• Title/Summary/Keyword: dual surfaces

Search Result 92, Processing Time 0.021 seconds

An in vitro model of Fusobacterium nucleatum and Porphyromonas gingivalis in single- and dual-species biofilms

  • Tavares, Livia Jacovassi;Klein, Marlise Inez;Panariello, Beatriz Helena Dias;de Avila, Erica Dorigatti;Pavarina, Ana Claudia
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.1
    • /
    • pp.12-21
    • /
    • 2018
  • Purpose: The goal of this study was to develop and validate a standardized in vitro pathogenic biofilm attached onto saliva-coated surfaces. Methods: Fusobacterium nucleatum (F. nucleatum) and Porphyromonas gingivalis (P. gingivalis) strains were grown under anaerobic conditions as single species and in dual-species cultures. Initially, the bacterial biomass was evaluated at 24 and 48 hours to determine the optimal timing for the adhesion phase onto saliva-coated polystyrene surfaces. Thereafter, biofilm development was assessed over time by crystal violet staining and scanning electron microscopy. Results: The data showed no significant difference in the overall biomass after 48 hours for P. gingivalis in single- and dual-species conditions. After adhesion, P. gingivalis in single- and dual-species biofilms accumulated a substantially higher biomass after 7 days of incubation than after 3 days, but no significant difference was found between 5 and 7 days. Although the biomass of the F. nucleatum biofilm was higher at 3 days, no difference was found at 3, 5, or 7 days of incubation. Conclusions: Polystyrene substrates from well plates work as a standard surface and provide reproducible results for in vitro biofilm models. Our biofilm model could serve as a reference point for studies investigating biofilms on different surfaces.

A Study on Scuffing and the Formation of the Protective Layers Based on Dual Film Formation (이중보호막 모델을 이용한 보호막의 형성과 표면파괴에 관한 연구)

  • 이영제
    • Tribology and Lubricants
    • /
    • v.8 no.2
    • /
    • pp.14-19
    • /
    • 1992
  • rate of growth of "protective" films of oxides and compounds derived from the lubricant. The protection afforded by the films is strongly dependent on lubricant and steel composition, initial composite surface roughness and the load/speed sequence or history in the early stages of sliding. The protective films, formed by chemical and mechanical action between lubricant and mating surfaces, delayed the surface roughening and offered higher load capacity. Given the great number of variables involved it is not possible to follow more than a few of the chemical changes on surfaces at the end of experiments. Ellipsometry was therefore used to monitor the formation and loss of dual protective films in real time, and also to find the effect of protective films on scuffing and break-in depending on lubricant conditions.

Survival of surface-modified short versus long implants in complete or partially edentulous patients with a follow-up of 1 year or more: a systematic review and meta-analysis

  • Medikeri, Raghavendra Shrishail;Pereira, Marisca Austin;Waingade, Manjushri;Navale, Shwetambari
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.261-281
    • /
    • 2022
  • Purpose: Short implants are a potential alternative to long implants for use with bone augmentation in atrophic jaws. This meta-analysis investigated the survival rate and marginal bone level (MBL) of surface-modified short vs. long implants. Methods: Electronic and manual searches were performed for articles published between January 2010 and June 2021. Twenty-two randomized controlled trials (RCTs) comparing surface-modified short and long implants that reported the survival rate with at least 1 year of follow-up were selected. Two reviewers independently extracted the data, and the risk of bias and quality of evidence were evaluated. A quantitative meta-analysis was performed regarding survival rate and MBL. Results: The failure rates of surface-modified short and long implants differed significantly (risk ratio, 2.28; 95% confidence interval [CI], 1.46, 3.57; P<0.000). Long implants exhibited a higher survival rate than short implants (mean follow-up, 1-10 years). A significant difference was observed in mean MBL (mean difference=-0.43, 95% CI, -0.63, -0.23; P<0.000), favoring the short implants. Regarding the impact of surface treatment in short and long implants, for hydrophilic sandblasted acid-etched (P=0.020) and titanium oxide fluoride-modified (P=0.050) surfaces, the survival rate differed significantly between short and long implants. The MBL differences for novel nanostructured calcium-incorporated, hydrophilic sandblasted acid-etched, and dual acid-etched with nanometer-scale calcium phosphate crystal surfaces (P=0.050, P=0.020, and P<0.000, respectively) differed significantly for short vs. long implants. Conclusions: Short surface-modified implants are a potential alternative to longer implants in atrophic ridges. Long fluoride-modified and hydrophilic sandblasted acid-etched implants have higher survival rates than short implants. Short implants with novel nanostructured calcium-incorporated titanium surfaces, hydrophilic sandblasted acid-etched surfaces, and dual acid-etched surfaces with nanometer-scale calcium phosphate crystals showed less marginal bone loss than longer implants. Due to high heterogeneity, the MBL results should be interpreted cautiously, and better-designed RCTs should be assessed in the future.

