• 제목/요약/키워드: drainage tank

검색결과 46건 처리시간 0.029초

배수개선공법개발에 관한 연구(I) -각종 지하배수용 암거재료의 배수성능- (Drainage Performance of Various Subsurface Drain Materials-)

  • 김철회;이근후;유시조;서원명
    • 한국농공학회지
    • /
    • 제21권3호
    • /
    • pp.104-120
    • /
    • 1979
  • I. Title of the Study Studies on the Development of Improved Subsurface Drainage Methods. -Drainage Performance of Various Subsurface Drain Materials- II. Object of the Study Studies were carried out to select the drain material having the highest performance of drainage; And to develop the water budget model which is necessary for the planning of the drainage project and the establishment of water management standards in the water-logged paddy field. III. Content and Scope of the Study 1. The experiment was carried out in the laboratory by using a sand tank model. The drainage performance of various drain materials was compared evaluated. 2. A water budget model was established. Various parameters necessary for the model were investigated by analyzing existing data and measured data from the experimental field. The adaptability of the model was evaluated by comparing the estimated values to the field data. IV. Results and Recommendations 1. A corrugated tube enveloped with gravel or mat showed the highest drainage performance among the eight materials submmitted for the experiment. 2. The drainage performance of the long cement tile(50 cm long) was higher than that of the short cement tile(25 cm long). 3. Rice bran was superior to gravel in its' drain performance. 4. No difference was shown between a grave envelope and a P.V.C. wool mat in their performance of drainage. Continues investigation is needed to clarify the envelope performance. 5. All the results described above were obtained from the laboratory tests. A field test is recommended to confirm the results obtained. 6. As a water balance model of a given soil profile, the soil moisture depletion D, could be represented as follows; $$D=\Sigma\limit_{t=1}^{n}(Et-R_{\ell}-I+W_d)..........(17)$$ 7. Among the various empirical formulae for potential evapotranspiration, Penman's formular was best fit to the data observed with the evaporation pans in Jinju area. High degree of positive correlation between Penman;s predicted data and observed data was confirmed. The regression equation was Y=1.4X-22.86, where Y represents evaporation rate from small pan, in mm/100 days, and X represents potential evapotranspiration rate estimated by Penman's formular. The coefficient of correlation was r=0.94.** 8. To estimate evapotranspiration in the field, the consumptive use coefficient, Kc, was introduced. Kc was defined by the function of the characteristics of the crop soil as follows; $Kc=Kco{\cdot}Ka+Ks..........(20)$ where, Kco, Ka ans Ks represents the crop coefficient, the soil moisture coefficient, and the correction coefficient, respectively. The value of Kco and Ka was obtained from the Fig.16 and the Fig.17, respectively. And, if $Kco{\cdot}Ka{\geq}1.0,$ then Ks=0, otherwise, Ks value was estimated by using the relation; $Ks=1-Kco{\cdot}Ka$. 9. Into type formular, $r_t=\frac{R_{24}}{24}(\frac{b}{\sqrt{t}+a})$, was the best fit one to estimate the probable rainfall intensity when daily rainfall and rainfall durations are given as input data, The coefficient a and b are shown on the Table 16. 10. Japanese type formular, $I_t=\frac{b}{\sqrt{t}+a}$, was the best fit one to estimate the probable rainfall intensity when the rainfall duration only was given. The coefficient a and b are shown on the Table 17. 11. Effective rainfall, Re, was estimated by using following relationships; Re=D, if $R-D\geq}0$, otherwise, Re=R. 12. The difference of rainfall amount from soil moisture depletion was considered as the amount of drainage required. In this case, when Wd=O, Equation 24 was used, otherwise two to three days of lag time was considered and correction was made by use of storage coefficient. 13. To evaluate the model, measured data and estimated data was compared, and relative error was computed. 5.5 percent The relative error was 5.5 percent. 14. By considering the water budget in Jinju area, it was shown that the evaporation amount was greater than the rainfall during period of October to March in next year. This was the behind reasonning that the improvement of surface drainage system is needed in Jinju area.

  • PDF

유입량 변화에 따른 도심지 내 우수저류조 관망시스템의 안정성 검토 (Hydraulic Stability Examination of Rainwater Reservoir Pipe Network System on Various Inflow Conditions)

