• 제목/요약/키워드: duty factor

검색결과 363건 처리시간 0.025초

와이어 펄스전해가공에서 반응표면분석법을 응용한 미세박판의 홀 가공 최적 조건에 관한 연구 (A Study on the Optimal Conditions of Hole Machining of Microplate by Application of Response Surface Methodology in Wire-Pulse Electrochemical Machining)

  • 송우재;이은상
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.141-149
    • /
    • 2017
  • Due to the inaccuracy of micro-machining, various special processing methods have been investigated recently. Among them, pulse electrochemical machining is a promising machining method with the advantage of no residual stress and thermal deformation. Because the cross section of the wire electrode used in this study is circular, wire-pulse electrochemical machining is suitable for micro-hole machining. By applying the response surface methodology, the experimental plan was made of three factors and three levels: machining time, duty factor, and voltage. The regression equation was obtained through experiments. Then, by referring to the main effect diagram, we fixed the duty factor and machining time with little relevance, and solved the equation for the target 900 microns to obtain the voltage value. The results obtained from the response surface methodology were approximately those of the target value when the actual experiment was carried out. Therefore, it is concluded that the optimal conditions for hole processing can be obtained by the response surface methodology.

중국인 관광객의 면세점 선택속성과 쇼핑 만족도 분석 : 부산지역 면세점을 중심으로 (Analysis of Duty-Free Shopping Attributes and Shopping Satisfaction of Chinese Tourists : Focusing on duty free shops in Busan)

  • 황성준;김동일
    • 디지털융복합연구
    • /
    • 제15권12호
    • /
    • pp.137-145
    • /
    • 2017
  • 본 연구는 방한 중국인 관광객의 면세점 선택속성을 파악하여 쇼핑만족도를 측정하고 쇼핑만족도를 높이기 위한 방안을 제시하고자 한다. 부산 시내면세점을 방문한 중국인 관광객을 대상으로 직접설문방법으로 설문조사를 수행하고 실증분석을 수행하였다. 본 연구의 분석 결과는 다음과 같다. 첫째, 면세점 선택속성을 세분화하기 위한 요인분석을 수행한 결과 점포속성, 제품속성, 서비스속성으로 분석되었다. 둘째, 이를 바탕으로 각각의 속성이 쇼핑만족도에 미치는 영향 관계를 분석한 결과 모두 통계적으로 유의한 양(+)의 결과를 나타내었다. 셋째, 분석 속성들이 만족도에 미치는 영향의 상대적 크기를 분석한 결과 점포속성이 가장 높은 것으로 나타났다. 즉, 면세점 점포, 서비스, 제품의 품질이 전반적인 쇼핑만족도를 높여주는 것으로 나타났다. 따라서 만족도에 영향을 미치는 속성의 품질 향상을 높이는 전략수행은 경영성과 개선에 기여할 것으로 보이며, 면세점 운영의 활성화 방안에 경영적인 시사점을 제안한다는 점에서 본 연구가 의미 있다고 할 수 있다. 향후 연구에서는 보다 다양한 형태의 쇼핑장소에 대한 연구가 이루어진다면 보다 의미 있을 것으로 생각된다.

Scaling Factor Design Based Variable Step Size Incremental Resistance Maximum Power Point Tracking for PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.164-171
    • /
    • 2012
  • Variable step size maximum power point trackers (MPPTs) are widely used in photovoltaic (PV) systems to extract the peak array power which depends on solar irradiation and array temperature. One essential factor which judges system dynamics and steady state performances is the scaling factor (N), which is used to update the controlling equation in the tracking algorithm to determine a new duty cycle. This paper proposes a novel stability study of variable step size incremental resistance maximum power point tracking (INR MPPT). The main contribution of this analysis appears when developing the overall small signal model of the PV system. Therefore, by using linear control theory, the boundary value of the scaling factor can be determined. The theoretical analysis and the design principle of the proposed stability analysis have been validated using MATLAB simulations, and experimentally using a fixed point digital signal processor (TMS320F2808).

무손실 스너버 회로를 이용한 소프트 스위칭 강압형 고역률 컨버터 (Soft switching high power factor buck converter using loss less snubber circuit)

  • 구헌회;변영복;김성철;서기영;이현우
    • 전자공학회논문지S
    • /
    • 제34S권6호
    • /
    • pp.77-84
    • /
    • 1997
  • buck type converter doesn't appear when an input voltag eis lower than an output voltage. This is the main reason the buck converter has not been used for high power factor converters. In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn on of the switching device is a zero current switching (ZCS) and high powr factor input is obtianed. In addition, zero voltage switching (ZVS) at trun off is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontinous conduction mode operation. High power factro, efficiency, soft switching operation of proposed converter is veified by simulation using Pspice and experimental results.

  • PDF

회귀분석을 이용한 전자접촉기의 접점소모 분석에 대한 고찰 (A study on Analysis of Contact erosion at a Magnetic Contactor with the Use of Regression Analysis)

  • 김명석;유행수;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.116-118
    • /
    • 2003
  • This paper describes a Accelerated Life Test (ALT) with the electrical contact erosion suitable to the evaluations of high-reliability and durability devices such as magnetic contactor. Recently, an electrical devices company was interested in accelerated life test (ALT), the product liability (PL) and the short-term testing model of electrical life test (ELT). In order to estimate a model for testing fee and period, need to the statistical analysis method with the acceleration factor(AF). Usually customer/manufacturer regard their device failure to the over-current or heavy duty condition, while devices view shape of contact erosion owing to operational duty problem. In this paper, additional method of evaluation estimated the operated cycles by weight of contact erosion with a used of regression analysis by MINITAB.