Polymerization of dual cured composites by different thickness (두께에 따른 이중 중합형 복합레진의 중합)

  • Kim, Yun-Ju;Jin, Myoung-Uk;Kim, Sung-Kyo;Kwon, Tae-Yub;Kim, Young-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.169-176
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of thickness, filling methods and curing methods on the polymerization of dual cured core materials by means of microhardness test. Two dual cured core materials, MultiCore Flow (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Bis-Core (Bisco Inc., Schaumburg, IL, USA) were used in this study. 2 mm (bulky filled), 4 mm (bulky filled), 6 mm (bulky and incrementally filled) and 8 mm (bulky and incrementally filled)-thickness specimens were prepared with light cure or self cure mode. After storage at $37{\circ}C$ for 24 hours, the Knoop hardness values (KHN) of top and bottom surfaces were measured and the microhardness ratio of top and bottom surfaces was calculated. The data were analyzed using one-way ANOVA and Scheffe multiple comparison test, with ${\alpha}$= 0.05. The effect of thickness on the polymerization of dual cured composites showed material specific results. In 2, 4 and 6 mm groups, the KHN of two materials were not affected by thickness. However, in 8 mm group of MultiCore Flow, the KHN of the bottom surface was lower than those of other groups (p < 0.05). The effect of filling methods on the polymerization of dual cured composites was different by their thickness or materials. In 6 mm thickness, there was no significant difference between bulk and incremental filling groups. In 8 mm thickness, Bis-Core showed no significant difference between groups. However, in MultiCore Flow, the microhardness ratio of bulk filling group was lower than that of incremental filling group (p < 0.05). The effect of curing methods on the polymerization of dual cured composites showed material specific results. In Bis-Core, the KHN of dual cured group were higher than those of self cured group at both surfaces (p < 0.05). However, in MultiCore Flow, the results were not similar at both surfaces. At the top surface, dual cured group showed higher KHN than that of self cured group (p < 0.05). However, in the bottom surface, dual cured group showed lower value than that of self cured group (p < 0.05).

Polymerization of dual cured composites by different thickness (두께에 따른 이중 중합형 복합레진의 중합)

  • Kim, Yun-Ju;Jin, Myoung-Uk;Kim, Sung-Kyo;Kwon, Tae-Yub;Kim, Young-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.169-176
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of thickness, filling methods and curing methods on the polymerization of dual cured core materials by means of microhardness test. Two dual cured core materials, MultiCore Flow (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Bis-Core (Bisco Inc., Schaumburg, IL, USA) were used in this study. 2 mm (bulky filled), 4 mm (bulky filled), 6 mm (bulky and incrementally filled) and 8 mm (bulky and incrementally filled)-thickness specimens were prepared with light cure or self cure mode. After storage at $37^{\circ}C$ for 24 hours, the Knoop hardness values (KHN) of top and bottom surfaces were measured and the microhardness ratio of top and bottom surfaces was calculated. The data were analyzed using one-way ANOVA and Scheffe multiple comparison test, with ${\alpha}=0.05$. The effect of thickness on the polymerization of dual cured composites showed material specific results. In 2, 4 and 6 mm groups, the KHN of two materials were not affected by thickness. However, in 8 mm group of MultiCore Flow, the KHN of the bottom surface was lower than those of other groups (p < 0.05). The effect of filling methods on the polymerization of dual cured composites was different by their thickness or materials. In 6 mm thickness, there was no significant difference between bulk and incremental filling groups. In 8 mm thickness, Bis-Core showed no significant difference between groups. However, in MultiCore Flow, the microhardness ratio of bulk filling group was lower than that of incremental filling group (p < 0.05). The effect of curing methods on the polymerization of dual cured composites showed material specific results. In Bis-Core, the KHN of dual cured group were higher than those of self cured group at both surfaces (p < 0.05). However, in MultiCore Flow, the results were not similar at both surfaces. At the top surface, dual cured group showed higher KHN than that of self cured group (p < 0.05). However, in the bottom surface, dual cured group showed lower value than that of self cured group (p < 0.05).

