• Title/Summary/Keyword: drift ratio

Search Result 373, Processing Time 0.022 seconds

System Performance Improvement of IEEE 802.15.3a By Using Time Slot Synchronization In MAC Layer (UWB MAC의 Time Slot 동기를 통한 시스템 성능 개선)

  • Oh Dae-Gun;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.3 s.345
    • /
    • pp.84-94
    • /
    • 2006
  • In this paper, we propose the algorithm to reduce guard time of UWB MAC time slot for throughput gain. In the proposed draft by multiband ofdm alliance (MBOA), Guard time of each medium access slot (MAS) is composed of shortest inter-frame space (SIFS) and MaxDrift which is the time caused by maximum frequency offset among devices. In this paper, to reduceguard time means that we nearly eliminate MaxDrift term from guard time. Each device of a piconet computes relative frequency offset from the device initiating piconet using periodically consecutive transferred beacon frames. Each device add or subtract the calculated relative frequency offset to the estimated each MAS starting point in order to synchronize with calculated MAS starting point of the device initiating piconet. According to verification of simulations, if the frequency offset estimator is implemented with 8 decimal bit, the ratio of the wasted time to Superframe is always less than 0.0001.

Shearing Strength Properties of Bolted, Drift-Pinned Joints of the Larix Glulam - Effects of Fastener Diameter, Slenderness and End-distance on Strength Properties - (낙엽송 집성재의 Bolt, Drift Pin 접합부의 전단강도 성능 평가 - 접합구 직경, 세장비, 끝면거리가 강도에 미치는 영향 -)

  • Kim, Keon-Ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.69-78
    • /
    • 2008
  • Shearing strength test in tension type was investigated to determine the shear resistance of bolt and drift-pin connection of domestic larix glulam. The specimen was connected with bolt and drift-pin in the inserted plate type, and only bolt in the side plate type. The diameter of bolt and drift-pin used in the experiment are 12, 16 and 20 mm. The hole of bolt was drilled at the end-distance 5 d and 7 d. Tension load was loaded in the direction parallel to grain. The shear resistance was evaluated according to end-distance through this, the yield load was compared with the experimental yield load, using Larsen's formula. The prototype design strength is based on the yield load of end-distance 7 d and the reduction factor of end-distance 5 d was calculated. The results were as follows. 1. The average of maximum load of drift-pin connection was higher by 3~30% at the inserted type than at bolt connection with increasing diameter. In bolt connection, the average of maximum load of the side type was 1.54~2.07 times higher than that of the inserted type. In the same diameter, the average of maximum load of end-distance 7 d was higher by 8~44% than that of 5 d. 2. The bearing stress was 1.16~1.41 times higher at the inserted connection than at drift-pin connection, and 1.37~1.86 times higher at 7 d than at 5 d. Also, when the slenderness ratio was below 7.5 at drift-pin connection and below 6.0 at inserted connection, the lateral capacity was good. 3. The ratio of the experimental yield load and the predicted yield load calculated by Larsen's formula proposed by Larsen was 0.80~1.10 at inserted connection, and 0.75~1.46 at side connection. 4. When the inserted bolt connection was based on the yield load of end-distance 7 d, the reduction factor was 0.89 at 12 mm connection, 0.93 at 16 mm and 0.85 at 20 mm. The reduction factor was 0.89 at 12 mm the inserted drift-pin connection, 0.93 at 16 mm, 0.93 at 20 mm. The reduction factor was 0.79 at the side connection of the 12 mm bolt connection and 0.80 at 16 mm.

Seismic Performance of Square RC Column Confined with Spirals (나선철근으로 횡구속된 정사각형 RC 기둥의 내진성능)

  • Ko, Seong Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.88-97
    • /
    • 2012
  • The objective of this research is to investigate the seismic performance and flexure-shear behavior of square reinforced concrete bridge piers with solid and hollow cross section. Test specimens were nonseismically designed with the aspect ratio 4.5 Two reinforced concrete columns were tested under constant axial load while subjected to lateral load reversals with increasing drift levels. Longitudinal steel ratio was 2.217 percent. The transverse reinforcement ratio As/($s{\cdot}h$), corresponding to 58 percent of the minimum lateral reinforcement required by Korean Bridge Design Specifications for seismic detailing, which represent existing columns not designed by the current seismic design specifications or designed by limited ductility concept. This study are to provide quantitative reference data for the limited ductility design concept and tendency for performance or damage assessment based on the performance levels such as cracking, yielding, collapse, etc. Failure behavior, ultimate displacement/drift ratio, displacement ductility, response modification factor, equivalent viscous damping ratio, residual deformation, effective stiffness, plastic hinge length, strain of reinforcements and nonlinear analysis are investigated and discussed in this paper.

