• Title/Summary/Keyword: duty factor

Search Result 363, Processing Time 0.026 seconds

Road-friendliness of Fuzzy Hybrid Control Strategy Based on Hardware-in-the-Loop Simulations

  • Yan, Tian Yi;Li, Qiang;Ren, Kun Ru;Wang, Yu Lin;Zhang, Lu Zou
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.148-154
    • /
    • 2012
  • Purpose: In order to improve road-friendliness of heavy vehicles, a fuzzy hybrid control strategy consisting of a hybrid control strategy and a fuzzy logic control module is proposed. The performance of the proposed strategy should be effectively evaluated using a hardware-in-the-loop (HIL) simulation model of a semi-active suspension system based on the fuzzy hybrid control strategy prior to real vehicle implementations. Methods: A hardware-in-the-loop (HIL) simulation system was synthesized by utilizing a self-developed electronic control unit (ECU), a PCI-1711 multi-functional data acquisition board as well as the previously developed quarter-car simulation model. Road-friendliness of a semi-active suspension system controlled by the proposed control strategy was simulated via the HIL system using Dynamic Load Coefficient (DLC) and Dynamic Load Stress Factor (DLSF) criteria. Results: Compared to a passive suspension, a semi-active suspension system based on the fuzzy hybrid control strategy reduced the DLC and DLSF values. Conclusions: The proposed control strategy of semi-active suspension systems can be employed to improve road-friendliness of road vehicles.

Strategy of Food Retailer and Delivery Rider's Accident in South Korea

  • KWAK, Young-Arm;CHO, Young-Sang
    • Journal of Distribution Science
    • /
    • v.18 no.5
    • /
    • pp.49-60
    • /
    • 2020
  • Purpose: The primary objective of this research is to propose answers of rider's accident of food retailer in South Korea, in view of business sustainability of food retailer and his precious fate of rider who is a father that has a responsibility to the family. Research design, data, and methodology: We investigated previous studies such as food retailer, delivery, delivery application of mobile, rider's accident and statistics of delivery business agency, motorcycle accident ratio, annual fatalist, and further we analyzed cases of rider's accidents. Results: Rider's accident on the road toward food retailer is serious risky factor to their business reputation, corporate image, because claim amount related to death and physical/mental disability can be heavily damaged to food retailer. The point when rider dies is that rider is a person responsible for supporting his/her family, that is, a life itself issue together with downfall of family. Conclusions: In view of growth of South Korean' delivery rider industry, the authors recommended that focus of stability and sustainablity of both food retailer and delivery rider should establish to executable and practical ideas such as rider's readiness, abandon of speed guarantee, duty of delivery app business and legal aids.

The Development of the Stress Measurement Tool for Staff Nurses working in the Hospital (간호원이 근무중에 경험하는 스트레스 측정을 위한 도구개발 연구)

  • 김매자;구미옥
    • Journal of Korean Academy of Nursing
    • /
    • v.14 no.2
    • /
    • pp.28-37
    • /
    • 1984
  • The purpose of this study is to propose the baseline data for developing the stress measurement tool for staff nurses working in the hospital. Two hundred and fifteen stan nurses in Seoul National University Hospital were participated during the period from Feb. 28 to Mar. 10, 1984. Though the pretest and literature review a questionnaire was constructed with 63 stressors which were experienced by the nurses in the hospital. Subjects were given instruction to rate 1∼6 likert type scale according to the level of stress experienced by each stressor described. Reliability of the tool was tested by Cronbach's Alpha, and the result was α=0.94871. Factor analysis was applied to organize 63 items together. As the result, 15 factors were obtained and these factors explained 66.3% of variance. The 15 factors were: 1) Work overload 2) Role conflict as a profession 3) Lack of professional knowledge and skill 4) Interpersonal problem 5) Conflict in nurse doctor relationship 6) Work conflict with doctors 7) Emotional burden due to the limitation of medicine 8) Poor treatment 9) Unsatisfactory relationship with supervisor 10) Low reward 11) Unsatisfactory relationship with subordinate 12) Poor physical environment of unit 13)Responsibility for extra affairs 14)Unfamiliar situation 15)Night duty.

  • PDF

Characteristic Analysis and Control of Three Phase PWM Buck AC-AC Converter (3상 PWM Buck AC-AC 컨버터의 특성해석과 제어)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1283-1290
    • /
    • 2003
  • Recently, PWM Buck AC-AC Converter is widely employed in various industrial applications such as voltage and power regulator, electronic transformer, phase shifter and so on. This paper presents static and dynamic modeling and complete characteristic analysis of a PWM Buck AC-AC converter. Firstly, the three phase converter system is modelled by using DQ transformation whereby we can obtain basic characteristic equations such as voltage gain and power factor as well as state equation and transfer function for control. Secondly, based on the analysis, the feedforward-feedback control technique is also proposed to obtain instantaneous duty level change whereby very fast dynamic response is achieved. Finally, the experimental results show the validity of the modeling, analysis and control.

A study on the pulse forming of pulsed $CO_2$ laser using active multi-pulse superposition (능동적 다중 펄스 중첩법(AMPS)을 적용한 펄스형 $CO_2$ 레이저의 펄스 성형에 대한 연구)

  • Chung, Hyun-Ju;Park, Sung-Joon;Jung, Yong-Ho;Song, Gun-Ju;Kim, Hee-Je;Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1631-1633
    • /
    • 2001
  • In manufacturing processes, various and suitable pulse shapes are required for the purpose of material processing and the pulseshape is regarded as a dominant factor due to the specific property of processing materials. Therefore, in this study, a variable pulse width, high duty cycle Pulse Forming Network(PFN) is constructed by time sequently. The power supply for this experiment consists of three switching circuits. The PFN elements operate at low voltage and drive the primary of HV leakage transformer. The secondary of the transformer has a full-wave rectifier, which passes the pulse energy to the load in a continuous sequence of properly phased and nested increments. We investigated laser pulse width as various delay time among three switching circuit. As a result, we tan obtain various laser pulse width from about 4ms to 10ms. The maximum laser pulse width obtained at this experiment was about 10ms at delay time of 4ms among each switching circuit.