  • PDF

The effects of different surface treatments on the shear bond strengths of two dual-cure resin cements to CAD/CAM restorative materials

  • Turker, Nurullah;Buyukkaplan, Ulviye Sebnem;Basar, Ebru Kaya;Ozarslan, Mehmet Mustafa
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.189-196
    • /
    • 2020
  • PURPOSE. The aim of the present study was to investigate the effects of surface treatments on the bond strengths between polymer-containing restorative materials and two dual-cure resin cements. MATERIALS AND METHODS. In the present study, rectangular samples prepared from Lava Ultimate (LU) and Vita Enamic (VE) blocks were used. The specimen surfaces were treated using CoJet sandblasting, 50 ㎛ Al2O3 sandblasting, % 9 HF (hydrofluoric) acid, ER,Cr:YSGG laser treatment, and Z-Prime. Dual-cure resin cements (TheraCem and 3M RelyX U 200) were applied on each specimen's treated surface. A micro-tensile device was used to evaluate shear bond strength. Statistical analysis was performed using the SAS 9.4v3. RESULTS. While the bond strength using TheraCem with LU or VE was not statistically significant (P=.164), the bond strength using U200 with VE was statistically significant (P=.006). In the TheraCem applied VE groups, Z-Prime and HF acid were statistically different from CoJet, Laser, and Sandblast groups. In comparison of TheraCem used LU group, there was a statistically significant difference between HF acid and other surface treatments. CONCLUSION. The bonding performance between the restorative materials and cements were material type-dependent and surface treatment had a large effect on the bond strength. Within the limitations of the study, the use of both U200 and TheraCem may be suggested if Z-prime was applied to intaglio surfaces of VE. The cementation of LU using TheraCem is suitable after HF acid conditioning of the restoration surfaces.

Ka-Band Radiometric Signatures of Vehicles and Land Surfaces (차량과 지표면의 Ka-대역 레디오미터 신호)

  • Ahn, Bierng-Chearl;Park, Seung-Mo;Lim, Tae-Wook
    • Journal of Advanced Navigation Technology
    • /
    • v.2 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • There have been active research efforts in the development of a dual-use millimeter-wave radiometer as an aircraft landing aid in low visibility conditions. In this paper, we constructed a radiometer operating at the Ka-band where it is relatively easy to build RF components. The radiometer is used to collect radiometric signatures of some vehicles and land surfaces. Measured signatures suggest that vehicles with metallic surfaces yield signatures markedly different from nearby land surfaces so that they can easily be detected by a simple radiometer.

  • PDF

Fabrication of a Dual-Gap Substrate Using the Replica-molding Technique for Transflective Liquid Crystal Displays

  • Kim, Yeun-Tae;Hong, Jong-Ho;Cho, Seong-Min;Lee, Sin-Doo
    • Journal of Information Display
    • /
    • v.10 no.2
    • /
    • pp.68-71
    • /
    • 2009
  • A replica-molding method of fabricating a dual-gap substrate for transflective liquid crystal (LC) displays is demonstrated. The dual-gap substrate provides homeotropic alignment for the LC molecules without any surface treatment and embedded bilevel microstructure on one of the two surfaces to maintain different cell gaps between the transmissive and reflective subpixels. The proposed transflective LC cell shows no electro-optic disparity between two subpixels and reduces the panel thickness and weight by 30% compared to the conventional transflective LC cell, which has two glass substrates.

Comparison of removal torque of dual-acid etched and single-acid etched implants in rabbit tibias (단일, 이중 산처리 임플란트의 회전제거력 비교)

  • Kim, Jong-Jin;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.335-341
    • /
    • 2019
  • Purpose: Chemically strong-acids (HF and $HCl/H_2SO_4$) dual etching implant surfaces have higher strengths of osseointegration than machined implant surfaces. However, the dual acid treatment deteriorates the physical properties of the titanium by weakening the fatigue resistance of the implant and causing microcracks. The removal torque comparison between the dual-acid etched (hydrochloric acid, sulfuric acid, HS) and single-acid etched implants (hydrochloric acid, H) could reveal the efficiency of implant surface acid treatment. Materials and methods: Nine $3.75{\times}4mm$ dual-acid etched SLA implants and nine single-acid etched SLA implants were inserted into New Zealand rabbit tibias. After 10 days, removal torque, roughness, and wetting angle were measured. Results: Mean removal torque values were as follows: Mean removal torque were 9.94 Ncm for HS group and 9.96 Ncm for H group (P=.995). Mean surface roughness value were $0.93{\mu}m$ for HS group and $0.84{\mu}m$ for H group (P=.170). Root mean square roughness (RSq) values were $1.21{\mu}m$ for HS group and $1.08{\mu}m$ for H group (P=.294), and mean wetting angle values were $99^{\circ}$ for HS group and $98^{\circ}$ for H group (P=.829). Statistical analysis showed no significant difference between the removal torques, roughness, or wetting angles of the two groups. Conclusion: In this experiment, we found no significant difference in removal torque, roughness, or wetting angle between dual-acid etched and single-acid etched implants.