  • 유형주;김동현;맹승진;이승오
    • 한국방재안전학회논문집
    • /
    • 제12권4호
    • /
    • pp.1-13
    • /
    • 2019
  • 최근 기후변화로 인해 강우강도 및 빈도의 증가에 따른 국지성 집중호우의 피해가 증가함에 따라 초기 우수에 대응할 수 있는 시설물 설치가 필요한 실정이다. 이를 위해, 빗물을 직접 유출하지 않고 저류 시키는 저영향 개발(Low Impact Development)기법을 적용한 시설물 설계 및 수치모형을 이용한 유출저감효과 검토에 관한 연구가 많이 진행되어 왔다. 그러나 대부분의 연구는 유출저감효과에 대한 검토만 수행된 반면, 시설물에 유입되는 유량에 의한 흐름특성 변화 검토 및 안정성 검토에 관한 연구는 미비한 실정이다. 이에 본 연구에서는 LID 기법이 많이 적용되고 있는 회전교차로를 대상으로 하여, 회전교차로 내의 우수저류조의 관망시스템의 안정성 검토를 3차원 수치모형인 FLOW-3D를 사용하여 검토하였다. 또한 우수저류조의 최적의 설계방안 도출을 위하여 우수저류조의 수를 증가하여 용량증가에 따른 유속과 동압의 변화를 검토하고 설계기준과 비교하였다. 우수저류조의 제원 및 유입유량은 선행연구에서 제시된 값을 적용하여 수치모의를 수행한 결과, 유속은 저류조 설치개소 수가 증가할수록 빨라지는 것을 확인하였고, 대부분 설계기준 범위 안에 유속이 형성되는 것을 확인하였다. 다만 추가 저류조가 3개 이상일 경우는 추가저류조관에서 유속이 3.44 m/s가 발생하여 설계유속의 허용범위를 초과하였고, 유속의 증가율도 일정해지는 것으로 나타났다. 난류강도 및 바닥전단력 비교의 경우, 저류조 설치 개소수가 증가함에 따라 바닥전단력이 한계소류력보다 크게 나타나 유입토사의 침전은 발생하지 않을 것으로 예상되나 난류강도의 크기가 작아져 플록(Floc)형성으로 인한 토사 침전이 발생할 수 있음을 고려해야한다. 최종적으로 유속을 이용한 동압 산정 결과를 우수관 설계에 일반적으로 사용되는 압력관의 허용내압과 비교하였을 경우, 동압이 허용내압보다 작게 나타났다. 이를 통하여 본 연구에서 제안한 우수저류조 제원으로 설계할 경우 추가 저류조를 2개까지 설치하는 것이 가장 적합한 것으로 나타났다. 이는 저류조를 계속하여 설치하게 되면 배수가 원활해져 관내 유속이 빨라지고, 유속증가로 인하여 관의 마모손상 등의 문제가 일어날 수 있기 때문이다. 그러나 본 연구는 저류조의 제원 및 우수의 유입량을 가정하였고, 단순히 저류조를 추가하여 저류조 설계방안을 도출한 한계점이 있어 향후에는 다양한 저류조 형태 및 우수유입 시나리오를 적용하여 검토한다면 보다 효율적인 설계방안 도출이 가능할 것으로 기대된다.

논벼재배에 있어서의 노동력 절감에 관한 연구 (A Study on Labor Saving in Paddy Rice Cultivation)

  • 장영철
    • 한국작물학회지
    • /
    • 제11권
    • /
    • pp.81-97
    • /
    • 1972
  • 논벼농사의 노동력을 덜기 위하여 이중 가장 중요한 호미질에 의한 중경제초의 노력을 살초제에 의한 것으로 전환시키고자 기초적인 면과 실제적인 면으로 시험조사를 하였다. 건국대학교에서 1m평방 안높이 21cm 및 36cm의 두 형의 concrete tank를 각 4개씩 만들고 그 안에 채수관장치를 한 뒤 양토작토로 논벼를 심어 수도물로 관수하고 투수속도와 산소침투 정도와 수량과의 관계를 보았다. 농림부 자재 검사소 내에서 투수가 심한 사질답전포장에 전면적으로 살초제 Stam F-34를 살포하여 제초하고 제 1구는 중경을 하지 않고, 제 2구는 중경 1회, 그리고 제 3구는 중경 2회하여 중경의 효과를 비교하였다. 이리 호남시험장내 건답보통논과 습답에 무중경, 중경 1회 중경 2회의 구와 살초제 Pamcon을 살포한 것들 중, 무중경, 중경 1회 제초 2회, 중경 2회 제초 1회, 중경 3회 제초 2회의 구와 그리고 관행구를 설치하여 중경제초의 비용과 살초제에 의한 비용을 비교하였던바 그 결과를 요약하면 다음과 같다. (1) 투수속도와 산소침투와 수량과의 관계는 일당(24시간당) 투수속도 4cm이상 될 때 지표 2cm하에 산소가 조금 들어가며 3cm보다 적을 때는 산소가 지표하의 매우 옅은 층에만 내려가는 것으로 나타나며 그리고 경심 15cm구에는 일당 투수속도의 0cm(무투수) 1.5cm에서 수량이 많고 2.5cm와 3.4cm에는 감수되며, 경심 30cm구에는 투수속도 1.5cm 및 30cm구에서 수량이 많고 무투수와 투수속도 4cm구에는 수량이 떨어졌다. (2) 투수가 심한 농림부 자재검사소 사질토양에서는 중경의 효과가 없었다. (3) 호남작물시험장내 건답에서는 살초제 Pamcon 처리 무중경구 수량에 대해서 유의성이 보이는 증수구는 없었다. 그리고 습답에서는 무중경구에 있어서 중경제초 및 관행구가 유의성 있게 증수되었다. (4) 논매기 호미질에 의한 10a당 노동력은 정미 37.1시간 식사와 휴식시간 포함하여 53.5시간이고, 노임은 2,346원인데 대하여 살초제 사용에의 한제 초노력은 수동식으로 0.5일 즉 약 5시간 제비용과 감수추정량을 추정할 때 1,130원이고 습답을 제외하면 750원이 되는 것으로 추정 되었다.

