• Title/Summary/Keyword: droplet size

Search Result 639, Processing Time 0.036 seconds

Design Parameters and Experimental Performance Evaluation of 4-bit Digital Multi-heater Microinjector (4-bit 디지털 미소분사기의 설계변수와 토출성능간의 영향분석에 관한 실험적 연구)

  • Kang Tae Goo;Cho Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.3 s.234
    • /
    • pp.418-424
    • /
    • 2005
  • We present the design, fabrication and experimental results of 4-bit digital microinjectors, whose ejected droplet volumes are adjusted by the digital operation of a 4-bit microheater array. We design the reference microinjectors as well as its comparative test structures. In the fabrication process, we use a five-mask micromachining process and the total chip size of the fabricated microinjector is $7,640{\mu}m{\times}5,260{\mu}m.$ We measure the ejected droplet volumes and velocities, which are adjusted from $12.1{\pm}1.0~55.6{\pm}14.7pl\;and\;2.3{\pm}0.1~15.7{\pm}0.8m/s.$ respectively, depending on the 15 possible combinations of 4-bit microheater array. We also experimentally characterize the effect of geometric variation including the microheater size, inter-microheater gap, microchannel width and sequential operation of microheater array on the ejected droplet volume and velocity. Among these parameters, we find that the microheater size is the most dominant parameter affected to the ejected droplet volumes and velocities. Thus, the present microinjector has a potential for application to the high-resolution inkjet printers with multiple gray levels or high-precision fluid injectors with variable volume control.

An Elementary Study on the Combustion Mechanism of Levitated Droplet Clusters by Ultrasonic Wave (초음파를 이용한 부상유적군의 연소기구에 관한 기초연구)

  • Jung, Jin-Do;Kim, Seung-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1191-1199
    • /
    • 2003
  • This paper describes to observe the combustion process of only one droplet cluster. In this study, liquid fuel was atomized by ultrasonic wave to form an acoustically levitated droplet cluster. In order to elucidate the detailed structure of burning process of the droplet cluster, laser tomography method was applied. Time-series planar images of fuel droplets were processed and diameter of the each droplet was calculated based on the Mie-scattering theory. Using these data, the modified droplet group combustion number was estimated in time-series. As the result, when the internal droplet group combustion occur, the modified group combustion number dose not decrease monotonically, but show a tow-staged decreasing process. In all case of combustion process, combustion reactions were measured two types that combustion speed was fast and slow. It was casued by difference of concentration degree and droplet size distribution.

A Study of Droplet Generation, fragmentation and Separation in Microchannel (마이크로채널 내에서 DROPLET 생성, 분기 및 분리에 관한 연구)

  • Jeong Eun Ho;Go Jeung Sang;Arakawa Takahiro;Shoji Shuichi;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.94-97
    • /
    • 2004
  • Study of a micro chemical plant consisted with droplet generation, digital sorting and separation was conducted. The droplet generation was quantitatively characterized. The digital sorting brought effective reaction by shortening the droplet size and the pitch of droplet generation simultaneously. To prevent the unfavorable higher order reaction, perfect separation of droplets was visualized.

  • PDF

Numerical Study of Droplet Motion in a Microchannel with defferent contact angles (접촉각에 따른 마이크로채널 내에서의 액적 거동에 대한 수치적 연구)

  • Choi, Ji-Young;Son, Gi-Hun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.656-657
    • /
    • 2008
  • The droplet dynamics in a hydrophilic/hydrophobic microchannel, which is applicable to a typical proton exchange membrane fuel cell (PEMFC), is studied numerically by solving the equations governing conservation of mass and momentum. The liquid-gas interface or droplet shape is determined by a level set method which is modified to treat contact angles. The matching conditions at the interface are accurately imposed by incorporating the ghost fluid approach based on a sharp-interface representation. The effects of contact angle, inlet flow velocity, droplet size and side wall on the droplet motion are investigated parametrically. Based on the numerical results, the droplet dynamics including the sliding and detachment of droplets is found to depend significantly on the contact angle. Also, a droplet removal process is demonstrated on the combination of hydrophilic and hydrophobic surfaces.

  • PDF

Droplet Bistability in Microchannel and its Application to Flow Control (마이크로 채널 내부에서의 액적의 쌍안정성과 이를 활용한 유동 제어)

  • Lee, Beom-Joon;Yoo, Jung-Yul
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.43-47
    • /
    • 2010
  • We demonstrate the droplet bistability in a microchannel which has two symmetric necks that operate as capillary valves. It is shown that there are certain flow conditions, determined by droplet velocity and droplet size, to achieve bistability. Droplet bistabililty allows simple but precise control of droplet at a bifurcation channel. Therefore, by an appropriate channel design to induce droplet bistability, we can distribute droplets at a junction passively in the manner of perfect alternation and perfect switching in the choice of the outlets.

Self-healing capsule manufacturing and characteristic analysis using microfluidic control method droplet manufacturing technology (미세 유체제어 방식 드랍렛 제작 기술을 이용한 자가치유 캡슐 제작 및 특성 분석)

  • Ji, Dong-min;Song, Won-Il;lee, ja sung;Ramos-Sebastian, Armando;Kim, S-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.251-252
    • /
    • 2022
  • The microfluidic controlled droplet manufacturing system is one of the most powerful methods for capsule manufacturing. The microfluidic control method can control the type and size of the capsule by changing the size and configuration of the channel. In addition, by increasing the number of channels, capsules of uniform size can be mass-produced. In this paper, a capsule manufacturing system including flow-focusing and T junction method was designed. In addition, the effectiveness of this system was verified by manufacturing multi-emulsion capsules with a size of 2.2 to 3 mm.

