• 제목/요약/키워드: droop

검색결과 204건 처리시간 0.022초

마이크로그리드 과도상태 시 전력 수급 균형 전략 (Power Balancing Strategy in the Microgrid During Transient)

  • 서재진;이학주;정원욱;원동준
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.707-714
    • /
    • 2010
  • When problems such as line fault, breakdown of a substation or a generator, etc. arise on the grid, the Microgrid is designed to be separated or isolated from the grid. Most existing DGs(Distributed Generators) in distribution system use rotating machine. However, new DGs such as micro gas turbine, fuel cell, photo voltaic, wind turbine, etc. will be interfaced with the Microgrid through an inverter. So the Microgrid may have very lower inertia than the conventional distribution system. By the way, the rate of change of frequency depends on the inertia of the power system. Moreover, frequency has a strong coupling with active power in power system. Because the frequency of the Microgrid may change rapidly and largely during transient, appropriate and fast control strategy is needed for stable operation of the Microgrid. Therefore, this paper presents a power balancing strategy in Microgrid during transient. Despite of strong power or frequency excursions, power balancing in the Microgrid can be maintained.

실험실 규모에서 고온 섬유 여과재를 이용한 방향족 유기화합물 제거 특성 조사 (Removal Efficiency Study of Aromatic Hydrocarbons Using a High-Temperature Fiber Filter on a Laboratory Scale)

  • 이학성;강병욱;이상권;한영욱;한범
    • 한국환경과학회지
    • /
    • 제8권4호
    • /
    • pp.473-477
    • /
    • 1999
  • The purpose of this study was to investigate the characteristics of removal efficiency for aromatic hydrocarbons using a high-temperature fiber filter on a laboratory scale. The main elemental compositions of a high-temperaure fiber filter are aluminium and silica, which can act as the catalysts. Benzene, toluene and o-xylene among aromatic hydrocarbons were used in this experiment. For 3cm thickness of fiber filter, these compounds were removed more than 90% at the face velocities of 3cm/sec and 5cm/sec above 45$0^{\circ}C$. For 4cm thickness of it, the removal efficiencies of these compounds were almost 90% from 40$0^{\circ}C$ at the same face velocities, suggesting that it may be due to increasing the contact time between the fiber filter and aromatic hydrocarbons. The pressure droop ranged from 22 to 48mmH2O for 3cm thickness of fiber filter. However, for 4cm thickness of it, it was about two times(41~89mm$H_2O$) higher than that for 3cm fiber thickness.

  • PDF

정보통신용 다병렬 운전의 모듈식 무정전전원장치 (Module UPS of multi-parallel operation for use in information & telecommunication systems)

  • 구태근;류지수;배상규;박근갑
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

바이폴 ±750 직류 배전망 연계용 태양광 발전 시뮬레이터 구현 (Implementation of a Photovoltaic System Simulator for Interconnecting with Bipolar ±750V DC distribution Grid)

  • 김태훈;김석웅;조진태;김주용;정재승
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1800-1805
    • /
    • 2016
  • The micro-grid designed as bipolar ${\pm}750V$ low-voltage DC power distribution system demonstrated by KEPRI, demands interconnection of a number of small decentralized power source including variable renewable generator. Therefore, variable researches for the influence of interconnection with the bipolar typed DC grid and these variable power sources are required for superior quality of power distribution. Renewable power generation simulators for the bipolar ${\pm}750V$ low-voltage DC power distribution system are necessary for such researches. In this paper, we carry out a research on the photovoltaic simulator that be actually able to interconnect with a bipolar ${\pm}750V$ low-voltage micro-grid. Simulator for this research is not only able to simulate photovoltaic generation according to weather informations and PV modules characteristics, but also contribute to stabilization of bipolar ${\pm}750V$ low-voltage of the system. Therefore, the simulator was designed to develop a system that can situationally respond to variable control algorithms such as the MPPT control, droop control, EMS power control, etc.

A New Approach to Direct Torque Control for Induction Motor Drive Using Amplitude and Angle of the Stator Flux Control

  • Kumsuwan, Yuttana;Premrudeepreechacharn, Suttichai;Toliyat, Hamid A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.79-87
    • /
    • 2008
  • This paper proposes the design and implementation of a direct torque controlled induction motor drive system. The method is based on control of decoupling between amplitude and angle of reference stator flux for determining reference stator voltage vector in generating PWM output voltage for induction motors. The objective is to reduce electromagnetic torque ripple and stator flux droop which result in a decrease in current distortion in steady state condition. In addition, the proposed technique provides simplicity of a control system. The direct torque control is based on the relationship between instantaneous slip angular frequency and rotor angular frequency in adjustment of the reference stator flux angle. The amplitude of the reference stator flux is always kept constant at rated value. Experimental results are illustrated in this paper confirming the capability of the proposed system in regards to such issues as torque and stator flux response, stator phase current distortion both in dynamic and steady state with load variation, and low speed operation.