  • PDF

뉴스초점: 집중호우와 도시지역 홍수방어 (Heavy Rain and Flood Prevention in Urban)

  • 정선길
    • 기술사
    • /
    • 제43권6호
    • /
    • pp.31-34
    • /
    • 2010
  • Recently, due to localized heavy rain and flash floods in urban areas is becoming more frequent flood damage. To prevent flood inundation damage, to formulate the diverse directions in connection with the drainage system of buildings, roads, sewerage, pump stations, detention (retention) pond, and streams is very important. In addition, it is important for the uniform design criteria, the consistent of hydrologic and hydraulic analysis method, and a flood disaster mitigation systems connected with structural and nonstructural measures. To accomplish this, the method such as installation of storage facilities, infiltration facilities, and underground water tank, the optimal size of the design gutter and grate of the road, ensure the capacity of pumping stations, and the installation of a flood control channel into the deep underground requires comprehensive measures dimension in urban areas.

  • PDF

적산 일사 제어법으로 관수하는 순환식 수경재배에서 배액 혼합 방식에 의한 재사용 양액 내 양분 조정효과 비교 (Comparison of Nutrient Replenishing Effect under Different Mixing Methods in a Closed-loop Soilless Culture using Solar Radiation-based Irrigation)

  • 안태인;신종화;노은희;손정익
    • 생물환경조절학회지
    • /
    • 제20권4호
    • /
    • pp.247-252
    • /
    • 2011
  • 순환식 수경재배에서 배액의 EC, 부피, 관수량은 재사용 양액의 혼합비율을 결정하는 중요한 요소 중 하나이다. 적산 일사량 제어법으로 관수할 경우 일일 관수량의 예측은 곤란하며 일반적으로 고정된 혼합비율을 사용한다. 이 경우 새 양액이 고정적으로 투입되어 양분의 조정 효과가 기대되지만, 때때로 배액의 강제배출을 필요로 한다. 본 연구는 적산 일사량 제어법으로 관수하는 순환식 수경재배 조건에서 배액의 혼합비를 고정한 처리구(FR)와 정해진 혼합 용량 내에서 배액의 부피와 EC에 따라 혼합비를 변경하는 처리구(MR)의 재사용 양액 내 양분 조정효과를 비교하여 양수분 이용효율이 높은 혼합방식의 규명에 기여하고자 수행하였다. 배액의 농도 변화를 비교하기 위한 대조구로는 비순환식 수경재배 처리구(OP)를 구성하였다. FR처리구의 배액 혼합 비율은 배액의 희석 EC를 각각1.0, $2.0dS{\cdot}m^{-1}$로 설정하여 혼합처리를 적용하였다. MR 처리구의 경우는 혼합 용량을 1회 관수량을 기준으로 배액의 EC와 부피에 따라 혼합비율이 변경되도록 하였다. 배액의 누적 현상은 FR 1.0 처리구에서 관찰되었으며, FR 2.0과 MR 처리구에서는 배액 누적현상이 나타나지는 않았으나 MR 처리구의 배액 저장량이 FR 2.0 처리구에 비해서 낮게 나타났다. 배액과 재사용 양액 내 $Mg^{2+}:K^+:Ca^{2+}$$SO^{2-}_4:NO^-_3:PO^{3-}_4$의 당량 농도 간 비율 변화는 FR, MR 처리구에서 초기비율 대비 비교적 좁은 변화 범위를 나타냈다.