  • PDF

Numerical Analysis on Interaction between Fire Flame and Water Mist according to the Variation of Nozzle Performance (노즐 특성 변화에 따른 미분무수와 화염과의 상호작용에 관한 수치해석)

  • Bae, Kang-Youl;Chung, Hee-Taeg;Kim, Hyoung-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2983-2988
    • /
    • 2007
  • In the present study, the numerical investigation on the effects of water-mist characteristics has been carried out for the fire suppression mechanism. The FDS are used to simulate the interaction of fire plume and water mists, and program describes the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The numerical model is consisted of a rectangular enclosure of $L{\times}W{\times}H=1.5{\times}1.5{\times}2.0m$ and a water mist nozzle that be installed 1.8m from fire pool. In the study, the parameters of nozzle for simulation are the droplet size and the spray velocity. Finally, the droplet size influences to fire flume on fire suppression than spray velocity because of the effect of terminal velocity, and the optimal condition for fire suppression is that the droplet size and the spray velocity are $100{\mu}m$ and 20m/s, respectively.

  • PDF

Numerical Study on the Effects of Spray Properties of Water Mist on the Fire Suppression Mechanism (미분무수 특성이 화재억제 메커니즘에 미치는 영향에 대한 수치해석적 연구)

  • Bae, Kang-Youl;Chung, Hee-Taeg;Kim, Hyoung-Bum
    • Journal of ILASS-Korea
    • /
    • v.22 no.4
    • /
    • pp.175-184
    • /
    • 2017
  • The numerical investigation on the effects of water-mist characteristics has been carried out for the fire suppression mechanism. The FDS are used to simulate the interaction of fire plume and water mists, and program describes the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The numerical model is consisted of a rectangular enclosure of $L{\times}W{\times}H=1.5{\times}1.5{\times}2.0m^3$ and a water mist nozzle that be installed 1.8 m from fire pool. In the present study, the parameters of nozzle for simulation are the droplet size and the spray velocity. The droplet size influences to fire flume on fire suppression more than the spray velocity because of the effect of the terminal velocity. The optimal condition for fire suppression is that the droplet size and the spray velocity are $100{\mu}m$ and 20 m/s respectively.

Effect of Air Stagnation Conditions on Mass Size Distributions of Water-soluble Aerosol Particles (대기 정체와 수용성 에어로졸 입자의 질량크기분포의 관계)

  • Park, Seungshik;Yu, Geun-Hye
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.3
    • /
    • pp.418-429
    • /
    • 2018
  • Measurements of 24-hr size-segregated ambient particles were made at an urban site of Gwangju under high pressure conditions occurred in the Korean Peninsula late in March 2018. The aim of this study was to understand the effect of air stagnation on mass size distributions and formation pathways of water-soluble organic and inorganic components. During the study period, the $NO_3{^-}$, $SO_4{^{2-}}$, $NH_4{^+}$, water-soluble organic carbon (WSOC), and humic-like substances(HULIS) exhibited mostly bi-modal size distributions peaking at 1.0 and $6.2{\mu}m$, with predominant droplet modes. In particular, outstanding droplet mode size distributions were observed on March 25 when a severe haze occurred due to stable air conditions and long range transport of aerosol particles from northeastern regions of China. Air stagnation conditions and high relative humidity during the study period resulted in accumulation of primary aerosol particles from local emission sources and enhanced formation of secondary ionic and organic aerosols through aqueous-phase oxidations of $SO_2$, $NO_2$, $NH_3$, and volatile organic compounds, leading to their dominant droplet mode size distributions at particle size of $1.0{\mu}m$. From the size distribution of $K^+$ in accumulation mode, it can be inferred that in addition to the secondary organic aerosol formations, accumulation mode WSOC and HULIS could be partly attributed to biomass burning emissions.

A Prediction Model of Droplet Size of Rotary Spray Dryer at Various Operating Conditions (원심식(遠心式) 분무건조장치(噴霧乾燥裝置)의 작동조건(作動條件)에 따른 분무입자(噴霧粒子)의 입도예측(粒度豫測) 모델)

  • Noh, S.H.;Kim, K.B.;Lee, J.W.;Lee, S.J.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.3
    • /
    • pp.229-236
    • /
    • 1992
  • In an effort to localize the spray-dryer which is markedly used for drying food materials, a experiment was carried out with a wheel type atomizer locally designed and manufactured to evaluate the effect of rotational speed, feed rate and physical properties of liquid food material on the droplet size, and to develop a model to predict the droplet size sprayed at various operational conditions. The result are summarized as follows. 1. The frequency of droplet size sprayed from the atomizer at every treatment were similar to normal distributions. 2. Under the test conditions adopted in this study, that is, rotational speed of the atomizer ranging from 15,000 to 20,000 rpm (55.0 m/sec - 73.3 m/sec), feed rate from 14 to 37 kg/hr and viscosity of the material from 1.14 to 350 cP, the mean volume-surface dia. of droplets was decreased as increase in rotational speed and was not affected significantly by the feed rate and viscosity. 3. Through the dimensional analysis, a prediction model was developed as follows : $$\frac{Dvs}{r}=K[\frac{Q}{{\mu}r}]^a[\frac{rN^2}{g}]^b[\frac{{\rho}^2r^3g}{{\mu}^2}]^c[\frac{L}{r}]^d$$ and it was proved that the above model was better in degree of fitness than other models reported. 4. A prediction equation for the droplet size sprayed from the atomizer under the test was expressed as follows : $$\frac{Dvs}{r}=0.0215[\frac{Q}{{\mu}r}]^{0.06}[\frac{rN^2}{g}]^{0.3314}[\frac{{\mu}^2}{{\rho}^2r^3g}]^{0.0158}$$.

  • PDF