The Nonlinear Behavior Characteristics of the 3D Mixed Building Structures with Variations in the Lower Stories (입체 복합구조물의 하부골조 층수 변화에 따른 비선형 거동특성)

  • 강병두;전대한;김재웅
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.55-62
    • /
    • 2002
  • The upper wall-lower frame structures(mixed building structures) are usually composed of shear wall structure in the upper part of structure which is used as residential space and frame structure in the lower part of structure which is used as commercial space centering around the transfer system in the lower part of structure. These structures are characteristics of stiffness irregularity, mass irregularity, and vertical geometric irregularity. The purpose of this study is to investigate the nonlinear response characteristics and the seismic capacity of mixed building structures when the number of stories in the lower frame is varied. The conclusions of this study are following. 1) As the result of push-over analysis of structure such as roof drift(i.e. roof displacement/structural height) and base shear coefficient, when the stories of lower frame system are increased, base shear coefficient is decreased, but roof drift is increased. 2) According to an increase in stories of the lower fame, story drift and ductility ratio of upper wall system are decreased and behavior of upper wall system is closed to elastic. 3) When the stories of lower frame system are increased, the excessive story drift is concentrated on the lower frame system.

Seismic Performance Evaluation of Post-Northridge WUF-B Connections Frame (Post-Northridge WUF-B 접합부 골조의 내진 성능 평가)

  • Han, Sang Whan;Moon, Ki Hoon;Jung, Ji Eun;Lee, Ki Hak
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.751-760
    • /
    • 2007
  • The purpose of this study is to evaluate the seismic performance of the frame which is assumed to be used with Welded Unreinforced Flange-Bolted web (WUF-B) connections and detailed in compliance with FEMA 350 recommended seismic design criteria. In FEMA 350, these types of connections are only valid for Ordinary Moment-Resisting Steel Frames (OMRSFs). For this purpose, based on test results, we proposed an analytical model for the Post-Northridge WUF-B connections with different panel zone strength ratios. Using the connection model, SAC Phase II three and nine-story frames were modeled and analyzed. From a nonlinear static pushover analysis, ductility, maximum strength, and the maximum interstory drift ratio were investigated for buildings with Post-Northridge details. Moreover, the maximum interstory drift ratio of each performance level (IO and CP) was also investigated through Incremental Dynamic Analysis (IDA). Analytical results were compared with those of buildings with either Pre-Northridge connection or ductile connections with no fracture. The analytical results showed that buildings with Post-Northridge WUF-B connections provide superior strength and interstory drift ratio capacity than buildings with Pre-Northridge WUF-B connections.

Ecotoxicological Study of Gammarus sobaegensis by pH Depression in Artificial Channels - Drift behavior - (인공수로에서 산성화 영향에 따른 소백옆새우(Gammarus sobaegensis)의 생태독성학적 연구 - 표류행동을 중심으로 -)

  • Park, Jung-Ho;Cho, Dong-Hyun;Jung, Geun
    • Korean Journal of Environmental Biology
    • /
    • v.18 no.1
    • /
    • pp.153-161
    • /
    • 2000
  • This study was carried out to examine the drift of Gammarus sobaegensis by acid stress as pH depression in Oweol creek from April 1996 to October 1996. The behavioral drifting was revealed to the characteristics of G. sobaegensis that is tend to increase as acid stress. And, tolerance level of G. sobaegensis to pH depression was different among the size classes. Individuals belong to small to medium size classes were weak in lower pH. Pattern of response in G. sobaegensis has a lower tolerance to acid stress at below pH 4.0 than above pH 5.0 in the artificial channel and show the possibility as an effective aquatic ecotoxicity test organism. The result of analysis of variance, water temperature (F-ratio : 66.596, p< 0.0005) and the size classes (F-ratio : 71.386, p< 0.0005) except pH level (F-ratio : 353.415, p<0.0005) were showed to the major factor for drift behavior by acid depression. [Gammarus, pH, Drift, Acid stress, Ecotoxicity test].

