Double Boost Power-Decoupling Topology Suitable for Low-Voltage Photovoltaic Residential Applications Using Sliding-Mode Impedance-Shaping Controller

  • Tawfik, Mohamed Atef;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.881-893
    • /
    • 2019
  • This paper proposes a practical sliding-mode controller design for shaping the impedances of cascaded boost-converter power decoupling circuits for reducing the second order harmonic ripple in photovoltaic (PV) current. The cascaded double-boost converter, when used as power decoupling circuit, has some advantages in terms of a high step-up voltage-ratio, a small number of switches and a better efficiency when compared to conventional topologies. From these features, it can be seen that this topology is suitable for residential (PV) rooftop systems. However, a robust controller design capable of rejecting double frequency inverter ripple from passing to the (PV) source is a challenge. The design constraints are related to the principle of the impedance-shaping technique to maximize the output impedance of the input-side boost converter, to block the double frequency PV current ripple component, and to prevent it from passing to the source without degrading the system dynamic responses. The design has a small recovery time in the presence of transients with a low overshoot or undershoot. Moreover, the proposed controller ensures that the ripple component swings freely within a voltage-gap between the (PV) and the DC-link voltages by the small capacitance of the auxiliary DC-link for electrolytic-capacitor elimination. The second boost controls the main DC-link voltage tightly within a satisfactory ripple range. The inverter controller performs maximum power point tracking (MPPT) for the input voltage source using ripple correlation control (RCC). The robustness of the proposed control was verified by varying system parameters under different load conditions. Finally, the proposed controller was verified by simulation and experimental results.

Electrical Quadruple Layer under the AC Electric Field

  • Suh, Yong-Kweon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.167-176
    • /
    • 2006
  • In this paper we show that solutions of the nonlinear Nernst-Planck equation possesses the quadruple-layer structure near the interface when the electrolyte receives a high frequency forcing such as a high-frequency alternating current. Very near to the interface wall, the well-known, classical Stern layer exists. Near to the Stern layer we have the secondly thin layer (to be called inner layer in this paper) where the ion concentrations behave under the same frequency as the external forcing. However, in this layer, the positive and negative ion concentrations develop with the time phase 180-degree different from each other. Next to this second layer, we have the third layer (called middle layer) in which two ion concentrations change with the time period double the forcing, and both concentrations behave in the same time phase. In the outermost layer, i.e. the forth layer, (called outer layer) the ion concentrations show the same-phase development as the third one but decaying very slowly in time. Our assertion is mostly based on the 1-D numerical simulation for the Nernst-Planck equation under a high frequency AC field assuming that the quadruple layer is very thin compared with the length scale representative of the bulk region.

  • PDF

A 1.2-V Wide-Band SC Filter for Wireless Communication Transceivers

  • Yang, Hui-Kwan;Cha, Sang-Hyun;Lee, Seung-Yun;Lee, Sang-Heon;Lim, Jin-Up;Choi, Joong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권4호
    • /
    • pp.286-292
    • /
    • 2006
  • This paper presents the design of a low-voltage wide-band switched-capacitor (SC) filter for wireless communication receiver applications. The filter is the 5th-order Elliptic lowpass filter. With the clock frequency of 50MHz implying that an effective sampling frequency is 100MHz with double sampling scheme, the cut-off frequency of the filter is programmable to be 1.25MHz, 2.5MHz, 5MHz and 10MHz. For low-power systems powered by a single-cell battery, the SC filter was elaborately designed to operate at 1.2V power supply. Simulation result shows that the 3rd-order input intercept point (IIP3) can be up to 27dBm. The filter was fabricated in a $0.25-{\mu}m$ 1P5M standard CMOS technology and measured frequency responses show good agreement with the simulation ones. The current consumption is 34mA at a 1.2V power supply.

FACTS 기기의 고조파 저감을 위한 이중밴드 히스테리시스 전류 제어에 관한 연구 (A Study on Double Band Hysteresis Current Control based on 3-Level Inverter to reduce the harmonic component in output current of FACTS devices)

  • 최원경;최정혜;김범식;신은철;이상빈;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.180-182
    • /
    • 2005
  • The current control using a conventional hysteresis controller of a STATCOM based on two level VSI (Voltage Source Inverter) has high switching frequency and variable modulation frequency. This will increase the switching loss. In addition, the current error is not strictly limited So, in this paper to reduce the switching frequency and to maintain the constant modulation frequency, a novel double band hysteresis current controller based on 3-level VSI is proposed. A conventional hysteresis current control and a novel hysteresis current control was tested with digital simulation and verified the advantage of the novel hysteresis current controller.

