• Title/Summary/Keyword: dust

Search Result 3,947, Processing Time 0.033 seconds

Seasons Variation of House Dust Mites Allergen and Perceived Allergic Symptoms (집먼지진드기 항원량과 알레르기 자각증상의 계절적 변화 - 알레르기 천식환자가구와 정상가구의 비교 -)

  • Kim Yong Soon;Park Jee Won;Song Young Shin
    • Journal of Korean Public Health Nursing
    • /
    • v.16 no.1
    • /
    • pp.30-44
    • /
    • 2002
  • The purpose of this study were to identify seasons variation of house dust mites allergen and perceived allergic symptom. The subjects were consisted of 29 family with allergy patients and 34 family without allergy patients. Perceived allergic symptoms were accessed and house dust was sampled from beds, floor of bedroom, kitchen and livingroom in spring(August), summer (July), fall(October) and winter(January) and tested using two-site ELISA. The results were as follows; 1) In all family, amount of house dust mites allergen(Der fI) of livingroom floor was the highest in summer$(4.73{\mu}g/1g\;of\;dust)$, and then fall$4.67{\mu}g/1g\;of\;dust)$, winter$(3.94{\mu}g/1g\;of\;dust)$, spring$(1.73{\mu}g/1g\;of\;dust)$. 2) In family with allergy patients, amount of house dust mites allergen(Der fI) of bedroom floor was highest in fall $(9.75{\mu}g/1g\;of\;dust)$. 3) In family with allergy patients, amount of house dust mites allergen(Der fI) of mattress was highest in fall$(8.23{\mu}g/1g\;of\;dust)$. 4) Perceived allergic symptom scores of family with allergy patients were higher than family without allergy patients in all seasons. In family without allergy patients, perceived allergic symptom scores was the highest in spring(4.29) and perceived allergic symptom scores of family with patients was the highest in winter(2.49). 5) The relationship of house dust mites allergen and perceived allergic symptom scores were positively related (r=.941, p=.000). Perceived allergic symptoms were correlated with amount of house dust mites allergen, That is, perceived allergic symptoms were became worse by house dust mites allergen. So House dust mites allergen reducing strategies and intervention should be recommended in further study.

  • PDF

China Dust-storm Monitoring Using Meteorological Satellite

  • Xiuqing, Hu;Naimeng, Lu;Peng, Zhang;Qian, Huang
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1224-1226
    • /
    • 2003
  • Dust-storm is one of the heaviest hazardous weather which frequently affects most part of northern China in spring. Satellite multi-spectral observations can provide significant information for detecting and quantitative determining the property of dust-storm . An algorithm to monitor dust-storm automatically was developed based on satellite observation. The algorithm utilizes split widows technique and spectral classification technique and also developed a new dust remote sensing product Infra -red Difference Dust Index (IDDI) proxy dust-loading dataset using GMS-5.

  • PDF

High Temperature Thermal Behavior of EAF Dust by Coke at Initial Reaction Stage (초기 반응단계에서 코크스에 의한 EAF DUST의 고온열적 거동)

  • 정봉진;배상민;문석민;신형기
    • Resources Recycling
    • /
    • v.7 no.5
    • /
    • pp.19-25
    • /
    • 1998
  • High temperature thermal behaviors of EAF dust by coke at initial reaction stage were studied to obtain the fundamental data of EAF dust treatment process, that is Extended Arc Plasma Furnace System called RAPID system. In this study thermal behaviors including calcination of limestone, devolatilization of EAF dust itself, and reduction & devolatilization of mixture(EAF dust : coke : limestone = 80 : 10 : 10 wt.%) were investigated as functions of reaction temperature (1000~1300$^{\circ}C$) and reaction time (3~12 min), considering the 180% equivalence of carbon reduction and 1.7 bacisity for optimum reduction and melting of EAF dust in the RAPID system. Size of sample was about below 0.1 mm for these experiments. Limestone was completely calcined at above 1100$^{\circ}C$ within 1 minutes. In the case of devolatilization of EAF dust itself, weight loss of EAF dust was about 14% at 1300$^{\circ}C$ and 12 minutes, and partial sintering and melting were found in part of sample. Weight loss of mixtures increased with increasing reaction temperature and time, about 46% weight loss in it was occurred at 1300$^{\circ}C$ and 12 minutes. From these weight losses showing devolatilization and reduction of EAF dust, the treatment time of EAF dust inside.