  • PDF

Development and Evaluation of Shared Medical Decision-Making Scale for End-of-Life Patients in Korea (한국형 공유 의료적 의사 결정 측정도구 개발 및 평가)

  • Jo, Kae-Hwa
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.4
    • /
    • pp.453-465
    • /
    • 2012
  • Purpose: The study was done to develop a shared decision-making scale for end-of-life patients in Korea. Methods: The process included construction of a conceptual framework, generation of initial items, verification of content validity, selection of secondary items, preliminary study, and extraction of final items. The participants were 388 adults who lived in one of 3 Korean metropolitan cities: Seoul, Daegu, or Busan. Item analysis, factor analysis, criterion related validity, and internal consistency were used to analyze the data. Data collection was done from July to October 2011. Results: Thirty-four items were selected for the final scale, and categorized into 7 factors explaining 61.9% of the total variance. The factors were labeled as sharing information (9 items), constructing system (7 items), explanation as a duty (5 items), autonomy (4 items), capturing time (3 items), participation of family (3 items), and human respect (3 items). The scores for the scale were significantly correlated among shared decision-making scale, terminating life support scale, and dignified dying scale. Cronbach's alpha coefficient for the 34 items was .94. Conclusion: The above findings indicate that the shared decision-making scale has a good validity and reliability when used for end-of-life patients in Korea.

Harmonic Reduction in Three-Phase Boost Converter with Sixth Order Harmonic Injected PWM (6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감)

  • 이정호;김재문;이정훈;원충연;김영석;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.176-183
    • /
    • 2000
  • In this paper, sixth order hannonic injected PWM for improving‘ input CWTent distortion of single switch t three phase boost converter is presented. Peliodic sixth order hmmonic ${\gamma}$oltage is inj<:ded in the control circuit t to var${\gamma}$ the duty ratio of the converter switch within one switching cycle. In the result, the input phase c currents are forced to track the input voltage and an 해most unity power factor is obtained. Expelimental r results are verified by converter operating at 400V /6kW with three phase 140V ~220V input and by C02 arc w welding machine which was nonlinear load with 3 $\phi$ 220V input.

  • PDF

Research about most suitable control of small scale system link type photovoltaic system (소규모 계통연계형 태양광 시스템의 최적제어에 대한 연구)

  • Hwang L. H.;Jang E. S.;Nam W. Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.238-243
    • /
    • 2003
  • The solar cells should be operated at the maximum power point because its output characteristics are greatly fluctuated on the variation of insolation, temperature and load. The output power of solar cell is DC, therefore it is necessary to install an inverter among electric power converts. The inverter have to supply a sinusoidal current and voltage to the load and the interactive utility line. In the paper, the proposes a photovoltaic system designed with a step up chopper and single phase PWM voltage source inverter. Synchronous signal and control signal was processed by microprocessor for stable modulation. The step up chopper operates in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature because solar cell has typical dropping character. The single phase PWM voltage source inverter consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be developed continuously by connecting with the source of electric power, from 10 to $20\%$. The single phase PWM voltage source inverter operates in situation that its output voltage is in same phase with the utility voltage. The inverter supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

  • PDF

Design and Development of a High-Voltage Transformer-less Power Supply for Ozone Generators Based on a Voltage-fed Full Bridge Resonant Inverter

  • Amjad, Muhammad;Salam, Zainal;Facta, Mochammad;Ishaque, Kashif
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.387-398
    • /
    • 2012
  • It is known that transformer based power supplies for ozone generators have low efficiency, high cost and exhibits a limited frequency range of operation. To overcome these disadvantages, this paper proposes a high frequency ozone generator with the absence of a transformer. The voltage step-up is achieved only by utilizing the resonant tank. This is made possible by a novel combination of ozone chamber materials that allow ozone to be generated at only 1.5 - 3.5 $kV_{p-p}$. The input to the resonant tank is driven by a PWM full bridge resonant inverter. Furthermore, zero-current zero-voltage switching (ZCZVS) operation is achieved by employing a duty factor of 25% between the switches of the full bridge. The advantages of the proposed system include high efficiency, low cost and the ability to control ozone production by varying the input voltage to the inverter. The prototype is verified by both simulation and experimental results.

Die-sinking Electrical Discharge Machining with Ultrasonic Emission for Ceramic Matrix Composite (초음파 진동 부가에 의한 세라믹 복합체의 형조방전가공)

  • Wang, Duck-Hyun;Woo, Jeong-Yun;Yun, Jon-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.9-15
    • /
    • 1999
  • Die-sinking electrical discharge machining(EDM) for conductive ceramic matrix composite(CMC) of Tic/$Al_2O_3$ was experienced with addition of ultrasonic emission, and the results were compared with ones obtained by the EDM only. From this experimental study, the values of material removal rate(MRR) and surface roughness($R_{max}$), scanning electron microscope(SEM) micrographs, and weibull probability distribution of bending strength for the specimens were obtained and compared. The trend of MRR was found to be increased slightly with the current and the duty factor for both EDM only and EDM with ultrasonic emission. The MRR values were found to be increased for EDM with ultrasonic emission. The SEM micrographs of EDMed surface by under various operating conditions showed less micro cracks in various places. Although smaller bending strength value was obtained by EDMed surface with ultrasonic emission by weibull probability distribution analysis of bending strength.

  • PDF