A Study on the Condensation and Thermal Environment according to Window Systems Types Installed for a Extended-Balcony Apartment (확장형 발코니 공동주택의 창호종류에 따른 결로 및 온열환경에 관한 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Kim, Byoung-Soo
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.87-92
    • /
    • 2007
  • As expansion of balconies at apartments has been legalized, the major function of the balconies as a thermal buffer zone is disappearing. This weakens the ability of window to insulate heat and multiplies surface condensation. Thus more and more residents require solutions to increasing surface condensation and aggravation in thermal comfort. This study intends to provide basic data by evaluating performance of triple layered Low-E windows, triple layered clear windows, double layered Low-E windows and double layered clear window used for expanded balconies and marketed within the country in terms of surface condensation and thermal environment through simulation. Results revealed that no surface condensation occurred at double layered Low-E windows and triple layered Low-E windows. Surface condensation took place at double layered clear windows and triple layered clear windows at a relative humidity of 60%. Thermal environment analysis suggested that double layered clear windows showed the most time falling into the range of comfort at $23^{\circ}C$. The figure were $22^{\circ}C$ for triple layered clear windows, $22^{\circ}C$ for double layered Low-E windows and $21^{\circ}C$ for triple layered Low-E windows.

A Study on the Windows and Doors of Traditional Houses in Jecheon (제천시 전통주거의 창호 특성에 관한 연구)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.4
    • /
    • pp.94-103
    • /
    • 2013
  • This study investigated the windows and doors of traditional houses in Jecheon, designated as a cultural assets in Chungcheongbuk-do. It aimed to contribute to the study of korean traditional architecture by finding the characteristics of windows and doors, and to the preservation and reuse policy of local cultural assets. This study was conducted using the research methods of the literature and field survey, and it was to analyze and to compare the existing data and a current status. The result are as followings. Firstly, the windows and doors of kitchen in An-chae were generally installed double swinging type with wooden board door(板張門). Secondly, the windows and doors of An-bang were generally installed double swinging type with slender-ribbed windows and doors(細箭窓戶), were mostly installed Merum(遠音). Thirdly, the windows and doors of Daechung(大廳) towards the backyard were generally installed double swinging type with wooden board door, corrugated cardboard door(骨板門) and slender-ribbed windows. Lastly, the windows and doors of Sarang-bang in a house of nobility(班家) was installed triple windows and doors.

A Study on the Sound Proof Efficiency of Windows for Road Traffic Noise (도로변 건물의 창문과 방음효과에 대한 평가)

  • 박성배;신재영;정종흡;정일현
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.56-62
    • /
    • 1995
  • Recently, the traffic noise around residences and schools has become a serious social problem with the increase of the amount of transportation. This study was performed to investigate the sound proof efficiency of windows for traffic noise. The results were as follows 1) The traffic noise in 19 sites among 22 sampling sites was higher value than 65 dB(A) being roadside environment standard level in the daytime when all windows were opened, while the noise in 22 sampling sites was transmitted below standard level when all windows were closed. 2) The transmission loss of sound level at single window and double windows were 10~25 dB(A) and 11~29 dB(A) respectively. 3) The transmission loss of sound level at sampled school with sound proof pannel was 7~8 dB (A), which was lower 2~7 dB(A) than the theoretical value of the influence assessment . 4) The construction cost of double windows was lower 28% even if include the cost of setting up air conditioner for the summer season and the power consuming cost for its operation than that of sound proof pannel for traffic noise. 5) The effect of transmission loss of windows was more influenced by airtight than materials of windows.

