• Title/Summary/Keyword: dual thickness

Search Result 235, Processing Time 0.028 seconds

Efficacy of dual progesterone administration (intramuscular and vaginal) for luteal support in fresh day 3 or day 4 embryo transfer cycles

  • Nho, Eun Jee;Hong, Yeon Hee;Park, Ju Hee;Kim, Seul Ki;Lee, Jung Ryeol;Jee, Byung Chul;Kim, Seok Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.47 no.3
    • /
    • pp.227-232
    • /
    • 2020
  • Objective: The aim of this study was to compare in vitro fertilization outcomes between fresh day 3 or day 4 embryo transfer cycles with dual progesterone (P) administration (intramuscular and vaginal) and cycles with single intramuscular P administration for luteal support. Methods: We selected 124 cycles from 100 women (under age 40 years) who underwent oocyte pick-up (number of trials ≤ 3, 4-14 oocytes obtained) and transfer of two or three day 3 or day 4 embryos at two infertility centers from January 2014 to June 2019. Dual P (intramuscular P [50 mg] daily+vaginal P) was used in 52 cycles and a single intramuscular administration of P (50 mg daily) was used in 72 cycles. Results: Women's age, infertility factors, number of oocytes retrieved, number of transferred embryos, and mean embryo score were similar between the dual P group and the single P group. Although the number of trial cycles was significantly higher (1.9 vs. 1.5), and the mean endometrial thickness on the trigger day (10.0 mm vs. 11.0 mm) was significantly lower in the dual P group, the implantation rate, clinical pregnancy rate, ongoing pregnancy rate, and miscarriage rate for both day 3 and day 4 transfers were similar between the two groups. Conclusion: In fresh day 3 or day 4 embryo transfer cycles, dual P administration did not demonstrate any clinical advantages. Intramuscular P alone appears to be sufficient for luteal support.

Dual Stage Actuator System for High Density Magnetic Disk Drives Using a Rotary-type Electrostatic Microatuator (회전구동 정전형 마이크로 액추에이터를 이용한 고트랙밀도 HDD용 이단 구동 시스템)

  • Jung Sunghwan;Choi Jae-Joon;Park Jihwang;Lee Chang-Ho;Kim Cheol-Soon;Min Dong-Ki;Kim Young-Hoon;Lee Seung-Hi;Jeon Jong Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.10 s.175
    • /
    • pp.174-185
    • /
    • 2005
  • This paper presents the design, fabrication, and testing results of a dual stage actuator system for a fine positioning of magnetic heads in magnetic disk drives. A novel rotary microactuator which is electrostatically driven and utilized as a secondary actuator was designed. The stator and rotor electrodes in the microactuator was revised to have the optimal shapes and hence produces much higher rotational torque compared with the conventional comb-shape electrodes. The microactuators were successfully fabricated using SoG(silicon on glass) processing technology, which is known as being cost-effective. The fabricated microactuator has the structural thickness of $45{\mu}m$ with the gap width of approximately $3{\mu}m$. The dynamic characteristic of microactuator/slider assembly was investigated, and its natural frequency and DC gain were measured to be 3.4kHz and 32nm/V, respectively. The microactuator/slider assembly was integrated into a HDD model V10 of Samsung Electronics Co. and a dual servo algorithm was tested to explore the tracking performance of dual stage actuator system where the LDV signals instead of magnetic head signals were used. Experimental results indicate that this system achieves the tracking accuracy of 30nm. This value corresponds to a track density of 85,000 track per inch(TPI), which is about 3 times greater than that of current hard disk drives.

Feasibility of Single-Shot Dual-Energy X-ray Imaging Technique for Printed-Circuit Board Inspection (인쇄회로기판 검사를 위한 단일조사 이중에너지 엑스선 영상기법의 유용성에 관한 연구)

