• Title/Summary/Keyword: dual thickness

Search Result 236, Processing Time 0.026 seconds

Simultaneous Periareolar Augmentation Mastopexy: Dual Plane Versus Subfascial Plane (동시 유륜절개 유방하수교정술 및 확대술: 이중평면 대 근막밑평면)

  • Sim, Hyung Bo;Yoon, Sang Yub
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose: The major drawback of submuscular augmentation of the ptotic breast is a "double-bubble" deformity. If a traditional mastopexy is added to correct the ptosis, there would be additional scars. This article describes simultaneous periareolar mastopexy with dual plane or subfascial breast augmentations. Methods: A series of 81 patients with grade I or II ptosis underwent the procedure from 1999 to 2005. Out of these, dual plane augmentation was done in 71 cases and subfascial plane in 10. After periareolar skin excision, an incision is made perpendicularly down to the fascia of pectoralis. At the lower pole, all breast implants are inserted into the subfascial plane. In case of upper pole thickness of above 20 mm, we inserted the implant into the subfascial plane, whereas below 20 mm, we inserted that into the submuscular plane. Results: No major complications were noted and patients' satisfactory score was high. This technique avoids the "double-bubble" deformity and leaves a minimal periareolar scar. Conclusion: Simultaneous periareolar mastopexy/breast augmentation is useful for correction of the ptotic breast, increasing the volume of breast and providing the natural breast shape with minimal scars. We consider that subfascial plane augmentation with periareolar mastopexy to be an alternative for cases with breast upper pole thickness of at least above 20 mm.

Emission Characteristics of Dual Emission Tandem OLED with Charge Generation Layer MoOx and Cathode Al Thickness (전하생성층 MoOx와 음극 Al의 두께에 따른 양면발광 적층 OLED의 발광 특성)

  • Kim, Ji-Hyun;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.3
    • /
    • pp.316-321
    • /
    • 2016
  • To study emission characteristics for dual-emission tandem organic light emitting display (OLED), we fabricated blue fluorescent OLED according to thickness variation of $MoO_x$ as charge generation layer and Al as cathode. The bottom emission characteristics of OLED with $MoO_x$ 2, 3, 5 nm thickness showed threshold voltage of 9, 7, 9 V, maximum current emission efficiency of 19.32, 23.18, 15.44 cd/A and luminance of $1,000cd/m^2$ at applied voltage of 17.6, 13.2, 16.5 V, respectively. The top emission characteristics of OLED with $MoO_x$ 2, 3, 5 nm thickness indicated threshold voltage of 13, 10, 13 V, maximum current emission efficiency of 0.17, 0.23, 0.16 cd/A and luminance of $50cd/m^2$ at applied voltage of 22.6, 16.5, 20.1 V, respectively. In case of thicker or thinner than $MoO_x$ of 3 nm, the emission characteristics were decreased because of mismatching of electron and hole in emission layer. The bottom emission characteristics of OLED with Al 15, 20, 25 nm thickness showed threshold voltage of 8, 8, 7 V, maximum current emission efficiency of 18.42, 22.98, 23.18 cd/A and luminance of $1000cd/m^2$ at applied voltage of 16.2, 13.9, 13.2 V, respectively. The reduction of threshold voltage and increase of maximum current emission efficiency are caused by the increase of current injection according to increase of Al cathode thickness. The top emission characteristics of OLED with Al 15, 20, 25 nm thickness indicated threshold voltage of 7, 7, 8 V, maximum emission luminance of 371, 211, $170cd/m^2$, respectively. The top emission OLED of Al cathode with 15 nm thickness showed maximum luminance and it decreased at thickness of 20 nm. These phenomena are caused by the decrease of intensity of emitted light by reduction of optical transmittance according to increase of Al cathode thickness.

Degree of conversion of two dual-cured resin cements light-irradiated through zirconia ceramic disks

  • Kim, Min-Jeong;Kim, Kyo-Han;Kim, Young-Kyung;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.464-470
    • /
    • 2013
  • PURPOSE. The aim of this Fourier transform infrared (FTIR) spectroscopic study was to measure the degree of conversion (DC) of dual-cured resin cements light-irradiated through zirconia ceramic disks with different thicknesses using various light-curing methods. MATERIALS AND METHODS. Zirconia ceramic disks (KT12) with three different thicknesses (1.0, 2.0, and 4.0 mm) were prepared. The light transmittance of the disks was measured using ultraviolet visible near-infrared spectroscopy. Four different light-curing protocols were used by combining two curing light modes (Elipar TriLight (standard mode) and bluephase G2 (high power mode)) with light-exposure times of 40 and 120 seconds. The DCs of the two dual-cured resin cements (Duo-Link and Panavia F2.0) light-irradiated through the disks was analyzed at three time intervals (3, 7, and 10 minutes) by FTIR spectroscopy. The data was analyzed using repeated measures ANOVA (${\alpha}$=.05).Two-way ANOVA and Tukey post hoc test were used to analyze the 10 minute DC results. RESULTS. The 1.0 mm thick disk exhibited low light transmittance (<25%), and the transmittance decreased considerably with increasing disk thickness. All groups exhibited significantly higher 10 minute DC values than the 3 or 7 minute values (P<.05), but some exceptions were observed in Duo-Link. Two-way ANOVA revealed that the influence of the zirconia disk thickness on the 10 minute DC was dependent on the light-curing methods (P<.001). This finding was still valid even at 4.0 mm thickness, where substantial light attenuation took place. CONCLUSION. The curing of the dual-cured resin cements was affected significantly by the light-curing technique, even though the additional chemical polymerization mechanism worked effectively.

