• 제목/요약/키워드: dual-cure

검색결과 55건 처리시간 0.033초

The effects of different surface treatments on the shear bond strengths of two dual-cure resin cements to CAD/CAM restorative materials

  • Turker, Nurullah;Buyukkaplan, Ulviye Sebnem;Basar, Ebru Kaya;Ozarslan, Mehmet Mustafa
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.189-196
    • /
    • 2020
  • PURPOSE. The aim of the present study was to investigate the effects of surface treatments on the bond strengths between polymer-containing restorative materials and two dual-cure resin cements. MATERIALS AND METHODS. In the present study, rectangular samples prepared from Lava Ultimate (LU) and Vita Enamic (VE) blocks were used. The specimen surfaces were treated using CoJet sandblasting, 50 ㎛ Al2O3 sandblasting, % 9 HF (hydrofluoric) acid, ER,Cr:YSGG laser treatment, and Z-Prime. Dual-cure resin cements (TheraCem and 3M RelyX U 200) were applied on each specimen's treated surface. A micro-tensile device was used to evaluate shear bond strength. Statistical analysis was performed using the SAS 9.4v3. RESULTS. While the bond strength using TheraCem with LU or VE was not statistically significant (P=.164), the bond strength using U200 with VE was statistically significant (P=.006). In the TheraCem applied VE groups, Z-Prime and HF acid were statistically different from CoJet, Laser, and Sandblast groups. In comparison of TheraCem used LU group, there was a statistically significant difference between HF acid and other surface treatments. CONCLUSION. The bonding performance between the restorative materials and cements were material type-dependent and surface treatment had a large effect on the bond strength. Within the limitations of the study, the use of both U200 and TheraCem may be suggested if Z-prime was applied to intaglio surfaces of VE. The cementation of LU using TheraCem is suitable after HF acid conditioning of the restoration surfaces.

Effects of a relined fiberglass post with conventional and self-adhesive resin cement

  • Wilton Lima dos Santos Junior;Marina Rodrigues Santi;Rodrigo Barros Esteves Lins;Luis Roberto Marcondes Martins
    • Restorative Dentistry and Endodontics
    • /
    • 제49권2호
    • /
    • pp.18.1-18.13
    • /
    • 2024
  • Objectives: This study was conducted to evaluate the mechanical properties of relined and non-relined fiberglass posts when cemented to root canal dentin using a conventional dual-cure resin cement or a self-adhesive resin cement. Materials and Methods: Two types of resin cements were utilized: conventional and self-adhesive. Additionally, 2 cementation protocols were employed, involving relined and non-relined fiberglass posts. In total, 72 bovine incisors were cemented and subjected to push-out bond strength testing (n = 10) followed by failure mode analysis. The cross-sectional microhardness (n = 5) was assessed along the root canal, and interface analyses (n = 3) were conducted using scanning electron microscopy (SEM). Data from the push-out bond strength and cross-sectional microhardness tests were analyzed via 3-way analysis of variance and the Bonferroni post-hoc test (α= 0.05). Results: For non-relined fiberglass posts, conventional resin cement exhibited higher pushout bond strength than self-adhesive cement. Relined fiberglass posts yielded comparable results between the resin cements. Type II failure was the most common failure mode for both resin cements, regardless of cementation protocol. The use of relined fiberglass posts improved the cross-sectional microhardness values for both cements. SEM images revealed voids and bubbles in the incisors with non-relined fiberglass posts. Conclusions: Mechanical properties were impacted by the cementation protocol. Relined fiberglass posts presented the highest push-out bond strength and cross-sectional microhardness values, regardless of the resin cement used (conventional dual-cure or self-adhesive). Conversely, for non-relined fiberglass posts, the conventional dual-cure resin cement yielded superior results to the self-adhesive resin cement.

이원 중합 레진시멘트의 수분 흡착도와 수분 흡착에 따른 경도 변화 비교 연구 (A study on the water sorption and the effect of water sorption on micro-hardness of dual-cure resin cements)