  • PDF

Exposure Assessment of Airborne Dust in Manufacturing Industries Using Silicon Carbide in Korea (우리나라 실리콘카바이드 취급사업장의 공기 중 분진 노출평가)

  • Lee, Jun Jung;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.177-183
    • /
    • 2011
  • Occupational exposure to silicon carbide dust of manufacturing industries has seldom been evaluated in Korea. Accordingly, we evaluated various silicon carbide dust concentrations in the breathing zone of workers between May 2010 and July 2010. To compare silicon carbide dust concentrations, three dust samplers including the Institute of Occupational Medicine (IOM) sampler, 37mm cassette sampler, and Aluminum cyclone sampler were used. A total of 5 manufacturing industries producing abrasive and refractory materials using silicon carbide were investigated. The geometric mean concentrations were 2.04, 0.97, and $0.48mg/m^3$ in inhalable, total and respirable silicon carbide dust, respectively. The geometric mean concentrations of silicon carbide in abrasive material manufacturing industries were slightly higher than that of refractory manufacturing industries, and finishing operations were higher than that of other operations. It was found that the results of exposure assessment in airborne dust at manufacturing industries using silicon carbide in Korea showed exceeding rate to American Conference of Governmental Industrial Hygienists Threshold Limit Value ($3mg/m^3$) was 10% in respirable dust samples. Therefore, with the consideration of the close relationship between smaller dust size and the occurrence of occupational respiratory diseases, it is suggested to promulgate the new occupational exposure limit for respirable silicon carbide dust.

Classification of Dust/Non-dust Particle from the Asian Dust Plumes and Retrieval of Microphysical Properties using Raman Lidar System (다파장 라만 라이다 시스템을 이용한 황사/비황사입자 구분 및 비황사입자의 미세물리적 특성 연구)

  • Shin, Sungkyun;Shin, Dongho;Lee, Kwonho;Noh, Youngmin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.688-696
    • /
    • 2012
  • The particle depolarization ratios were retrieved from the observation with a multi-wavelength Raman lidar at Gwangju, Korea ($35.11^{\circ}N$, $126.54^{\circ}E$). The measurements were carried out on 24 February and 9 March 2004. Using the particle depolarization ratios, the non-dust aerosol particles were distinguished from the Asian dust plume, and the proportion of the non-dust particle to total dust plume was retrieved. The calculated proportion of the non-dust particle was used for the retrieval of backscatter coefficients at 355, 532, and 1064 nm and extinction coefficients at 355 and 532 nm of non-dust particles in the dust plume. Microphysical parameters of non-dust particles including single-scattering albedo at 532 nm were retrieved using retrieved optical values. The retrieved single-scattering albedo of non-dust particles was 0.92~0.95 below 1 km height and 0.82~0.91 above 1 km height on 24 February 2004 and $0.81{\pm}0.03$ on 9 March 2004.

Effect of rate of strain on the strength parameters of clay soil stabilized with cement dust by product

  • Radhi M Alzubaidi;Kawkab Selman;Ayad Hussain
    • Geomechanics and Engineering
    • /
    • v.37 no.4
    • /
    • pp.419-429
    • /
    • 2024
  • The primary goal was to assess how the addition of cement dust, a byproduct known to be harmful, could be used to stabilize clay. Various percentages of cement dust were added to soil samples, which were then subjected to triaxial testing at different rates of strain using an unconsolidated undrained triaxial machine. Six different rates of strain were applied to analyze the response of the clay under different conditions, resulting in 216 triaxial sample tests. As the percentage of cement dust in the clay samples increased, there was a noticeable increase in the strength properties of the clay, indicating a positive effect of cement dust on the clay's strength characteristics. Higher rates of strain during testing led to increased strength properties of the clay. Varying cement dust content influenced the impact of increasing the rate of strain on the clay's strength properties. Higher cement dust content reduced the sensitivity of the clay to changes in strain rate, indicating that the clay became less responsive to changes in strain rate as cement dust content increased. Potential for Clay Stabilization Cement dust proved the potential to enhance the strength properties of clay, indicating its potential utility in clay stabilization applications. Both higher percentages of cement dust and higher rates of strain were found to increase the clay's strength. It's essential to consider both the percentage of cement dust and the rate of strain when assessing the strength properties of clay in practical applications.

Engineering Characteristics of Blast Furnace Slag Cement Mortar Using Chlorine Bypass System-Dust as Alkali Activator (Chlorine Bypass System-Dust를 알칼리 자극제로 사용한 고로슬래그 시멘트 모르타르의 공학적 특성)

  • Han, Min-Cheol;Lee, Dong-Joo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.2
    • /
    • pp.235-244
    • /
    • 2020
  • This study conducted a series of studies to offer a novel method of using CBS-dust that produced as by-product in the manufacture of cement. Four different contents of BS and CBS-dust were adopted for test parameters of this study. Mortar with 50% of W/B was fabricated. First, in the case of the fresh mortar, the flow decreased as the CBS-dust replacement rate increased, but the binder composition ratio BS 45% and 65% showed higher fl ow than Pl ain when repl acing CBS-dust 5%. In the case of air content, overall, the tendency was proportional to the CBS-dust replacement rate, and chloride tended to exceed the reference value at all replacement rates except for the CBS-dust 0% replacement. The compressive strength of the hardened mortar shows the resul t that the strength is improved when the CBS-dust is repl aced by 5% to 10%, and the CSH gel and structure formation is confirmed by microstructure analysis through the hydration reaction when the CBS-dust is replaced. Therefore, for a given condition CBS-dust is used as a early-strength admixture in a concrete secondary product that uses a large amount of admixture without reinforcing bars it can be an effective method for enhancing the strength of concrete as an alkali activator.

