• Title/Summary/Keyword: duct thickness

검색결과 41건 처리시간 0.025초

닥트두께가 대향류 화염구조에 미치는 영향의 조사 (Investigation of Effects of Duct Thickness an Counterflow Flam Structure)

  • 박외철;고경찬
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.61-65
    • /
    • 2002
  • Nonpremixed counterflow flames at low strain rates, $ag=12s^{-1}$ and $12s^{-1}$, were numerically simulated to investigate the effects of the duct thickness on the flame structure in normal gravity. For small values of the duct thickness, the positions of the flame and stagnation point were highly sensitive to the duct thickness. When the duct thickness was greater than 6mm, however, the effects of the duct thickness on the flame structure were negligible. The computed temperature along the duct centerline agreed well with measurements.

덕트 종횡비가 회전덕트 내 압력강하에 미치는 영향 (Effect of Duct Aspect Ratios on Pressure Drop in a Rotating Two-Pass Duct)

  • 김경민;이동현;조형희
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.505-513
    • /
    • 2006
  • The pressure drop characteristics in a rotating two-pass duct with rib turbulators are investigated in the present study. Three ducts of different aspect ratios (W/H=0.5, 1.0 and 2.0) are employed with a fixed hydraulic diameter ($D_h$) of 26.7 mm. $90^{\circ}$-rib turbulators with $1.5mm{\times}1.5mm$ cross-section are attached on the leading and trailing surfaces. The pitch-to-rib height ratio (p/e) is 1.0. The distance between the tip of the divider and the outer wall of the duct is 1.0 W. The thickness of divider wall is 6.0 mm o. 0.225 $D_h$. The Reynolds number (Re) based on the hydraulic diameter is kept constant at 10,000 and the .elation number (Ro) is varied from 0.0 to 0.2. As duct aspect ratio increases, high friction factor ratios show in overall regions. The reason is that the rib height-to-duct height ratio (e/H) increases, but the divider wall thickness-to-duct width ($t_d/W$) decreases. The rotation of duct produces pressure drop discrepancy between the leading and trailing surfaces. However, the pressure drop discrepancy of the high duct aspect ratio (AR=2.0) is smaller than that of the low duct aspect ratio (AR=0.5) due to the decrement of duct hight (H).

곡관에서 laser유속계를 이용한 비정상유동 계측에 대한 연구 (A Study on Unsteady Flow measurement using Laser Doppler Velocimeter in Curved Duct)

  • 조병기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권4호
    • /
    • pp.81-89
    • /
    • 1996
  • In the present study, the unsteady in a square-selctional 180.deg. curved duct are experimentally investigated. The experimental study using air in a square-sectional 180.deg. curved duct is carried out to measure axial velocity distributions with data acquisition and processing system. In this system, Rotating Machinery Resolver(RMR) and PHASE Software are used to obtain the results of unsteady flows. In conclusion, the exact measurement of unsteady flow using LDV system depends upon uniformity of metreials, duct thickness, and scattered particles.

  • PDF

Numerical Study of Three-Dimensional Compressible Flow Structure Within an S-Duct for Aircraft Engine Inlet

  • Cho, Soo-Yong;Park, Byung-Kyu
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제1권1호
    • /
    • pp.36-47
    • /
    • 2000
  • Three-dimensional compressible turbulent flow fields within the passage of a diffusing S-duct have been simulated by solving the Navier-Stokes equations with SIMPLE scheme. The average inlet Mach number is 0.6 and the Reynolds number based on the inlet diameter is $1.76{\times}10^6$ The extended $k-{\varepsilon}$ turbulence model is applied to modeling the Reynolds stresses. Computed results of the flow in a circular diffusing S-duct provide an understanding of the flow structure within a typical engine inlet system. These are compared with experimental wall static-pressure, total-pressure fields, and secondary velocity profiles. Additionally, boundary layer thickness, skin friction values, and streamlines in the symmetric plane are presented. The computed results depict the interaction between the low energy flow by the flow separation and the high energy flow by the reversed duct curvature. The computed results obtained using the extended $k-{\varepsilon}$ turbulence model.