  • 최수정;조진현;이청희
    • 구강회복응용과학지
    • /
    • 제30권2호
    • /
    • pp.138-144
    • /
    • 2014
  • 목적: 이 연구의 목적은 다양한 이원 중합 레진 시멘트의 수분 흡착도를 조사하고, 수분 흡착에 따른 미세 경도 변화를 비교해보는 것이다. 연구 재료 및 방법: 다섯 가지의 이원중합 레진시멘트를 선정하였다(Maxcem, Duo-link, Panavia F, Variolink II, Rely X Unicem). 각 그룹 당 10개씩, 총 50개의 시편을 제작하였다.각 그룹 당 5개의 시편들을 증류수에 7일 동안 보관 후 수분 흡착도를 평가하였다. 증류수에 보관한 시편과 보관하지 않은 시편들을 비교하여 결과를 얻었다. 결과: 1. 수분 흡착도에 있어서 Maxcem이 유의성 있게 가장 높았다. 2. 증류수에 보관하지 않았던 시편의 미세 경도는 Rely X Unicem의 유의성 있게 가장 높았다. 3. 증류수에 보관하였던 시편의 미세 경도는 Rely X Unicem이 유의성 있게 가장 높았다. 4. 수분 흡수에 따른 미세 경도의 변화에 있어서 Variolink II는차이가없는것으로나타났으나, Duo-link, Panavia F, 그리고 Rely X Unicem은 감소되었으며, Maxcem은 증가되었다. 결론: 임상적으로 레진시멘트 선택시 수분 흡착도가 작고, 미세 경도가 높은 재료를 선택하는 것이 추천된다.

Nanofiller as Crosslinker for Halogen-Containing Elastomers

  • Sahoo, N.G.;Kumar, E.Shiva;Das, C.K.;Panda, A.B.;Pramanik, P.
    • Macromolecular Research
    • /
    • 제11권6호
    • /
    • pp.506-510
    • /
    • 2003
  • A Zn ion-coated nanosilica filler has been developed and tested, in chlorosulfonated polyethylene (CSPE) and polychloroprene (CR), as a vulcanizing activator, cum was reinforcing filler. In this study, ZnO was replaced by the Zn ion-coated nanosilica filler with an aim of studying the dual role of this nanofiller in CSPE and CR. In the case of CSPE vulcanizates, the presence of MgO deteriorated the state and rate of cure when the Zn ion-coated nanosilica filler was used, but in the case of CR it improved the state of cure and enhanced the modulus and tensile strength. The Zn ion-coated filler proved to be a better reinforcing-cum-curing agent than was externally added ZnO and NA-22 also proved to be a better curative in the presence of the Zn ion-coated nanosilica filler for both CSPE and CR.

도재인레이 하방에서 광중합형 복합레진과 이중중합형 복합레진시멘트의 미세경도와 중합률에 관한 연구 (THE MICROHARDNESS AND THE DEGREE OF CONVERSION OF LIGHT CURED COMPOSITE RESIN AND DUAL CURED RESIN CEMENTS UNDER PORCELAIN INLAY)

  • 김승수;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.17-40
    • /
    • 2000
  • Resin cements are used for cementing indirect esthetic restorations such as resin or porcelain inlays. Because of its limitations in curing of purely light cured resin cements due to attenuation of the curing light by intervening materials, dual cured resin cements are recommended for cementing restorations. The physical properties of resin cements are greatly influenced by the extent to which a resin cures and the degree of cure is an important factor in the success of the inlay. The purpose of this study was to evaluate the influence of porcelain thickness and exposure time on the polymerization of resin cements by measuring the microhardness and the degree of conversion, to investigate the nature of the correlation between two methods mentioned above, and to determine the exposure time needed to harden resin cements through various thickness of porcelain. The degree of resin cure was evaluated by the measurements of microhardness [Vickers Hardness Number(VHN)] and degree of conversion(DC), as determined by Fourier Transform Infrared Spectroscopy(FTIR) on one light cured composite resin [Z-100(Z)] and three dual cured resin cements [Duo cement(D), 3M Resin cement(R), and Dual cement(DA)] which were cured under porcelain discs thickness of 0mm, 1mm, 2mm, 3mm with light exposure time of 40sec, 80sec, 120sec, and regression analysis was performed to determine the correlation between VHN and DC. In addition, to determine the exposure time needed to harden resin cements under various thickness of porcelain discs, the changes of the intensity of light attenuated by 1mm, 2mm, and 3mm thickness of porcelain discs were measured using the curing radiometer. The results were obtained as follows ; 1. The values of microhardness and the degree of conversion of resin cements without intervening porcelain discs were 31~109VHN and 51~63%, respectively. In the microhardness Z was the highest, followed by R, D, DA. In the degree of conversion, D and DA was significantly greater than Z and R(p<0.05). 2. The microhardness and the degree of conversion of the resin cements decreased with increasing thickness of porcelain discs, and increased with increasing exposure time, D and R showed great variation with inlay thickness and exposure time, whereas, DA showed a little variation. 3. The intensity of light through 1mm, 2mm, and 3mm porcelain inlays decreased by 0.43, 0.25, and 0.14 times compared to direct illumination, and the respective needed exposure times are 53 sec, 70 sec, and 93 sec. In D and R, 40 sec of light irradiation through 2mm porcelain disc and 80 sec of light irradiation through 3mm porcelain disc were not enough to complete curing. 4. The microhardness and the degree of conversion of the resin cements showed a positive correlationship(R=0.791~0.965) in the order of R, D, Z, DA. As the thickness of porcelain discs increased, the decreasing pattern of microhardness was different from that of the degree of conversion, however.