A STUDY ON THE VOND STRENGTH OF PORCELAIN LAMINATE AND COMPOSITE RESIN CEMENTS (라미네이트 도재와 복합레진 시멘트의 결합강도에 관한 연구)

  • Kim, Sung-Il;Lim, Ho-Nam;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.91-109
    • /
    • 1991
  • The purpose of this study were to comfirm the effects of the thickness and kinds of porcelain, etchants, illumination time, elapsed time for the measurement, and chemical cure component to the bond strength of porcelain laminate and composite resin cement, and to compare the effects between the light cured resin and the dual cured resins. The etched porcelain surface, the sectioned surface crossing porcelain and resin after bonding, and the debonded surfaces were observed by the SEM. One product of laminate porcelain powder, one light cured resin and two dual cured resins were selected. Each resin cements are lightened through the thin porcelain disc which was cut from cylindrical porcelain specimen by the diamond saw, and by the light through the porcelain disc they were bonded. Changes of thickness and kinds of porcelain, etchants, illumination time, and the elapsed time for the measurement were considered as variables for the bond strength. And the bond strength of porcelain and dual cured resins under the conditions of autopolymerization or the removal of chemical cure component were measured and compared. Bond strength were measured by shear stress. The etched surface, the cross-sectioned surface, and the debonded surface of porcelain or resin were observed by SEM. On the summary of this study, the following conclusions can be stated; 1. Bond strength of light cured resin was decreased inversely by the thickened porcelain laminate and showed the lowest value to the masking dentin porcelain among 4 kinds of porcelain powder. 2. Bond strength of autopolymerization of dual cured resin without illumination in dark chamber were from 75% to 98% to the data of dual cured resin with illumination. 3. Bond strength of dual cured resin used without chemical cured components were same to them of light cured resin. 4. Cross-sectioned surface treated by silane did not show the gap between the porcelain and resin. 5. Illumination over 80 seconds did not make the significant increase of bond strength on all kinds of resin.

  • PDF

A Study on Thermal Analysis of Dual Beam Laser Welding of Thin Metal Sheet (박판의 이중 빔 레이저 용접에서 열유동 해석에 관한 연구)

  • 김재웅
    • Journal of Welding and Joining
    • /
    • v.15 no.4
    • /
    • pp.99-108
    • /
    • 1997
  • Analytical model for the temperature distribution and the cooling rate of weld in dual beam laser welding is presented for investigating the possibility of controling the cooling rate. The model is based on the solutions to the problem of heat flow due to the distributed and line heat sources for preheating and welding respectively in plates with finite thickness. The effects of beam power, beam distribution parameter, interbeam distance, and welding speed on the resulting temperature distribution and cooling rate are presented. The cooling rates of dual beam laser weld at the weld centerline under the investigated conditions are reduced to as one third of those of welds which were produced by single beam laser. And it appeared that the cooling rate of dual beam laser weld is strongly dependent on the process parameters of preheating laser beam power and welding speed.

  • PDF

Comparison of Hole Mobility Characteristics of Single Channel and Dual Channel Si/SiGe Structure (단일채널 Strained Si/SiGe 구조와 이중채널 Strained Si/SiGe 구조의 이동도 특성 비교)

  • Jung, Jong-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.113-114
    • /
    • 2007
  • Hole mobility characteristics of single surface channel and dual channel Si/SiGe structure are compared, where the former one consists of a relaxed SiGe buffer layer and a tensile strained Si layer on top, and for dual channel structure a compressively strained SiGe layer is inserted between them. Due to the difference of hole mobility enhancement factors of layers between them, hole mobility characteristics with respect to the Si cap thickness shows the opposite tend. Hole mobility increases with thicker Si cap for single channel structure, whereas it decreases with thicker Si cap for dual channel structure.

  • PDF

THE MICROHARDNESS OF RESTORATIVE COMPOSITE AND DUAL-CURED COMPOSITE CEMENT UNDER THE PRECURED COMPOSITE OVERLAY (아르곤레이저를 이용한 레진인레이 하부의 레진 시멘트 및 광중합형 복합레진 중합)