  • Kim, Seung Ho;Kim, Dong Woon;Kim, Daecheon;Kim, Junwoo;Park, Ji Woong;Park, Eunpyeong;Kim, Jinwoo;Kim, Ho Kyung
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.137-141
    • /
    • 2015
  • A single-shot dual-energy x-ray imaging technique has been developed using a sandwich detector by stacking two detectors, in which the front and rear detectors respectively produce relatively lower and higher x-ray energy images. Each detector layer is composed of a phosphor screen coupled with a photodiode array. The front detector layer employs a thinner phosphor screen, whereas the rear detector layer employs a thicker phosphor screen considering the quantum efficiency for x-ray photons with higher energies. We have applied the proposed method into the inspection of printed circuit boards, and obtained dual-energy images with background clutter suppressed. In addition, the single-shot dual-energy method provides sharper-edge images than the conventional radiography because of the unsharp masking effect resulting from the use of different thickness phosphors between the two detector layers. It is promising to use the single-shot dual-energy x-ray imaging for high-resolution nondestructive testing. For the reliable use of the developed method, however, more quantitative analysis is further required in comparisons with the conventional method for various types of printed circuit boards.

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.

A Study on Time-Dependent Optimal Heater Control for Thermoforming Using Response Surface Method (열성형 과정에서 반응면 기법을 이용한 히터의 비정상 최적제어에 관한 연구)

  • Li, Zhen-Zhe;Heo, Kwang-Su;Seol, Seoung-Yun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2528-2533
    • /
    • 2007
  • Thermoforming is one of the most versatile and economical processes available for the manufacturing polymer products. The drawback of thermoforming is difficult to get uniform thickness of final products. For the distribution of thickness strongly depends on the temperature distribution of sheet, the adjustment of heater power is very important In this paper, an optimization study for getting uniform temperature distribution was carried out using dual optimization steps. At first, the steady state optimal distribution of heater power is searched by numerical optimization to get uniform temperature of sheet surface. In the second step, time-dependent optimal heater inputs have been found out to decrease the temperature difference through the direction of thickness using Rseponse Surface Method and D-optimal method. The optimization results show that the time-dependent optimal heater power distribution gives acceptable uniform sheet temperature in the field of forming temperature..

  • PDF

The Effect of Dielectric Thickness and Barrier Rib Height on Addressing Time of Coplanar AC PDP (AC PDP의 유전체 두께와 격벽 높이에 따른 Addressing Time)

  • 신중홍;박정후
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1065-1069
    • /
    • 2002
  • The addressing time should be reduced by modifying cell structure and/or driving method in order to replace the dual scan system by single scan and increase the luminance in large ac plasma display panel(PDP). In this paper, the effects of the addressing time was decreased with decreasing thickness of dielectric layer on the front glass and thickness of white dielectric layer on the rear glass. the decreasing rate were 160ns/10$\mu\textrm{m}$ and 270ns/10$\mu\textrm{m}$, respectively Also in case of decreasing the height of barrier rib, addressing time was decreased at the rate of Sons/10$\mu\textrm{m}$.

Time-dependent Optimal Heater Control in Thermoforming Preheating Using Dual Optimization Steps

  • Li, Zhen-Zhe;Heo, Kwang-Su;Seol, Seoung-Yun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.51-56
    • /
    • 2008
  • Thermoforming is one of the most versatile and economical processes available for shaping polymer products, but obtaining a uniform thickness of the final product using this method is difficult. Heater power adjustment is very important because the thickness distribution depends strongly on the distribution of the sheet temperature. In this paper, the steady-state optimum distribution of heater power is first ascertained by a numerical optimization to obtain a uniform sheet temperature. The time-dependent optimal heater input is then determined to decrease the temperature difference through the direction of the thickness using the response surface method and the D-optimal method. The optimal results show that the time-dependent optimum heater power distribution gives an acceptable uniform sheet temperature in the forming temperature range by the end of the heating process.

