• Title/Summary/Keyword: dq current

Search Result 89, Processing Time 0.025 seconds

Improvement on transient response of a Indirect Controlled Current PWM - VSC (간접전류제어 PWM 전압형 CONVERTER의 과도응답 개선)

  • Park, Min-Ho;Lee, Jin-Woo;Park, Young-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.245-249
    • /
    • 1989
  • From the careful analysis of the transformed dq system equations of a PWM Voltage Source Converter ( PWM - VSC ), a novel voltage control is proposed which is based on the derivative of in-phase current component of line currents and the relation between dc-link voltage and in-phase current component. A simple logical algorithm to implement the proposed scheme is also presented at transient state. The sinusoidal PWM is adopted at steady state. The simulation results show good transient characteristics.

  • PDF

Receving-end's power factor improvement and harmonic current filtering useing the private-substion STATCOM (자가변전설비용 STATCOM의 수전단 역률개선과 고조파 전류 필터링)

  • Oh, Young-Woong;Lee, Eun-Woong;Lim, Su-Saeng;Kim, Seok-Gon;Lee, Seung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.79-81
    • /
    • 1998
  • STATCOM can compensate industrial load's reactive power and filter the harmonic of nonlinear load's with the rapid dynamic response. In this paper, STATCOM is modelled to synchronous rotating coordinate by circuit dq transformation, and space vector PWM method is applied for broad voltage modulation. Also predict current controller is used for harmonic current filtering.

  • PDF

Comparative Study of Field-Oriented Control in Different Coordinate Systems for DTP-PMSM

  • Zhang, Ping;Zhang, Wei;Shen, Xiaofeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.330-335
    • /
    • 2013
  • This paper performs two kinds of Field-Oriented Control (FOC) for dual three phase permanent magnet synchronous motor (DTP-PMSM).The first is based on vector space decomposition to study the effect of current harmonics on electromechanical energy conversion. And the second presents the coupling relations between two sets of windings using two d-q transformation. And then this paper has deeply studied the differences between these two strategies, the different effect on the control of harmonic current and the reason for these differences. MATLAB-based Simulation studies of a 3KW DTP-PMSM are carried out to verify the analysis of differences between the two FOC strategies.

An Application of Proportional-Resonant Controller in MMC-HVDC System under Unbalanced Voltage Conditions

  • Quach, Ngoc-Thinh;Ko, Ji-Han;Kim, Dong-Wan;Kim, Eel-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1746-1752
    • /
    • 2014
  • This paper presents an application of proportional-resonant (PR) current controllers in modular multilevel converter-high voltage direct current (MMC-HVDC) system under unbalanced voltage conditions. The ac currents are transformed and controlled in the stationary reference frame (${\alpha}{\beta}$-frame). Thus, the complex analysis of the positive and negative sequence components in the synchronous rotating reference frame (dq-frame) is not necessary. With this control method, the ac currents are kept balanced and the dc-link voltage is constant under the unbalanced voltage fault conditions. The simulation results based on a detailed PSCAD/EMTDC model confirm the effectiveness of the proposed control method.

Reduction of Current Ripples due to Current Measurement Errors in a Doubly Fed Induction Generator

  • Park, Gwi-Geun;Hwang, Seon-Hwan;Kim, Jang-Mok;Lee, Kyo-Beum;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.313-319
    • /
    • 2010
  • This paper proposes a new compensation algorithm for the current measurement errors in a DFIG (Doubly Fed Induction Generator). Generally, current measurement path with current sensors and analog devices has non-ideal factors like offset and scaling errors. As a result, the dq-axis currents of the synchronous reference frame have one and two times ripple components of the slip frequency. In this paper, the main concept of the proposed algorithm is implemented by integrating the 3-phase rotor currents into the stationary reference frame to compensate for the measured current ripples in a DFIG. The proposed algorithm has several beneficial features: easy implementation, less computation time, and robustness with regard to variations in the electrical parameters. The effectiveness of the proposed algorithm is verified by several experiments.

The Utility Power Factor Control system of Photovoltaic Power Generation System

  • Koh Kang-Hoon;Lee Hyun-Woo;Suh Ki-Young;Taniguchi Katsunori
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.673-676
    • /
    • 2001
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel, which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System (3상 계통연계 태양광발전시스템의 운전특성)

  • Kim, Yeong-Cheol;Jeong, Myeong-Ung;Seo, Gi-Yeong;Lee, Hyeon-U;U, Jun-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

Analysis and Compensation Control of Dead-Time Effect on Space Vector PWM

  • Shi, Jie;Li, Shihua
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.431-442
    • /
    • 2015
  • Dead-time element must be set into space vector pulsed width modulation signals to avoid short circuits of the inverter. However, the dead-time element distorts the output voltage vector, which deteriorates the performance of electrical machine drive system. In this paper, dead-time effect and its compensation control strategy are analyzed. Based on the analysis, the voltage distortion caused by dead-time is regarded as two disturbances imposed on dq axes in the rotor reference frame, which degenerates the current tracking performance. To inhibit the adverse effect caused by the dead-time, a control scheme using two linear extended state observers is proposed. This method provides a strong ability to suppress dead-time effects. Simulations and experiments are conducted on a permanent magnet synchronous motor drive system to demonstrate the effectiveness of the proposed method.

멀티레벨 전압형 인버터를 사용한 무효전력보상장치

  • Min, Wan-Gi;Kim, Byeong-Cheol;Jeon, Hyeong-Seok;Kim, Hyeong-Gon;Sin, Seok-Du;Jang, Seong-Nam;Lee, Gwang-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1999.07h
    • /
    • pp.21-25
    • /
    • 1999
  • This paper proposes a novel control strategy of SVC(Static var compensator) using cascade multilevel inverter. To control the reactive power instantaneously, the dq-dynamic system model is described and analyzed. A single pulse pattern based on the SHE(Selective Harmonic Elimination) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is applied to adjust the DC capacitor voltage at the scheme level. From the simulation, it is verified that this proposed control scheme make the dynamic control response of SVC fast, the current harmonics low, and the DC capacitor voltage balanced.

  • PDF

Complex Vector Modeling and Series Decoupling Current Control Strategy of High-Power L/LCL Type Grid-Connected Converter Under Low Switching Frequency

  • Wang, Yingjie;Jiao, Lanyi;Yang, Bo;Wang, Wenchao;Liu, Haiyuan
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1879-1888
    • /
    • 2018
  • With power level of grid-connected converters rising, the switching frequency of the switching devices is commonly greatly reduced to improve its power capacity. However, this results in serious couplings of the dq current components, which leads to degradation of the static and dynamic performances of grid-connected converters and fluctuations of the reactive power in dynamic processes. In this paper, complex vector models under low switching frequency are established for an L/LCL grid-connected converter, and the relationship between the switching frequency and the coupling degree is analyzed. In addition, a series decoupling current control strategy is put forward. It is shown that the proposed control strategy can eliminate the couplings, improve the performances and have good robustness to parameter variations through static and dynamic characteristics analyses and a sensitivity analysis. Experimental and simulation results also verify the correctness of the theoretical analyses and the superiority of the proposed control strategy.