  • Park, Sung-Ho;Lee, Chang-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.109-115
    • /
    • 2000
  • This study was designed to evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay. For restorative materials, Z100 and Tetric Ceram were used. For dual cured composite cements, Variolink II((VL II) of three consistency (low, high, ultra high) were used. To determine the optimal microhardness of Z100, Tetric Ceram and Variolink II, each material was packed into the 1mm thickness teflon mold without composite overlay and light cured for 60 seconds. Then the microhardnesses of each sample were measured, averaged and regarded as optimal hardness of each material. To evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay, the composites were packed into 1mm thickness teflon mold, coverd with celluloid strip, and then precured composite overlay which was made of Targis(Ivoclar/Vivadent, Liechtenstein) was positioned. 2 types of visible light curing machine, the power density of one of which was 400$mW/cm^2$ and the other was 900$mW/cm^2$, and one type of argon laser were used to cure the restorative composite and dual cured cement. For each group, 10 sample were assigned. The light curing tip was positioned over the composite overlay and light cured for 1min., 2min. or 3min with visible light curing machine or 15sec, 30 sec, 45sec, and 60 sec with argon laser. The Vickers hardnesses of upper and lower surface of Z100, Tetric Ceram, and 3 types of VL II cement were measured. When the 900 $mW/cm^2$ curing light was used, 2min. was needed for optimal curing of Z100 and Tetric Ceram. Variolink II did not be cured optimally even though the curing time was extended to 3min. When 400$mW/cm^2$ curing light was used, 3min. was necessary for Z100, whereas 3min. was not enough for Tetric Ceram. Variolink II was not cured optimally even though the curing time was extended to 3min. When argon laser was used, Z100, Tetric Ceram and Variolink II were not cured optimally in 60 seconds.

  • PDF

High performance γ-ray imager using dual anti-mask method for the investigation of high-energy nuclear materials

  • Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2371-2376
    • /
    • 2021
  • As the γ-ray energy increases, a reconstructed image becomes noisy and blurred due to the penetration of the γ-ray through the coded mask. Therefore, the thickness of the coded mask was increased for high energy regions, resulting in severely decreased the performance of the detection efficiency due to self-collimation by the mask. In order to overcome the limitation, a modified uniformly redundant array γ-ray imaging system using dual anti-mask method was developed, and its performance was compared and evaluated in high-energy radiation region. In the dual anti-mask method, the two shadow images, including the subtraction of background events, can simultaneously contribute to the reconstructed image. Moreover, the reconstructed images using each shadow image were integrated using a hybrid update maximum likelihood expectation maximization (h-MLEM). Using the quantitative evaluation method, the performance of the dual anti-mask method was compared with the previously developed collimation methods. As the shadow image which was subtracted the background events leads to a higher-quality reconstructed image, the reconstructed image of the dual anti-mask method showed high performance among the three collimation methods. Finally, the quantitative evaluation method proves that the performance of the dual anti-mask method was better than that of the previously reconstruction methods.

Improving Stability and Characteristic of Circuit and Structure with the Ceramic Process Variable of Dualband Antenna Switch Module (Dual band Antenna Switch Module의 LTCC 공정변수에 따른 안정성 및 특성 개선에 관한 연구)

  • Lee Joong-Keun;Yoo Joshua;Yoo Myung-Jae;Lee Woo-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.2 s.35
    • /
    • pp.105-109
    • /
    • 2005
  • A compact antenna switch module for GSM/DCS dual band applications based on multilayer low temperature co-fired ceramic (LTCC) substrate is presented. Its size is $4.5{\times}3.2{\times}0.8 mm^3$ and insertion loss is lower than 1.0 dB at Rx mode and 1.2 dB at Tx mode. To verify the stability of the developed module to the process window, each block that is diplexer, LPF's and bias circuit is measured by probing method in the variation with the thickness of ceramic layer and the correlation between each block is quantified by calculating the VSWR In the mean while, two types of bias circuits -lumped and distributed - are compared. The measurement of each block and the calculation of VSWR give good information on the behavior of full module. The reaction of diplexer to the thickness is similar to those of LPF's and bias circuit, which means good relative matching and low value of VSWR, so total insertion loss is maintained in quite wide range of the thickness of ceramic layer at both band. And lumped type bias circuit has smaller insertion itself and better correspondence with other circuit than distributed stripline structure. Evaluated ceramic module adopting lumped type bias circuit has low insertion loss and wider stability region of thickness over than 6um and this can be suitable for the mass production. Stability characterization by probing method can be applied widely to the development of ceramic modules with embedded passives in them.

  • PDF

Design of A Dual-resonance PIFA Using U-Type Slot (U-형 슬랏을 이용한 이중 공진 PIFA 설계)

  • Kim, Yoon-Ho;Rhee, Joong-Geun;Kim, Jung-Hun;Jang, Tae-Heon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.11
    • /
    • pp.77-83
    • /
    • 2010
  • This paper presents the dual resonance PIFA(Planar Inverted F-Antenna) which satisfies the requirements of the 802.11n standard at both 2.4 GHz and 5 GHz frequency bands. Patch for 2.4 GHz and U-Type slot for 5 GHz were used for dual resonance, respectively. In this paper, the characteristics of an antenna were investigated by varying locations of short plate and feed point, the width of the short plate, the thickness and the location of U-Type slot. To investigate the characteristics of the PIFA, HFSS(High Frequency Structure Simulation) for the simulation was used. And the measurement results of a fabricated PIFA were compared with the simulated ones. The measurement and simulation results show that good dual resonance characteristics as the thickness of U-type slot decreases and when the location of U-type slot is far from the feed point.