• Title/Summary/Keyword: dry bridge

Search Result 65, Processing Time 0.024 seconds

The development of power supply for dry scrubber (건식 세정기용 전원장치 개발)

  • 김수석;원충연;최대규;최상돈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.394-399
    • /
    • 2001
  • In this Paper, the development of the power supply for dry scrubber is discussed. 1500w, 100kHz power supply Is designed and tested. The main power stage is used for the FB PWM inverter with an LC filter in the secondary circuit. The operation characteristics of power supply are verified by simulation and experimental results.

  • PDF

A Study on the Repair Method for Performance Degradation Cause of Korean Arch Bridge -Focused on the Seonamsa Seungseonggyo, Songgwangsa Geukrockgyo- (홍예교 성능저하 원인에 따른 보수방안 고찰 - 선암사 승선교·송광사 극락교를 중심으로 -)

  • Kim, Jeong-Eon;Cheon, Deuk-Youm
    • Journal of architectural history
    • /
    • v.23 no.1
    • /
    • pp.7-19
    • /
    • 2014
  • This study considers the proper repair techniques by examining the most representative repair cases of the Korean arch bridges and proposes the constructional manual which can apply similar occasions. The cases are Seonamsa Seungseongyo and Songgwangsa Geukrockgyo where this researcher had taken part in the repair works. This Study proposes the maintenance construction manual about the performance degradation drew by performance degradation of the both Korean arch bridges in the maintenance process. First, arch bridge maintenance should be carried out in the dry season, when water is impermeable in the bottom surface of the bridge. Moreover, risk factors of the maintenance should be excluded to secure the water vally flow, the bypass and the temporary bridge. Second, prior to repair, it has to precede (1)3D shooting (2)formal examination (3)structure safety test (4)geological and lithic surveys (5)arch curvature establishment and makeshift frame settlement before transformation (6)relationship expert comments. Third, if the baduk and the foundation stones are inevitable to replace due to performance degradation on the foundation, it should use the high quality stones and secure greater stress by extending the standard range. The foundation on irregular rock needs to be flattened and underside on the replaced materials require Grengyijil to deliver the equal loads. Fourth, In the process of dismantling the stones of the arched bridge, it could make heavy weathering degree and not reuse the materials. Charge should converge the expert advices to choose the reuseable, the conservate and the alternative materials, and increase the reutilization of the raw materials by preservation and reinforcement treatments. Fifth, the side wall should be repaired by the rubble work technique which is not able to pile compost satiety, so it must use long depth of masonary stones for reinforcement. It is considered to reinforce the stone wall in shore as much as possible and protect the abutment and the side wall on the upstream for the arch bridge maintenance works.

A Study on Thermal performance as Form of Steel stud by Using Thermal Video Camera (열화상 카메라를 이용한 건식벽체의 스틸스터드 형상에 따른 열성능 비교연구)

  • Jang, Cheol-Yong;Um, Eun-Jung;Lee, Na-Eun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.236-240
    • /
    • 2009
  • Dry wall using steel stud has the advantage of possibility to install various building, so it used to many buildings inside and outside of the country very rapidly. Though Light gauge steel framed housing offers many advantages to the consumer and the builder, the use of steel studs in wall system cause thermal problems such as thermal performance and pattern staing on walls. The present study has been conducted to observe effect of stud by the shape, and two kind of stud is made for this test to compare thermal performance. The test was conducted by setting those stud on the chamber and heating them. As the results of test and photograping by using TVS, there was temperature gap of each stud, and surface temperature of each section was appeared differently due to shape of stud delaying thermal bridge.

  • PDF

Washoff Characteristics and Correlation of Nonpoint pollutants in a Bridge Storm Runoff (교량 강우유출수내 비점오염물질의 유출특성 및 상관성)

  • Wee, Seung-Kyung;Kim, Lee-Hyung;Jung, Yong-Jun;Gil, Kyung-Ikt
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.378-382
    • /
    • 2008
  • During the dry periods, many types of pollutants are being accumulated on the paved surface by vehicle activities and the accumulated various pollutants are inflowing into the near watershed areas for the rainfall periods. Particularly, bridges are the centralized region to be the surface runoff of the stromwater due to the high ratio of the impermeable area. Also, the metals, toxic chemicals and sediments originated from bridges could be strongly influenced to the watershed areas during the runoff. Therefore, the present study is achieved to provide washoff characteristics and correlation from the bridge during rainfall periods. The result shows that the EMC ranges for 95% confidence intervals in a bridge land use are 10.12~128.09 mg/L for TSS, 6.07~21.15 mg/L for BOD, 2.10~6.70 mg/L for TN and 0.06~0.85 mg/L for TP.

