Experimental Investigations on Slamming Impacts by Drop Tests (낙하실험에 의한 슬래밍 충격의 실험 연구)

  • Shin, Hyun-Kyoung;Kim, Sung-Chul;Cho, Sang-Rai
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.3
    • /
    • pp.410-420
    • /
    • 2010
  • When ships are sailing with large motions in rough waves, the slamming phenomenon occurs and the ships suffer from impulsive pressure loadings. Recently, ships are becoming lager and faster than before and it becomes more possible that the ships experience larger impacts on their bows and sterns. Many researchers have been performing the investigations on slamming experimentally and theoretically for a long time. Most of the research reported in the open literature focused on how to accurately estimate the amplitude of the peak pressure of slamming. According to the results of a recently published work, not only the amplitude of peak pressure but also the width of the peak may play an important role in predicting the extents of damage of impacted structures. The uncertainty of impulsive pressure loadings due to slamming has been indicated by many researchers. However, probabilistic treatments of the impulsive pressure loadings are few. In this study, drop tests were conducted on wedges having dead-rise angles of $0^{\circ}$ and $10^{\circ}$. Not only the amplitude of peak pressure but also the width of peak pressure were measured. Furthermore, the variations of those values are also provided for the probabilistic approach of the slamming problem.

Empirical Study on the Prediction of Rain Attenuation in EHF(44 GHz) Band (EHF(44 GHz) 대역 강우 감쇠 특성 예측 연구)

  • Park Yong-Ho;Lee Joo-Hwan;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.848-854
    • /
    • 2005
  • The attenuation due to rain has been recognized as one of the major causes of unavailability of radio communication systems operating above about 10 GHz. To design radio links for telecommunications and to evaluate attenuation due to rainfall, it is important to have a good prediction model for rain attenuation such as a model for drop-size distribution of rainfall(DSD), a theoretical model for specific rain attenuation, and an empirical model fur effective path length through rain. In this paper, the extended generalized gamma distribution for drop-size distribution, based on the measurements in Chnugnam National University, is proposed as a new DSD model, and predicted specific attenuation characteristics using proposed DSD model and rain attenuation values in the 44 GHz satellite path using ITU-R effective path length model, are analysed. The predicted attenuation levels are also compared. It is found that an accurate prediction method for DSD is very important to reduce the prediction error in the local satellite path.

Gaussian Kernel Smoothing of Explicit Transient Responses for Drop-Impact Analysis (낙하 충격 해석을 위한 명시법 과도응답의 가우스커널 평활화 기법)

  • Park, Moon-Shik;Kang, Bong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.3
    • /
    • pp.289-297
    • /
    • 2011
  • The explicit finite element method is an essential tool for solving large problems with severe nonlinear characteristics, but its results can be difficult to interpret. In particular, it can be impossible to evaluate its acceleration responses because of severe discontinuity, extreme noise or aliasing. We suggest a new post-processing method for transient responses and their response spectra. We propose smoothing methods using a Gaussian kernel without in depth knowledge of the complex frequency characteristics; such methods are successfully used in the filtering of digital signals. This smoothing can be done by measuring the velocity results and monitoring the response spectra. Gaussian kernel smoothing gives a better smoothness and representation of the peak values than other approaches do. The floor response spectra can be derived using smoothed accelerations for the design.

Cooling Heat Transfer Characteristics of CO2 in Helical Coil Type Gas Coolers (헬리컬 코일형 가스냉각기 내 CO2의 냉각 열전달 특성)

  • Son, Chang-Hyo;Jeon, Min-Ju;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.699-706
    • /
    • 2007
  • The cooling heat transfer coefficient and pressure drop of $CO_2$(R-744) in helical coil copper tubes were investigated experimentally The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter. a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55mm inner diameter The refrigerant mass fluxes were varied from 200 to $600 [kg/m^2s]$ and the inlet pressures of 9as cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively food agreement with those Predicted by Ito's correlation developed for single-phase in helical coil tubes. Though a few correlation available with the data. the local heat transfer coefficient of $CO_2$ agrees well with those presented by Pitla et al. among the predictions. However at the region near pseudo-critical temperature. the experiment data indicate higher values than the Pitla et al. correlation.

