• 제목/요약/키워드: drinking water distribution pipe

검색결과 39건 처리시간 0.02초

단방향 플러싱에 의한 입자성 물질의 제거에 관한 연구 (A study on the removal of particulate matters using unidirectional flushing)

  • 김두일;천수빈;현인환
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.371-380
    • /
    • 2015
  • Particulate matters in a water distribution system are main causes of turbidity and discoloration of tap water. They could be removed by conventional or uni-directional flushing in a water distribution system. The behaviors and required flow velocity of particles are not well known for their flushing. A model water main and hydrant were made from transparent acrylic pipe of 30mm and 16mm in diameter, respectively. We analyzed the effect of flushing velocity, particle density, and particle diameter. We found that the existence of break-though velocities at which particles begin to be removed, and which are affected by their physical properties. The removal efficiencies seemed to be influenced by resuspension capabilities related to their upward movement from the bottom. Heavy particles like scale were hard to remove through upflow hydrant because the falling velocity, calculated using Stokes' law, was higher. Particle removal efficiencies of upward hydrant and downward drain showed minor differences. Additionally, the length between hydrant and control valve affected flushing efficiency because the particulate matters were trapped in this space by inertia and recirculating flow.

Effect of Distribution System Materials and Water Quality on Heterotrophic Plate Counts and Biofilm Proliferation

  • 장영철;정권
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권6호
    • /
    • pp.1114-1119
    • /
    • 2004
  • The biofilms on pipe walls in water distribution systems are of interest since they can lead to chlorine demand, coliform growth, pipe corrosion, and water taste and odor problems. As such, the study described in this paper is part of an AWWARF and Tampa Bay Water tailored collaboration project to determine the effect of blending different source waters on the water quality in various distribution systems. The project was based on 18 independent pilot distribution systems (PDS), each being fed by a different water blend (7 finished waters blended in different proportions). The source waters compared were groundwater, surface water, and brackish water, which were treated in a variety of pilot distribution systems, including reverse osmosis (RO) (desalination), both membrane and chemical softening, and ozonation-biological activated carbon (BAC), resulting in a total of 7 different finished waters. The observations from this study consistently demonstrated that unlined ductile iron was more heavily colonized by a biomass than galvanized steel, lined ductile iron, and PVC (in that order) and that the fixed biomass accumulation was more influenced by the nature of the supporting material than by the water quality (including the secondary residual levels). However, although the bulk liquid water cultivable bacterial counts (i.e. heterotrophic plate counts or HPCs) did not increase with a greater biofilm accumulation, the results also suggested that high HPCs corresponded to a low disinfectant residual more than a high biofilm inventory. Furthermore, temperature was found to affect the biofilms, plus the AOC was important when the residual was between 0.6 and 2.0 mg $Cl_2/l$. An additional aspect of the current study was that the potential of the exoproteolytic activity (PEPA) technique was used along with a traditional so-called destructive technique in which the biofilm was scrapped off the coupon surface, resuspended, and cultivated on an R2A agar. Both techniques indicated similar trends and relative comparisons among the PDSs, yet the culturable biofilm values for the traditional method were several orders of magnitude lower than the PEPA values.

태백권 배수관망 개량사업의 비용효과분석 최적화 모델 연구 (A Study on Cost Benefit Analysis Optimization Model for Water Distribution Network Rehabilitation Project of Taebaek Region)

  • 김태곤;최태호;김경필;구자용
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.395-406
    • /
    • 2015
  • This research carried out an analysis on input cost and leakage reduction effect by leakage reduction method, focusing on the project for establishing an optimal water pipe network management system in the Taebaek region, which has been executed annually since 2009. Based on the result, optimal cost-benefit analysis models for water distribution network rehabilitation project were developed using DEA(data envelopment analysis) and multiple regression analysis, which have been widely utilized for efficiency analysis in public and other projects. DEA and multiple regression analysis were carried out by applying 4 analytical methods involving different ratios and costs. The result showed that the models involving the analytical methods 2 and 4 were of low significance (which therefore were excluded), and only the models involving the analytical methods 1 and 3 were suitable. From the result it was judged that the leakage management method to be executed with the highest priority for the improvement of revenue water ratio was installation of pressure reduction valve, followed by replacement of water distribution pipe, replacement of water supply pipe, and then leakage detection and repair; and that the execution of leakage management methods in this order would be most economical. In addition, replacement of water meter was also shown to be necessary in case there were a large number of defective water meters.