Numerical study of stress states near construction joint in two-plate-girder bridge with cast-in-place PC slab

  • Yamaguchi, Eiki;Fukushi, Fumio;Hirayama, Naoki;Kubo, Takemi;Kubo, Yoshinobu
    • Structural Engineering and Mechanics
    • /
    • v.19 no.2
    • /
    • pp.173-184
    • /
    • 2005
  • For reducing construction cost, two-plate-girder bridges are getting popular in Japan. This type of bridge employs a PC slab, which is often cast-in-place. In such a case, concrete is not usually cast over the whole slab at one time: some portions are constructed earlier than the rest. Therefore, a construction joint is inevitably created. Due to the drying shrinkage of concrete, tension stress may occur in concrete slab. High tensile stress can be expected near the construction joint where concretes with different ages meet. Moreover, prestressing is not applied over the whole length of slab at one time. This may also serve as a source of tensile stress in the slab. Thus there is a chance that cast-in-place PC slab, especially near the construction joint, may be subjected to tensile cracking. In the present study, stress states near the construction joint in the cast-in-place PC slab of a two-plate-girder bridge are investigated numerically. The finite element method is employed and the three-dimensional analysis is conducted to see the influence of dry shrinkage and prestressing. The stress states in the PC slab thus obtained are discussed. The simplified model of a plate girder for this class of analysis is also proposed.

Analysis of Strengthening Veriables for Strengthened Bridge Decks by Externally Bonded Sheet (보강판으로 외부부착 보강된 교량 바닥판의 성능향상을 위한 변수 해석)

  • 심종성;오흥섭
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.556-565
    • /
    • 2002
  • The concrete bridge decks on the main girder will usually develop initial cracks in the longitudinal or the transverse direction due to dry shrinkage and temperature change, and as the bridge decks age the crack will gradually develop in different directions due to repeated cyclic loads. The strengthening direction of the concrete bridge deck is a very important factor in improving proper structural behavior. Therefore, in this study, theoretical analyses of strengthened bridge decks were performed using the nonlinear finite element method. To improve the accuracy of the analytical result, boundary conditions and material property of strengthening material was simulated by laboratory condition and test results, respectively. The effect of the strengthening direction and the amount of strengthening material were estimated and compared to the experimental results. The efficiency of the strengthened bridge decks by strengthening variables such as the amount, width and thickness of CFS was observed.

An experimental study on the development and verification of NCC(new concrete cutting) system

  • Park, Jong-Hyup;Han, Jong-Wook
    • Structural Engineering and Mechanics
    • /
    • v.65 no.2
    • /
    • pp.203-211
    • /
    • 2018
  • This paper introduces the development process of NCC(New Concrete Cutting) system and analyzes first verification test. Based on the first verification test results, some problems of NCC system have been newly modified. We carry out the second verification test. We tried to verify cutting performance and dust control efficiency of NCC system through the cutting test of concrete bridge piers. In particular, this verification test strives to solve the problem of concrete dust, which is the biggest problem of dry cutting method. The remaining dust problems in cutting section tried to solve through this verification test. This verification test of the NCC system shows that the dust problem of dry cutting method is closely controlled and solved. In conclusion, the proposed NCC method is superior to the dry cutting method in all aspects, including cutting performance, dust vacuum efficiency and cooling effect. The proposed NCC system is believed to be able to provide eco-friendly cutting technology to various industries, such as the removal of the SOC structures and the dismantling of nuclear plants, which have recently become a hot issue in the field of concrete cutting.

Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame (트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가)

  • Song, Jin-Hee;Lee, Dong-Yun;Shin, Dong-Il;Jun, Hyun-Do;Park, Cheol-Yong;Kim, Sang-Kyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.6
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.

Prediction Model of Chloride Penetration in Concrete Bridge Deck Considering Environmental Effects (대기 환경조건을 고려한 콘크리트 교량 바닥판의 염소이온 침투 예측 모델)

  • Kim, Eui-Sung
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.59-66
    • /
    • 2008
  • Recently, the deterioration of reinforced concrete structures, primarily due to corrosion of steel reinforcement, has become a major concern. Chloride-induced deterioration is the most important deterioration phenomenon in reinforced concrete structures in harsh environments. For the realistic prediction of chloride penetration into concrete, a mathematical model was developed in which the effects of diffusion, chloride binding and convection due to water movement can be taken into account. The aim of this research was to reach a better understanding on the physical mechanisms underlying the deterioration process of reinforced concrete associated with chloride-induced corrosion and to propose a reliable method for estimating these effects. Chloride concentrations coming from de-icing salts are significantly influenced by the exposure conditions such as salt usage, ambient temperature and repeated wet-dry cycles.

Research of the TFT-LCD Photosensitive Resist Thickness

  • Zhang, Mi;Xue, Jian She;Wang, Wei;Park, Chun-Bae;Koh, Jai-Wan;Zhang, Zhi-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1269-1271
    • /
    • 2008
  • We find some array mura are caused by S/D bridge or channel open in 4 mask process. The gray tone PR thickness non-uniformity is the main reason of these defects. By the adjustment of exposure and dry etch parameters, S/D bridge and channel open ratio drops by 10.87%.

  • PDF