• Title/Summary/Keyword: double-rotor

Search Result 105, Processing Time 0.028 seconds

Electromagnetic Structural Design Analysis and Performance Improvement of AFPM Generator for Small Wind Turbine

  • Jung, Tae-Uk;Cho, Jun-Seok
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.374-378
    • /
    • 2011
  • Axial Field Permanent Magnet (AFPM) generators are widely applied for the small wind turbine because of the higher power density per unit weight than that of the conventional radial field generator. It is caused by the disc shaped rotor and the stator structures. The generally used AFPM generator, AFER-NS generator, is composed of the two side's external rotors and non-slotted stator without stator core. However, the output voltage and the output power are limited by the large reluctance by the long air-gap flux paths. In this paper, the design study of AFIR-S generator having double side's slotted stator core is accomplished to improve the output generation characteristics. The electromagnetic design analysis and the design improvement of the suggested AFIR-S generator are studied. Firstly, the electromagnetic design analysis was done to increase the power density. Secondly, the design optimizations of the rotor pole-arc ratio of permanent magnet are accomplished to increase the output power and to reduce the cogging torque. Finally, the output performances of AFER-NS and AFIR-S generator are compared with each other. For this study, 3D FEA is applied for the design analysis because of three dimensional electromagnetic structures.

소형 풍력발전기용 AFPM 발전기 코깅토크 저감 설계 (Cogging Torque Reduction in AFPM Generator Design for Small Wind Turbines)

  • 정대원
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1820-1827
    • /
    • 2012
  • This paper is to present a new method of cogging torque reduction for axial flux PM machines of multiple rotor surface mounted magnets. In order to start softly and to run a power generator even the case of weak wind power, reduction of cogging torque is one of the most important issues for a small wind turbine, Cogging torque is an inherent characteristic of PM machines and is caused by the geometry shape of the machine. Several methods have been already applied for reducing the cogging torque of conventional radial flux PM machines. Even though some of these techniques can be also applied to axial flux machines, manufacturing cost is especially higher due to the unique construction of the axial flux machine stator. Consequently, a simpler and low cost method is proposed to apply on axial flux PM machines. This new method is actually applied to a generator of 1.0kW, 16-poles axial flux surface magnet disc type machine with double-rotor-single-stator for small wind turbine. Design optimization of the adjacent magnet pole-arc which results in minimum cogging torque as well as assessment of the effect on the maximum available torque using 3D Finite Element Analysis (FEA) is investigated in this design. Although the design improvement is intended for small wind turbines, it is also applicable to larger wind turbines.

송전선로 고장제거 지연에 따른 동기 탈조 계전기 동작 검토 (A Study on Out-of-Step Relay Operation due to Delayed Fault Clearing in Transmission Line)

  • 박지경;김광현;김철환;유영식;양정재
    • 전기학회논문지
    • /
    • 제66권10호
    • /
    • pp.1466-1473
    • /
    • 2017
  • Generally, electrical torque in synchronous generator is balanced with the rotor mechanical torque under steady-state condition. Thus, the synchronous generator rotor rotates at constant speed. However, under fault condition, the electrical torque output is suddenly decreased and the sum of both torques does not remain constant. If the mechanical torque is not decreased at the same time, the generator rotor would accelerate. Therefore, this accelerating generator rotates at different speeds with respect to other generators in the power system. This phenomena is called as Out-of-Step (OOS). In this paper, we presented a certain two-step type quadrilateral OOS relay setting, which is applicable in actual field, and examined the validity of its setting value with OOS simulation conditions due to delayed fault clearing in transmission line. In order to conduct the study of OOS relay characteristics, we checked the impedance locus and generator output characteristics under the various delayed fault clearing conditions. Moreover, we proposed a countermeasure for avoiding the misoperation of OOS relay during the stable swing by modifying the setting values.

CrMoV강 용접부의 주기적 열시효처리에 따른 미세조직, 미세경도 및 인장강도 특성 (A Characteristic of microstructural evolution, microhardness and tensile properties in CrMoV rotor steel weldment experienced by the cyclic thermal aging heat treatment)

  • 김광수;고진현
    • 열처리공학회지
    • /
    • 제12권4호
    • /
    • pp.303-312
    • /
    • 1999
  • An investigation of the CrMoV rotor steel weldment which experienced by cyclic thermal aging heat treatment and as-received condition was performed. This evaluation was carried out to confirm whether this type of weldment is appropriate for the service environment in terms of microstructural examinations, microhardness measurements and tensile tests. The cyclic thermal aging heat treatment, containing continuous heating and cooling thermal cycle was programmed to simulate the real rotor service condition. The heat treatment was performed for 40 cycles(5920hrs). The results indicated that the weldment was composed of 4 different regions such as heat affected zone of the base metal, butter weld(initial weld), full thickness weld(final weld) and the base metal. The double welding process was applied to eliminate the susceptibility of reheat cracking at heat affected zone of base metal. The grain refinement at the HAZ due to the welding process could reduce the possibility of cracking susceptibility, but its tensile properties was appeared to be low due to the weld metal in as-received condition. The benefit effect, grain refinement was extended with carbides coarsening during the cyclic thermal aging heat treatment. However the poor mechanical properties of the weldment was more degraded as undergoing the heat treatment.

