Developing Job Description for Dietitians Working in Public Health Nutrition Areas (보건소 영양사를 위한 직무 기술서 개발)

  • Cha, Jin-A;Park, Hae-Ryun;Lim, Young-Suk;Lim, Seung-Hee
    • Korean Journal of Community Nutrition
    • /
    • v.13 no.6
    • /
    • pp.890-902
    • /
    • 2008
  • The purpose of this study was to develop a standardized job description for dietitians working in the public health nutrition area. Work-oriented job analysis methodology was employed for the study purpose. Subjects of 38 dietitians currently working at health centers in 2002 were recruited. Based on the focus group interview with 7 public health nutritionists and 7 professors, information about task elements was collected. Questionnaires measuring work performance and self-perception of importance of the selected task elements were administered. Reliability and validity of this instrument were tested by Chronbach's alpha and factor analysis. SAS PC package program was used for the statistical analysis. The final developed job description for public health nutritionists included 5 duties, 20 tasks and 93 task elements. The results of this study can be summarized as follows; 1) 5 duty areas are A. plan and evaluation of public health nutrition services, B. developing nutrition education materials, C. implementing nutrition services, D. networking community, and E. self development. 2) Each duty area from A to E was composed with 6, 2, 6, 4, 2 tasks, respectively. 3) Each duty area from A to E was composed with 24, 8, 38, 14, 9, and 2 task elements, respectively.

Organizational Commitment and Its Related Factor among Medium Hospitals of Nurses (종합병원 간호사의 조직몰입과 관련요인)

  • Lee, Young-Mee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.4764-4769
    • /
    • 2011
  • This study intends to investigate the organizational commitment and Its related factors among medium hospital of nurses. The collected data were analyzed descriptive statistics, t-test, ANOVA, Scheffe's test, Pearson correlation coefficient and stepwise multiple regression using SPSS 19.0 Program. The score of level of organizational commitment was statistically significant difference according to working period, marital state, monthly income, personality, night-duty. The score of organizational commitment level correlated positively with job satisfaction and burnout. Stepwise multiple regression analysis for organizational commitment level revealed that the most powerful predictor was burnout, job satisfaction and night-duty explained 49.5% of the variance. Therefore, It suggested that goal of increasing nurses' organizational commitment in hospital should be helped them raise job satisfaction and decrease nurses' burnout and night duty.

Flyback AC-DC Converter with Low THD Based on Primary-Side Control

  • Chang, Changyuan;He, Luyang;Cao, Zixuan;Zhao, Dadi
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1642-1649
    • /
    • 2018
  • A single-stage flyback LED AC-DC converter based on primary-side control under constant current mode is proposed in this study. The proposed converter features low total harmonic distortion (THD) and high power factor (PF). It also consists of a zero-crossing distortion compensation circuit and a variable duty ratio control compensation circuit to deal with the line current distortions caused by fixed duty ratio control. The system model and layout are built in Simplis and Cadence, respectively. The feasibility and performance of the proposed circuit is verified by designing and fabricating an IC controller in the HHNEC $0.35{\mu}m$ 5 V/40 V HVCMOS process. Experimental results show that the PF can reach a level in the range of 0.985-0.9965. Moreover, the average THD of the entire system is approximately 10%, with the minimum being 6.305%, as the input line voltage changes from 85 VAC to 265 VAC.

Single-Phase Series Type Quasi Z-Source Voltage Sag-Swell Compensator for Voltage Compensation of Entire Region (전 영역의 전압보상을 위한 단상 직렬형 Quasi Z-소스 전압 Sag-Swell 보상기)

  • Eom, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.322-332
    • /
    • 2013
  • Conventional single-phase series quasi Z-source voltage compensator can not compensate for voltage sag less than 50% that frequently occurs in the industrial field. In this study, single-phase series quasi Z-source voltage sag-swell compensator which can compensate the voltage variation of entire range is proposed. The proposed system is composed of two quasi Z-source AC-AC converters connected in series with output terminal stage. Voltage sag less than 50% could be compensated by the intersection switching control of the upper converter duty ratio and of the upper converter duty ratio. Also the compensation voltage and its flowchart for each compensation mode are presented for entire sag-swell region. To confirm the validity of the proposed system, a DSP(DSP28335) controlled experimental system was manufactured. As a result, the proposed system could compensate for the voltage sag/swell of 20% and 60%. Finally, voltage compensation factor and THD(Total Harmonic Distortion) according to voltage variation and load change were measured, and voltage quality shows a good results.

A study on the power factor improvement of the Boost Forward Converter (BF 컨버터의 역률 개선에 관한 연구)

  • 임승하
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.3
    • /
    • pp.56-63
    • /
    • 1999
  • In this paper, we realize the active PFC(Power Factor Correction) system of BF (Boost Forward) converter with PWM-PFM control technique to control DC output voltage, and to control the input current with sinusoidal wave synchronized by the converter and inverter using power switching element, FET and IGBT. The control circuit of the suggested Boost converter is implemented with a microprocessor 80C196. After making the ratio of output voltage to current as 50V/1A and the duty ratio greater than 0.5. When input voltage is 30V and boost inductance is 1.1mH. We control the voltage changing rate according to the variation of load resistance using a PWM-PFM control technique. And finally we prove experimentally. PF can be improved up to 0.96 using the current shaping technique.

