• Title/Summary/Keyword: dvr

Search Result 263, Processing Time 0.021 seconds

Parameter Optimization of the LC filters Based on Multiple Impact Factors for Cascaded H-bridge Dynamic Voltage Restorers

  • Chen, Guodong;Zhu, Miao;Cai, Xu
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.165-174
    • /
    • 2014
  • The cascaded H-Bridge Dynamic Voltage Restorer (DVR) is used for protecting high voltage and large capacity loads from voltage sags. The LC filter in the DVR is needed to eliminate switching ripples, which also provides an accurate tracking feature in a certain frequency range. Therefore, the parameter optimization of the LC filter is especially important. In this paper, the value range functions for the inductance and capacitance in LC filters are discussed. Then, parameter variations under different conditions of voltage sags and power factors are analyzed. In addition, an optimized design method is also proposed with the consideration of multiple impact factors. A detailed optimization procedure is presented, and its validity is demonstrated by simulation and experimental results. Both results show that the proposed method can improve the LC filter design for a cascaded H-Bridge DVR and enhance the performance of the whole system.

Line-Interactive DVR Using Multi-Level H-Bridge Inverter (멀티-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR)

  • Kang Dae-Wook;Woo Sung-Min;Kim Tae-Jin;Choi Chang-Ho;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.139-143
    • /
    • 2001
  • Recently, the interest on power quality has been hot issue. The equipments cause voltage disturbance and has become more sensitive to the voltage disturbance. This paper deals with 5-Level H-Bridge Line-Inter active Dynamic Voltage Restorer(LIDVR) system. The LIDVR has following advantages in comparison with the DVR with series injection transformer It has the power factor near to unity under normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then a voltage controller is proposed to get sinusoidal load voltage with constant amplitude. To find PWM method suitable for H-Bridge converter, two PWM methods are compared and analyzed. Finally, simulation results verify the proposed 5-level H-Bridge LIDVR system.

  • PDF

A Voltage Control Technique of Line-Interactive DVR Using 7-Level H-Bridge Inverter (7-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR의 전압제어)

  • Kang, Dae-Wook;Hyun, Dong-Seok;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.705-715
    • /
    • 2007
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and have become more sensitive to the voltage disturbance. Additionally, the reseach on power electronic equipments applying to the high power has been increased. This paper deals with Line-Interactive Dynamic Voltage Restorer(LIDVR) system using 7-Level H-Bridge inverter, which is one of the solutions to compensate the voltage disturbance and to increase the power of equipments. The LIDVR has the following advantages comparing to the DVR with the series injection transformer. It has the power factor near to unity under the condition of normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then the voltage control algorithm is proposed to get the sinusoidal load voltage with constant amplitude. Finally, simulation and experiment results verify the proposed LIDVR system.

The Analysis of Zero Sequence Components in Dynamic Voltage Restorer System (영상성분을 고려한 DVR 기기 해석)

  • Jeong, Il-Yeop;Park, Sang-Yeong;Won, Dong-Jun;Mun, Seung-Il;Park, Jong-Geun;Han, Byeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.4
    • /
    • pp.169-174
    • /
    • 2002
  • The magnitude and phase of the compensating voltage in Dynamic Voltage Restorer (DVR) system depend on the voltage sag in the phases affected by the fault and on the influence of the zero sequence components. If the delta connection of the transformer is used, the zero sequence components do not appear on the load side. But nowadays, Y connected transformers with grounded neutral, that is 3-phase 4-wire system, are usually used. Therefore the zero-sequence components are occurred during faults. The zero-sequence components result in the high insulation costs and the asymmetry of the phase and magnitude of the terminal voltages. In this paper 3 phase 4 wire distribution system and 3 phase 3 wire system are analyzed and characteristics of voltage sag are presented. And this paper proposes the method that can mitigate the zero-sequence under the unbalance faults causing voltage sage and phase angle iumps.

Implementation of Video Surveillance System with Motion Detection based on Network Camera Facilities (움직임 감지를 이용한 네트워크 카메라 기반 영상보안 시스템 구현)

  • Lee, Kyu-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.169-177
    • /
    • 2014
  • It is essential to support the image and video analysis technology such as motion detection since the DVR and NVR storage were adopted in the real time visual surveillance system. Especially the network camera would be popular as a video input device. The traditional CCTV that supports analog video data get be replaced by the network camera. In this paper, we present the design and implementation of video surveillance system that provides the real time motion detection by the video storage server. The mobile application also has been implemented in order to provides the retrieval functionality of image analysis results. We develop the video analysis server with open source library OpenCV and implement the daemon process for video input processing and real-time image analysis in our video surveillance system.