  • PDF

A New Z-Source Inverter Topology with High Voltage Boost Ability

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.714-723
    • /
    • 2012
  • A new Z-source inverter (ZSI) topology is developed to improve voltage boost ability. The proposed topology is modified from the switched inductor topology by adding some more inductors and diodes into inductor branch to the conventional Z-source network. The modulation methods developed for the conventional ZSI can be easily utilized in the proposed ZSI. The proposed ZSI has an ability to obtain a higher voltage boost ratio compared with the conventional ZSI under the same shoot-through duty ratio. Since a smaller shoot-through duty ratio is required for high voltage boost, the proposed ZSI is able to reduce the voltage stress on Z-source capacitor and inverter-bridge. Theoretical analysis and operating principle of the proposed topology are explicitly described. In addition, the design guideline of the proposed Z-source network as well as the PWM control method to achieve the desired voltage boost factor is also analyzed in detail. The improved performances are validated by both simulation and experiment.

대형디젤엔진의 열적 피로안전도 분석을 위한 유한요소해석 (Finite Element Analysis of Thermal Fatigue Safety for a Heavy-Duty Diesel Engine)

  • 조남효;이상업;이상규;이상헌
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.122-129
    • /
    • 2004
  • Finite element analysis was performed to analyze structural safety of a new heavy-duty direct injection diesel engine. A half section of the in-line 6-cylinder engine was selected as a computational domain. A mapping method was used to project heat transfer coefficients from CFD results of engine coolant flow onto the FE model. The accurate setting of thermal boundary condition on the FE model was expected to result in improved prediction of temperature, cylinder bore distortion, and stresses. Characteristics of high cycle fatigue were investigated by assuming the engine was operated under the following five loading conditions repeatedly; assembly force, assembly force with thermal loading, alternating maximum gas pressure loading at each cylinder combined with assembly force and thermal loading. Distribution of fatigue safety factor was calculated by using it Haigh diagram in which the maximum and the minimum stresses were selected from the five loading cases.

상용 병렬형 하이브리드 시스템의 동력원 용량에 따른 연비 및 비용의 상관관계 분석 (Analysis of Correlation of Fuel Efficiency and Cost Depending on Component Size of Heavy-duty Parallel Hybrid System)

  • 정종렬;이대흥;신창우;임원식;박영일;차석원
    • 한국자동차공학회논문집
    • /
    • 제19권3호
    • /
    • pp.73-82
    • /
    • 2011
  • Most of countries start to restrict the emission gases of vehicles especially CO2 because of the global warming. Many vehicle companies including Toyota have launched various HEVs to satisfy the restriction laws and to improve the vehicle's efficiency. However, development for heavy-duty hybrid system is not plentiful rather than the passenger car. In this study, we choose the optimal size of engine, motor and battery for heavy-duty hybrid systems using dynamic programming. Also we analyze the correlation of the system's cost and efficiency because the added cost of vehicle to make the hybrid system is very important factor for the manufacturing companies. Finally, this study suggests a method to choose the appropriate system components size considering its performance and the cost. With this method, it is possible to select the component size for various systems.

PC 사용 환경에 기반한 2.5 인치 하드 디스크의 수명주기 예측에 대한 연구 (The Study on Estimating Life Cycle of 2.5 Inch Hard disk base on PC using enviroment)

  • 조의현;박정규;이민우;권순무
    • 디지털콘텐츠학회 논문지
    • /
    • 제15권2호
    • /
    • pp.301-308
    • /
    • 2014
  • 최근에 데이터가 대용량화됨에 따라 정보 저장의 중요성이 부각되고 있다. 본 연구는 대용량 저장장 치에 많이 사용되는 2.5인치 HDD에 대해서 가속 시험결과를 토대로 연간 제품 고장률을 예측하고 사용 환경에 대한 연간 제품 고장률과의 차이를 최소화 시키는 새로운 방안을 제시하고자 한다. 반품된 2.5인치 HDD 309개의 정보를 분석하여 실사용 환경의 시간당 전송량을 구했고, 가속 수명시험으로부터 가속 시험조건의 시간당 전송량을 구한 후, 사용률에 대한 가속 계수를 산출했다. 온도에 대한 가속 계수, 사용률에 대한 가속 계수와 고장률로 연간 제품 고장률을 예측하였다. 가속 시험의 시간당 전송량 81.4GB/hour와 사용자 93.4 %까지 대표하는 실사용 환경의 시간당 전송량은 5.8 GB/hour로 산출한 사용률에 대한 가속 계수는 14.1이다. 실사용 환경의 연간 제품 고장률은 1년 이후 안정화 되었으며, 이때 연간 제품 고장률은 0.3~0.378 % 이내에서 변동 하였다. 본 연구를 통하여 예측된 연간 제품 고장률은 0.4 %로 실사용 환경의 연간 제품 고장률과 75~94%의 일치됨을 보였다. 본 연구는 제조사의 가속수명 결과로 실사용 환경을 연간 제품 고장률을 예측하는 방법에 영향을 줄 것이다.

Soft Switching방식 고역률 강압형 컨버터 (Soft Switching High Power Factor Buck Converter)

  • 구헌회;조기연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.243-246
    • /
    • 1997
  • In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, a input capacitor can be small enough to filter input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn of of the switching device is a zero current switching(ZCS) and high power factor input is obtained. In addition, zero voltage switching(ZVS) at turn of is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontious conduction mode operation.

  • PDF