• Title/Summary/Keyword: droop

Search Result 204, Processing Time 0.031 seconds

Parallel Operation Control Method of PCS Module for ESS (ESS용 PCS 모듈의 병렬운전 제어)

  • Bae, Ki-Hoon;Kim, Jun-Mo;Lee, Jeong;Eom, Tae-Ho;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.141-142
    • /
    • 2018
  • 본 논문에서는 부하 분담, 신뢰성 및 효율 향상, 시스템 용량을 증가시키는 PCS 모듈 병렬 운전 방법을 제안한다. 병렬 운전을 할 때 모듈별 출력 전압, 전류 값들이 이상적으로 동일하지 않기 때문에 시스템 손실을 초래하는 순환전류가 필연적으로 발생하게 된다. 따라서 순환전류를 저감시키기 위해 모듈별 전력제어와 가상의 계수인 droop index를 이용하여 Load sharing이 잘 되는 제어 알고리즘을 이용하여 병렬 운전 방법의 타당성을 검증한다.

  • PDF

Design and Fabrication of S-Band GaN SSPA for a Radar (레이더용 S대역 GaN 반도체 전력증폭기 설계 및 제작)

  • Lee, Jeong-Won;Lim, Jae-Hwan;Kang, Myoung-Il;Han, Jae-Seob;Kim, Jong-Pil;Lee, Sue-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1139-1147
    • /
    • 2011
  • In this paper, a design and fabrication of GaN power amplifier for the S-band frequency (400 MHz bandwidth) are presented. A combining path using ${\lambda}$/4 transmission line is implemented for GaN pallet amp. Both the combiner with suspended-type transmission structure for low-loss and the suspended stripline coupler with aperture coupling for auto gain control are realized for achieving high-power high-efficiency amplifier. Proposed power amplifier demonstrated a 5 kW peak output power, 27.8 % efficiency, 67 dB gain without ALC and a 4 kW peak output power, 25.5 % efficiency, 0.1 dB droop at 200 usec pulse width and 10 % duty with ALC.

Analysis on Lower Half Shapes of Middle Aged Women (중년여성 하반신의 유형분석)

  • 임희경;문명옥
    • Journal of the Korean Society of Costume
    • /
    • v.40
    • /
    • pp.95-107
    • /
    • 1998
  • The purpose of this research paper is to offer basic data for cloth design which is intended to apply appropriate shape and catacity to cloth. Followings are the analyzed result of investigation which was conducted to figure out the character of middle aged from 35 to 59 years old-women body especially in lower half of their body. 177 women took part in this investigation. 1. As a result of analyzed characters for middle aged women body shape, taking a side view of body, there are great variance in thickness coefficient which indicates the size of body. 2. According to a comparison result of early middle aged women body shape with late middle aged women body shape, the value in height items get shorter otherwise the value in thickness items get longer getting older. It means late middle aged women are relatively fat. 3. For the analysis of women body especially in lower half, 8 factors were used. They are as followings. Factor 1. Side thickness of lower half. Factor 2. Width of lower half. Factor 3. Height of lower half Factor 4. Droop of underbelly Factor 5. Salient rate of buttocks. Factor 6. Length of buttocks. Factor 7. Salient rate of underbelly. Factor 8. Droop of buttocks 4. Lower half shapes of middle aged women were divided into three groups and the character of each group are as followings. 〈Group 1〉65.0% of women who took part in this investigation have this type of body shape. They have long value in height items and thickness items. 〈Group 2〉16.4% of women who take part in this investigation were belonged to this group. The value in height items were not so different from group 1 but the thickness value are shorter than group 1. Women of group 2 have slime body shape. 〈Group 3〉18.6% of women were belonged to group 3. They show the shortest value in height items otherwise the longest value in thickness items. Therefore they are the smallest and the fattest group in this investigation.