Hemodynamic Evaluation of St. Jude Medical Prosthesis (센 쥬드 판막의 혈류 역학적 고찰)

  • 문광덕
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1122-1131
    • /
    • 1995
  • One hundred eighty-eight patients[August.23,1988,through July.30,1994 underwent aortic[AVR , mitral[MVR , or double [DVR valve replacement with the St.Jude Medical prosthesis. The author analyzed 100 patients with valvular heart disease,who underwent valve replacement with the St.Jude Medical prothesis from 1990 to 1994, at Hanyang University hospital Cardiovascular department. Information on volume and functional change of the heart chamber can be obtained by cardiac echocardiography and cartheterization. Out of 100 patients, 40 patients were male[40% and 60 patients were female [60% . Age ranged from 13 years to 68 years, with mean age of 42.6 years. Mean height was 160.3cm and mean body weight was 54.9Kg. According to NYHA functional classification, class III is most frequent and 60 patients could be classfied under it. MVR [involved Redo MVR was performed in 40 patients, AVR [involved Redo AVR was performed in 18 patients, and DVR [involved Redo DVR was performed in 42 patients. Warfarin [Coumadin anticoagulation was recommended for all patients. Life long warfarin anticoagulation was necessary to all patients who underwent valve replacement with St.Jude Medical prosthesis. Ideal prothrombin time was maintained about 30% during warfarinization. There were no case of mechanical failure. It followed a comparison of echocardiography before and after valve replacement at Hanyang University hospital [30 patients and a preoperative evaluation of cardiac catheterization and angiography [64 patients . The St.Jude Medical cardiac valve is a viable alternative in the surgical therapy of valvular heart disease.

  • PDF

Implementation of MPEG-4 Codec for Real-time DVR System Based on PC (PC 기반 실시간 DVR 시스템을 위한 MPEG-4 코덱 구현)

  • Jang Kyung Hyun;Park Ki Tae;Kim Chan Gyu;Hong In Hwa;Kim Jin Kook;Yeo Hun Gu;Moon Young Shik
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11b
    • /
    • pp.607-609
    • /
    • 2005
  • 본 논문에서는 실시간으로 다채널의 카메라에서 입력되는 영상을 동시에 압축 및 복원할 수 있는 PC 기반의 DVR (Digital Video Recording) 시스템을 위한 MPEG-4 방식의 코덱을 구현하고자 한다. 현재까지의 일반적인 압축 방식은 화상회의 용도의 H.263, VCD 화질의 MPEG-1, DVD급 화질인 MPEG-2가 널리 적용되고 있다. 하지만 이러한 방법들은 저장 데이터의 양이 커서 효율적인 저장이 어렵다. 따라서 본 논문에서는 이러한 문제점을 해결하면서 실시간적으로 다채널 영상 데이터 저장이 가능한 MPEG-4 압축 방식을 적용한 코덱을 제작한다.

  • PDF

Implementation of the mote Image Based Metering System bridging with PCS Network (PCS망을 연동한 원격영상 검침시스템 구현)

  • Lee, Chang-Su;Na, Jong-Ray;Hwang, Jin-Kwon
    • The KIPS Transactions:PartD
    • /
    • v.10D no.6
    • /
    • pp.1041-1048
    • /
    • 2003
  • This paper implements a remote image based metering(IBM) system which capture meter image, recognizes number automatically, and send the data wirelessly through PCS data network. We use existing gas/water meter and get NTSC camera image by installing small monochrome CMOS camera on the meter closely. For remote data transfer, we use SMS (short message service) that is provided by commercial PCS network. We developed DVR(digital video recorder) for capturing meter image and character recognition algorithm. In addition, hardware and software for SMS and meter selector were developed.

A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter (전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한 연구)

  • 장수진;류동균;서민성;김준호;원충연;이진국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.32-39
    • /
    • 2003
  • The output voltage of synchronous generator is regulated constantly by field current control in excitation system High frequency PWM converter (current control mode buck converter) type excitation systam fer synchronous generator is able to control exciter current when the load change happened. This paper deals with the design and evaluation of the excitation system for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is able to improve the response time by the DVR(digital voltage regulator) of 50[kW] synchronous generator.

An Implementation of a PCI Interface for H.264/AVC Encoder (H.264/AVC 인코더 용 PCI 인터페이스의 구현)

  • Park, Kyoung-Oh;Kim, Tae-Hyun;Hwang, Seung-Hoon;Hong, You-Pyo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9A
    • /
    • pp.868-873
    • /
    • 2010
  • H.264/AVC video compression standard has been adopted for DMB, digital TV and various next generation broadcasting, communication and consumer electronics applications, and modern DVR system is also based on H.264/AVC standard. Although PC-based DVRs use PCI bus for main interface typically, H.264/AVC codec for SOCs use AHB bus for host interface. In this paper, we present an implementation of PCI to AHB interface module for H.264/AVC codec to efficiently communicate with a PC and experimental results.