  • PDF

정상중력 및 무중력에서의 저변형율 대향류화염의 전산 (Computation of a Low Strain Rate Counterflow Flame in Normal and Zero Gravity)

  • Woe-Chul Park
    • 한국안전학회지
    • /
    • 제17권3호
    • /
    • pp.107-111
    • /
    • 2002
  • 닥트의 두께와 속도 경계조건이 정상중력 및 무중력 상태에서 화염구조에 미치는 영향을 조사하기 위해 81%의 질소와 19%의 메탄이 혼합된 가연성가스와 공기의 저변형율 (20 s-1) 대향류 화염을 수치법으로 모사하였다. 정상중력에서는 닥트의 두께와 속도 경계조건에 따라 화염의 위치가 이동함으로써 그 영향이 컸으나, 무중력에서는 그 영향을 무시할 수 있을 정도로 작은 것으로 나타났다. 화염구조의 차이는 부력으로 인한 것이고, 따라서 정상중력에서의 측정에서는 닥트 두께와 속도 경계조건의 영향을 고려해야 함을 알 수 있었다.

Buckling of insulated irregular transition flue gas ducts under axial loading

  • Ramadan, H.M.
    • Structural Engineering and Mechanics
    • /
    • 제43권4호
    • /
    • pp.449-458
    • /
    • 2012
  • Finite element buckling analysis of insulated transition flue ducts is carried out to determine the critical buckling load multipliers when subjected to axial compression for design process. Through this investigation, the results of numerical computations to examine the buckling strength for different possible duct shapes (cylinder, and circular-to-square) are presented. The load multipliers are determined through detailed buckling analysis taking into account the effects of geometrical construction and duct plate thickness which have great influence on the buckling load. Enhancement in the buckling capacity of such ducts by the addition of horizontal and vertical stiffeners is also investigated. Several models with varying dimensions and plate thicknesses are examined to obtain the linear buckling capacities against duct dimensions. The percentage improvement in the buckling capacity due to the addition of vertical stiffeners and horizontal Stiffeners is shown to be as high as three times for some cases. The study suggests that the best location of the horizontal stiffener is at 0.25 of duct depth from the bottom to achieve the maximum buckling capacity. A design equation estimating the buckling strength of geometrically perfect cylindrical-to-square shell is developed by using regression analysis accurately with approximately 4% errors.

Radiation-Laminar Free Convection in a Square Duct with Specular Reflection by Absorbing-Emitting Medium

  • Byun, Ki-Hong;Im, Moon-Hyuk
    • Journal of Mechanical Science and Technology
    • /
    • 제16권10호
    • /
    • pp.1346-1354
    • /
    • 2002
  • The purpose of this work is to study the effects of specularly reflecting wall under the combined radiative and laminar free convective heat transfer in an infinite square duct. An absorbing and emitting gray medium is enclosed by the opaque and diffusely emitting walls. The walls may reflect diffusely or specularly. Boussinesq approximation is used for the buoyancy term. The radiative heat transfer is evaluated using the direct discrete ordinates method. The parameters under considerations are Rayleigh number, conduction to radiation parameter, optical thickness, wall emissivity and reflection mode. The differences caused by the reflection mode on the stream line, and temperature distribution and wall heat fluxes are studied. Some differences are observed for the categories mentioned above if the order of the conduction to radiation parameter is less than order of 10$\^$-3/ fer the range of Rayleigh number studied. The differences at the side wall heat flux distributions are observed as long as the medium is optically thin. As the top wall emissivity decreases, the differences between these two modes are increased. As the optical thickness decreases at the fixed wall emissivity, the differences also increase. The difference of the streamlines or the temperature contours is not as distinct as the side wall heat flux distributions. The specular reflection may alter the fluid motion.