  • PDF

2인승 틸트로터형 PAV 개념설계 및 공력해석 (Conceptual Design and Aerodynamic Analysis of Double-Seater Tilt-rotor Type PAV)

  • 조윤성;김성지;백수빈;김영채;배근학;조은별;유지수;홍영훈
    • 한국항행학회논문지
    • /
    • 제26권3호
    • /
    • pp.144-160
    • /
    • 2022
  • 차세대 이동 수단의 방법으로 도심항공 모빌리티(UAM)에 관한 연구가 활발하게 진행되고 있다. 도심항공 모빌리티에 사용할 비행체인 eVTOL(Electric Vertcial Take-Off and Landing)은 추진방식에 따라 복합형, 틸트 로터형, 틸트 날개형, 틸트 덕티드 팬형, 멀티콥터형으로분류된다. 본 연구에서는 새로운 틸트 로터형의 차세대 eVTOL을 기존의 설계 요구 조건에 맞게 개념설계를 수행하였다. 공력해석 프로그램인 Open VSP와 XFLR5를 사용하여 공력해석을 진행하였다. 각 임무 구간별 소요되는 동력을 계산하였고, 그에 맞는 배터리와 모터를 선정하였으며, 구성품별 중량을 추정하여 최대이륙중량을 예측하였다.

비정상 압력측정을 통한 축류휀 유동특성에 관한 연구 (A Study on the Flow Characteristics of an Axial Flow Fan by Unsteady Pressure Measurement)

  • 강창식;신유환;김광호;이두열
    • 한국유체기계학회 논문집
    • /
    • 제5권3호
    • /
    • pp.15-24
    • /
    • 2002
  • This paper presents an experimental study on the unsteady flow phenomena such as leakage flow and rotating stall which have influences on the performance and stability of an axial flow fan. For this study, unsteady pressure were measured using high frequency pressure transducers mounted on the easing wall of rotor passage and analyzed by Double Phase-Locked Averaging Technique. As the flow rate was reduced to near stall point, the pressure difference between the pressure and the suction side of the blade was increased especially new the leading edge and the lowest pressure zone of suction side was gradually developed. From the result of unsteady pressure field on the casing wall, one period of rotating stall was divided into three zones and the flow characteristics on each zone were described in detail.

A Novel Double-Loop Vector Control Strategy for PMSMs Based on Kinetic Energy Feedback

  • Wang, Anbang;Wang, Qunjing;Jiang, Weidong
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1256-1263
    • /
    • 2015
  • A novel vector control strategy for a permanent magnet synchronous motor (PMSM) based on the kinetic energy stored in the rotor is proposed in this paper. The novel strategy is composed of two closed loops, in which the current loop is the inner loop, and the kinetic energy serves as the outer loop. The theoretical basis and the design procedure of the two loops are given. The feasibility of the proposed control strategy is verified by experimental results. When compared with traditional vector control strategies, the proposed vector control strategy based on energy feedback has better dynamic performance. In addition, an effective estimation solution for the load variation is put forward.

이중 회전자 구조를 갖는 3상 BLDC 전동기 최적운전 알고리즘 연구 (Optimal Drive Algorithm Research for Three-Phase BLDC Motor with Double Rotor)

  • 정현우;김장식;김장목
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.10-11
    • /
    • 2011
  • 단일 회전자 전동기와 달리 동일한 크기에서 높은 출력 밀도와 높은 토크의 장점이 있는 이중 회전자 구조를 갖는 전동기는 공간적 제약을 받는 전기 자동차, 전기 이륜차 등의 분야에 활발히 연구되고 있다. 이중 회전자 구조를 갖는 전동기는 고 토크 운전을 위해 이중 인버터 운전 방식이 요구된다. 이때, 내부와 외부전동기의 역기전력이 다를 때 이를 고려하지 않고 운전한다면 발생하는 동손이 증가하여 운전효율 저하로 이어진다. 본 논문에서는 이중 회전자 구조를 갖는 3상 BLDC 전동기에서 내부와 외부전동기의 역기전력비(${\alpha}$)와 고정자 저항 비(${\beta}$)를 고려한 전류분배방식을 통해 동손을 최소화하는 최적운전 알고리즘을 제안하였다.

  • PDF

단상 Twin sSator유도기의 특성해석에 관한 연구 (An Analysis on the Performance of a Twin Stator Single-Phase Induction Manchine)

  • 황영문
    • 전기의세계
    • /
    • 제21권3호
    • /
    • pp.7-18
    • /
    • 1972
  • An analysis is made for the performance of twin stator single-phase induction machine having any movable asymmetrical angle of stator windings, with any symmetrical or asymmetrical magnetizing reactance and winding turn-ratio between two stators, provided that asymmetrical common squirrel cage rotor is utilized. This mechanism is a new type, which has the advantage of mading only not the performance prediction in applications as a single-phase electromagnetic driving mechanism but also the analysis prediction of single-phase induction motor with not in quadrature axis. The basis of the analyses are lead by Kron's primitive machine matrix and Morrill's double-revolving field concept. All the performances can be calculated from the test values and design details of the asymmetrical magnetizing reactance twin stator single-phase induction machine and verified by test. And its validity is still demonstrated to the pure twin stator single-phase induction machine.

  • PDF

다자유도 구형 구동 모터의 와전류 손실 저감을 통한 효율 향상 연구 (Improve of efficiency of Multi D.O.F spherical motor through the reduction of eddy current loss)

  • 홍경표;이원국;이호준;강동우;원성홍;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.947-948
    • /
    • 2011
  • Efficiency of Multi D.O.F spherical motor is one of the important performance indicators. So Through the reduction of eddy current loss on how to improve the efficiency were studied. Stator iron core's material with high permeability and resistivity of material using the eddy current loss was reduced. However, it was the disadvantages of production and economic. For these reasons, prevent eddy current loss of the iron core of multi D.O.F spherical motor as a viable alternative to motor using rotor with double-air gap.

  • PDF