Deriving the Rate Constants of Coal Char-CO2 Gasification using Pressurized Drop Tube Furnace (가압 DTF를 이용한 석탄 촤-CO2 가스화 반응상수 도출)

  • Sohn, Geun;Ye, Insoo;Ra, Howon;Yoon, Sungmin;Ryu, Changkook
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.4
    • /
    • pp.19-26
    • /
    • 2017
  • This study investigates the gasification of coal char by $CO_2$ under high pressures in a drop tube furnace(DTF). The rate constants are derived for the shrinking core model using the conventional method based on the set reactor conditions. The computational fluid dynamic(CFD) simulations adopting the rate constants revealed that the carbon conversion was much slower than the experimental results, especially under high temperature and high partial pressure of reactants. Three reasons were identified for the discrepancy: i) shorter reaction time because of the entry region for heating, ii) lower particle temperature by the endothermic reaction, and iii) lower partial pressure of $CO_2$ by its consumption. Therefore, the rate constants were corrected based on the actual reaction conditions of the char. The CFD results updated using the corrected rate constants well matched with the measured values. Such correction of reaction conditions in a DTF is essential in deriving rate constants for any char conversion models by $H_2O$ and $O_2$ as well as $CO_2$.

Effects of Wearing Spandex Pants on Impact Forces and Muscle Activities during Drop Landing (드롭 착지 동작 시 탄성 섬유 바지 착용이 충격력과 근육 활동에 미치는 영향)

  • Chae, Woen-Sik;Kang, Nyeon-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.603-610
    • /
    • 2009
  • The purpose of this study was to determine how spandex pants affect impact force and muscle activities in the lower extremity. Seven pairs of surface electrodes were attached to the right-hand side of the body. Paired t-test was performed to test if significant difference exist between two conditions(p< .05). The average IEMG activities in the TA, BF, and GM during the landing phase reduced significantly with spandex pants compared to regular pants. All peak IEMG activities except the RF in wearing spandex pants group were significantly greater than the corresponding values in wearing regular pants one. The greater muscle activity recorded in wearing spandex pants can be attributed to the greater motor unit recruitment needed to decelerate and stabilized their bodies. Impact force and loading rate were not significantly decreased with wearing spandex pants. Since the spandex pants used in this study were not custom-fit based on girth of each participants thigh and shank, compression and elasticity for the pants could not be optimized.

A Simple Method for Measuring the Immobilization Solids of Coating Colors Using an AA-CWR Water Retention Meter

  • Park, Chang-hak;Lee, Do-Ik;Margaret K. Joyce
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.5
    • /
    • pp.39-48
    • /
    • 2002
  • The water retention of coating colors can be accurately measured by devices such as an AA-GWR water retention meter whose principle of measurement Is based on pressure filtration of coatings under an externally applied air pressure over a certain period of time. It was hypothesized that such devices could be also used to determine the immobilization solids (IMS) of coating colors by determining a sudden drop in the rate of dewatering, that is, a sudden change in the drainage curves. To test this hypothesis, the immobilization solids of coating colors containing various thickeners and water retention additives at different levels were first accurately measured by a modified immobilization tester based on the well-known gloss drop method, and then their values were compared with those obtained by an AA-GWR water retention tester. They agreed very well and showed that the standard deviation is only 0.14% in the IMS points between both methods. This good agreement was not surprising because both test methods are based on the same end-point, that is, the immobilization solids point at which menisci begin to form at the coating surface. Theoretical considerations supporting this new method for measuring the immobilization solids of coating colors are presented and some recommendations for the test method are discussed. Also, the effect of various thickeners and water retention additives on the properties and printability of coated papers is discussed.