부하 주파수 제어를 위한 퍼지 로직 기반 확장 적분 제어 (Fuzzy Logic Based Extended Integral Control for Load Frequency Control)

  • 류헌수;이종기;김석주;김백;문영현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.210-213
    • /
    • 2001
  • This study presents an effective variable forgetting factor method based on fuzzy logic to suppress frequency droop in extended integral load frequency control. The performance of the extended integral control is greatly dependent on the decaying factor. For an optimal or near optimal performance, it is necessary that the decaying factor as well as the feedback gains should be changed very quickly in response to changes in the system dynamics. However, because of its time-varing characteristic, the optimal decaying factor is difficult to be selected analytically. By adopting fuzzy set theory, the decaying factor can be determined quickly to respond to the variation of the feedback signals. This study builds a fuzzy rule base with use of the change of frequency and its rate as inputs. The computer simulation has been conducted for the single machine system. The simulation results show that the proposed fuzzy 1o81c based controller yields more improved control performance than the conventional PI controller.

  • PDF

IFOP를 사용한 효과적인 DFDC 필터 설계 (Efficient DFDC Filter Design Using Interpolated Fourth-Order Polynomials)

  • 양세정;장영범
    • 한국통신학회논문지
    • /
    • 제28권6C호
    • /
    • pp.609-614
    • /
    • 2003
  • 이 논문에서는 CIC(Cascaded Integrator-Comb) 데시메이션 필터의 주파수응답을 향상시키는 새로운 필터 구조를 제안한다. 기존의 방식은 CIC 필터의 통과대역 특성은 향상시키나, Aliasing 대역의 감쇠특성은 조금 나빠지는 단점을 갖고 있다. 그러나 이 논문에서는 통과대역의 특성은 기존의 방식보다 우수하며, 동시에 Aliasing 대역의 감쇠특성도 매우 향상시키는 IFOP(Interpolated Fourth-Order Polynomials) 필터를 제안한다. 제안된 필터는 4차의 필터이나 곱셈이 1개만 필요한 구조이므로 부가적인 연산량이 적으며, 또한 선형위상의 특성을 갖고 있으므로 CIC 필터의 선형위상 특성을 그대로 유지할 수 있다. 또한 기존의 주파수응답 향상 기법들과 제안된 필터의 구현비용을 비교하였다.

직류 마이크로그리드의 전력 공유 정확도 및 전압 제어 성능 향상을 위한 전압 민감도 행렬 기반의 분산 제어 방법 (A Distributed Control Method based on Voltage Sensitivity Matrix in DC Microgrids for Improvement of Power Sharing Accuracy and Voltage Regulation Performance)

  • 이기영;고병선;이재석;김래영
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.345-351
    • /
    • 2018
  • A distributed control method is proposed to improve the power sharing performance of bidirectional distributed generators and the voltage regulation performance of a DC bus in a DC microgrid. Voltage sensitivity analysis based on power flow analysis is conducted to analyze the structural characteristics of a DC microgrid. A distributed control method using a voltage sensitivity matrix is proposed on the basis of this analysis. The proposed method uses information received through the communication system and performs the droop gain variation method and voltage shift method without additional PI controllers. This approach achieves improved power sharing and voltage regulation performance without output transient states. The proposed method is implemented through a laboratory-scaled experimental system consisting of two bidirectional distributed generators, namely, a load and a non-dispatchable distributed generator in a four-bus ring-type model. The experimental results show improved power sharing accuracy and voltage regulation performance.

선박발전기용 디지털 AVR 개발 (Development of the Digital AVR for Ship Generator)

  • 김태완;김승환;이수병;송석현;이선재;김명찬;이상동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.828-830
    • /
    • 2003
  • AVR은 동기발전기의 출력전압을 부하변동에 관계없이 일정하게 제어하며 발전기 및 시스템 보호를 위한 각 종 제어 알고리즘을 구비하고 있다. 종래의 아나로그타입 AVR은 제어설정이 불편하고 제어신뢰성이 떨어지기 때문에 점차 디지털 타입으로 교체되고 있다. 본 연구는 선박발전기에 적용하기 위한 디지털 AVR 개발에 관한 것이다. TI사의 TMS320LF2407 CPU를 사용하여 제어 H/W를 개발했으며, 과여자/저여자제어, Droop제어, 무부하/역률제어 등 다양한 제어기능을 S/W로 구비하여 부하에 따른 적용의 유연성을 높였다. 그리고 전력회로는 IGBT를 사용하여 고속 스위칭 제어함으로써 SCR 방식에 비해 제어 속응성을 개선하였다. 개발 된 제품은 AVR, 직류전원공급장치 및 부하나 계통의 사고시 보호를 위한 전류부스트(CBS)기능을 포함하고 있다.

  • PDF

기능적 Brassiere개발에 관한 연구 I- 착용실태 조사를 중심으로 - (Status quo Study on the Functional Brassiere Development)

  • 최혜선;강여선
    • 한국의류학회지
    • /
    • 제15권2호
    • /
    • pp.189-198
    • /
    • 1991
  • The object of this study is to perceive the discomforts of the brassiere consumers according to their age groups & weight groups. The study procedures consisted of a status quo study, a rating on fit and performance according to brassiere types. 1. The result of the status quo study are as follows. (1) The study showed that with getting age bust circumference and bust size become larger with a bigger tendency to droop. Thus older age, bigger bust circumference and size require a technically improved version of brassieres. (2) Slightly tight fit brassieres were favored over more ample ones. The hobbling areas were center front, under armpits, and shoulder strapareas in that order. 2. The results of fit rating on different brassiere types are as follows. (1) The areas affected by brassiere performance were length from side neck point to bust point (bust length), width between bust points and bust height. (2) Compared among brassiere types, the wire type proved most effective. The bigger cup size group had higher satisfactory rate and low discomfort on wearing.

  • PDF