상수도 잔류염소농도 균등화를 위한 반응계수 추정 및 염소 재투입 최적화 (Reaction coefficient assessment and rechlorination optimization for chlorine residual equalization in water distribution networks)

  • 정기문;강두선;황태문
    • 한국수자원학회논문집
    • /
    • 제55권spc1호
    • /
    • pp.1197-1210
    • /
    • 2022
  • 최근 국내에서는 관로 노후화 및 다양한 수질사고 발생으로 인해 상수도 분야에 대한 관심이 급증함에 따라, 상수도 서비스에 대한 이용자들의 수질민원 또한 증가하고 있다. 수질민원의 경우 실제 수질오염뿐만 아니라 소독을 위한 잔류염소농도에 대한 불편을 포함하고 있으며, 따라서 사용자에게 공급되는 잔류염소농도를 균등하게 유지하기 위해 재염소 처리와 같은 다양한 노력이 시도되고 있다. 본 연구에서는 상수관망 내 잔류염소농도 모의를 위해 적용 대상지역의 수질반응계수를 추정하였으며, 수질기준을 만족시키는 동시에 잔류염소농도 균등화를 고려하기 위한 염소 투입 및 재투입 최적화 방법을 제안하였다. 제안된 방법은 국내 대규모 지방상수도를 대상으로 적용하였으며, 격자탐색법을 통해 다양한 염소 투입/재투입 계획을 비교 분석하고, 공급 잔류염소농도의 적합성 및 균등성을 중심으로 최적화한 결과를 제시하였다.

수돗물의 앙금발생규명 및 저감기술방안 (Study on the alternatives to trace the origin and to diminish the sediments of drinking water)

  • 김갑수;임병진;권은미
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.17-28
    • /
    • 1994
  • There are many possibilities that may lead to low quality of drinking water Recently, some unknown deposits in tap water raised a lot of public concern regarding the safety of drinking water in Seoul. We analyzed the quality of tap water from several areas of Seoul, including the area where public complaints about tap water were high. The results shows that the quality of tap water in Seoul was good, well below the environmental standards. Only the tap water from the area with high public complaints showed turbidity higher than that of other area. Also, result shows that component of deposit in tap water was Al, Fe, Mn, and Zn. Based on the research result we propose several measures that might help to reduce the amount of deposit in tap water as follows : 1 Using coagulant aid when coagulating or adjusting pH when filtering. 2. Replacing old water pipeline with new corrosive- resistant one. 3. Increasing water treatment efficiency by enhancing water treatment system such as automation of water treatment system adjusting production capacity, and improving operational condition of filler basin. 4. Chlorine disinfection at the distribution reservoir would help maintaining the same pH level and chlorine concentration throughout the water pipeline and reduce corrosion of pipe.

  • PDF

Effects of Diverse Water Pipe Materials on Bacterial Communities and Water Quality in the Annular Reactor

  • Jang, Hyun-Jung;Choi, Young-June;Ka, Jong-Ok
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권2호
    • /
    • pp.115-123
    • /
    • 2011
  • To investigate the effects of pipe materials on biofilm accumulation and water quality, an annular reactor with the sample coupons of four pipe materials (steel, copper, stainless steel, and polyvinyl chloride) was operated under hydraulic conditions similar to a real plumbing system for 15 months. The bacterial concentrations were substantially increased in the steel and copper reactors with progression of corrosion, whereas those in stainless steel (STS) and polyvinyl chloride (PVC) reactors were affected mainly by water temperature. The heterotrophic plate count (HPC) of biofilms was about 100 times higher on steel pipe than other pipes throughout the experiment, with the STS pipe showing the lowest bacterial number at the end of the operation. Analysis of the 16S rDNA sequences of 176 cultivated isolates revealed that 66.5% was Proteobacteria and the others included unclassified bacteria, Actinobacteria, and Bacilli. Regardless of the pipe materials, Sphingomonas was the predominant species in all biofilms. PCR-DGGE analysis showed that steel pipe exhibited the highest bacterial diversity among the metallic pipes, and the DGGE profile of biofilm on PVC showed three additional bands not detected from the profiles of the metallic materials. Environmental scanning electron microscopy showed that corrosion level and biofilm accumulation were the least in the STS coupon. These results suggest that the STS pipe is the best material for plumbing systems in terms of the microbiological aspects of water quality.

배수관 플러싱의 수리적 현상과 배출수의 수질 특성 (Hydraulics and water quality characteristics of flushing in distribution pipes)

  • 안재찬;이수원;백광인;최영준;최재호;정의선;박현;구자용
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.93-103
    • /
    • 2008
  • This study was conducted to optimize a unidirectional flushing program in distribution pipes by analysis of water pressure, velocity, quality, and other parameters during flushing. As a result, correlation coefficient between flushed pipe length and the flushing duration was obtained $R^2=0.83$ and the equation $Y_{Time}=0.0571{\cdot}X_{Pipe\;length}+4.7648$ for 10 pipes. The averaged flushing velocity in the pipes, 1.1 m/s, was enough to remove loose deposits on the inner wall of the pipes. 3 of 92 water samples taken during flushing met the National Drinking Water Quality Standard for Fe and Mn, but not for Al. Turbidity less than 1 NTU is suggested for the appropriate criteria to finish flushing in pipes. The coefficient of determination ($R^2$) between turbidity and TSS was 0.95 and the equation was induced as $Y_{TSS}=1.2068{\cdot}X_{Turbidity}$. The amount of removed deposits could be estimated from the turbidity data of discharged water in field because turbidity and TSS in the discharged water is highly correlated.