  • PDF

치과용 레진 시멘트의 중합 수축률 특성에 관한 연구 (In vitro study of Polymerization shrinkage-strain kinetics of dental resin cements)

  • 김태훈;양재호;이재봉;한중석;김성훈
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.55-60
    • /
    • 2010
  • 연구 목적: 치과용 레진시멘트의 중합 수축은 수복물이 치아에 정확하게 합착되는 것을 방해하고, 내부 응력의 원인이 되어 치아에 여러 문제점을 일으킬 수 있다. 이러한 임상적인 문제점을 줄이기 위해서 사용하는 치과용 레진시멘트의 중합 수축률에 대해 아는 것이 중요하다. 본 연구에서는 상업적으로 이용되고 있는 몇 가지 레진시멘트의 시간에 따른 중합 수축률을 측정, 서로 비교하고자 하였다. 연구 재료 및 방법: 3종류의 자가 중합형 레진시멘트(Fujicem, Superbond, M bond)와 3종류의 이원 중합형 레진시멘트(Maxcem, Panavia F, Variolink II) 별로 각각 5개의 시편을 이용하였다. 각 재료의 중합 수축률은 Bonded disk method를 이용하여 측정하였다. 안쪽 직경 16 mm, 두께 1 mm 의 동으로 제작된 링을 유리판 ($74\;mm\;{\times}\;25\;mm\;{\times}\;3\;mm$) 위의 중앙에 위치시켜 부착하고, 그 유리판 중앙에 실험 재료를 구 형태로 만들어 올리고, 다른 유리판으로 눌러서 원판 형태 (직경 8 mm, 두께 1 mm)의 시편을 제작하였다. 시편의 중합 수축률은 재료가 중합이 시작된 후 120분동안, $23^{\circ}C$에서 측정하였다. 시간에 따른 수축량에 대한 kinetics curve를얻고, 각 실험 재료의 수축률의 평균값 (%)과 표준편차를 구한 뒤, one-way ANOVA 및 Scheffe post hoc test를 유의수준 0.05 에서 처리하여 그 결과 값을 비교하였다. 결과: 1. 실험에 사용된 Fujicem, Maxcem, M bond, Panavia F, Superbond, Variolink II 은 중합이 시작 된 120 분 후의 중합 수축률이 각각 3.72%, 4.19%, 4.13%, 2.44%, 7.57%, 2.90%의 값을 보였다. 2. Panavia F가 중합 수축률이 가장 작았고, Superbond가 중합 수축률이 가장 컸다 (P<.05). 3. Maxcem 과 M Bond 간에는 유의한 차이가 없었다 (P>.05). 4. 6종류의 레진 시멘트에서 90% 이상의 대부분의 수축은 중합이 개시된 30분 내에 거의 일어났다. 결론: 자가 중합형 레진시멘트의 혼합 후 나타나는 중합 수축이 이원 중합형 레진시멘트보다 천천히 일어나지만, 혼합 120분 뒤의 중합 수축은 이원 중합형 레진 시멘트 보다 유의할 정도로 높았다. 치과용 레진시멘트의 중합 수축은 혼합한 후 30 분내에 대부분 일어난다.

Microshear bond strength of dual-cure resin cement in zirconia after different cleaning techniques: an in vitro study