  • PDF

A Double-Hybrid Spread-Spectrum Technique for EMI Mitigation in DC-DC Switching Regulators

  • Dousoky, Gamal M.;Shoyama, Masahito;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.342-350
    • /
    • 2010
  • Randomizing the switching frequency (RSF) to reduce the electromagnetic interference (EMI) of switching power converters is a well-known technique that has been previously discussed. The randomized pulse position (RPP) technique, in which the switching frequency is kept fixed while the pulse position (the delay from the starting of the switching cycle to the turn-on instant within the cycle) is randomized, has been previously addressed in the literature for the same purpose. This paper presents a double-hybrid technique (DHB) for EMI reduction in dc-dc switching regulators. The proposed technique employed both the RSF and the RPP techniques. To effectively spread the conducted-noise frequency spectrum and at the same time attain a satisfactory output voltage quality, two parameters (switching frequency and pulse position) were randomized, and a third parameter (the duty ratio) was controlled by a digital compensator. Implementation was achieved using field programmable gate array (FPGA) technology, which is increasingly being adopted in industrial electronic applications. To evaluate the contribution of the proposed DHB technique, investigations were carried out for each basic PWM, RPP, RSF, and DHB technique. Then a comparison was made of the performances achieved. The experimentally investigated features include the effect of each technique on the common-mode, differential-mode, and total conducted-noise characteristics, and their influence on the converter’s output ripple voltage.

이강우심실을 동반한 양대혈관 우심실 기시증의 수술 치험 (Surgical Experience of Double Outlet Right Ventricle with Double Chambered Right Ventricle)

  • 김원곤;김응중;김종환
    • Journal of Chest Surgery
    • /
    • 제18권2호
    • /
    • pp.288-292
    • /
    • 1985
  • The division of the right ventricle into two chambers by aberrant muscle bands traversing the sinus portion, Double Chambered Right Ventricle[DCRV], is a relatively rare congenital cardiac malformation. Double Outlet Right Ventricle[DORV], basically recognized by the origin of both great arteries from the morphologic right ventricle, is also a rare anomaly; its frequency has been reported as approximately 0.09 case per 1,000 birth. DORV associated with DCRV, unusual combination, is even more rare; only a few known cases have been recorded previously in the literature. This report presents our surgical experience with this rare anomaly, DORV with DCRV.

  • PDF

주파수 영역에서의 2단 접는 날개 공탄성 해석 (Aeroelastic Analysis in Frequency Domain for Wings with Double-Folding Mechanism)

  • 강명구;김기언
    • 한국군사과학기술학회지
    • /
    • 제9권4호
    • /
    • pp.104-113
    • /
    • 2006
  • To identify aeroelastic characteristics of wings with double-folding mechanism, aeroelastic analyses are performed. There are four wing models which consist of one linear model and three nonlinear models. The nonlinear models have one or two freeplay nonlinearties. The describing function method is used to approximately examine nonlinear effects. The aeroelastic module in MSC/NASTRAN is used to study the aeroelastic characteristics of the considered wing models. The effects of the folding mechanism and amplitude ratio are examined. As the amplitude ratio increases, the flutter speeds approach to those of the wing model with only one nonlinearity. The numerical results show that the flutter speeds of the wings with double-folding mechanism can be lower or higher than those of the wing model with only one folding mechanism depending upon the direction of the second folding mechanism.

DTMD를 이용한 플랜트 수직 펌프의 진동저감 (Vibration Reduction of Vertical Pumps in Industrial Plants Using Double TMDs)

  • 문영종;최현훈;김현수
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.51-58
    • /
    • 2017
  • The characteristics and effectiveness of double tuned mass dampers (DTMD) have been studied by many researchers. DTMD usually consists of one larger mass block and one smaller mass block. In this study, DTMD was proposed to reduce the vibration of vertical pumps in industrial plants. In order to assess the efficiency of the proposed method, numerical analysis for the simplified vertical pump model with single and double TMDs was carried out. It was also investigated that the effects of optimal TMD parameters such as frequency ratio and damping ratio on dynamic responses of the main structure. According to analysis results, DTMD are more effective to control the vibration of the vertical pump and show good robustness to the change in the stiffness of TMD.

Mode Identification in the Design of Wideband Cylindrical Monopole Antenna

  • Chun, Joong-Chang;Kim, Sang-Youl;Jeung, Deuk-Soo
    • Journal of information and communication convergence engineering
    • /
    • 제7권3호
    • /
    • pp.263-267
    • /
    • 2009
  • Cylindrical monopole antenna is one of most promising candidates for multi-band applications such as PCS, WLAN, DMB, and UWB wireless services. In this research, we demonstrate that there exist two types of current distributions according to the exciting frequency in a double band cylindrical monopole antenna, in which double resonance is achieved by adjusting the coupling structure of the antenna base. The operating modes of current distributions are identified from CST software simulations, the standing wave mode in a lower band and the traveling wave mode in a higher band. Also it is noticed that the mode behavior is quite similar to a helical antenna, a standing-wave (resonance) mode and a traveling-wave (non-resonance) mode according to the electrical dimensions of antenna. The effective ranges for operating modes and design formulas of the double band antenna are derived from simulation and measured results.

이중입구 맥동관냉동기의 수치적 해석 (Numerical Analysis of a Double Inlet Pulse Tube Refrigerator)

  • 채왕병;정은수;최헌오
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.501-511
    • /
    • 1995
  • A numerical model for predicting the performance of gas distrubutor type double inlet pulse tube refrigerators has been developed. The model was based on adiabatic analysis and the losses of heat exchangers and regenerator were considered. Thermodynamic behavior of working fluid within a double inlet pulse tube refrigerator was investigated and the effects of design parameters, such as valve and orifice openings, cold heat exchanger temperature, frequency and pulse tube length, on the cooling capacity and COP were shown.

  • PDF