수돗물중 소독부산물(DBPs)의 생성 및 분포특성에 관한 연구 (Occurrence and Distribution of Disinfection of By-Products in Drinking Water)

  • 인치경;이중호;이인숙;방은옥;송현실;윤선진
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.263-272
    • /
    • 2005
  • Chlorine disinfection has been used in drinking water supply to disinfect the water-borne microbial disease which may cause to serious human disease. it is still the least costly, relatively easy to use, Chlorination is the primary means to disinfect portable water supplies and control bacterial growth in the distribution system. However, chlorine reacts with natural organic matter(NOM), that presents in nearly all water sources, and then produces disinfection by-products(DBPs), that have adverse health effects. Although the existent DBPs have been reported in drinking water supplies, it is not feasible to predict the levels of the various DBPs due to the complex chemistry reaction involved. 1. The objectives of this study is to investigate seasonal variation difference concentration of DBPs in the plant to tap water. The average concentration of THMs was 20.04 ${\mu}g/{\ell}$ , HAAs 8-15 ${\mu}g/{\ell}$ , HANs 2-4.5 ${\mu}g/{\ell}$ respectively. 2. Distant variation of DBPs furmation by the distance is that THMs concentration increased by 17% at 2km point from the plant and by 28% at 7km and HAAs, HANs also increase each by 16%, 32% at 2 km from the plant and 35%, 56% at 7 km. DBPs increase in water supply pipe continually, 3. The seasonal occurrence of BBPs is that in May and August DBPs concentration is very higher than in march, in May DBPs concentration is highest. The temperature is main factor of DBPs formation, precursor also. 4. Precursor which was accumulated for winter flowed into the raw water by flooding in spring and summer and produced DBPs. 5. Therefore for the supply of secure drinking water, it is required to protect precursor of flowing into raw water and to add to BCAA and DBAA to drinking water standards.

  • PDF

상수도관망에서 입자성 물질의 특성분석 및 영향조사 (Characteristic Analysis and Effect of Particulate Material in Drinking Water Distribution Networks)

  • 김도환;이두진;황진수;최두용
    • 대한환경공학회지
    • /
    • 제35권5호
    • /
    • pp.312-320
    • /
    • 2013
  • 상수도관망에서의 입자성 물질들은 대부분 금속관로의 내부부식 및 퇴적물에 의한 영향으로 이를 해결할 수 있는 방법은 제한적이라 할 수 있다. 수중의 입자성 물질들은 입자크기, 화합물 성분 및 성상들이 다르며, 이들 특성은 시설별 종류, 관 상태, 외부적 요인 및 공급과정 등에 의해서 차이가 발생하게 된다. 본 연구에서는 상수도관망의 수질조사를 수행하면서 수중의 입자성 물질들에 대한 조사를 실시하고자 하였으며, 정수를 공급하는 각 계통들의 배수지 및 관말지역을 대상으로 실시하였다. 각 조사지점에서 입자성 물질을 포집하기 위해 $47{\phi}$ 의 유리섬유여지(GF/C)를 이용하여 여과를 수행하였다. 수중의 탁도에 영향을 미치는 물질들이 입자성 부유물질과 무기물질들에 의한 것으로 관말지역으로 갈수록 입자성 물질이 증가하는 것으로 조사되었다. XRD를 이용한 입자성 물질의 화합물 성분분석결과 상수도관망의 관말지역에서 가장 많은 화합물은 Goethite (${\alpha}$-FeOOH), Magnetite ($Fe_3O_4$) 등이고 정수와 각 배수지 유출수에서는 Quartz ($SiO_2$)와 Yeelimite ($Ca_4Al_6O_{12}SO_4$) 등도 있는 것으로 조사되어 각 상수도 시설별 용출되거나 잔존하고 있는 화합물 성분이 다르며, 침적물들에도 차이가 있었다.

부식 생성물 분석법을 이용한 상수도 금속관의 부식거동에 관한 연구 (Study of Drinking water pipeline Corrosion Mechanism by using Scale Analysis)

  • 황상용;송호봉
    • 환경위생공학
    • /
    • 제17권1호
    • /
    • pp.57-62
    • /
    • 2002
  • Carbon cast iron and Zinc coated steel were the most widely used portable water of supply and distribution Pipeline system. The leaching of red water in portable water could produce sericus environmental sanitary problems. Due to the red water was the most alternative to inner scale of metal pipeline. So this study was conducted the impact of red water on scale products, and was evaluated by the corrosive metal contaminants of 20 fears over. Surface tests, metal surface composition measurements of samples XRF, XRD, and SEM(EDS), analysis were used to investigate the corrosion characteristies of carbon cast iron and Zinc coated steel. As the contaminants of Fe increased the red water of carbon castiron pipe increased due to the scale products amount of $Fe_2O_3$ (Hemite).