  • PDF

A Study on the Windows and Doors of Jecheon Park Dosu's House and Jeong Wontae's House (제천 박도수가옥 및 정원태가옥의 창호에 관한 연구)

  • Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.5
    • /
    • pp.96-103
    • /
    • 2014
  • This study investigated the windows and doors of Jecheon Park Dosu's House and Jecheon Jeong Wontae's House, designated as a Important Folklore Cultural Heritage in Jecheon. It aimed to contribute to the study of traditional house, and to the conservation policy of architectural Heritage in Jecheon. This study used the research methods of the literature analysis and the field survey, and it was to analyze the spatial characteristics of the windows and doors in each building. The result are as followings. Firstly, the wooden board door(板張門) of a hinged door type is found in the kitchen of An-chae, and the Bongchang(封窓) and Gwangchang(光窓) towards the courtyard is installed for ventilation and lighting. Secondly, the slender-ribbed windows and doors(細箭 窓戶) of double swinging type towards the courtyard is installed in An-bang, and Merum(遠音) is found. Thirdly, the framed panel door(骨板門) of a hinged door type towards the backyard is found in Daechung(大廳). Lastly, the slender-ribbed windows and doors of double swinging type towards the outside is found in Sarang-bang of Sarang-chae, and Merum(遠音) is installed. Especially, double skin windows and doors is installed in Jecheon Park Dosu's House.

Fractal-Space Multiplexing using Double-Focusing Lens (이중초점렌즈를 이용한 Fractal-Space 다중화)

  • 김수길;황보승
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.243-246
    • /
    • 2002
  • We proposed a new spatio-angularly multiplexed holographic memory system using moving windows and double-focusing lens, which can eleminate crosstalk due to two neighboring moving windows(MW) in the vertical direction of the conventional MW holographic memory system and demonstated its feasibility through optical experiments.

  • PDF

An Experimental Study on Indoor Thermal Characteristics in accordance with the Use of Windows and Blinds in Double Skin Facade in Summer (이중외피에서 창문 개폐 및 블라인드 설치에 따른 하절기 실내 열환경 특성 변화 실험 연구)

  • Kim, Dong-Kyun;Yoon, Kap-Chun;Kang, Jae-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.59-67
    • /
    • 2011
  • This paper is focused on the effect of indoor temperature rise according to the use of windows and blinds in double skin facade in summer. For the experiment, we set up the mock-up of double skin facede and measuring temperature and solar radiation. Total 7 cases were used for measuring solar transmittance and indoor temperature rise. When the venetian blind was not installed, solar transmittance was 44.5%, and solar transmittance for the case that installed the venetian blind (angle 0) was 22.5%. Cases that opened inner and outdoor windows for ventilation showed lower indoor temperature rise than cases with closed windows. In addition, Case 5 (opened inner and outdoor windows with the venetian blind (angle 0) to reduce solar transmittance) indicated lower indoor temperature rise than Case 3(opened inner and outdoor windows). Consequently, Case 5 which uses inner and outdoor window for ventilation and venetian blind to reduce solar transmittance is the most effective way to reduce indoor temperature rise among all cases tested in this research.

Comparison on the Economical Efficiency of the Multiple Glazed Windows According to Life Cycle Costing of an Officetel Model Building (오피스텔 모델건물의 생애주기비용 분석에 의한 다층유리창 경제성 비교)

  • Jung Gun-Joo
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.101-109
    • /
    • 2006
  • The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.

Indoor Airflow of High-Rise Apartment with Different Types of Box-Windows (초고층 공동주택의 이중외피 창호 유형별 실내기류 특성 비교)

  • Choi, Tae-Hwoan;Jeon, Mi-Sook;Lee, Jung-Hyun;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.993-998
    • /
    • 2006
  • High-rise apartments have a problem using natural ventilation because of the strong outdoor wind velocity. Conventional high-rise apartments have adopted mechanical ventilation systems to maintain the indoor air quality. However, it leads to the overuse of electricity and the sick house syndrome. Double-skin facade is the alternative for the high-rise building to use natural ventilation and this study is focused on the performance of the box-window, which is a kind of double-skin facades. Indoor wind velocity and HCHO concentrations are analyzed with three types of box-windows: the diagonal type, parallel type and perpendicular type. The airflow is simulated by computational fluid dynamics program. Box-windows reduce the maximum value of indoor wind velocity about 50% compared with the single window and the HCHO concentrations do not have the big difference. Box-windows could be the alternative to enhance the use of the natural ventilation and indoor air quality of the high-rise apartment.

  • PDF

Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis (난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가)

  • Jang, Cheol-Yong;Kim, Jeong-Gook;Ahn, Byung-Lip;Kim, Jun-Sup;Haan, Chan-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.