  • PDF

The Study on Model Test of Tension Leg Platform(II) - Model Test & Analysis (심해 계류인장각 플랫폼의 모형시험 연구(II) - 모형시험 및 해석)

  • Kim, Jin-Ha;Hong, Sa-Young;Choi, Yoon-Rak;Hong, Sup;Kim, Hyun-Joe
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.04a
    • /
    • pp.69-74
    • /
    • 2000
  • Linear and nonlinear motion responses of a Tension Leg Platform(TLP) was investigated by model tests. The model tests were carried out at KRISO's Ocean Engineering Basin which has a deep pit of which diameter and depth are 5 meters and 12.5 meters, respectively. Optical sensors were used for measuring drift motions, and a set of accelerometers were employed for analyzing wave frequency motions. ISSC TLP was chosen as the model for the present study. Scale ratio was 1/65 and elastic modelling of tether system were conducted. Very good agreement was obtained between experimental results and theoretical calculations not only in linear motion responses but tension responses, nonlinear wave drift force and double frequency excitations.

  • PDF

Seismic Behavior of High-rise Steel Moment-resisting Frames with Vertical Mass Irregularity (수직질량 비정형이 존재하는 고층 강 모멘트-저항골조의 지진 거동)

  • Park, Byong-Jeong;Song, In-Hawn
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-15
    • /
    • 2004
  • Dynamic analyses were carried out to study the seismic response of high-rise steel moment-resisting frames in sixteen story buildings. The frames are intentionally designed by three different design procedures; strength controlled design. strong column-weak beam controlled design. and drift controlled design. The seismic performances of the so-designed frames with vertical mass irregularities were discussed in view of drift ratio. plastic hinge rotation, hysteretic energy input and stress demand. A demand curve of hysteretic energy inputs was also presented with two earthquake levels in peak ground accelerations for a future design application.

A digital closed-loop processor with a stabilizer for an open-loop fiber-optic gyroscope (개회로 FOG용 폐회로 신호처리기의 안정화)

  • 김도익;예윤해
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.5
    • /
    • pp.377-383
    • /
    • 2002
  • An all-digital closed-loop (ADCL) signal processor for an open-loop FOG was developed to replace the analog circuitry of a Digital Phase Tracking (DPT) signal processor with new digital circuitry. When the ADCL signal processor without a stabilizer for fiber phase modulator (FPM) was attached to the FOG, temperature drift of FOG was about 0.26$\mu$rad/$^{\circ}C$, which makes the FOG unusable in medium or higher-grade applications. This drift was due to variations of phase modulation amplitude and phase delay of the FPM. The stabilizer controls its phase modulation amplitude and phase delay by regulating the ratio of harmonics of the FOG output. Thus, the stabilizer reduces the drift of the FOG to negligible.

Drift Ratio-based Fragility Functions for Diagonally Reinforced Concrete Coupling Beams (대각보강된 철근콘크리트 연결보의 변위비 기반 취약도 함수 개발)

  • Lee, Chang Seok;Han, Sang Whan;Koh, Hyeyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.131-140
    • /
    • 2019
  • Diagonally reinforced concrete coupling beams (DRCBs) have been widely adopted in reinforced concrete (RC) bearing wall systems. DRCBs are known to act as a fuse element dissipating most of seismic energies imparted to the bearing wall systems during earthquakes. Despite such importance of DRCBs, the damage estimation of such components and the corresponding consequences within the knowledge of performance based seismic design framework is not well understood. In this paper, drift-based fragility functions are developed for in-plane loaded DRCBs. Fragility functions are developed to predict the damage and to decide the repair method required for DRCBs subjected to earthquake loading. Thirty-seven experimental results are collected from seventeen published literatures for this effort. Drift-based fragility functions are developed for four damage states of DRCBs subjected to cyclic and monotonic loading associated with minor cracking, severe cracking, onset of strength loss, and significant strength loss. Damage states are defined in a consistent manner. Cumulative distribution functions are fit to the empirical data and evaluated using standard statistical methods.