Biphasic Release Characteristics of Dual Drug-loaded Alginate Beads

  • Lee, Beom-Jin;Cui, Jing-Hao;Kim, Tae-Wan;Heo, Min-Young;Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • v.21 no.6
    • /
    • pp.645-650
    • /
    • 1998
  • The dual drug-loaded alginate beads simultaneously containing drug in inner and outer layers were prepared by dropping plain (single-layered) alginate beads into $CaCl_2$ solution. The release characteristics were evaluated in simulated gastric fluid for 2 h followed by intestinal fluids thereafter for 12 h. The surface morphology and cross section of dual drug-loaded alginate beads was also investigated using scanning electron microscope (SEM). The poorlv water-soluble ibuprofen was chosen as a model drug. The surface of single-layered and dual drug-loaded alginate beads showed very crude and roughness, showing aggregated particles, surface cracks and rough crystals. The thickness of dual drug-loaded alginate beads surrounded by outer layer was ranged from about 57 to 329mcm. The distinct chasm between inner and outer layers was also observed. In case of single-layered alginate bead, the drug was not released in gastric fluid but was largely released in intestinal fluid. However, the release rate decreased as the reinforcing $Eudragit^{\circledR}$ polymer contents increased. When the plasticizers were added into polymer, the release rate largely decreased. The release rate of dual drug-loaded alginate beads was stable in gastric fluid for 2 h but largely increased when switched in intestinal fluid. The drug linearly released for 4 h followed by another linear release thereafter, showing a distinct biphasic release characteristics. There was a difference in the release profiles between single-layered and dual drug-loaded alginate beads due to their structural shape. However, this biphasic release profiles were modified by varying formulation compositions of inner and outer layer of alginate beads. The release rate of dual drug-loaded alginate beads slightly decreased when the outer layer was reinforced with $Eudragit^{\circledR}$ RS1OO polymers. In case of dual drug-loaded alginate beads with polymer-reinforced outer layer only, the initial amount of druc released was low but the initial release rate (slope) was higher due to more swellable inner cores when compared to polymer-reinforced inner cores. The current dual drug-loaded alginate beads may be used to deliver the drugs in a time dependent manner.

  • PDF

A Case of Pilomatrixoma after Split Thickness Skin Graft (식피술 후 발생한 모기질종 1례)

  • Choi, Jae Hoon;Park, Sung Gyu;Lee, Jin Hyo
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.753-756
    • /
    • 2006
  • Purpose: Pilomatrixoma is a benign, usually asymptomatic tumor. It presents clinically as a solitary superficial subcutaneous nodule measuring between 0.5 cm and 5 cm in diameter on the head or upper extremeties and has not been reported after skin graft. The objective of this article is to report our experience in treating pilomatrixoma which occurred after split thickness skin graft on the lower extremity. Methods: A 56-year-old female was treated in August 2005 with a $0.5{\times}0.5cm$ firm subcutaneous nodule at recipient site of split thickness skin graft on the left medial thigh. The tumor was successfully removed by complete excision and histologic examination was followed. Results: The diagnosis was pilomatrixoma which was characterized by a dual population of proliferating basophilic cells and diagnostic shadow cells. Conclusion: The tumor was successfully treated by complete resection. The authors report this very rare case of pilomatrixoma which occurred at recipient site of split thickness skin graft.

The reliability of dual rehabilitative ultrasound imaging measurements for muscle co-activation

  • Hahn, Joohee;Ha, Hyun-Geun;Lee, Hwang-Jae;Lim, Seungyeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.3
    • /
    • pp.152-157
    • /
    • 2017
  • Objective: The aim of this study was to determine the intra-rater and inter-rater reliability of the dual rehabilitative ultrasound imaging (D-RUSI) when simultaneously measuring muscle thickness changes at rest and during co-contraction of the biceps brachii (BB) and triceps brachii (TB). Design: Cross-sectional study. Methods: This study included 36 healthy participants (23 men, 13 women). The participants sat on a chair in a comfortable position with a cushion placed under their elbow to maintain a 90-degree elbow flexion angle. The muscle thickness of the biceps brachii and triceps brachii was measured twice using the D-RUSI by two examiners during resting and co-contraction states. One week later, the same procedure was performed once again. Results: The intra-class correlation coefficients (ICCs) for intra-rater reliability ranged from 0.887 to 0.989 and the confidence interval was within an acceptable range of 0.778 to 0.994. The standard error of measurement (SEM) values ranged from 0.303 to 0.866 and the minimal detectable change (MDC) values ranged from 0.84 to 2.40. The ICCs for inter-rater reliability ranged from 0.758 to 0.925. The SEM values ranged from 0.702 to 1.486 and the MDC values ranged from 1.95 to 4.12. Conclusions: The use of the D-RUSI of the BB muscle had a very good intra-rater reliability and very good inter-rater reliability at the resting state, and a, good inter-rater reliability at the co-activation state. ICC values showed very good intra-reliability and inter-reliability for the TB muscle. the D-RUSI is a useful tool for simultaneously measuring the thickness of two muscles when the BB is an agonist and the TB is an antagonist during co-activation of the upper arm.