  • PDF

A Noel Soft-Switching AC-DC Converter using $L^2SC$

  • Kim C. S.;Lee H. W.;Suh K. Y.;Kim H. D.;Kim K. T.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.271-275
    • /
    • 2001
  • In this paper, proposes a novel AC-DC converter of high power factor and high efficiency by partial resonant method. The input current waveform in proposed circuit is got to be a discontinuous sinusoidal form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Thereupon, the input power factor is nearly unity and the control circuit is simple. Also the switching devices in a proposed circuit are operated with soft switching by the partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. The partial resonant circuit makes use of a inductor using step up and $L^2SC$ (Loss-Less Snubber Condenser). The switching control technique of the converter is simplified for switches to drive in constant duty cycle. Some simulative results and experimental results are included to confirm the validity of the analytical results.

  • PDF

Off-time Control Method for High Power Density AC/DC Adapter (고전력밀도 AC/DC Adapter를 위한 off-time 제어법)

  • Kang, Shin-Ho;Jang, Jun-Ho;Hong, Sung-Soo;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.510-516
    • /
    • 2007
  • The proposed method offers an improved control method for high power density AC/DC adapter by using more energy efficient electrical equipments. Power factor correction (PFC) topology is based on boost topology with boundary conduction mode (BCM). DC/DC topology is based on half-bridge topology with fixed 50% duty and newly introduced off-time control method, which helps to reduce size of the semiconductor and the magnetic devices. Test results with 85W AC/DC adapter (18.5V/4.6A) design show that the measured efficiency is 90% with power density of $36W/in^3$. It also shows low no load power consumption of about 0.5W.

New Isolated Single-Phase AC-DC Converter for Universal Input Voltage

  • Lee, Ming-Rong;Yang, Lung-Sheng;Lin, Chia-Ching
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.592-599
    • /
    • 2013
  • This paper investigates a new isolated single-phase AC-DC converter, which integrates a modified AC-DC buck-boost converter with a DC-DC forward converter. The front semi-stage is operated in discontinuous conduction mode (DCM) to achieve an almost unity power factor and a low total harmonic distortion of the input current. The rear semi-stage is used for step-down voltage conversion and electrical isolation. The front semi-stage uses a coupled inductor with the same winding-turn in the primary and secondary sides, which is charged in series during the switch-on period and is discharged in parallel during the switch-off period. The discharging time can be shortened. In other words, the duty ratio can be extended. This semi-stage can be operated in a larger duty-ratio range than the conventional AC-DC buck-boost converter for DCM operation. Therefore, the proposed converter is suitable for universal input voltage (90~264 $V_{rms}$) and a wide output-power range. Moreover, the voltage stress on the DC-link capacitor is low. Finally, a prototype circuit is implemented to verify the performance of the proposed converter.

A 360Hz DC Ripple-Voltage Suppression Scheme in Three-Phase Soft-Switched Buck Converter (360Hz DC 리플-전압 감소기법을 사용한 3-Phase Soft-Switched Buck Converter)

  • Choi, Ju-Yeop;Ko, Jong-Jin;Song, Joong-Ho;Choy, Ick;Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.12
    • /
    • pp.813-820
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output in three phase buck diode converter is presented in this paper. The proposed pulse frequency modulation methods and duty ratio modulation methods are employed to regulate the output voltage of the buck diode converter and guarantee zero-current-switching(ZCS) of the switch over the wide load range. The proposed control methods used in this paper provide generally good performance such as low THD of the input line current and unity power factor. In addition, control methods can be effectively used to suppress the low frequency ripple voltage appeared in the dc output voltage. The harmonic injection technique illustrates its validity and effectiveness through the simulations and experiments.

  • PDF

Comparison of Correlation between CVS-75 Mode and Korea Mode to Estimate Emission Factors from Vehicles (자동차 오염물질 배출계수 산정을 위한 CVS-75모드와 국내차속모드의 상관성 비교 연구)

  • Jung, Sung-Woon;Ryu, Jeong-Ho;Lyu, Young-Sook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.383-391
    • /
    • 2006
  • In Korea, the major source of serious air pollution is motor vehicles. Air pollution from vehicles has been annually increased. Then the government will try to control the vehicle emission by applying the effective emission management policy for the manufactured and in-used car. It is necessary to correctly calculate the emission factor for successful propulsion of the vehicle emission control policy. In this study, correlation analysis of exhaust emissions from vehicles between CVS-75 mode and Korea mode was conducted. A total of 25 light-duty buses were tested on the chassis dynamometer system in order to measure CO, HC, NOx PM and fuel efficiency (F.E.). For the test modes, 10 different Korea modes and CVS-75 mode were used. As the result of correlation analysis between those modes, most of the correlation coefficients were higher than 0.90. On the basis of high correlation between those modes, correction factors by driving conditions were estimated. Through the results of this study, we obtained essential basic data to correct difference from those modes.