  • Atoche-Socola, Katherine Joselyn;Arriola-Guillen, Luis Ernesto;Lopez-Flores, Ana Isabel;Garcia, Isadora Martini;Huertas-Mogollon, Gustavo;Collares, Fabricio Mezzomo;Leitune, Vicente Castelo Branco
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권4호
    • /
    • pp.237-245
    • /
    • 2021
  • PURPOSE. This study aimed to compare the microshear bond strength (µSBS) of dual-cure resin cement in CAD-CAM zirconia after different cleaning techniques. MATERIALS AND METHODS. Fifty discs of zirconia-based ceramic from Ivoclar Vivadent were embedded in acrylic resin. The discs were divided into five groups according to the cleaning methods used: Group 1: drying with spraying + sandblasting with Al2O3; Group 2: washed with water and dried with spraying + sandblasting with Al2O3;Group 3: washed with distilled water and dried with spraying + sandblasting with Al2O3 + zirconium oxide (Ivoclean); Group 4: washed with distilled water and dried with spraying + sandblasting with Al2O3 + potassium hydroxide (Zirclean); and Group 5: washed with distilled water and dried with spraying + sandblasting with Al2O3 + 1% NaClO. All of the groups were contaminated with artificial saliva for 1 minute and then cleaned. Statistical analyses were performed using ANOVA and Tukey's tests. RESULTS. There were statistically significant differences among all groups for µSBS (P < .05). The group treated with zirconium oxide (Group 3) showed the highest µSBS (18.75 ± 0.23 MPa). CONCLUSION. When applied to zirconia, the cleaning methods affected the bonding with resin cement differently.

두께에 따른 이중 중합형 복합레진의 중합 (Polymerization of dual cured composites by different thickness)

  • 김윤주;진명욱;김성교;권태엽;김영경
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.169-176
    • /
    • 2008
  • 본 연구는 이중 중합형 복합레진에서 재료의 두께, 충전방법 및 중합방법에 따른 중합도를 미세경도 시험을 이용하여 측정하고자 하였다. 이중 중합형 복합레진으로는 MultiCore Flow (Ivovlar Vivadent AG, Schaan, Liechtenstein)와 Bis-Core (Bisco Inc., Schaumburg IL, USA)를 사용하였다. 시편의 제작은 각각 두께가 2(단일충전), 4 (단일충전), 6 (단일충전과 적층충전), 8 (단일충전과 적층충전) ㎜의 Teflon mold에 재료를 주입한 다음 할로겐 광중합기 (Optilux 501, Kerr, Danbury, USA)를 사용하여 광중합하거나 암실에서 30분 동안 기다린 후(자가 중합) Teflon mold에서 제거하였다. 제거한 시편은 $37{\circ}C$ 증류수에 24시간 동안 보관한 후 각 시편의 윗면과 아랫면을 2000번 연마제와 PoGo system (Dentsply, Konstanz, Germany)을 이용하여 마무리하였다. Digital microhardness tester (FM-7, Future-Tech Corp., Tokyo, Japan)를 이용하여 경도값(Knoop hardness number)을 측정하였으며 윗면의 경도값/아랫면의 경도값을 이용하여 경도비를 계산하였다. 계측치는 one-way ANOVA로 통계 분석 후 사후검정은 Scheffe 다중비교법을 이용하였다. 이중 중합형 복합레진의 중합도에 대한 두께의 영향을 보면 재료에 따라 다른 결과를 보였다. 2, 4, 6 mm 군에서는 MulriCore Flow와 Bis-Core 모두 두께에 의한 영향을 받지 않았지만 8 mm 군에서는 MultiCore Flow의 아랫면에서 다른 두께의 군보다 낮은 경도값을 보였다. 충전방법에 따른 중합도의 차이를 보면, 재료의 두께나 재료에 따라 다른 결과를 보였다. 6 mm 군에서는 단일충전군과 적층충전군 사이에 차이를 보이지 않았으나, 8 mm 군에서는 Bis-Core에서는 차이가 없는 반면 MultiCore Flow에서는 단일충전한 군이 적층중전한 군보다 낮은 경도비를 보였다. 중합방법에 따른 중합도의 차이를 보면, 재료에 따라 다른 결과를 보였다. Bis-Core의 경우에는 윗면과 아랫면 모두에서 이중 중합 시킨 군이 자가 중합 시킨 군보다 높은 경도값을 보였다. 그러나 MultiCore Flow의 경우, 윗면에서는 이중중합 시킨 군이 더 높은 경도값을 보였지만 아랫면에서는 더 낮은 값을 보였다. 따라서 본 연구의 결과에 따르면 코어용 이중 중합형 복합레진을 깊은 와동에 충전할 경우 적층충전이 추천되며, 또한 광중합을 해 줌으로써 더 좋은 물리적 성질을 기대할 수 있을 것으로 사료된다.

