• 제목/요약/키워드: double inlet

검색결과 113건 처리시간 0.026초

Concentric Double Pipe 열교환기에서 냉각수 급랭 현상의 모사에 대한 연구 (Study on Simulation of Cooling Water through Concentric Double Pipe Heat Exchanger )

  • 최안철;이성우;신익호;최성웅
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.741-747
    • /
    • 2023
  • In this study, the heat transfer characteristics were numerically analyzed to investigate the possibility of utilizing cooling water using liquid nitrogen. From the study, as the mass flow rate of the hot fluid increased, the heat transfer rate increased by 8.9-81.7%. And lowering the inlet temperature of the hot fluid resulted in increase in the heat transfer rate by 33.8-71.5%. As for the filling level of liquid nitrogen, as higher filling level led to a decrease in the outlet temperature and an increase in the overall heat transfer coefficient.

십자형심장에 동반된 양대혈관우심실기시증 -수술치험 1례 (Double Outlet of Right Ventricle in Criss-Cross Heart -Surgical Experience of One Case)

  • 김대연;조성래;박성달;정현기
    • Journal of Chest Surgery
    • /
    • 제30권12호
    • /
    • pp.1242-1246
    • /
    • 1997
  • Criss-cross heart which is a cardiac malformation caused by abnormal rotation of the ventricles early in embryonic development, is rare but a double outlet of right ventricle in priss-cross heart is very rare. We experienced a case of criss-cross heart which is situs solidus, concordant atrioventricular connection and double outlet of rig t ventricle with remote ventricular septal defect of perimembranous inlet type. A 4-years old female was diagnosed as a double outlet of right ventricle in criss-cross heart after echocardiography, cardiac catheterization and cardiac angiography. The surgical correction was a intraventricular reconstruction of left ventricular outflow with 314 circle of 20 mm Hemashield vascular graft from the ventricular septal defect to the aorta. The patient had a temporary atrioventricular block but was recovered uneventfully, and a postoperative echocardiogram showed no left ventricular outflow obstruction, no intracardiac shunt.

  • PDF

이중관형 연속 반응기에서 수증기-메탄 개질반응의 실험 및 CFD 시뮬레이션 (A Comparison with CFD Simulation and Experiment for Steam-methane Reforming Reaction in Double pipe Continuous Reactor)

  • 신동우;김래현
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.226-236
    • /
    • 2013
  • 고온개질기를 이용한 수증기 메탄 개질반응에 대해 실험 및 전산해석 기법을 이용하여 실제 개질기의 효율 및 개질기의 형상의 변화에 따른 열 분포 및 내부 유동에 대해서 연구하였다. 수증기 개질에 대한 반응모델은 Xu & Froment에 의해 개발된 수증기 반응 모델을 사용하였고, 그 결과로 고온개질기내에서 일어나는 화학반응은 Steam Reforming(SR), Water Gas Shift(WGS), Direct Steam Reforming(DSR) 반응이 다른 반응을 지배한다고 가정하였다. 고온개질기를 이용한 수증기 메탄 개질 반응 실험 결과로는 Steam Carbon Ratio(SCR)이 증가함에 따라 수소 수득율 또한 증가하고 일산화탄소와 메탄은 감소하는것을 알 수 있었다. 또한 입구가 한 개인 디자인과 두 개인 디자인을 비교, 분석하였을 때 입구가 두 개인 개질기보다 입구가 한 개인 개질기에서 열 분포 및 내부유동, 수소 수득율이 우수하다는 결과를 얻게 되었다.

An optimum design study of interlacing nozzle by using Computational Fluid Dynamics

  • Juraeva Makhsuda;Ryu Kyung-Jin;Kim Sang-Dug;Song Dong-Joo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.395-397
    • /
    • 2006
  • Air interlacing serves to protect the yarn against damage, strengthens inter-filament compactness or cohesion, and ensures fabric consistency. The air interlacing nozzle is used to introduce intermittent nips to a filament yarn so as to improve its performance in textile processing. The effect of various interlacing nozzle geometries on the interlacing process was studied. The geometries of interlacing nozzles with single or multiple air inlets located across the width of yarn channels are investigated. The basis case is the yarn channel, with a perpendicular main air inlet in the middle. Other cases have main air inlets, slightly inclined double sub air inlets, The yarn channel cross sectional shapes are either semicircular or rectangular shapes. The compressed impinging jet from the main air inlet hole hits the opposing bottom wall of the yarn channel, is divided into two branches, joins with the compressed air coming out from sub air inlet at the bottom and creates two free jets at both ends of the yarn channel. The compressed air movement in the cross-section consists of two opposing directional vortices. The CFD-FASTRAN flow parallel solver was used to perform steady simulations of impinging jet flow inside of the interlace nozzles. The vortical structure and the flow pattern such as pressure contour, particle traces, velocity vector plots inside of interlace nozzle geometry are discussed in this pater.

  • PDF

PIV기법을 이용한 원헝단면을 갖는 90$^{\circ}$ 곡관내의 선회유동의 난류특성에 관한 실험적 연구 (Experimental Study on Turbulent Characteristics of Swirling Flow in 90$^{\circ}$ Degree Circular Tube by Using a PIV Technique)

  • 장태현;이해수
    • 한국가시화정보학회지
    • /
    • 제1권2호
    • /
    • pp.38-46
    • /
    • 2003
  • An experimental investigation was performed to study the turbulent characteristics of swirling flow a 90$^{\circ}C$ circular tube for Re = 10,000, 15,000 and 20,000. 2D-PIV(Particle Image Velocimetry)technique was employed to measure the fluctuation velocity field. The results include spatial distributions of mean velocity vectors, turbulence intensity and turbulence kinetic energy. The axial and radial turbulence intensities, and kinetic energy profiles show double-peak structures in the inlet region of the 90 degree bend and the profiles are disappeared along the test tube with decaying the swirl intensity.