Wettability of denture relining materials under water storage over time

  • Jin, Na-Young;Lee, Ho-Rim;Lee, Hee-Su;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2009
  • STATEMENT OF PROBLEM. Poor wettability of denture relining materials may lead to retention problems and patient discomfort. PURPOSE. Purpose of this study is to compare and evaluate wettability of nine denture relining materials using contact angle measurements under air and water storage over time. MATERIAL AND METHODS. Nine denture relining materials were investigated in this study. Two heat-curing polymethyl-methacrylate(PMMA) denture base materials: Vertex RS, Lang, one self-curing polyethyl-methacrylate(PEMA) chairside reline resin: Rebase II, six silicone relining materials: Mucopren soft, Mucosoft, $Mollosil^{{R}}$ plus, Sofreliner Touch, GC $Reline^{TM}$ Ultrasoft, Silagum automix comfort were used in this experiment. Contact angles were measured using high-resolution drop shape analysis system(DSA 10-MK2, KRUESS, Germany) under three conditions(in air after setting, 1 hour water storage, and 24 hours water storage). Nine materials were classified into three groups according to material composition(Group 1: PMMA, Group 2: PEMA, Group 3: Silicone). Mean values of contact angles were compared using independent samples t-test and one-way ANOVA, followed by a Scheffe's post hoc analysis($\alpha$=0.01). RESULTS. Contact angles of materials tested after air and water storage increased in the following order: Group 1(PMMA), Group 2(PEMA), Group 3(Silicone). Heat-cured acrylic denture base resins had more wettability than silicone relining materials. Lang had the highest wettability after 24 hours of water storage. Silicone relining materials had lower wettability due to their hydrophobicity. Wettability of all denture relining materials, except Rebase II and $Mollosil^{{R}}$ plus, increased after 24 hours of water storage. CONCLUSIONS. Conventional heat-cured resin showed the highest wettability, therefore, it can be suggested that heat-cured acrylic resin is material of choice for denture relining materials.

Test and Analysis of 3-D of Leakage Impedances in a Single-Phase 1MVA HTS Transformer (단상 1MVA 고온초전도 변압기의 누설임피던스 3차원 해석 및 시험)

  • Kim, Sung-Hoon;Kim, Woo-Seok;Lee, Sang-Jin;Choi, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Hahn, Song-Yop;Song, Hee-Suck;Park, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1003-1005
    • /
    • 2003
  • In this paper, 3-D nonlinear electromagnetic analysis of a single phase 1MVA 22.9 kV/6.6 kV high temperature superconducting(HTS) transformer with double pancake windings was accomplished. The characteristics of 1MVA HTS transformer such as The efficiency, voltage regulation and % impedance voltage drop were obtained by the 3-D non-linear electromagnetic analysis. And in order to verify the 3-D non-linear electromagnetic analysis of a single phase 1MVA HTS transformer, a 1MVA test transformer with windings made of copper tapes with the same size as BSCCO-2223 HTS tape was manufactured. The energy conservation method to perform the analysis of leakage impedances of both a 1MVA HTS transformer and test transformer was used. The characteristic analysis such as efficiency, voltage regulation and % impedance voltage drop of transformer was performed. And the obtained values of both 1MVA HTS transformer and test transformer were compared.

  • PDF

Evaluation of Tear Film Lipid Layer Thickness Measurements Obtained Using an Ocular Surface Interferometer in Nasolacrimal Duct Obstruction Patients

  • Lee, Sang Min;Chung, Sok Joong;Lew, Helen
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.445-450
    • /
    • 2018
  • Purpose: To compare the tear film lipid layer thickness (LLT) between patients with incomplete nasolacrimal duct obstruction (NLDO) and normal controls and to analyze the changes in tear film LLT and blinking pattern after silicone tube intubation in NLDO patients. Methods: We reviewed the medical records of 68 eyes in 52 incomplete NLDO patients who underwent silicone tube intubation from January 2017 to July 2017. The LLT, blinking pattern, and Meibomian gland image were measured with the LipiView II ocular surface interferometer. The Meibomian gland drop-out ratio was measured using the polygon selection tool in the Image J program. Tear meniscus height, which is the other lacrimal indicator, was assessed with spectral-domain optical coherence tomography. Results: Tear meniscus height was significantly decreased after silicone tube intubation (p < 0.01). Preoperative minimum, maximum, and average LLT values were $62.4{\pm}24.0$, $86.7{\pm}17.9$, and $71.7{\pm}23.3nm$, respectively. Significant changes in the minimum, maximum, and average LLT ($74.8{\pm}23.6$, $98.8{\pm}11.0$, and $91.6{\pm}16.1nm$, respectively) were observed after silicone tube intubation (p < 0.001, p = 0.001, and p < 0.001). The partial blinking/total blinking ratio in 20 seconds and the Meibomian gland drop-out ratio showed no significant change after silicone tube intubation. Conclusions: Overall, the LLT was increased after silicone tube intubation. Silicone tube intubation may be helpful in maintaining LLT with a normalized of amount of tears.