  • PDF

Design Optimization of High-Voltage Pulse Transformer for High-Power Pulsed Application (고출력 펄스응용을 위한 고전압 펄스변압기 최적설계)

  • Jang, S.D.;Kang, H.S.;Park, S.J.;Han, Y.J.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1297-1300
    • /
    • 2008
  • A conventional linear accelerator system requires a flat-topped pulse with less than ${\pm}$ 0.5% ripple to meet the beam energy spread requirements and to improve pulse efficiency of RF systems. A pulse transformer is one of main determinants on the output pulse voltage shape. The pulse transformer was investigated and analyzed with the pulse response characteristics using a simplified equivalent circuit model. The damping factor ${\sigma}$ must be >0.86 to limit the overshoot to less than 0.5% during the flat-top phase. The low leakage inductance and distributed capacitance are often limiting factors to obtain a fast rise time. These parameters are largely controlled by the physical geometry and winding configuration of the transformer. A rise time can be improved by reducing the number of turns, but it produces larger pulse droop and requires a larger core size. By tradeoffs among these parameters, the high-voltage pulse transformer with a pulse width of 10 ${\mu}s$, a rise time of 0.84 ${\mu}s$, and a pulse droop of 2.9% has been designed and fabricated to drive a klystron which has an output voltage of 284 kV, 30-MW peak and 60-kW average RF output power. This paper describes design optimization of a high-voltage pulse transformer for high-power pulsed applications. The experimental results were analyzed and compared with the design. The design and optimal tuning parameter of the system was identified using the model simulation.

  • PDF

Design and Fabrication of X-Band 50 W Pulsed SSPA Using Pulse Modulation and Power Supply Switching Method (펄스 변조 및 전원 스위칭 방법을 혼용한 X-대역 50 W Pulsed SSPA 설계 및 제작)

  • Kim, Hyo-Jong;Yoon, Myoung-Han;Chang, Pil-Sik;Kim, Wan-Sik;Lee, Jong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.440-446
    • /
    • 2011
  • In this paper, a X-band 50 W pulsed solid state power amplifier(SSPA) is designed and fabricated for radar systems. The SSPA consists of a driver amplifier, a high power amplifier, and a pulse modulator. The high power stage employes four 25 W GaAs FET to deliver 50 W at X-band. To meet the stringent target specification for the SSPA, we used a new hybrid pulse switching method, which combine the advantage of pulse modulation and bias switching method. The fabricated SSPA shows a power gain of 44.2 dB, an output power of 50 W over a 1.12 GHz bandwidth. Also, pulse droop < 1 dB meet the design goals and a rise/fall time is less than 12.45 ns. Fabricated X-band pulsed SSPA size is compact with overall size of $150{\times}105{\times}30\;mm^3$.

A simulation module to practice hydraulic mechanical governors and its adjustment characteristics for stability (유압기계식 거버너의 실습용 시뮬레이션 모듈과 안정도의 조정 특성)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.533-540
    • /
    • 2013
  • Prime movers in engine rooms inherently are much affected by the adjustment of their governors for the steady state and transient properties, consequently requiring that marine engineers shall be well familiar with the way to manage governor dials for normal operation. The hydro-mechanical governors basically have different control characteristics and adjustment parameters of stability from digital governors. The former include compensation mechanism using dash pot while the control algorithm of the latter is usually based on the PID action. This study is for configuring a simulation module to let trainees practice how to adjust dials for stability on hydraulic governors in the view that the practice by real governors and engines is time consuming and high cost for operation. The governor module includes the adjusting points such as speed set, speed droop, needle valve and compensation pointer with engine module of $2^{nd}$ order coupled. The results of simulation showed satisfactory responses as a training tool for the adjustment of control parameters.

High Performance GaN-Based Light-Emitting Diodes by Increased Hole Concentration Via Graphene Oxide Sheets