  • PDF

Thiobacillus ferrooxidans 생물막과 화학적 방법에 의한 항화수소 처리 공정 개발

  • 정승호;장영선;차진명;김태원;이광연;오민하;박돈희
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2002년도 생물공학의 동향 (X)
    • /
    • pp.423-426
    • /
    • 2002
  • A novel process for $H_2S$ gas treatment has been introduced, based on the combined action of a chemical absorption step and a biological step involving the biocatalytic activity of the bacterium Thiobacillus ferrooxidans. The aim of this study is the development of a process for $H_2S$ elimination from gas streams based on that chemical/biological method. The immobilized biomass reactor/chemical adsorption system is suitable for application of the removal of $H_2S$. A double stage reactor was used for the experimental work. The removal efficiencies of over 99% were observed in the range of inlet $H_2S$ concentration from 200 to 1,000ppm. The novel process showed the stable elimination efficiencies of over 95% under the retention time range from 20 to 40sec at the 1,000ppm of $H_2S$ inlet concentration.

  • PDF

이중원추형 모형연소기에서 압력과 공기비에 따른 NOx 배출특성 (Effect of Pressure and Stoichiometric Air Ratio on NOx Emissions in Gas-Turbine Dump Combustor with Double Cone Burner)

  • 남동현;남현수;한동식;김규보;조승완;김한석;전충환
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.251-257
    • /
    • 2012
  • 본 연구에서는 이중원추형 버너가 장착된 고압연소기를 이용하여 입구공기온도, 공기비 그리고 연소실 압력조건에 따른 NOx 배출 특성을 실험적으로 조사하였다. 배기가스 온도와 NOx 배출량은 동일한 연소실 끝단지점에서 측정되었다. NOx 배출량은 공기비가 증가함에 따라 감소하는 경향을 나타내었으며, 입구공기 온도와 연소실의 압력이 높아질수록 증가하는 경향을 나타내었다. 특히 입구공기 온도의 증가는 희박 영역에서 가연한계를 증가시켜 높은 단열화염 온도를 가짐에도 불고하고 저감된 NOx 배출 수준을 얻을 수 있었다. 연소실 압력이 증가할수록 Thermal NOx의 영향을 받는 영역에서의 NOx 배출은 큰 폭의 상승을 보였으나, 공기비가 1.8이상인 영역에서는 적은 연료량으로 인하여 적은 상승폭을 나타내었다.

원시험 데이터 일반화를 적용한 원심압축기 설계 (Application of Generalized Experimental Data Correlation in Centrifugal Compressor Design)

  • 조규식;김진한;양수석;이대성
    • 한국유체기계학회 논문집
    • /
    • 제3권4호
    • /
    • pp.38-43
    • /
    • 2000
  • Recently, KARI(Korea Aerospace Research Institute, Korea) and CIAM(Central Institute of Aviation Motors, Russia) have made an effort in developing a centrifugal compressor for a small gas turbine engine as part of a collaboration program. This compressor has been designed as a sub-component for an axial-centrifugal compression system for a small turbo-shaft engine aiming adiabatic efficiency higher than 0.81. The geometrical design requirement imposes restrictions to have high inlet hub-to-tip ratio and inlet swirl flow. In this study, the compressor has been designed using the generalized experimental data established from those compressors having pressure ratio of 3.7 to 5. From this generalized empirical correlation, desirable values of design parameters could be obtained. Subsequently, quasi-3D and 3D viscous flow analyses have been performed to ensure the adopted methodology. It is expected that the centrifugal compressor provides total pressure ratio of 4.89, corrected mass flow-rate of 1.64kg/sec, and adiabatic efficiency of 0.815 with inlet hub-to-tip ratio of 0.641. These relatively high total pressure ratio and inlet hub-to-tip ratio are the main distinctive features in this design. Besides, one of the main features of this centrifugal compressor is the adoption of a double-row bladed diffuser to effectively decelerate the transonic flow leaving the impeller. The compressor has been manufactured and will be tested in the near future.

  • PDF

주기적 선회실속이 발성하는 축류홴의 3차원 유동구조 (Three Dimensional Flow Structure under Rotating Stall in an Axial Flow Fan)

  • 강창식;신유환;김광호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.105-110
    • /
    • 2002
  • Experimental study was conducted to reveal the instability such as leakage flow and rotating stall in an axial flow fan. For this study, unsteady total pressure probe and multi-hole pressure probe were specially designed for measuring the flow field upstream and downstream of rotor. The measured pressure signal was analyzed by Single and Double Phase Locked Averaging Technique. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the structure of the stall cell in radial direction was provided. Also, detailed flow measurements were carried out with a specially designed high frequency multi-hole pressure probe, providing some insight to the leakage flow and their interation.

  • PDF

수직이중관형 잠열축열장치의 성능분석 (Performance Analysis of a Vertical Double Pipe Heat Exchanger for Latent Heat Storage)

  • 김영복;송현갑
    • 태양에너지
    • /
    • 제10권1호
    • /
    • pp.38-46
    • /
    • 1990
  • 고밀도 잠열축열장치의 최적설계와 효율적인 작동을 위해서는 그 전열특성과 축열효율이 규명되어야 한다. 본 연에서는 수직이중관형 잠열축열장치의 방열과정에서의 전열특성을 이론 및 실험적으로 분석하였으며 두 결과는 잘 일치하였다. 그리고 컴퓨터 시뮬레이션을 통하여 방열효율에 대한 설계 및 작동피라미터의 영향을 분석하였다.

  • PDF