두께에 따른 이중 중합형 복합레진의 중합 (Polymerization of dual cured composites by different thickness)

  • 김윤주;진명욱;김성교;권태엽;김영경
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.169-176
    • /
    • 2008
  • 본 연구는 이중 중합형 복합레진에서 재료의 두께, 충전방법 및 중합방법에 따른 중합도를 미세경도 시험을 이용하여 측정하고자 하였다. 이중 중합형 복합레진으로는 MultiCore Flow (Ivovlar Vivadent AG, Schaan, Liechtenstein)와 Bis-Core (Bisco Inc. Schaumburg IL, USA)를 사용하였다. 시편의 제작은 각각 두께가 2 (단일충전). 4 (단일충전), 6 (단일충전과 적층충전), 8 (단일충전과 적층충전) mm의 Teflon mold에 재료를 주입한 다음 할로겐 광중합기 (Optilux 501 Kerr, Danbury, USA)를 사용하여 광중합하거나 암실에서 30분 동안 기다린 후(자가 중합) Teflon mold에서 제거하였다. 제거한 시편은 $37^{\circ}C$ 증류수에 24시간 동안 보관한 후 각 시편의 윗면과 아랫면을 2000번 연마제와 PoGo system (Dentsply, Konstanz, Germany)을 이용하여 마무리하였다. Digital microhardness tester (FM-7, Future-Tech Corp., Tokyo, Japan)를 이용하여 경도값(Knoop hardness number)을 측정하였으며 윗면의 경도값/아랫면의 경도값을 이용하여 경도비를 계산하였다. 계측치는 one-way ANOVA로 통계 분석 후 사후검정은 Scheffe 다중비교법을 이용하였다. 이중 중합형 복합레진의 중합도에 대한 두께의 영향을 보면 재료에 따라 다른 결과를 보였다. 2, 4, 6 mm군에서는 MultiCore Flow와 Bis-Core 모두 두께에 의한 영향을 받지 않았지만 8 mm 군에서는 MultiCore Flow의 아랫면에서 다른 두께의 군보다 낮은 경도값을 보였다. 충전방법에 따른 중합도의 차이를 보면 재료의 두께나 재료에 따라 다른 결과를 보였다. 6 mm 군에서는 단일충전군과 적층충전군 사이에 차이를 보이지 않았으나, 8 mm 군에서는 Bis-Core에서는 차이가 없는 반면 MultiCore Flow에서는 단일충전한 군이 적층충전한 군보다 낮은 경도비를 보였다. 중합방법에 따른 중합도의 차이를 보면, 재료에 따라 다른 결과를 보였다. Bis-Core의 경우에는 윗면과 아랫면 모두에서 이중 중합 시킨군이 자가 중합시킨 군보다 높은 경도값을 보였다. 그러나 MultiCore Flow의 경우, 윗면에서는 이중중합 시킨 군이 더 높은 경도값을 보였지만 아랫면에서는 더 낮은 값을 보였다. 따라서 본 연구의 결과에 따르면 코어용 이중 중합형 복합레진을 깊은 와동에 충전할 경우 적층충전이 추천되며, 또한 광중합을 해줌으로써 더 좋은 물리적 성질을 기대할 수 있을 것으로 사료된다.

  • PDF

중간레진의 친수성이 상아질 접착에 미치는 영향 (EFFECT OF INTERMEDIATE RESIN HYDROPHILICITY ON BOND STRENGTH OF SINGLE STEP ADHESIVE)

  • 김용성;박상혁;최기운;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제32권5호
    • /
    • pp.445-458
    • /
    • 2007
  • 단일과정 접착제를 이용함에 있어 복합레진과의 부적합성을 개선하고자 중간레진이 결합에 영향을 미칠 것으로 사료된다. Experimental single step system (Bisco Ltd., Schaumburg, IL)을 대조군으로 하고 6종의 중간레진을 접착제의 중합여부, 복합레진의 광중합-자가중합 여부로 분류하였다. 상아질에 대한 광중합 또는 자가중합형 복합레진의 결합강도를 측정하고 접착계면에 대한 투과전자현미경 관찰하여 다음과 같은 결론을 얻었다. 1. 중간레진의 적용은 광중합형 복합레진의 결합강도를 증가시키지 않았다. 2. 자가중합형 복합레진의 결합강도는 중간레진을 적용할 경우 증가하였다. 3. 중간레진의 적용 전 접착제의 중합여부는 결합강도의 변화에 영향을 미치지 않았다. 4. 중간레진이 친수성일 때 소수성 중간레진을 적용할 때 보다 높은 결합강도를 나타냈으나 통계적 유의차는 없었다. 광중합형 복합레진의 수복 시 단일과정 접착제를 사용하는 것은 초기 결합강도에 영향을 미치지 않으며, 자가중합형 복합레진을 단일과정 접착제와 사용할 때는 접착층의 투과도를 감소시키는 소수성의 중간레진을 적용하여 부적합성을 해소할 수 있을 것이다.