AIP면 유동측정 정확도 향상을 위한 가스터빈엔진 입구덕트 설계 연구 (Design Study of Engine Inlet Duct for Measurement Improvement of the Flow Properties on AIP)

  • 임주현;김성돈;김용련
    • 한국추진공학회지
    • /
    • 제21권3호
    • /
    • pp.49-55
    • /
    • 2017
  • 가스터빈엔진의 성능시험을 위한 엔진 입구덕트를 1D 기법으로 Sizing 하였으며, 압축기 입구유동측정면(AIP, Aerodynamic interface plane)에서 경계층 두께를 최소화하고, 코어부 마하수분포가 균일하도록 설계하였다. 노즈콘 형상은 Haack-series 모델을 적용하고, 덕트 안쪽과 바깥쪽 면적변화율이 동일하도록 입구덕트 채널 바깥반경($r_o$)를 결정하여 설계목적을 구현하고자 하였으며, 이러한 형상이 설계목표에 부합하는지 확인하기 위하여 CFD를 수행하였다. AIP면에서 정압력분포는 최대값과 최소값 차이가 0.16% 이었으며, 마하수분포에서 경계층은 덕트반경 길의 2% 이내로 설계목표를 만족하였다. 이때 균일유동 코어부는 채널높이의 95% 이상이었다. 또한 입구유동의 전온도를 측정하기 위한 키엘 전 온도레이크 위치는 온도 회복계수가 최대화 되도록 마하수가 0.1 이하 지역인 노즈콘 전방 100 mm 이내이어야 함을 확인하였다.

INLET S-DUCT 내부흐름의 전압력 편차에 대한 실험 연구 (Experimental study of total pressure distortion in inlet S-ducts)

  • 김무도;정상영;김요섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.541-546
    • /
    • 1987
  • An experimental study has been conducted to investigate the suction performance of a designed inlet. Total pressure distortion in the inlet S-duct was measured and the effect of lip thickness and throat area was analyzed. The volume flow rate of air into the turbojet engine was controlled to observe the effect of engine RPM to the total pressure distortion. The pressure data from 36 air tubes were obtained using scanivalve, pressure transducer, and visicoder system.

  • PDF

Evaluation of Tear Film Lipid Layer Thickness Measurements Obtained Using an Ocular Surface Interferometer in Nasolacrimal Duct Obstruction Patients

  • Lee, Sang Min;Chung, Sok Joong;Lew, Helen
    • Korean Journal of Ophthalmology
    • /
    • 제32권6호
    • /
    • pp.445-450
    • /
    • 2018
  • Purpose: To compare the tear film lipid layer thickness (LLT) between patients with incomplete nasolacrimal duct obstruction (NLDO) and normal controls and to analyze the changes in tear film LLT and blinking pattern after silicone tube intubation in NLDO patients. Methods: We reviewed the medical records of 68 eyes in 52 incomplete NLDO patients who underwent silicone tube intubation from January 2017 to July 2017. The LLT, blinking pattern, and Meibomian gland image were measured with the LipiView II ocular surface interferometer. The Meibomian gland drop-out ratio was measured using the polygon selection tool in the Image J program. Tear meniscus height, which is the other lacrimal indicator, was assessed with spectral-domain optical coherence tomography. Results: Tear meniscus height was significantly decreased after silicone tube intubation (p < 0.01). Preoperative minimum, maximum, and average LLT values were $62.4{\pm}24.0$, $86.7{\pm}17.9$, and $71.7{\pm}23.3nm$, respectively. Significant changes in the minimum, maximum, and average LLT ($74.8{\pm}23.6$, $98.8{\pm}11.0$, and $91.6{\pm}16.1nm$, respectively) were observed after silicone tube intubation (p < 0.001, p = 0.001, and p < 0.001). The partial blinking/total blinking ratio in 20 seconds and the Meibomian gland drop-out ratio showed no significant change after silicone tube intubation. Conclusions: Overall, the LLT was increased after silicone tube intubation. Silicone tube intubation may be helpful in maintaining LLT with a normalized of amount of tears.