여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석 (The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect)

  • 이준호;양승호;방기웅
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

무동력 토사제거시스템의 현장모형실험 (Field Model Test of the Non-power Soil Cleaning System)

  • 박찬근;이영학;홍석민;이달원
    • 한국농공학회논문집
    • /
    • 제61권4호
    • /
    • pp.63-73
    • /
    • 2019
  • Coastal and fishing facilities are gradually deteriorating in function due to the continual accumulation of soil sediments, which has affected local economic activities. Currently, there are many methods to remove soil sediments, but these methods are either a temporary solution or require a repetitive removal of the soil sediments, which is a huge financial burden for the maintenance of the facilities. To solve these problems, this study proposed a non-power soil cleaning system and evaluated field applicability by carrying out field model tests. The conditions for the evaluation focused on the drainage-elapsed time and drainage-outflow velocity according to the water level change in the water tank. In the field test, silty clay and sand were separately installed, and sedimentation soil removal test was practiced. As a result, the system was verified to have a sufficient outflow velocity for the removal of soil sediments. In addition, a generalization equation that can be used in different regions of the tide was suggested in this study. These results will greatly contribute to removing soil sediments in ports and dike gate facilities on the southwest coast. Since the system is an eco-friendly technology that does not require additional energy, thus it is expected to contribute to maintenance of sustainable facility performance as well as economic effect in the future.

샌드댐 설치에 따른 물공급 개선 효과 예비 분석 (Preliminary Analysis on Improvement of Water Supply Capacity of Sand Dam)

  • 정일문;이정우
    • 대한토목학회논문집
    • /
    • 제41권1호
    • /
    • pp.29-37
    • /
    • 2021
  • 물공급 소외지역인 산간 최상류 지역을 위한 현지 적응형 물공급 체계의 도입이 필요하다. 이를 위해서는 수원의 확보와 최적이용 방안 및 연계 가능한 수원과의 결합이 관건이다. 특히 유역 최상류에 위치한 산간지역에는 계곡수와 복류수를 통해 공급되는 지하수 유출량을 활용하는 방안을 강구해야 한다. 본 연구에서는 강원도 춘천의 가뭄발생지역을 대상으로 샌드댐을 활용한 물공급 체계의 개선방안을 모색하였다. 방법은 기존 수원 하부에 모래저류조를 가상으로 설치하여 현재 취수량을 고려한 모델링을 수행하고 추가로 샌드댐에서 취수가능한 양을 산정하는 방식으로 분석을 수행하였다. 샌드댐을 기존 수원의 4배 크기로 적용한 경우 수면경사와 수리전도도의 변화에 따라 배수량이 크게 증대하는 것으로 나타났다.

XP-SWMM 모형을 이용한 도심지역 침수해석 (Flood Inundation Analysis in Urban Area Using XP-SWMM)

  • 김진수;이원호
    • 한국지반환경공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.29-36
    • /
    • 2015
  • 현재 국내 연구는 1차원 수치해석을 통한 침수방지대책의 효과분석 및 효율성을 입증하는 형태로 본 연구에서는 2차원 도시유출모형인 XP-SWMM 모형을 침수지역에 적용, 침수방지대책을 상호 비교 분석함으로써 수자원관리자의 효율적인 정책결정에 반영할 수 있도록 하는 것이 본 연구의 목적이다. 기상데이터는 지난 1967년부터 2011년까지 45년간 청주 기상대에서 수집한 것으로 통계 분석하여 사용하였다. 대상 배수구역 통수능력 분석을 50년 빈도 모의 결과 침수면적 $539,548m^2$, 최대침수심 1.0m, 침수시간 48분으로 분석되었다. 침수대책으로 A1 소배수구역의 통수능력 증대를 위해 우회수로 및 지하저류시설 건설을 비교한 결과 대상유역에 용량이 $13,500m^3$인 지하저류시설을 설치할 경우 50년 빈도의 강우까지 침수가 완전 해소될 것으로 판단된다. 향후 침수 저감대책으로 이상기후에 대비할 수 있는 지하저류조 설치가 효율성이 좋을 것으로 판단된다.

한국형발사체 발사대시스템 산화제공급설비 상세설계 (Critical Design Result of Liquid Oxygen Filling System for Korea Space Launch Vehicle-II Launch Complex)

  • 서만수;고민호;선정운;서현민;이재준;강선일
    • 한국추진공학회지
    • /
    • 제21권2호
    • /
    • pp.102-110
    • /
    • 2017
  • 발사대시스템의 산화제공급계(Liquid Oxygen Filling System)는 발사체의 추진제(Propellant) 중 연료의 연소를 위한 산화제(Oxidizer)로 사용되는 액체산소(Liquid Oxygen)를 저장하고, 발사체 요구조건에 맞게 공급하는 하는 설비이다. 본 논문에서는 한국형발사체(KSLV-II) 발사대시스템 상세설계(Critical Design, 2015년 8월에서 2016년 4월, 8개월) 동안 수행된 한국형발사체 발사대시스템 추진제 공급설비의 산화제공급계 설계 내용을 주요 설비 구성에 대하여 구조적 관점으로 소개한다.