  • Jeong, Hyun;Jeong, Seung Yol;Jeong, Hyun Joon;Park, Doo Jae;Kim, Yong Hwan;Kim, HyoJung;Lee, Geon-Woong;Jeong, Mun Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.244.1-244.1
    • /
    • 2013
  • The p-type GaN which act as a hole injection layer in GaN-based LEDs has fundamental problems. The first one arises from the difficulty in growing a highly doped p-GaN (with a carrier concentration exceeding ~1018 $cm^{-3}$). And the second one is the absence of appropriate metals or conducting oxides having a work function that is larger than that of p-type GaN (7.5 eV). Moreover, the LED efficiency is decreases gradually as the injection current increases (the so-called 'efficiency droop' phenomenon). The efficiency droop phenomenon in InGaN quantum wells (QWs) has been a large obstacle that has hindered high-efficiency operation at high current density. In this study, we introduce the new approaches to improve the light-output power of LEDs by using graphene oxide sheets. Graphene oxide has many functional groups such as the oxygen epoxide, the hydroxyl, and the carboxyl groups. Due to nature of such functional groups, graphene oxide possess a lot of hole carriers. If graphene oxide combine with LED top surface, graphene oxide may supply hole carriers to p-type GaN layer which has relatively low free carrier concentration less than electron concentration in n-type GaN layer. To prove the enhancement factor of graphene oxide coated LEDs, we have investigated electrical and optical properties by using ultra-violet photo-excited spectroscopy, confocal scanning electroluminescence microscopy.

  • PDF

Power Sharing Method for a Grid connected Microgrid with Multiple Distributed Generators

  • Nguyen, Khanh-Loc;Won, Dong-Jun;Ahn, Seon-Ju;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.459-467
    • /
    • 2012
  • In this paper, a grid connected microgrid with multiple inverter-based distributed generators (DGs) is considered. DG in FFC mode regulates the microgrid as a controllable load from the utility point of view as long as its output is within the capacity limit. The transition mode causes a change in frequency of microgrid due to the loss of power transferred between main grid and microgrid. Frequency deviation from the nominal value can exceed the limit if the loss of power is large enough. This paper presents a coordinated control method for inverter-based DGs so that the microgrid is always regulated as a constant load from the utility viewpoint during grid connected mode, and the frequency deviation in the transition mode is minimized. DGs can share the load by changing their control modes between UPC and FFC and stabilize microgrid during transition.

Virtual impedance based droop control for proper power sharing of parallel inverters in islanded microgrid (마이크로그리드 독립운전 시 병렬 운전 인버터의 적절한 전력분담을 위한 가상임피던스 기반의 드룹제어 연구)

  • ko, Seungwoo;Lim, Kyungbae;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.125-126
    • /
    • 2016
  • 여러 분산 발전 시스템으로 구성된 마이크로그리드는 계통연계 모드에서 부하의 수요에 담당하게 되고, 계통 사고가 발생할 시 독립 운전 모드로 동작을 해야 한다. 본 논문에서는 독립운전 모드 동작 시 제어 방식 중에서 유, 무효 전력제어를 통한 적절한 전력 분담을 실현하기 위한 드룹제어 방식을 다룬다. 이 방식은 선로 임피던스가 복합 성분으로 구성되어 있거나 불 평형 일 경우 여러 문제로 유,무효 전력 분담의 오차를 발생 시킨다. 이에 대하여 가상임피던스를 추가함으로써, 복합적 불 평형 임피던스에 기인한 유,무효 전력 분담의 오차를 해결 하여, 시스템의 유,무효 전력 분담을 개선 하고자 하였다. 가상 임피던스에 따른 출력 임피던스에 대해서 연구하고 이에 따른 드룹제어를 분석하고, PSIM 시뮬레이션을 이용하여 검증하였다.

  • PDF

Performance prediction of mixed-flow pumps (혼류 펌프의 성능 해석)

  • O, Hyeong-U;Yun, Ui-Su;Jeong, Myeong-Gyun;Ha, Jin-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.1
    • /
    • pp.70-78
    • /
    • 1998
  • The present study has tested semi-empirical loss models for a reliable performance prediction of mixed-flow pumps with four different specific speeds. In order to improve the predictive capabilities, this paper recommends a new internal loss model and a modified parasitic loss model. The prediction method presented here is also compared with that based on two-dimensional cascade theory. Predicted performance curves by the proposed set of loss models agree fairly well with experimental data for a variety of mixed-flow pumps in the normal operating range, but further studies considering 'droop-like' head performance characteristic due to flow reversal in mixed-flow impellers at low flow range near shut-off head are needed.