when optimizing the alignment, it will be possible to design the alignments more rapidly and reliably.

An Improved Dynamic Buffer Allocation Scheme for Controlled Transfer Service in ATM Networks (ATM 망에서 CT 서비스를 위한 개선된 동적 버퍼 할당 방식)

  • Kim, Byung-Chul;Kim, Dong-Ho;Cho, You-Ze;Kwon, Yul
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • 제36S권9호
    • /
    • pp.36-48
    • /
    • 1999
  • Controlled transfer (CT) service has been recently proposed as a new ATM transfer capability for high-speed data applications, which used a credit-based flow control. This paper investigates buffer allocation schemes for CT service and proposes an improved dynamic bugger allocation scheme. In order to improve the responsiveness to a congestion, the proposed method is considered the load factor of a link when determining the amounts of virtual connection (VC)s buffer allocation. Also, in this paper we compare the performance of the proposed method with those of the existing buffer allocation methods such as flow controlled virtual channels (FCVC) and zero queueing flow control (ZQFC) through simulation. Simulation results show tat the proposed scheme exhibits a better performance than the existing schemes in terms of throughput, fairness, queue length and link utilization.

  • PDF