Physical properties of EAF dust-loaded glass-ceramics (EAF dust가 첨가된 결정화 유리의 물리적 특성)

  • Kang, Seung-Gu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.6
    • /
    • pp.242-247
    • /
    • 2008
  • The glass and glass-ceramics containing EAF dust $30{\sim}70\;wt%$ were fabricated and the dependance of physical properties upon crystal phases and microstructure formed was studied. The crystallization behavior of glass and glass-ceramics containing various contents of EAF dust composing of mainly $Fe_2O_3$ and ZnO was analyzed by crystal identification and microstructure observation. The glass specimen with EAF dust 30 wt% showed a typical amorphous pattern in XRD results and the specimen with above 30 wt% EAF dust had some un-dissolved crystals which was originated from EAF dust. The all glass-ceramics had franklinite, willemite and augite crystal phases. The density of glass-ceramics was higher than that of same composition glass, and it increased with EAF dust contents. In addition, the thermal and mechanical properties of glass-ceramics were always higher than those of glasses. In other words, the thermal expansion coefficient of glass increased with EAF dust contents while it decreased for the glass-ceramics. The vickers hardness for the glass and glass-ceramics increased with EAF dust content, the glass-ceramics always being higher those of glass of same composition.

The Characteristics of the Aerosol Number Concentration in Jeju Area During Asian Dust Events (황사 시 제주지역 에어로졸의 수농도 특성)

  • Kang, Chang-Hee;Hu, Chul-Goo
    • Journal of Environmental Science International
    • /
    • v.22 no.3
    • /
    • pp.347-358
    • /
    • 2013
  • The aerosol number concentration have measured with an aerodynamic particle sizer spectrometer(APS) at Gosan in Jeju Island, which is known as background area in Korea, from March 2010 to February 2011. The obtained results of asian dust events and non-asian dust period have been compared. The results show that the entire averaged aerosol number concentration from APS measurement during asian dust events and non-asian dust period are about 341 particles/$cm^3$ and 240 particles/$cm^3$, respectively. During asian dust events, the number concentration in small size ranges(${\leq}0.4{\mu}m$) are similar to non-asian dust period, however, those in large size ranges(${\geq}0.7{\mu}m$) are very higher than non-asian dust period. The contributions of the size resolved number concentration(23 channel in $0.25{\sim}10.0{\mu}m$) to total number concentration in that range are dramatically decreased with increased particle size. The contributions of smaller size ranges(${\leq}0.4{\mu}m$) during asian dust events are very low compared with non-asian dust period, on the other hand, those of larger size ranges(${\geq}0.4{\mu}m$) are higher than non-asian dust period. The number concentration in each size range are strongly correlated with the concentration in adjacent size range. And the total aerosol number concentration are depended on the number concentration in range of smaller than $0.58{\mu}m$ during non-asian dust period and asian dust events. On the other hand, $PM_{10}$ mass concentration has mainly affected with the number concentration in range of smaller than $1.0{\mu}m$ during non-asian dust period, however, during asian dust events, the mass concentration has mainly affected with the number concentration in range of $0.65{\sim}3.0{\mu}m$.

Metagenomic Analysis of Airborne Bacteria Community and Diversity in Gyeonggi-do, Korea, during March 2016, Asian Dust Event (2016년 한국 경기도의 3월 황사기간 동안 부유세균 군집과 다양성에 대한 메타지노믹 분석)

  • Jang, Jun Hyeong;Kim, Ji Hye;Bae, Kyung-seon;Kim, Jeong Myeong;Lee, Won seok;Chung, Hyen-mi;Park, Sangjung;Seo, Taegun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.6
    • /
    • pp.491-498
    • /
    • 2017
  • Objective: Bacterial abundance and community compositions have been examined in Asian dust events, clarifying their impacts on public health. This study aims to determine the bacterial community compositions and viable bacteria in Asian dust particles in the Asian dust or non-Asian dust event of March 2016. Methods: The dust samples were collected using the high volume air sampler or high volume cascade impactor, and bacterial 16S rRNA genes were amplified using PCR, followed by pyrosequencing. Bacterial diversity index, richness estimate and community composition in the particles were analyzed from the sequencing data using Mothur software. Results: The results showed that the diversity and richness during Asian dust events were higher than them in non-Asian dust events. The total bacterial community analysis showed that at the phylum Proteobacteria, Actinobacteria and Firmicutes were the most dominant of Asian dust events and non-Asian dust events. In addition, the bacterial colony counts were higher during Asian dust event, comparing with non-Asian dust event. Conclusions: This study showed that bacterial community and richness of Asian dust samples was more complex and higher than non-Asian dust samples in Gyeonggi-do, Korea, which could affect public health and environment. Thus, the continuous monitoring of Asian dust could be an alternative for managing airborne bacteria.